Pixsys WP615 User manual

WEB Panel
WEBpanels capacitivi e resistivi
Capacitive and resistive WEBPanels
User manual / Manuale d’uso
WP615
WP800-WP815-WP820-WP830


Table of contents
1 Introduction .................................................................................................................................................................. 5
2 Safety guidelines.......................................................................................................................................................... 5
2.1 Policies and procedures.............................................................................................................................. 5
2.2 Installation guidelines................................................................................................................................. 5
2.3 Viruses and dangerous programs............................................................................................................ 5
2.4 Organization of safety notices.................................................................................................................. 6
3 Spacing for air circulation and ventilation............................................................................................................ 6
4 Environmental specifications and Approval ......................................................................................................... 6
5 Device installation....................................................................................................................................................... 7
6 Power supply and grounding.................................................................................................................................... 8
7 Wiring connections ..................................................................................................................................................... 9
8 Technical data............................................................................................................................................................... 9
8.1 Main features ................................................................................................................................................ 9
8.2 Hardware features ....................................................................................................................................... 9
8.3 Touch Screen Display .................................................................................................................................. 9
9 Communication interfaces...................................................................................................................................... 10
9.1 USB interface ............................................................................................................................................... 10
10 Ethernet interface ...................................................................................................................................................... 10
10.1 Technical data............................................................................................................................................. 10
10.2 Configuration modes ................................................................................................................................ 11
11 B at t e r y .......................................................................................................................................................................... 11
11.1 Internal battery replacement.................................................................................................................. 11
11.2 Battery detail............................................................................................................................................... 11
12 PixsysPortal ................................................................................................................................................................. 12
Indice degli argomenti
1 Introduzione................................................................................................................................................................ 14
2 Norme di sicurezza .................................................................................................................................................... 14
2.1 Regolamenti e procedure......................................................................................................................... 14
2.2 Linee guida per l’installazione ................................................................................................................ 14
2.3 Virus e programmi pericolosi .................................................................................................................. 14
2.4 Organizzazione delle note di sicurezza ................................................................................................ 15
3 Spazi per la circolazione dell’aria e la ventilazione ........................................................................................... 15
4 Specifiche ambientali e di funzionamento.......................................................................................................... 15
5 Installazione del dispositivo.................................................................................................................................... 16
6 Alimentazione e messa a terra dello strumento................................................................................................. 17
7 Collegamenti elettrici................................................................................................................................................ 17
8 Dati tecnici................................................................................................................................................................... 18
8.1 Caratteristiche generali ............................................................................................................................ 18
8.2 Caratteristiche hardware ......................................................................................................................... 18
8.3 Display touch screen ................................................................................................................................. 18
9 Interfaccia di comunicazione.................................................................................................................................. 19
9.1 Interfaccia USB............................................................................................................................................ 19
10 Interfaccia Ethernet................................................................................................................................................... 19
10.1 Dati tecnici ................................................................................................................................................... 19
10.2 Modalità configurabili ..............................................................................................................................20
11 B at t e ri a .........................................................................................................................................................................20
11.1 Sostituzione batteria tampone interna ................................................................................................20
11.2 Dettagli della batteria...............................................................................................................................20
12 PixsysPortal ................................................................................................................................................................. 21


User manual - WP Series - 5
1 Introduction
This document contains the complete description of the Pixsys Webpanel functionality.
The product is characterised by its functionality as a viewer of web pages published by a web server.
The Linux Yocto operating system installed in the device has been customised to the resources of the
device itself and allows easy updating via automatic procedures provided by Pixsys.
2 Safety guidelines
Programmable logic controllers (PLCs), operating/monitoring devices (industrial PCs, HMI) have
been designed, developed and manufactured for conventional use in industrial environments. They
were not designed, developed and manufactured for any use involving serious risks or hazards that
could lead to death, injury, serious physical damage or loss of any kind without the implementation
of exceptionally stringent safety precautions. In particular, such risks and hazards include the use of
these devices to monitor nuclear reactions in nuclear power plants, their use in flight control or flight
safety systems as well as in the control of mass transportation systems, medical life support systems
or weapons systems.
2.1 Policies and procedures
Electronic devices are never completely failsafe. If the programmable control system, operating/
monitoring device or power supply fails, the user is responsible for ensuring that other connected
devices, e.g. motors, are brought to a secure state.
When using programmable logic controllers or operating/monitoring devices as control systems
together with a soft PLC, safety precautions relevant to industrial control systems must be observed
in accordance with applicable national and international regulations. The same applies for all other
devices connected to the system, such as drives.
All tasks such as the installation, commissioning and servicing of devices are only permitted to be
carried out by qualified personnel. Qualified personnel are those familiar with the transport, mounting,
installation, commissioning and operation of devices who also have the appropriate qualifications
(e.g. IEC 60364). National accident prevention regulations must be observed.
The safety notices, information on connection conditions (type plate and documentation) and limit
values specified in the technical data are to be read carefully before installation and commissioning
and must always be observed.
2.2 Installation guidelines
• These devices are not ready for use upon delivery and must be installed and wired according to the
specifications in this documentation in order for the EMC limit values to apply.
• Installation must be performed according to this documentation using suitable equipment and
tools.
• Devices are only permitted to be installed by qualified personnel without voltage applied. Before
installation, voltage to the control cabinet must be switched off and prevented from being switched
on again.
• General safety guidelines and national accident prevention regulations must be observed.
• Electrical installation must be carried out in accordance with applicable guidelines (e.g. line cross
sections, fuses, protective ground connections).
2.3 Viruses and dangerous programs
This system is subject to potential risks each time data is exchanged or software is installed from a data
medium (e.g. CD-ROM or USB flash-disk), a network connection or the Internet. The user is responsible
for assessing these dangers, adopting anti-virus protection systems, firewalls, etc. not supplied (unless
otherwise stated) and ensuring that software packages are exclusively from Pixsys.
Table of contents

6 - WP Series - User manual
2.4 Organization of safety notices
Safety notices in this manual are organized as follows:
Safety notice Description
Danger! Disregarding these safety guidelines and notices can be life-threatening.
Warning! Disregarding these safety guidelines and notices can result in severe injury or
substantial damage to property.
Caution! Disregarding these safety guidelines and notices can result in injury or damage to
property.
Information! This information is important for preventing errors.
3 Spacing for air circulation and ventilation
In order to guarantee sufficient air circulation, allow 5cm of empty space above, below, to the side
and behind the device. No other ventilation system is required. The HMI device is self-ventilated and
approved for inclined mounting at angles up to ±35°in stationary cabinets.
Information! If additional space is needed to operate or maintain the device, this must be taken into
consideration during installation.
Caution! The spacing specifications for air circulation are based on the worst-case scenario for
operation at the maximum specified ambient temperature. The maximum specified ambient
temperature must not be exceeded!
Caution! An inclined installation reduces the convection by the HMI device and therefore the
maximum permissible ambient temperature for operation.
4 Environmental specifications and Approval
Operating temperature 0° C / 50° C
Storage temperature -20° C / 65° C
Relative humidity 10 / 90% non condensing
CE YES on rear panel
UL certification NO
RoHS compliant YES

User manual - WP Series - 7
5 Device installation
The device panel is installed in the cutout using provided plastic hooks. The number of provided
plastic hooks depends on the panel. The thickness of the wall or cabinet plate must be between 1 mm
and 8 mm. An ISO 7045 (ex UNI 7687 DIN 7985A) Phillips screwdriver is needed to tighten and loosen
the screws on the retaining clips. The maximum tightening torque for the retaining clips is 0,5 Nm.
Devices must be installed on a flat, clean and burr-free surface; uneven areas can cause damage to
the display when the screws are tightened or the intrusion of dust and water (as per figures 1 and 2).
Cut-out Fig. 1 Fig. 2
Lc +2 mm
Hc +2 mm
WP6XX Dimensions
Suggested
thickness/
Spessore
suggerito
0÷8 mm
+24V
1
20V
ETH2 ETH1
USB 1
M1
LW
Wc
Hc
H
Lc
D
Models D L H W * Wc * Lc Hc
WP615 10,1” 268 190 39,7 31,7 252,5 174,4

8 - WP Series - User manual
WP8XX Dimensions
Suggested
thickness/
Spessore
suggerito
0÷8 mm
+24V
1
20V
ETH2 ETH1
USB 1
M1
LW
Wc
Hc
H
Lc
D
Models D L H W * Wc * Lc Hc
WP800 8” 210 166 38 31,5 196 152
WP815 10,1” 268 190 40,2 31,7 252,5 174,5
WP820 12,1” 316,2 220 40,2 31,7 300,7 204,5
WP830 15,6” 408 257 45,2 36,7 391 240
* Dimensions refer only to the product without the size of terminals and cables.
6 Power supply and grounding
Danger! This device is only permitted to by supplied by a SELV /
PELV (class 2) power supply or with safety extra-low voltage (SELV)
in accordance with EN 60950.
Connect a 24VDC 1,0A (min.) power supply, as showed into the
figure. Connect the device grounding with a conductor of 18AWG
(2,5mmq) minimum section. For the whole series it is suggested to
use a 24 VDC 1,0A 24VA power supply (Pixsys code 2700.10.008).
Use Copper, Copper-Clad Aluminium or Aluminium conductors wire
for all electric connection.
Caution! 24VDC power supply line must be protected by a 1,0A
fuse.
Caution! Functional ground must be kept as short as possible and
connected to the largest possible wire cross section at the central
grounding point (e.g. the control cabinet or system).

User manual - WP Series - 9
7 Wiring connections
This device has been designed and manufactured in conformity to Low Voltage Directive 2006/95/EC,
2014/35/EU (LVD) and EMC Directive 2004/108/EC, 2014/30/EU (EMC). For installation into industrial
environments please observe following safety guidelines:
• Separate control lines form power wires;
• Avoid proximity of remote control switches, electromagnetic contactors, powerful engines and use
specific filters;
• Avoid proximity of power groups, especially those with phase control;
•
It is strongly recommended to install adequate mains filter on power supply of the machine where
the controller is installed, particularly if supplied 230 VAC. The controller is designed and conceived
to be incorporated into other machines, therefore CE marking on the controller does not exempt the
manufacturer of machines from safety and conformity requirements applying to the machine itself.
8 Technical data
8.1 Main features
WP615
Power supply voltage 12 ÷ 24 VDC ± 10%
Consumption (typical
use with USB devices) 12,5VA
WP800 WP815 WP820 WP830
Power supply voltage 12 ÷ 24 VDC ± 10%
Consumption (typical
use with USB devices) 11, 5VA 12,5VA 16VA 15VA
8.2 Hardware features
CPU Rockchip PX30 Quad-Core ARM - 4x Cortex-A35 (32 KB + 32 KB L1
cache and 256 KB L2 cache)
RAM 2GB LPDDR4-3200SDRAM
eMMC 16GB
GPU ARM Mali-G31 2EE
Operating system Linux Yocto Custom Image
8.3 Touch Screen Display
WP615
Touch technology Capacitive single touch
Resolution 10,1” TFT
1280 x 800
Colors 65K (16 bit)
Back-lighting LED 320 cd/m2
Back-lighting duration* 30000 h Typ
@ 25°C**
Lifetime** 10
WP800 WP615-WP815 WP820 WP830
Touch technology Resistive single touch
Resolution 8” TFT
1024 x 768
10,1” TFT
1280 x 800
12,1” TFT
1280 x 800
15,6” TFT
1366 x 768
Colors 65K (16 bit) 65K (16 bit) 65K (16 bit) 65K (16 bit)
Back-lighting LED 280 cd/m2 LED 320 cd/m2 LED 220 cd/m2 LED 300 cd/m2
Back-lighting duration* 50000 h Typ
@ 25°C**
30000 h Typ
@ 25°C**
50000 h Typ
@ 25°C**
Lifetime** 17 10 17
* Brightness reduction to 80% of default setting / ** Functioning years per 8 hours / day

10 - WP Series - User manual
9 Communication interfaces
All WP serie devices are equipped with two
Ethernet ports and one USB 2.0 port
9.1 USB interface
The WEBPanels are equipped with a rear USB 2.0 (Universal Serial Bus) port. This port allows the device
to be updated and settings to be backed up and restored via the control panel.
Warning! Peripheral USB devices can be connected to the USB interfaces on this device. Due to the
large number of USB devices available on the market, Pixsys cannot guarantee their performance.
Caution! Because this interface is designed according to general PC specifications, extreme care
should be exercised with regard to EMC, cable routing, etc.
Type USB 2.0
Design Type A
Transfer rate Low speed (1.5 Mbit/s), Full speed (12 Mbit/s), High speed (480 Mbit/s)
Current-carrying capacity Max. 0,6 A
Cable length Max. 3 m (without hub)
10 Ethernet interface
10.1 Technical data
This Ethernet controller is connected to external devices via the system unit.
Ethernet interface (ETH) ETH1 ETH2
Controller PX30 ETH PHY AX 88179
Cabling S/STP (Cat 5e)
Transfer rate 10/100 Mbit/s ETH1-ETH2 to CPU Link
10/100/Mbit/s ETH1-ETH2 link 1Gbit/s
LED
Green (link) On = 10/100 Mbit connection
Yellow (activity) On = Activity (data transfer)

User manual - WP Series - 11
10.2 Configuration modes
Two Ethernet ports are available on the rear of the operator
panel that can be configured to work in ‘bridge’ mode or with
‘independent’ configurations.
In
“bridge”
mode, it is possible to daisy-chain (or cascade)
several devices without using external Ethernet switches.
In
“independent”
mode, it is possible to configure each
Ethernet port with its own IP address, so as to obtain two
completely isolated networks, which is useful for separating
the machine network from the company/internet network.
In the case of panels with only one Ethernet port, it is possible
to add another by connecting the USB-Ethernet converter
with our code 2400.70.005 to the USB port, obtaining the
same functionality as described above.
Ethernet port configuration is done from the WPConfig utility,
refer to Software’s Manual.
LAPTOP
11 Battery
11.1 Internal battery replacement
BIOS and clock store data also in case of power failure thanks to
a CR2032 battery placed on rear.
To replace the battery it is necessary to remove the rear panel.
11. 2 Battery detail
Classification Lithium Coin
Chemical System Lithium / Manganese Dioxide (Li/MnO2)
Nominal Voltage 3.0 Volts
Typical Capacity 235 mAh (to 2.0 volts)
Typical (Li) Content 0.109 grams (0.0038 oz.)
Energy Density 198 milliwatt hr/g, 653 milliwatt hr/cc
Operating Temp -30C to 60C
Warning! CR2032 is a
“Lithium Coin”
battery
Danger! KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to serious injury or death in as little
as 2 hours due to chemical burns and potential perforation of the esophagus. To prevent children
from removing batteries, battery compartments is designed to be opened with a screwdriver and
is protected by a security label.
Warning! It is suggested to replace the battery every 3 years. When the battery is removed, an
internal dedicated device allows replacement without data loss if operation is completed within 1
hour since battery removal.

12 - WP Series - User manual
12 PixsysPortal
Pixsys operator panels integrate the PixsysPortal software service, which allows the creation of a VPN
connection optimised for industrial communications, enabling remote control (Remote Desktop, Web
Server, FTP data exchange) and remote assistance (connection to development environments) of the
panels themselves.
The service requires no firewall or static IP settings, only a standard Internet connection via cable or
via external devices such as 4G routers equipped with a data SIM card.
The PixsysPortal Windows PC application allows you to monitor all associated plants from a single
point, facilitating the operations of users who need to remotely control the plant.
The service is configured from the WPConfig utility, refer to Software’s Manual.
The PixsysPortal service requires an activation licence (our code 2400.38.002) to be associated to each
panel, alternatively the service will operate in demo mode, allowing a connection, lasting a maximum
of 15 minutes, every two hours.
For more information on the configuration and requirements of the service, please refer to the
documentation available on the dedicated page of our website www.pixsys.net or contact your sales
representative.

User manual - WP Series - 13
Warranty terms
Pixsys srl warrants its electronic devices for 12 months from Invoice date. Pixsys liability shall be limited
to repairing (or replacing at its option) any defective product which is returned with RMA (Return
Material Authorization) priorly obtained on Pixsys website and to be clearly marked on documents.
Pixsys shall not be responsible for accident, neglect, misuse, damage to objects or people caused
using the devices outside their specifications or outside any published performance data, including
unauthorized and unqualified repairing or failure to provide proper environmental conditions. In
no event shall Pixsys liability exceed the purchase price of the product(s). Warranty does not cover
any damage arising from post-sale installation of software applications and specifically any damage
caused by malware. Technical assistance by Pixsys which should be required to restore OS will be
subject to assistance fee prevailing at time of request
Notes / Updates

14 - WP Series - Manuale d’uso
1 Introduzione
Questo documento contiene la descrizione completa delle funzionalita’ dei Webpanel Pixsys.
Il prodotto si caratterizza per la funzionalità di visualizzatore di pagine Web pubblicate da un web
server. Il sistema operativo Linux Yocto installato nel dispositivo è stato personalizzato in base alle
risorse del dispositivo stesso e permette un facile aggiornamento tramite procedure automatiche
fornite da Pixsys.
2 Norme di sicurezza
Le indicazioni di questo manuale sono riferite a prodotti Pixsys quali i dispositivi logici programmabili
(PLC) e i dispositivi di controllo e monitoraggio (PC industriali, HMI) da ora in poi identificati
semplicemente con il termine
“Il dispositivo”
o
“i dispositivi”
. I dispositivi realizzati e commercializzati
da Pixsys sono progettati, sviluppati e realizzati per un uso convenzionale in ambienti industriali. Non
sono stati progettati, sviluppati e realizzati per qualsiasi altro uso che possa comportare gravi rischi
o pericoli quali decesso, lesioni, gravi danni fisici senza che siano adottati rigorosi sistemi di sicurezza
indipendenti dal dispositivo. In particolare, tali rischi e pericoli includono l’uso di questi dispositivi per
monitorare le reazioni nucleari nelle centrali, il loro uso nei sistemi di controllo o sicurezza del volo,
nonché nel controllo di sistemi di trasporto di massa, supporto a sistemi salvavita medicali o sistemi
d’armamento.
2.1 Regolamenti e procedure
I dispositivi elettronici non sono mai completamente sicuri. Se il dispositivo viene meno al suo
funzionamento, l’utente è responsabile di garantire che altri dispositivi connessi, ad es. motori,
siano portati in una condizione di sicurezza. Le precauzioni di sicurezza inerenti i sistemi di controllo
industriale devono essere adottate in conformità alle normative nazionali e internazionali applicabili
quando si utilizzano i dispositivi come sistemi di controllo insieme a Soft-PLC. Lo stesso vale per tutti
gli altri dispositivi collegati al sistema. Tutte le operazioni come l’installazione, la messa in servizio e la
manutenzione dei dispositivi devono essere eseguite solo da personale qualificato.
Il personale qualificato deve avere familiarità con il trasporto, montaggio, installazione, messa in
servizio e funzionamento dei dispositivi ed avere le previste qualifiche ad operare (ad esempio IEC
60364). È necessario osservare le norme nazionali sulla prevenzione degli incidenti.
Le avvertenze di sicurezza, le informazioni sulle condizioni di collegamento (etichette e documenta-
zione) e i valori limite specificati nei dati tecnici devono essere letti attentamente prima dell’installa-
zione e della messa in servizio e devono essere sempre osservati.
2.2 Linee guida per l’installazione
• Questi dispositivi non sono pronti per l’uso al momento della consegna, devono essere installati
e cablati secondo le indicazioni specifiche di questa documentazione al fine di rispettarne i limiti
EMC e gli standard di sicurezza.
• L’installazione deve essere eseguita secondo questa documentazione utilizzando attrezzature e
strumenti adeguati.
• I dispositivi devono essere installati solo da personale qualificato senza tensione applicata. Prima
dell’installazione, la tensione all’armadio elettrico deve essere spenta e ne deve essere impedita
l’accensione per tutto il tempo dell’intervento.
• Devono essere osservate le linee guida generali sulla sicurezza e le norme nazionali sulla
prevenzione degli incidenti.
• L’installazione elettrica deve essere eseguita in conformità alle linee guida applicabili (ad esempio
sezioni trasversali della linea, fusibili, collegamenti di terra protettivi).
2.3 Virus e programmi pericolosi
Questo sistema è soggetto a potenziali rischi ogni volta che i dati vengono scambiati o il software
viene installato da un supporto dati (ad esempio CD-ROM o flash-disk USB), una connessione di rete o
Internet. L’utente è responsabile della valutazione di questi pericoli, adottando sistemi di protezione
antivirus, firewall, ecc. non forniti (ove non diversamente dichiarato) e assicurandosi che i pacchetti
Indice degli argomenti

Manuale d’uso - WP Series - 15
software siano provenienti esclusivamente da Pixsys.
2.4 Organizzazione delle note di sicurezza
Le note sulla sicurezza in questo manuale sono organizzate come segue:
Note di sicurezza Descrizione
Danger! La mancata osservanza di queste linee guida e avvisi di sicurezza può essere
potenzialmente mortale.
Warning! La mancata osservanza di queste linee guida e avvisi di sicurezza può comportare
lesioni gravi o danni sostanziali alla proprietà.
Caution! La mancata osservanza di queste linee guida e avvisi di sicurezza può provocare
lesioni o danni alle cose.
Information! Tali informazioni sono importanti per prevenire errori.
3 Spazi per la circolazione dell’aria e la ventilazione
Per garantire una circolazione sufficiente dell’aria lasciare 5 cm di spazio vuoto sopra, sotto, di lato
e dietro il dispositivo. Nessuna altra ventilazione del sistema è richiesta. Il pannello operatore è
autoventilato e omologato per il montaggio inclinato con angoli fino a ± 35° in armadi fissi.
Information! Se è necessario spazio aggiuntivo per operare o mantenere il dispositivo, questo deve
essere preso in considerazione durante l’installazione.
Caution! Le specifiche di spazio per la circolazione dell’aria si basano sullo scenario peggiore di
funzionamento. La temperatura ambiente massima specificata non deve essere superata!
Caution! Un’installazione inclinata riduce la convezione del pannello operatore e quindi la
temperatura ambiente massima consentita per operazione che dovrà essere valutata assieme al
supporto tecnico Pixsys.
4 Specifiche ambientali e di funzionamento
Temperatura di esercizio 0° C / 50° C
Temperatura di stoccaggio -20° C / 65° C
Umidità relativa 10 / 90% senza condensa
Marchiatura CE SI sul pannello posteriore
Certificazione UL NO
Conformità RoHS SI

16 - WP Series - Manuale d’uso
5 Installazione del dispositivo
Il pannello del dispositivo è installato nel foro sul pannello macchina utilizzando i ganci in plastica
forniti seguendo le indicazioni di figure 1 e 2.
Il numero di ganci in plastica forniti dipende dal pannello da installare.
Lo spessore della parete o della piastra da forare per installare il dispositivo deve essere compresa tra
1 mm e 5 mm.
È necessario un cacciavite Phillips ISO 7045 (ex UNI 7687 DIN 7985A) per serrare o allentare le viti dei
ganci di fissaggio.
La coppia di serraggio massima per i ganci di fissaggio è di 0,5 Nm.
I dispositivi devono essere installati su una superficie piana, pulita e senza sbavature; aree irregolari
possono danneggiare il display quando le viti sono serrate o permettere l’intrusione di polvere e
acqua.
Dima foratura (cut-out) Fig. 1 Fig. 2
Lc +2 mm
Hc +2 mm
WP6XX Dimensioni
Suggested
thickness/
Spessore
suggerito
0÷8 mm
+24V
1
20V
ETH2 ETH1
USB 1
M1
LW
Wc
Hc
H
Lc
D
Modello D L H W * Wc * Lc Hc
WP615 10,1” 268 190 39,7 31,7 252,5 174,4

Manuale d’uso - WP Series - 17
WP8XX Dimensioni
Suggested
thickness/
Spessore
suggerito
0÷8 mm
+24V
1
20V
ETH2 ETH1
USB 1
M1
LW
Wc
Hc
H
Lc
D
Modello D L H W * Wc * Lc Hc
WP800 8” 210 166 38 31,5 196 152
WP815 10,1” 268 190 40,2 31,7 252,5 174,5
WP820 12,1” 316,2 220 40,2 31,7 300,7 204,5
WP830 15,6” 408 257 45,2 36,7 391 240
* Le dimensioni sono riferite al prodotto senza gli ingombri di terminali e cavi.
6 Alimentazione e messa a terra dello strumento
Danger! Questo dispositivo può essere alimentato solo da una
sorgente di alimentazione SELV / PELV (classe 2) o in classe di
sicurezza per bassissima tensione (SELV) secondo EN 60950.
Collegare una sorgente di alimentazione a 24VDC 1,0A (min.) come
nella figura accanto. Collegare la presa di TERRA dello strumento
con un conduttore di sezione minima 18AWG (2,5mmq). Per tutta
la gamma di strumenti si consiglia l’utilizzo di un alimentatore
dedicato da almeno 24 VDC 1,0A 24VA, vedere codice 2700.10.008.
Utilizzare fili in rame, alluminio rivestito in rame o alluminio per tutti
i collegamenti elettrici.
Caution! La linea di alimentazione 24 VDC deve essere protetta da
un fusibile da 2,5 A.
Caution! I collegamenti di massa devono essere il più corti possibili
ed eseguiti con filo con la sezione massima possibile verso il punto
centrale di messa a terra (ad esempio l’armadio o il sistema di
controllo).
7 Collegamenti elettrici
Il device è stato progettato e costruito in conformità alle Direttive Bassa Tensione 2006/95/CE, 2014/35/
UE (LVD) e Compatibilità elettromagnetica 2004/108/CE e 2014/30/UE (EMC). Per l’installazione in
ambienti industriali è buona norma seguire la seguenti precauzioni:

18 - WP Series - Manuale d’uso
• Distinguere la linea di alimentazioni da quelle di potenza.
• Evitare la vicinanza di gruppi di teleruttori, contattori elettromagnetici, motori di grossa potenza e
comunque usare appositi filtri.
• Evitare la vicinanza di gruppi di potenza, in particolare se a controllo di fase.
• Si raccomanda l’impiego di filtri di rete sull’alimentazione della macchina in cui lo strumento
verrà installato, in particolare nel caso di alimentazione 230 VAC. Si evidenzia che il regolatore è
concepito per essere assemblato ad altre macchine e dunque la marcatura CE del regolatore non
esime il costruttore dell’impianto dagli obblighi di sicurezza e conformità previsti per la macchina
nel suo complesso.
8 Dati tecnici
8.1 Caratteristiche generali
WP615
Tensione alimentazione 12 ÷ 24 VDC ± 10%
Consumo (utilizzo tipico con
device USB) 12,5VA
WP800 WP815 WP820 WP830
Tensione alimentazione 12 ÷ 24 VDC ± 10%
Consumo (utilizzo tipico con
device USB) 11, 5VA 12,5VA 15VA 20VA
8.2 Caratteristiche hardware
CPU Rockchip PX30 Quad-Core ARM - 4x Cortex-A35 (32 KB + 32 KB L1
cache and 256 KB L2 cache)
RAM 2GB LPDDR4-3200SDRAM
eMMC 16GB
GPU ARM Mali-G31 2EE
Sistema operativo Linux Yocto Custom Image
8.3 Display touch screen
WP615
Tecnologia touch Capacitiva singolo tocco
Risoluzione 10,1” TFT
1280 x 800
Colori 65K (16 bit)
Retroilluminazione LED 320 cd/m2
Durata
retroilluminazione*
30000 h Typ
@ 25°C**
Lifetime** 10
WP800 WP815 WP820 WP830
Tecnologia touch Resistiva singolo tocco
Risoluzione 8” TFT
1024 x 768
10,1” TFT
1280 x 800
12,1” TFT
1280 x 800
15,6” TFT
1366 x 768
Colori 65K (16 bit) 65K (16 bit) 65K (16 bit) 65K (16 bit)
Retroilluminazione LED 400 cd/m2 LED 320 cd/m2 LED 220 cd/m2 LED 300 cd/m2
Durata
retroilluminazione*
50000 h Typ
@ 25°C**
30000 h Typ
@ 25°C**
50000 h Typ
@ 25°C**
Lifetime** 17 10 17
* Riduzione luminosità all’80% del dato di fabbrica / ** Anni di funzionamento per 8 ore / giorno

Manuale d’uso - WP Series - 19
9 Interfaccia di comunicazione
Tutti i dispositivi della serie WEBPanel dispongono
di due porte Ethernet ed una porta USB 2.0
9.1 Interfaccia USB
I WEBPanel sono dotati di una porta USB 2.0 (Universal Serial Bus) posteriore. Tale porta, tramite
l’apposito pannello di controllo, permette l’aggiornamento del dispositivo e le operazioni di Backup e
Restore delle impostazioni.
Warning! Differenti dispositivi USB possono essere collegati alle interfacce USB su questo dispositivo.
A causa dell’elevato numero di dispositivi USB disponibili sul mercato, Pixsys non può garantire le
loro performance.
Caution! Poiché questa interfaccia è progettata in base a specifiche generali del settore PC, è
necessario prestare la massima attenzione per quanto riguarda EMC, cablaggi, ecc.
Tipo USB 2.0
Tipologia del connettore Type A
Transfer rate Low speed (1.5 Mbit/s), Full speed (12 Mbit/s), High speed (480 Mbit/s)
Massima corrente erogabile Max. 0,6 A
Lunghezza cavo Max. 3 m (senza hub)
10 Interfaccia Ethernet
10.1 Dati tecnici
Questo controller Ethernet è collegato a dispositivi esterni tramite l’unità di sistema.
Interfaccia Ethernet (ETH) ETH1 ETH2
Controller PX30 ETH PHY AX 88179
Cablaggio S/STP (Cat 5e)
Transfer rate 10/100 Mbit/s ETH1-ETH2 to CPU Link
10/100 Mbit/s ETH1-ETH2 link 1Gbit/s
LED
Verde (link) On = Connessione 10/100 Mbit
Giallo (activity) On = Activity (trasferim. dati)

20 - WP Series - Manuale d’uso
10.2 Modalità configurabili
Sul retro del pannello operatore sono disponibili due porte
Ethernet che possono essere configurate per lavorare in modalita
“bridge”
oppure con configurazioni
“indipendenti”
.
In modalità
“bridge”
è possibile realizzare una connessione di tipo
daisy-chain (o a cascata) di più dispositivi senza utilizzare switch
Ethernet esterni.
In modalità
“indipendente”
è possibile configurare ciascuna porta
Ethernet con il proprio indirizzo IP, in modo da ottenere due
reti completamente isolate tra loro, utile per separare la rete
macchina da quella aziendale/internet.
La configurazione delle porte Ethernet si effettua dall’utility
WPControl, fare riferimento al Manuale del Software.
LAPTOP
11 Batteria
11.1 Sostituzione batteria tampone interna
Il BIOS e l’orologio di sistema mantengono le loro funzionalità
in assenza di rete grazie ad una batteria CR2032 accessibile dal
pannello sul retro del terminale.
11. 2 Dettagli della batteria
Tipologia Batteria Litio CR2032
Composizione chimica Lithium / Manganese Dioxide (Li/MnO2)
Tensione Nominale 3.0 Volts
Capacità 235 mAh (fino a 2.0 volts)
Contenuto tipico di Litio (Li) 0.109 gr. (0.0038 oz.)
Densità di energia 198 milliwatt hr/g, 653 milliwatt hr/cc
Temperatura di utilizzo -30C a 60C
Warning! CR2032 è una batteria al litio (Li)
“a bottone”
.
Danger! TENERE FUORI DALLA PORTATA DEI BAMBINI. La deglutizione può portare a lesioni gravi
o morte in meno di 2 ore a causa di ustioni chimiche e potenziale perforazione dell’esofago. Per
evitare che i bambini rimuovano le batterie, il vano batteria è progettato per essere aperto con un
cacciavite ed è protetto da un’etichetta di sicurezza.
Warning! Si consiglia di sostituire la batteria ogni 3 anni. Quando la batteria viene rimossa, un
dispositivo interno dedicato consente la sostituzione senza perdita di dati se l’operazione è
completata entro 1 ora dalla rimozione della batteria.
This manual suits for next models
4
Table of contents
Languages:
Other Pixsys Touch Panel manuals
Popular Touch Panel manuals by other brands

Siemens
Siemens PC 677B operating instructions

Siemens
Siemens SIMATIC HMI operating instructions

Citadel
Citadel TS9000 user manual

AMX
AMX Modero ViewPoint MVP-8400 quick start guide

Avalue Technology
Avalue Technology AID-173S Quick reference guide

Ingersoll-Rand
Ingersoll-Rand VON DUPRIN installation instructions