manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Plasma Ions
  6. •
  7. Air Cleaner
  8. •
  9. Plasma Ions PS-502T User manual

Plasma Ions PS-502T User manual

Plasma Air disinfection system
(Please read the instructions before use)
Plasma Ions
PS-502T
Precautions
This machine is designed for only indoor general using. Do not place it open-air or high
temperature place.
Before operating the machine, make sure the power cord is firmly plugged into the power
outlet, and place the power cord in a safe position. Do not touch, install or unplug the
power cord with wet hands to avoid electric shock accidents.
Before unplugging the power cord, please turn off the machine power in the correct
procedure, otherwise it may cause damage to the machine.
If don't use the machine for a long time, please unplug the power supply.
Before operation, please check whether the air inlet and outlet positions of the duct
system are blocked.
The machine has precision components built inside. Don't open the case by yourself to
avoid damage to the machine parts and may happen dangerous.
Pay attention to ventilation when using it together with fuel appliances. Please do not use
machine in the kitchen.
Before cleaning the chassis of the machine, make sure turn off the power and unplug it of
the machine.Only use cloth with a little clean water and clean it softly,don't use volatile
cleaners.
Forbidding to place and using in the bathroom, otherwise it may cause electric shock.
Play a long-lasting and active positive and negative ion purification effect
Unique and novel appearance Sturdy metal design Plams ions
The product can be used for a long time,(It is recommended to clean the ionization
tube for about 12 months, and to clean or replace the filter, at the user's discretion.)
Use and characteristics
There are electronic devices installed inside, do not open the case to avoid the risk of electric shock.
Please read this [user manual] carefully before using the machine and follow the below points of
operation base on the manual.Otherwise It may cause damage to product, or even cause injury
to yourself or others at varying degrees.
Warranty Card
(Please keep it properly)
Product
Name
Purchase
Time
Product
Number
Contact
Number
Customer
information
Name/company
contact address
Sales company stamp:
Pipeline installation Product installation
a) Open a 130*130mm port on the pipe surface.
b) Use scissors or a metal plate cutter to cut the marked area
c) Align the flange washer and use self-acting screws to fix the device to the pipeline.
1. If it cannot be installed in the preferred location due to space constraints, please
refer to the alternate location shown in the figure below.
2. Select a location with good air flow in the air handling unit.
3. Connect the power supply, the indicator light is on, and the number of ions can be
adjusted in 1, 2, and 3 gears.
Installin fan coil
1. Check whether the product is intact before installation and run the test with power
on. If damaged during transportation, please contact customer service in time.
2. This product should not be installed in a place where the air temperature exceeds
60°, preferably in a location with smooth ventilation.
Pipe cut size
Horizontal hole pitch: 152mm
Vertical hole distance: 152mm
Pipe shear opening range: 130*130mm
1. Make sure that the product is hanging
on the wall before installation The distance
of the hole marks the position where the
hole needs to be punched.
2. Use a drill to drill holes at the marked
locations.
3. Put the product pipe first at the opening
of the pipe shearPlace it in balance.
4. Then align the holes with holes and
screw them in.
130mm
152mm
152mm
152mm 130mm
130MM
130MM
(a) (b) (c)
1.Please read this manual carefully before use.
2.Free services can be provided with warranty card and invoice,welcome to contact us
if you need technical support.
3.Customers can enjoy 1 year warranty service by us with product related invoice and
documents.
4.Please keep the warranty card properly so that the warranty can be obtained when
the product needs repair.
5.The company is not responsible for the following repair services beyond the product,
but we can still provide you with paid services.
Products due to improper use or storage.
Products without warranty card or other valid documents.
Products due to unstable power supply voltage or beyond the normal voltage
range or power supply and installation does not meet the electrical installation
requirements.
Promotional products.
Products damaged caused by irresistible natural disasters.
Products beyond maintenance period,damaged due to not follow the rules and
methods of application.
Maintenance notice
Plasma generator
Power and other
indicator signals
are not lit
Check if the power cords securely inserted into the unit and
it is loose. Check the power outlet for power supply and check
the 1.0 mA standard (certified) fuse
Under normal circumstances, there is a slight current sound
and black There is a faint blue light in the dark. If found.The
ion tube bursts and the ion tube needs to be replaced.0.5 mA
standard (with certified) fuse.
Please send the following to the company's designated
maintenance department for repairs.
1. The problem cannot be solved as described above.
2. Foreign matter or moisture enters, and abnormal conditions occur.
Fault condition Processing check
Fault check
Installation Instructions
Warning: In order to reduce the risk of fire, do not install the equipment in a wet place.This product
is be installed in the metal structure pipe, And the installation don’t destory the structural integrity
of the piping.This product should not be installed where the air temperature more than 60° c Pull
open the power supply metal clamp and screw the ion tube into the power supply, The best
installation location is in the pipe outlet, or air return and ventilation ducts
Size Ion tube size
260*175*60mm 80mm(3寸)
Ion tube life ≤2 years
Model
Voltage
Area
Power
Air volume
Weight
Noise
PS-502T
AC220V
200㎡
≤50db
20W
5000cfm/8500m³/h
3.1Kg
2(Standard)
Technology specification
192*192*430mm
Size Ion tube size 350mm(14inch)
Ion Tube
quantity

This manual suits for next models

2

Other Plasma Ions Air Cleaner manuals

Plasma Ions PS-502S User manual

Plasma Ions

Plasma Ions PS-502S User manual

Plasma Ions PS-501TV User manual

Plasma Ions

Plasma Ions PS-501TV User manual

Plasma Ions PS-501TV User manual

Plasma Ions

Plasma Ions PS-501TV User manual

Plasma Ions PS-501TY User manual

Plasma Ions

Plasma Ions PS-501TY User manual

Plasma Ions PS-500T2 User manual

Plasma Ions

Plasma Ions PS-500T2 User manual

Plasma Ions PS-501T1 User manual

Plasma Ions

Plasma Ions PS-501T1 User manual

Plasma Ions PS-501T6 User manual

Plasma Ions

Plasma Ions PS-501T6 User manual

Plasma Ions PS-500T2 User manual

Plasma Ions

Plasma Ions PS-500T2 User manual

Plasma Ions PS-501TR User manual

Plasma Ions

Plasma Ions PS-501TR User manual

Plasma Ions PS-501TW User manual

Plasma Ions

Plasma Ions PS-501TW User manual

Plasma Ions PS-501T1-UV User manual

Plasma Ions

Plasma Ions PS-501T1-UV User manual

Plasma Ions PS-300 User manual

Plasma Ions

Plasma Ions PS-300 User manual

Plasma Ions PS-500T1 User manual

Plasma Ions

Plasma Ions PS-500T1 User manual

Plasma Ions PS-501S User manual

Plasma Ions

Plasma Ions PS-501S User manual

Plasma Ions PS-501T2 User manual

Plasma Ions

Plasma Ions PS-501T2 User manual

Plasma Ions PS-500T1 User manual

Plasma Ions

Plasma Ions PS-500T1 User manual

Popular Air Cleaner manuals by other brands

Olimpia splendid FUTURA Instructions for use and maintenance

Olimpia splendid

Olimpia splendid FUTURA Instructions for use and maintenance

Honeywell HFD28X user manual

Honeywell

Honeywell HFD28X user manual

Amcor AM-15 owner's manual

Amcor

Amcor AM-15 owner's manual

Goodman GDMHEPA Specification sheet

Goodman

Goodman GDMHEPA Specification sheet

Aktobis WDH-AP1101 manual

Aktobis

Aktobis WDH-AP1101 manual

Carrier EACA Installation and operation manual

Carrier

Carrier EACA Installation and operation manual

Trion Air Boss T5200 Installation and operation

Trion

Trion Air Boss T5200 Installation and operation

enVerid AP-W-120V-14W-2 Installation, operation, maintenance guide

enVerid

enVerid AP-W-120V-14W-2 Installation, operation, maintenance guide

AIR LAB ACY2WH user manual

AIR LAB

AIR LAB ACY2WH user manual

NateoSante EOLIS Air Manager instruction manual

NateoSante

NateoSante EOLIS Air Manager instruction manual

Ivation IVAHAP300 user guide

Ivation

Ivation IVAHAP300 user guide

PuriSystems HEPA 600 UVIG user manual

PuriSystems

PuriSystems HEPA 600 UVIG user manual

Glen GL 6033 user guide

Glen

Glen GL 6033 user guide

proWIN AIR BOWL Directions for using

proWIN

proWIN AIR BOWL Directions for using

Giabo PAC2302 user manual

Giabo

Giabo PAC2302 user manual

Sharp FP-K50U Operation manual

Sharp

Sharp FP-K50U Operation manual

Bionaire BAP1550 instruction manual

Bionaire

Bionaire BAP1550 instruction manual

LG PS-S200 Series owner's manual

LG

LG PS-S200 Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.