PPA C36 User manual

C36 Smart Alarm
Self-monitored alarm board by Android and IOS app with sending
notification in real time, automation and integration with the PPA On line
through the internet via a Wi-Fi connection. Fast and simple registration,
intuitive operation.
Main features:
- Equipped with switched power supply;
- Siren output;
- 12V 7Ah battery charger;
- 1 configurable auxiliary output;
- 4 wired zones;
- Up to 32 wireless zones;
- Up to 32 remote controls;
- Internal, intelligent, timed and 24h zones;
- Internal arming by control key;
- Led (armed and disarmed status);
- Programmable siren time;
- Programmable exit time;
- Programmable entry time;
- Configurable arm/disarm beep;
- Shutdown function on sensors and zones (ignores after 4 shots);
- Monitors battery and power failure;
- Protection against battery short.
Technical features:
Power: 90-240Vac;
Battery: Lead acid 12V 7Ah;
Wi-Fi communication: 802.11 b/g/n 2.4GHz standard;
Wireless Sensors: Open Standard, Fixed Code Compatible with HT6P20;
Remote controls: PPA rolling code, anti-cloning;
Consumption: 300 mA (max);
Dimensions: 230x240x100mm (HxWxD);
Weight: 690g.
Leds:
POWER: Power indicator on source input
STATUS PROG: Reception indicator from a wireless remote control or
sensor
PROG WIFI: WiFi connection status indicator.
Off = Initializing / Offline
Fast flashing = Smart registration mode.
Slow flashing = AP registration mode.
Flashing 1 time = Searching for Wi-Fi signal.
Flashing 2 times = Searching cloud server.
On = Connected to Wi-Fi and cloud.
STATUS: Armed board indicator (On) Disarmed (Off) Shooting (Flashing)
Keys:
PROG: Learning remote controls / Wi-fi connection setup, follow the
app instructions.
APRENDER: Learn wireless sensors / Reset to factory default.
Connections:
CN2: Switched source input of the board.
12V / GND: Power output for sensors.
Z1: Zone 1 wired sensor input. Can be disabled by closing jumper Z1.
Z2: Zone 2 wired sensor input. Can be disabled by closing jumper Z2
Z3: Zone 3 wired sensor input. Can be disabled by closing jumper Z3
Z4: Zone 4 wired sensor input. Can be disabled by closing jumper Z4
SIRENE / GND : Connection to siren.
NA: Auxiliary relay normally open contact.
CO: Auxiliary relay common contact.
NF: normally closed contact of the auxiliary relay.
Operation:
Wireless sensors programming: With the board in Disarmed mode.
Press the 'Learn' key briefly, 'Status Prog' LED flashes quickly. Trigger the
wireless sensor.
Programming the remote controls: With the board in Disarmed mode.
Press 'Prog' key briefly, 'Status Prog' LED flashes quickly. Press a button
on the remote.
Product description:
Panic Trigger: Press any key on a remote control registered and hold for
3s or more.
Reset to Factory Default: Press the 'Learn' key and the keep it pressed
for 15s until the 'Status Prog' led turns on. All remote controls and
sensors will be erased and settings will return to factory defaults. (WiFi
connection setting is not affected).
Trigger: When there is a sensor violation or panic trigger, the board will
activate the siren for the programmed time (default 5 min), the STATUS
led flashes fast indicating the trigger until the board is disarmed or
rearmed.
Auxiliary Relay: The auxiliary relay provides a dry contact output for
trigger loads such as high-powered lamps, sirens, or provide status to
other equipment. Its default operation is to trigger along with the siren
output and can be customized in the app as to triggering time and mode.
The possible trigger modes are: Trigger with the control panel disarmed,
with the board armed, with the internal arming and with the trigger.
Sensor inputs: (Z1, Z2, Z3, Z4). One or more wired sensors can be
connected between terminals Z(1-4) and GND. It will be considered
violated if the connection is interrupted.
Jumpers Z(1-4): If closed, deactivate the zone corresponding Z(1-4).
Unused zones must be disabled.
Siren Output: The output is suitable for connecting one or more sirens
with total consumption of up to 1A. If this output goes into a short circuit
or presents a very high consumption due to a defect or an attempt at
sabotage, the “Siren Sensor” will be violated and the board will be
triggered. In this situation, it is ideal to have a second siren installed with
the PGM relay in the “Start with siren” mode.
Application:
Search the store for the 'PPA ON' app.
Create the account in the app.
Add a device.-> Alarm (Wi-Fi)
Keep the cell phone close to the module at the installation site. Check
that the signal level of the mobile Wi-Fi network is good.
Press the PROG button for 5s.
Follow the onscreen instructions.
WARNING:
Do not use the equipment
without referring to this
manual rst.
P30394 - 10/2022
Rev. 1
MANUAL
C36 SMART
ALARM
Historic:
Displays the history of the latest
alarm events, like arming,
disarming, shooting, etc..
Accessories:
Screen for registration and
consultation of accessories
(wired and wireless sensors and
remote controls).
PPA
Restart device first
If the Wifi Led (Blue) is flashing quickly,
skip the reset step.
1 On
2 Press the PROG button for 5 seconds
3 Make sure the Wifi Led (Blue) is flashing
quickly
Confirm that the Wifi Led (Blue)
is flashing quickly
Select a 2.4GHz Wi-Fi network
and enter the password.
If Wi-fi is 5GHz, set it to 2.4GHz before
proceeding. Common method of
router configuration.
Add device
Make sure the device is turned on
Accessories Accessories
Wireless Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 1?
Unknown 2?
Unknown 3?
Sensor Remote Control Sensor Remote Control
Wired Sensor Wired Sensor
Standard Control
Cancel
Cancel
Cancel
EZ mode
Restart devices
Next
Password
Next
Analyze
the devices
Register the
device on
the Cloud
Start
the device
Accessory Types:
Wireless Sensor: Sensors and remote controls with fixed code for panic
triggering. The board allows up to 32 devices of this type.
Remote Control: Remote Controls with Rolling Code Compatible with
PPA. (Ex.: ZAP4 and Slim models). Up to 32 registered remotes are
allowed.
Wired Sensor: Inputs for wired switchboard sensors (Z1,Z2,Z3 and Z4)
and siren sensor. When deleted, these devices return to the factory
default settings.
Zone Type:
Immediate: Default zone type, triggers the siren and sends notification
if the switch is armed.
Internal: Special zone for motion sensors and interior doors, which do
not trigger when the alarm is in 'Internal Arm' mode. Ideal for when the
alarm is armed with residents within the protected perimeter.
24 Hours: Zone that triggers the siren and notification at all times, even
with the alarm in 'Disarmed' mode, ideal for use with panic devices and
perimeter sensors such as electric fence alarm outputs.
Delayed: Zone that ignores triggers within the tolerance time for input
and/or output programmed into the system.
Follower: This zone type behaves like an Immediate zone normally,
however, it becomes a Delayed zone if a Delayed type zone is in time
count.
Zone Attribute:
None: Standard operation.
Smart: With this attribute type there must be 2 openings in the zone in
less than 1 minute or an opening lasting longer than 1 minute to be
considered a violation. It is generally used to prevent false triggering on
some types of wired sensors. Has no effect on wireless sensors.
Silent: When triggering it does not trigger the siren, but sends the
notification to the application normally.
Not Self Bypassing: The zone does not obey the autobypass rule after 4
shots.
Add
Tipo: Movimiento
Zona: Normal
Tipo: Movimiento
Zona: Normal
Status: Normal
Status: Normal
Desconocido 2?
Desconocido 3?
Delete/Edit name
Accessories
Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 2?
Unknown 3?
Sensor Remote Control
Wired Sensor
Slide left
Settings:
Arm/Disarm Sound: Activates the Arm or Disarm notification function
disarm the board by the siren output. It emits two beeps to indicate
board disarming and one beep to indicate disarming. The PGM output
does not trigger in this case even if it is in the “Sir with Siren” mode.
PGM Output Mode: Selects the relay triggering condition PGM.
Possible conditions: Trigger with siren, Trigger in Arming mode,
Triggering in Internal Arming mode or Triggering in Disarmed mode.
PGM output: (Enabled / Disabled) Indicates whether the siren must be
activated in case of a trip.
PGM time: Time in minutes for activating the PGM output. After the
configured time, the output is deactivated. A time equal to zero indicates
triggering with hold (infinite as long as the triggering condition remains).
Siren Trigger Time: Time in minutes for activating the siren. After the
configured time, the siren is deactivated.
Siren Output: (Enabled / Disabled) Indicates whether the Siren must be
activated in the event of a trip.
Entry Delay: Tolerance time for triggering 'Delayed' type zones after
their violation. It is commonly used to allow the user to enter within the
perimeter and have a short period of time to disarm the switch without
firing it.
Exit Time: Tolerance time for triggering zones of the type after the
switch is placed in 'Arm' or 'Internal Arm' mode. Violations in sensors in
these zones within the programmed time do not trigger the switch. It is
used to allow the user to arm the switch when leaving the secured
perimeter.
Made by:
Motoppar Indústria e Comércio de Automatizadores Ltda
Av. Dr. Labieno da Costa Machado, 3526 - Distrito Industrial
Garça - SP - CEP 17406-200 - Brasil
CNPJ: 52.605.821/0001-55
www.ppa.com.br | +55 14 3407 1000
GENERAL TERMS AND CONDITIONS OF WARRANTY
MOTOPPAR, Industry and Commerce of Automatic Gate Operators
Ltd., registered with the CNPJ (National Registry of Legal Entities)
under Number 52.605.821/0001-55, located at 3526 Dr. Labieno da
Costa Machado Avenue, Industrial District, Garça – SP – Brazil, Zip
Code 17400-000, manufacturer of PPA Products, hereby
guarantees this product against design, manufacturing or assembly
defects and/or supportively as a result of material quality flaws that
could make its intended use improper or inadequate, within a legal
period of ninety days from time of acquisition, provided that the
installation instructions described in the instruction manual are
observed.
Due to the credibility and trust placed on PPA products, we will add
275 more days to the period mentioned above, reaching a warranty
period of one year, likewise counted from the time of acquisition
proven by consumer through proof of purchase (Customer Receipt).
In case of defect, within the warranty period, PPA responsibilities are
restricted to the repair or substitution of the product manufactured by
the company, under the following conditions:
1. Repair and readjustment of equipment may only be carried
out by PPA Technical Assistance, which is qualified to open,
remove, and substitute parts or components, as well as repair
defects covered by this warranty; thus, failure on observing
this guideline and the verified use of any non-original parts will
cause the resignation of this warranty on the part of the user;
2. The warranty will not extend to accessories such as cables,
screw kit, fixing brackets, power supplies etc.;
3. Expenses for packaging, transportation and product
reinstallation will be sole responsibility of the consumer;
4. The equipment must be sent directly to the Company
responsible for the sale (manufacturer's representative),
through the address contained in the purchase invoice,
properly packed, thus avoiding loss of the warranty;
5. Within the additional period of 275 days, visits and
transportation in places where authorized technical
assistance is not available will be charged. The cost of
transportation of the product and/or technician will be sole
responsibility of the consumer and
6. The substitution or repair of the product does not prolong the
warranty time.
This warranty will be terminated if the product:
1. Is damaged by natural agents, such as atmospheric
discharges, floods, wildfires, landslides etc.;
2. Is installed in an improper electric power supply or if it is not
according to any of the installation instructions displayed on
the manual;
3. Shows defects caused by droppings, collisions or any other
physical accident;
4. Shows signs of product violation or attempted repair by
unauthorized personnel;
5. Is not used for its intended purpose;
6. Is not used under normal conditions;
7. Is damaged by accessories or equipment connected to it.
Recommendation:
We recommend that both the installation and the maintenance of the
operator to be performed by an authorized PPA technical service. If
the product fails or has an improper operation, seek an Authorized
Technical Service to fix it..

C36 Smart Alarm
Self-monitored alarm board by Android and IOS app with sending
notification in real time, automation and integration with the PPA On line
through the internet via a Wi-Fi connection. Fast and simple registration,
intuitive operation.
Main features:
- Equipped with switched power supply;
- Siren output;
- 12V 7Ah battery charger;
- 1 configurable auxiliary output;
- 4 wired zones;
- Up to 32 wireless zones;
- Up to 32 remote controls;
- Internal, intelligent, timed and 24h zones;
- Internal arming by control key;
- Led (armed and disarmed status);
- Programmable siren time;
- Programmable exit time;
- Programmable entry time;
- Configurable arm/disarm beep;
- Shutdown function on sensors and zones (ignores after 4 shots);
- Monitors battery and power failure;
- Protection against battery short.
Technical features:
Power: 90-240Vac;
Battery: Lead acid 12V 7Ah;
Wi-Fi communication: 802.11 b/g/n 2.4GHz standard;
Wireless Sensors: Open Standard, Fixed Code Compatible with HT6P20;
Remote controls: PPA rolling code, anti-cloning;
Consumption: 300 mA (max);
Dimensions: 230x240x100mm (HxWxD);
Weight: 690g.
Leds:
POWER: Power indicator on source input
STATUS PROG: Reception indicator from a wireless remote control or
sensor
PROG WIFI: WiFi connection status indicator.
Off = Initializing / Offline
Fast flashing = Smart registration mode.
Slow flashing = AP registration mode.
Flashing 1 time = Searching for Wi-Fi signal.
Flashing 2 times = Searching cloud server.
On = Connected to Wi-Fi and cloud.
STATUS: Armed board indicator (On) Disarmed (Off) Shooting (Flashing)
Keys:
PROG: Learning remote controls / Wi-fi connection setup, follow the
app instructions.
APRENDER: Learn wireless sensors / Reset to factory default.
Connections:
CN2: Switched source input of the board.
12V / GND: Power output for sensors.
Z1: Zone 1 wired sensor input. Can be disabled by closing jumper Z1.
Z2: Zone 2 wired sensor input. Can be disabled by closing jumper Z2
Z3: Zone 3 wired sensor input. Can be disabled by closing jumper Z3
Z4: Zone 4 wired sensor input. Can be disabled by closing jumper Z4
SIRENE / GND : Connection to siren.
NA: Auxiliary relay normally open contact.
CO: Auxiliary relay common contact.
NF: normally closed contact of the auxiliary relay.
Operation:
Wireless sensors programming: With the board in Disarmed mode.
Press the 'Learn' key briefly, 'Status Prog' LED flashes quickly. Trigger the
wireless sensor.
Programming the remote controls: With the board in Disarmed mode.
Press 'Prog' key briefly, 'Status Prog' LED flashes quickly. Press a button
on the remote.
Product description:
Panic Trigger: Press any key on a remote control registered and hold for
3s or more.
Reset to Factory Default: Press the 'Learn' key and the keep it pressed
for 15s until the 'Status Prog' led turns on. All remote controls and
sensors will be erased and settings will return to factory defaults. (WiFi
connection setting is not affected).
Trigger: When there is a sensor violation or panic trigger, the board will
activate the siren for the programmed time (default 5 min), the STATUS
led flashes fast indicating the trigger until the board is disarmed or
rearmed.
Auxiliary Relay: The auxiliary relay provides a dry contact output for
trigger loads such as high-powered lamps, sirens, or provide status to
other equipment. Its default operation is to trigger along with the siren
output and can be customized in the app as to triggering time and mode.
The possible trigger modes are: Trigger with the control panel disarmed,
with the board armed, with the internal arming and with the trigger.
Sensor inputs: (Z1, Z2, Z3, Z4). One or more wired sensors can be
connected between terminals Z(1-4) and GND. It will be considered
violated if the connection is interrupted.
Jumpers Z(1-4): If closed, deactivate the zone corresponding Z(1-4).
Unused zones must be disabled.
Siren Output: The output is suitable for connecting one or more sirens
with total consumption of up to 1A. If this output goes into a short circuit
or presents a very high consumption due to a defect or an attempt at
sabotage, the “Siren Sensor” will be violated and the board will be
triggered. In this situation, it is ideal to have a second siren installed with
the PGM relay in the “Start with siren” mode.
Application:
Search the store for the 'PPA ON' app.
Create the account in the app.
Add a device.-> Alarm (Wi-Fi)
Keep the cell phone close to the module at the installation site. Check
that the signal level of the mobile Wi-Fi network is good.
Press the PROG button for 5s.
Follow the onscreen instructions.
WARNING:
Do not use the equipment
without referring to this
manual rst.
P30394 - 10/2022
Rev. 1
MANUAL
C36 SMART
ALARM
Historic:
Displays the history of the latest
alarm events, like arming,
disarming, shooting, etc..
Accessories:
Screen for registration and
consultation of accessories
(wired and wireless sensors and
remote controls).
PPA
Restart device first
If the Wifi Led (Blue) is flashing quickly,
skip the reset step.
1 On
2 Press the PROG button for 5 seconds
3 Make sure the Wifi Led (Blue) is flashing
quickly
Confirm that the Wifi Led (Blue)
is flashing quickly
Select a 2.4GHz Wi-Fi network
and enter the password.
If Wi-fi is 5GHz, set it to 2.4GHz before
proceeding. Common method of
router configuration.
Add device
Make sure the device is turned on
Accessories Accessories
Wireless Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 1?
Unknown 2?
Unknown 3?
Sensor Remote Control Sensor Remote Control
Wired Sensor Wired Sensor
Standard Control
Cancel
Cancel
Cancel
EZ mode
Restart devices
Next
Password
Next
Analyze
the devices
Register the
device on
the Cloud
Start
the device
Accessory Types:
Wireless Sensor: Sensors and remote controls with fixed code for panic
triggering. The board allows up to 32 devices of this type.
Remote Control: Remote Controls with Rolling Code Compatible with
PPA. (Ex.: ZAP4 and Slim models). Up to 32 registered remotes are
allowed.
Wired Sensor: Inputs for wired switchboard sensors (Z1,Z2,Z3 and Z4)
and siren sensor. When deleted, these devices return to the factory
default settings.
Zone Type:
Immediate: Default zone type, triggers the siren and sends notification
if the switch is armed.
Internal: Special zone for motion sensors and interior doors, which do
not trigger when the alarm is in 'Internal Arm' mode. Ideal for when the
alarm is armed with residents within the protected perimeter.
24 Hours: Zone that triggers the siren and notification at all times, even
with the alarm in 'Disarmed' mode, ideal for use with panic devices and
perimeter sensors such as electric fence alarm outputs.
Delayed: Zone that ignores triggers within the tolerance time for input
and/or output programmed into the system.
Follower: This zone type behaves like an Immediate zone normally,
however, it becomes a Delayed zone if a Delayed type zone is in time
count.
Zone Attribute:
None: Standard operation.
Smart: With this attribute type there must be 2 openings in the zone in
less than 1 minute or an opening lasting longer than 1 minute to be
considered a violation. It is generally used to prevent false triggering on
some types of wired sensors. Has no effect on wireless sensors.
Silent: When triggering it does not trigger the siren, but sends the
notification to the application normally.
Not Self Bypassing: The zone does not obey the autobypass rule after 4
shots.
Add
Tipo: Movimiento
Zona: Normal
Tipo: Movimiento
Zona: Normal
Status: Normal
Status: Normal
Desconocido 2?
Desconocido 3?
Delete/Edit name
Accessories
Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 2?
Unknown 3?
Sensor Remote Control
Wired Sensor
Slide left
Settings:
Arm/Disarm Sound: Activates the Arm or Disarm notification function
disarm the board by the siren output. It emits two beeps to indicate
board disarming and one beep to indicate disarming. The PGM output
does not trigger in this case even if it is in the “Sir with Siren” mode.
PGM Output Mode: Selects the relay triggering condition PGM.
Possible conditions: Trigger with siren, Trigger in Arming mode,
Triggering in Internal Arming mode or Triggering in Disarmed mode.
PGM output: (Enabled / Disabled) Indicates whether the siren must be
activated in case of a trip.
PGM time: Time in minutes for activating the PGM output. After the
configured time, the output is deactivated. A time equal to zero indicates
triggering with hold (infinite as long as the triggering condition remains).
Siren Trigger Time: Time in minutes for activating the siren. After the
configured time, the siren is deactivated.
Siren Output: (Enabled / Disabled) Indicates whether the Siren must be
activated in the event of a trip.
Entry Delay: Tolerance time for triggering 'Delayed' type zones after
their violation. It is commonly used to allow the user to enter within the
perimeter and have a short period of time to disarm the switch without
firing it.
Exit Time: Tolerance time for triggering zones of the type after the
switch is placed in 'Arm' or 'Internal Arm' mode. Violations in sensors in
these zones within the programmed time do not trigger the switch. It is
used to allow the user to arm the switch when leaving the secured
perimeter.
Made by:
Motoppar Indústria e Comércio de Automatizadores Ltda
Av. Dr. Labieno da Costa Machado, 3526 - Distrito Industrial
Garça - SP - CEP 17406-200 - Brasil
CNPJ: 52.605.821/0001-55
www.ppa.com.br | +55 14 3407 1000
GENERAL TERMS AND CONDITIONS OF WARRANTY
MOTOPPAR, Industry and Commerce of Automatic Gate Operators
Ltd., registered with the CNPJ (National Registry of Legal Entities)
under Number 52.605.821/0001-55, located at 3526 Dr. Labieno da
Costa Machado Avenue, Industrial District, Garça – SP – Brazil, Zip
Code 17400-000, manufacturer of PPA Products, hereby
guarantees this product against design, manufacturing or assembly
defects and/or supportively as a result of material quality flaws that
could make its intended use improper or inadequate, within a legal
period of ninety days from time of acquisition, provided that the
installation instructions described in the instruction manual are
observed.
Due to the credibility and trust placed on PPA products, we will add
275 more days to the period mentioned above, reaching a warranty
period of one year, likewise counted from the time of acquisition
proven by consumer through proof of purchase (Customer Receipt).
In case of defect, within the warranty period, PPA responsibilities are
restricted to the repair or substitution of the product manufactured by
the company, under the following conditions:
1. Repair and readjustment of equipment may only be carried
out by PPA Technical Assistance, which is qualified to open,
remove, and substitute parts or components, as well as repair
defects covered by this warranty; thus, failure on observing
this guideline and the verified use of any non-original parts will
cause the resignation of this warranty on the part of the user;
2. The warranty will not extend to accessories such as cables,
screw kit, fixing brackets, power supplies etc.;
3. Expenses for packaging, transportation and product
reinstallation will be sole responsibility of the consumer;
4. The equipment must be sent directly to the Company
responsible for the sale (manufacturer's representative),
through the address contained in the purchase invoice,
properly packed, thus avoiding loss of the warranty;
5. Within the additional period of 275 days, visits and
transportation in places where authorized technical
assistance is not available will be charged. The cost of
transportation of the product and/or technician will be sole
responsibility of the consumer and
6. The substitution or repair of the product does not prolong the
warranty time.
This warranty will be terminated if the product:
1. Is damaged by natural agents, such as atmospheric
discharges, floods, wildfires, landslides etc.;
2. Is installed in an improper electric power supply or if it is not
according to any of the installation instructions displayed on
the manual;
3. Shows defects caused by droppings, collisions or any other
physical accident;
4. Shows signs of product violation or attempted repair by
unauthorized personnel;
5. Is not used for its intended purpose;
6. Is not used under normal conditions;
7. Is damaged by accessories or equipment connected to it.
Recommendation:
We recommend that both the installation and the maintenance of the
operator to be performed by an authorized PPA technical service. If
the product fails or has an improper operation, seek an Authorized
Technical Service to fix it..

C36 Smart Alarm
Self-monitored alarm board by Android and IOS app with sending
notification in real time, automation and integration with the PPA On line
through the internet via a Wi-Fi connection. Fast and simple registration,
intuitive operation.
Main features:
- Equipped with switched power supply;
- Siren output;
- 12V 7Ah battery charger;
- 1 configurable auxiliary output;
- 4 wired zones;
- Up to 32 wireless zones;
- Up to 32 remote controls;
- Internal, intelligent, timed and 24h zones;
- Internal arming by control key;
- Led (armed and disarmed status);
- Programmable siren time;
- Programmable exit time;
- Programmable entry time;
- Configurable arm/disarm beep;
- Shutdown function on sensors and zones (ignores after 4 shots);
- Monitors battery and power failure;
- Protection against battery short.
Technical features:
Power: 90-240Vac;
Battery: Lead acid 12V 7Ah;
Wi-Fi communication: 802.11 b/g/n 2.4GHz standard;
Wireless Sensors: Open Standard, Fixed Code Compatible with HT6P20;
Remote controls: PPA rolling code, anti-cloning;
Consumption: 300 mA (max);
Dimensions: 230x240x100mm (HxWxD);
Weight: 690g.
Leds:
POWER: Power indicator on source input
STATUS PROG: Reception indicator from a wireless remote control or
sensor
PROG WIFI: WiFi connection status indicator.
Off = Initializing / Offline
Fast flashing = Smart registration mode.
Slow flashing = AP registration mode.
Flashing 1 time = Searching for Wi-Fi signal.
Flashing 2 times = Searching cloud server.
On = Connected to Wi-Fi and cloud.
STATUS: Armed board indicator (On) Disarmed (Off) Shooting (Flashing)
Keys:
PROG: Learning remote controls / Wi-fi connection setup, follow the
app instructions.
APRENDER: Learn wireless sensors / Reset to factory default.
Connections:
CN2: Switched source input of the board.
12V / GND: Power output for sensors.
Z1: Zone 1 wired sensor input. Can be disabled by closing jumper Z1.
Z2: Zone 2 wired sensor input. Can be disabled by closing jumper Z2
Z3: Zone 3 wired sensor input. Can be disabled by closing jumper Z3
Z4: Zone 4 wired sensor input. Can be disabled by closing jumper Z4
SIRENE / GND : Connection to siren.
NA: Auxiliary relay normally open contact.
CO: Auxiliary relay common contact.
NF: normally closed contact of the auxiliary relay.
Operation:
Wireless sensors programming: With the board in Disarmed mode.
Press the 'Learn' key briefly, 'Status Prog' LED flashes quickly. Trigger the
wireless sensor.
Programming the remote controls: With the board in Disarmed mode.
Press 'Prog' key briefly, 'Status Prog' LED flashes quickly. Press a button
on the remote.
Product description:
Panic Trigger: Press any key on a remote control registered and hold for
3s or more.
Reset to Factory Default: Press the 'Learn' key and the keep it pressed
for 15s until the 'Status Prog' led turns on. All remote controls and
sensors will be erased and settings will return to factory defaults. (WiFi
connection setting is not affected).
Trigger: When there is a sensor violation or panic trigger, the board will
activate the siren for the programmed time (default 5 min), the STATUS
led flashes fast indicating the trigger until the board is disarmed or
rearmed.
Auxiliary Relay: The auxiliary relay provides a dry contact output for
trigger loads such as high-powered lamps, sirens, or provide status to
other equipment. Its default operation is to trigger along with the siren
output and can be customized in the app as to triggering time and mode.
The possible trigger modes are: Trigger with the control panel disarmed,
with the board armed, with the internal arming and with the trigger.
Sensor inputs: (Z1, Z2, Z3, Z4). One or more wired sensors can be
connected between terminals Z(1-4) and GND. It will be considered
violated if the connection is interrupted.
Jumpers Z(1-4): If closed, deactivate the zone corresponding Z(1-4).
Unused zones must be disabled.
Siren Output: The output is suitable for connecting one or more sirens
with total consumption of up to 1A. If this output goes into a short circuit
or presents a very high consumption due to a defect or an attempt at
sabotage, the “Siren Sensor” will be violated and the board will be
triggered. In this situation, it is ideal to have a second siren installed with
the PGM relay in the “Start with siren” mode.
Application:
Search the store for the 'PPA ON' app.
Create the account in the app.
Add a device.-> Alarm (Wi-Fi)
Keep the cell phone close to the module at the installation site. Check
that the signal level of the mobile Wi-Fi network is good.
Press the PROG button for 5s.
Follow the onscreen instructions.
WARNING:
Do not use the equipment
without referring to this
manual rst.
P30394 - 10/2022
Rev. 1
MANUAL
C36 SMART
ALARM
Historic:
Displays the history of the latest
alarm events, like arming,
disarming, shooting, etc..
Accessories:
Screen for registration and
consultation of accessories
(wired and wireless sensors and
remote controls).
PPA
Restart device first
If the Wifi Led (Blue) is flashing quickly,
skip the reset step.
1 On
2 Press the PROG button for 5 seconds
3 Make sure the Wifi Led (Blue) is flashing
quickly
Confirm that the Wifi Led (Blue)
is flashing quickly
Select a 2.4GHz Wi-Fi network
and enter the password.
If Wi-fi is 5GHz, set it to 2.4GHz before
proceeding. Common method of
router configuration.
Add device
Make sure the device is turned on
Accessories Accessories
Wireless Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 1?
Unknown 2?
Unknown 3?
Sensor Remote Control Sensor Remote Control
Wired Sensor Wired Sensor
Standard Control
Cancel
Cancel
Cancel
EZ mode
Restart devices
Next
Password
Next
Analyze
the devices
Register the
device on
the Cloud
Start
the device
Accessory Types:
Wireless Sensor: Sensors and remote controls with fixed code for panic
triggering. The board allows up to 32 devices of this type.
Remote Control: Remote Controls with Rolling Code Compatible with
PPA. (Ex.: ZAP4 and Slim models). Up to 32 registered remotes are
allowed.
Wired Sensor: Inputs for wired switchboard sensors (Z1,Z2,Z3 and Z4)
and siren sensor. When deleted, these devices return to the factory
default settings.
Zone Type:
Immediate: Default zone type, triggers the siren and sends notification
if the switch is armed.
Internal: Special zone for motion sensors and interior doors, which do
not trigger when the alarm is in 'Internal Arm' mode. Ideal for when the
alarm is armed with residents within the protected perimeter.
24 Hours: Zone that triggers the siren and notification at all times, even
with the alarm in 'Disarmed' mode, ideal for use with panic devices and
perimeter sensors such as electric fence alarm outputs.
Delayed: Zone that ignores triggers within the tolerance time for input
and/or output programmed into the system.
Follower: This zone type behaves like an Immediate zone normally,
however, it becomes a Delayed zone if a Delayed type zone is in time
count.
Zone Attribute:
None: Standard operation.
Smart: With this attribute type there must be 2 openings in the zone in
less than 1 minute or an opening lasting longer than 1 minute to be
considered a violation. It is generally used to prevent false triggering on
some types of wired sensors. Has no effect on wireless sensors.
Silent: When triggering it does not trigger the siren, but sends the
notification to the application normally.
Not Self Bypassing: The zone does not obey the autobypass rule after 4
shots.
Add
Tipo: Movimiento
Zona: Normal
Tipo: Movimiento
Zona: Normal
Status: Normal
Status: Normal
Desconocido 2?
Desconocido 3?
Delete/Edit name
Accessories
Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 2?
Unknown 3?
Sensor Remote Control
Wired Sensor
Slide left
Settings:
Arm/Disarm Sound: Activates the Arm or Disarm notification function
disarm the board by the siren output. It emits two beeps to indicate
board disarming and one beep to indicate disarming. The PGM output
does not trigger in this case even if it is in the “Sir with Siren” mode.
PGM Output Mode: Selects the relay triggering condition PGM.
Possible conditions: Trigger with siren, Trigger in Arming mode,
Triggering in Internal Arming mode or Triggering in Disarmed mode.
PGM output: (Enabled / Disabled) Indicates whether the siren must be
activated in case of a trip.
PGM time: Time in minutes for activating the PGM output. After the
configured time, the output is deactivated. A time equal to zero indicates
triggering with hold (infinite as long as the triggering condition remains).
Siren Trigger Time: Time in minutes for activating the siren. After the
configured time, the siren is deactivated.
Siren Output: (Enabled / Disabled) Indicates whether the Siren must be
activated in the event of a trip.
Entry Delay: Tolerance time for triggering 'Delayed' type zones after
their violation. It is commonly used to allow the user to enter within the
perimeter and have a short period of time to disarm the switch without
firing it.
Exit Time: Tolerance time for triggering zones of the type after the
switch is placed in 'Arm' or 'Internal Arm' mode. Violations in sensors in
these zones within the programmed time do not trigger the switch. It is
used to allow the user to arm the switch when leaving the secured
perimeter.
Made by:
Motoppar Indústria e Comércio de Automatizadores Ltda
Av. Dr. Labieno da Costa Machado, 3526 - Distrito Industrial
Garça - SP - CEP 17406-200 - Brasil
CNPJ: 52.605.821/0001-55
www.ppa.com.br | +55 14 3407 1000
GENERAL TERMS AND CONDITIONS OF WARRANTY
MOTOPPAR, Industry and Commerce of Automatic Gate Operators
Ltd., registered with the CNPJ (National Registry of Legal Entities)
under Number 52.605.821/0001-55, located at 3526 Dr. Labieno da
Costa Machado Avenue, Industrial District, Garça – SP – Brazil, Zip
Code 17400-000, manufacturer of PPA Products, hereby
guarantees this product against design, manufacturing or assembly
defects and/or supportively as a result of material quality flaws that
could make its intended use improper or inadequate, within a legal
period of ninety days from time of acquisition, provided that the
installation instructions described in the instruction manual are
observed.
Due to the credibility and trust placed on PPA products, we will add
275 more days to the period mentioned above, reaching a warranty
period of one year, likewise counted from the time of acquisition
proven by consumer through proof of purchase (Customer Receipt).
In case of defect, within the warranty period, PPA responsibilities are
restricted to the repair or substitution of the product manufactured by
the company, under the following conditions:
1. Repair and readjustment of equipment may only be carried
out by PPA Technical Assistance, which is qualified to open,
remove, and substitute parts or components, as well as repair
defects covered by this warranty; thus, failure on observing
this guideline and the verified use of any non-original parts will
cause the resignation of this warranty on the part of the user;
2. The warranty will not extend to accessories such as cables,
screw kit, fixing brackets, power supplies etc.;
3. Expenses for packaging, transportation and product
reinstallation will be sole responsibility of the consumer;
4. The equipment must be sent directly to the Company
responsible for the sale (manufacturer's representative),
through the address contained in the purchase invoice,
properly packed, thus avoiding loss of the warranty;
5. Within the additional period of 275 days, visits and
transportation in places where authorized technical
assistance is not available will be charged. The cost of
transportation of the product and/or technician will be sole
responsibility of the consumer and
6. The substitution or repair of the product does not prolong the
warranty time.
This warranty will be terminated if the product:
1. Is damaged by natural agents, such as atmospheric
discharges, floods, wildfires, landslides etc.;
2. Is installed in an improper electric power supply or if it is not
according to any of the installation instructions displayed on
the manual;
3. Shows defects caused by droppings, collisions or any other
physical accident;
4. Shows signs of product violation or attempted repair by
unauthorized personnel;
5. Is not used for its intended purpose;
6. Is not used under normal conditions;
7. Is damaged by accessories or equipment connected to it.
Recommendation:
We recommend that both the installation and the maintenance of the
operator to be performed by an authorized PPA technical service. If
the product fails or has an improper operation, seek an Authorized
Technical Service to fix it..

C36 Smart Alarm
Self-monitored alarm board by Android and IOS app with sending
notification in real time, automation and integration with the PPA On line
through the internet via a Wi-Fi connection. Fast and simple registration,
intuitive operation.
Main features:
- Equipped with switched power supply;
- Siren output;
- 12V 7Ah battery charger;
- 1 configurable auxiliary output;
- 4 wired zones;
- Up to 32 wireless zones;
- Up to 32 remote controls;
- Internal, intelligent, timed and 24h zones;
- Internal arming by control key;
- Led (armed and disarmed status);
- Programmable siren time;
- Programmable exit time;
- Programmable entry time;
- Configurable arm/disarm beep;
- Shutdown function on sensors and zones (ignores after 4 shots);
- Monitors battery and power failure;
- Protection against battery short.
Technical features:
Power: 90-240Vac;
Battery: Lead acid 12V 7Ah;
Wi-Fi communication: 802.11 b/g/n 2.4GHz standard;
Wireless Sensors: Open Standard, Fixed Code Compatible with HT6P20;
Remote controls: PPA rolling code, anti-cloning;
Consumption: 300 mA (max);
Dimensions: 230x240x100mm (HxWxD);
Weight: 690g.
Leds:
POWER: Power indicator on source input
STATUS PROG: Reception indicator from a wireless remote control or
sensor
PROG WIFI: WiFi connection status indicator.
Off = Initializing / Offline
Fast flashing = Smart registration mode.
Slow flashing = AP registration mode.
Flashing 1 time = Searching for Wi-Fi signal.
Flashing 2 times = Searching cloud server.
On = Connected to Wi-Fi and cloud.
STATUS: Armed board indicator (On) Disarmed (Off) Shooting (Flashing)
Keys:
PROG: Learning remote controls / Wi-fi connection setup, follow the
app instructions.
APRENDER: Learn wireless sensors / Reset to factory default.
Connections:
CN2: Switched source input of the board.
12V / GND: Power output for sensors.
Z1: Zone 1 wired sensor input. Can be disabled by closing jumper Z1.
Z2: Zone 2 wired sensor input. Can be disabled by closing jumper Z2
Z3: Zone 3 wired sensor input. Can be disabled by closing jumper Z3
Z4: Zone 4 wired sensor input. Can be disabled by closing jumper Z4
SIRENE / GND : Connection to siren.
NA: Auxiliary relay normally open contact.
CO: Auxiliary relay common contact.
NF: normally closed contact of the auxiliary relay.
Operation:
Wireless sensors programming: With the board in Disarmed mode.
Press the 'Learn' key briefly, 'Status Prog' LED flashes quickly. Trigger the
wireless sensor.
Programming the remote controls: With the board in Disarmed mode.
Press 'Prog' key briefly, 'Status Prog' LED flashes quickly. Press a button
on the remote.
Product description:
Panic Trigger: Press any key on a remote control registered and hold for
3s or more.
Reset to Factory Default: Press the 'Learn' key and the keep it pressed
for 15s until the 'Status Prog' led turns on. All remote controls and
sensors will be erased and settings will return to factory defaults. (WiFi
connection setting is not affected).
Trigger: When there is a sensor violation or panic trigger, the board will
activate the siren for the programmed time (default 5 min), the STATUS
led flashes fast indicating the trigger until the board is disarmed or
rearmed.
Auxiliary Relay: The auxiliary relay provides a dry contact output for
trigger loads such as high-powered lamps, sirens, or provide status to
other equipment. Its default operation is to trigger along with the siren
output and can be customized in the app as to triggering time and mode.
The possible trigger modes are: Trigger with the control panel disarmed,
with the board armed, with the internal arming and with the trigger.
Sensor inputs: (Z1, Z2, Z3, Z4). One or more wired sensors can be
connected between terminals Z(1-4) and GND. It will be considered
violated if the connection is interrupted.
Jumpers Z(1-4): If closed, deactivate the zone corresponding Z(1-4).
Unused zones must be disabled.
Siren Output: The output is suitable for connecting one or more sirens
with total consumption of up to 1A. If this output goes into a short circuit
or presents a very high consumption due to a defect or an attempt at
sabotage, the “Siren Sensor” will be violated and the board will be
triggered. In this situation, it is ideal to have a second siren installed with
the PGM relay in the “Start with siren” mode.
Application:
Search the store for the 'PPA ON' app.
Create the account in the app.
Add a device.-> Alarm (Wi-Fi)
Keep the cell phone close to the module at the installation site. Check
that the signal level of the mobile Wi-Fi network is good.
Press the PROG button for 5s.
Follow the onscreen instructions.
WARNING:
Do not use the equipment
without referring to this
manual rst.
P30394 - 10/2022
Rev. 1
MANUAL
C36 SMART
ALARM
Historic:
Displays the history of the latest
alarm events, like arming,
disarming, shooting, etc..
Accessories:
Screen for registration and
consultation of accessories
(wired and wireless sensors and
remote controls).
PPA
Restart device first
If the Wifi Led (Blue) is flashing quickly,
skip the reset step.
1 On
2 Press the PROG button for 5 seconds
3 Make sure the Wifi Led (Blue) is flashing
quickly
Confirm that the Wifi Led (Blue)
is flashing quickly
Select a 2.4GHz Wi-Fi network
and enter the password.
If Wi-fi is 5GHz, set it to 2.4GHz before
proceeding. Common method of
router configuration.
Add device
Make sure the device is turned on
Accessories Accessories
Wireless Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 1?
Unknown 2?
Unknown 3?
Sensor Remote Control Sensor Remote Control
Wired Sensor Wired Sensor
Standard Control
Cancel
Cancel
Cancel
EZ mode
Restart devices
Next
Password
Next
Analyze
the devices
Register the
device on
the Cloud
Start
the device
Accessory Types:
Wireless Sensor: Sensors and remote controls with fixed code for panic
triggering. The board allows up to 32 devices of this type.
Remote Control: Remote Controls with Rolling Code Compatible with
PPA. (Ex.: ZAP4 and Slim models). Up to 32 registered remotes are
allowed.
Wired Sensor: Inputs for wired switchboard sensors (Z1,Z2,Z3 and Z4)
and siren sensor. When deleted, these devices return to the factory
default settings.
Zone Type:
Immediate: Default zone type, triggers the siren and sends notification
if the switch is armed.
Internal: Special zone for motion sensors and interior doors, which do
not trigger when the alarm is in 'Internal Arm' mode. Ideal for when the
alarm is armed with residents within the protected perimeter.
24 Hours: Zone that triggers the siren and notification at all times, even
with the alarm in 'Disarmed' mode, ideal for use with panic devices and
perimeter sensors such as electric fence alarm outputs.
Delayed: Zone that ignores triggers within the tolerance time for input
and/or output programmed into the system.
Follower: This zone type behaves like an Immediate zone normally,
however, it becomes a Delayed zone if a Delayed type zone is in time
count.
Zone Attribute:
None: Standard operation.
Smart: With this attribute type there must be 2 openings in the zone in
less than 1 minute or an opening lasting longer than 1 minute to be
considered a violation. It is generally used to prevent false triggering on
some types of wired sensors. Has no effect on wireless sensors.
Silent: When triggering it does not trigger the siren, but sends the
notification to the application normally.
Not Self Bypassing: The zone does not obey the autobypass rule after 4
shots.
Add
Tipo: Movimiento
Zona: Normal
Tipo: Movimiento
Zona: Normal
Status: Normal
Status: Normal
Desconocido 2?
Desconocido 3?
Delete/Edit name
Accessories
Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 2?
Unknown 3?
Sensor Remote Control
Wired Sensor
Slide left
Settings:
Arm/Disarm Sound: Activates the Arm or Disarm notification function
disarm the board by the siren output. It emits two beeps to indicate
board disarming and one beep to indicate disarming. The PGM output
does not trigger in this case even if it is in the “Sir with Siren” mode.
PGM Output Mode: Selects the relay triggering condition PGM.
Possible conditions: Trigger with siren, Trigger in Arming mode,
Triggering in Internal Arming mode or Triggering in Disarmed mode.
PGM output: (Enabled / Disabled) Indicates whether the siren must be
activated in case of a trip.
PGM time: Time in minutes for activating the PGM output. After the
configured time, the output is deactivated. A time equal to zero indicates
triggering with hold (infinite as long as the triggering condition remains).
Siren Trigger Time: Time in minutes for activating the siren. After the
configured time, the siren is deactivated.
Siren Output: (Enabled / Disabled) Indicates whether the Siren must be
activated in the event of a trip.
Entry Delay: Tolerance time for triggering 'Delayed' type zones after
their violation. It is commonly used to allow the user to enter within the
perimeter and have a short period of time to disarm the switch without
firing it.
Exit Time: Tolerance time for triggering zones of the type after the
switch is placed in 'Arm' or 'Internal Arm' mode. Violations in sensors in
these zones within the programmed time do not trigger the switch. It is
used to allow the user to arm the switch when leaving the secured
perimeter.
Made by:
Motoppar Indústria e Comércio de Automatizadores Ltda
Av. Dr. Labieno da Costa Machado, 3526 - Distrito Industrial
Garça - SP - CEP 17406-200 - Brasil
CNPJ: 52.605.821/0001-55
www.ppa.com.br | +55 14 3407 1000
GENERAL TERMS AND CONDITIONS OF WARRANTY
MOTOPPAR, Industry and Commerce of Automatic Gate Operators
Ltd., registered with the CNPJ (National Registry of Legal Entities)
under Number 52.605.821/0001-55, located at 3526 Dr. Labieno da
Costa Machado Avenue, Industrial District, Garça – SP – Brazil, Zip
Code 17400-000, manufacturer of PPA Products, hereby
guarantees this product against design, manufacturing or assembly
defects and/or supportively as a result of material quality flaws that
could make its intended use improper or inadequate, within a legal
period of ninety days from time of acquisition, provided that the
installation instructions described in the instruction manual are
observed.
Due to the credibility and trust placed on PPA products, we will add
275 more days to the period mentioned above, reaching a warranty
period of one year, likewise counted from the time of acquisition
proven by consumer through proof of purchase (Customer Receipt).
In case of defect, within the warranty period, PPA responsibilities are
restricted to the repair or substitution of the product manufactured by
the company, under the following conditions:
1. Repair and readjustment of equipment may only be carried
out by PPA Technical Assistance, which is qualified to open,
remove, and substitute parts or components, as well as repair
defects covered by this warranty; thus, failure on observing
this guideline and the verified use of any non-original parts will
cause the resignation of this warranty on the part of the user;
2. The warranty will not extend to accessories such as cables,
screw kit, fixing brackets, power supplies etc.;
3. Expenses for packaging, transportation and product
reinstallation will be sole responsibility of the consumer;
4. The equipment must be sent directly to the Company
responsible for the sale (manufacturer's representative),
through the address contained in the purchase invoice,
properly packed, thus avoiding loss of the warranty;
5. Within the additional period of 275 days, visits and
transportation in places where authorized technical
assistance is not available will be charged. The cost of
transportation of the product and/or technician will be sole
responsibility of the consumer and
6. The substitution or repair of the product does not prolong the
warranty time.
This warranty will be terminated if the product:
1. Is damaged by natural agents, such as atmospheric
discharges, floods, wildfires, landslides etc.;
2. Is installed in an improper electric power supply or if it is not
according to any of the installation instructions displayed on
the manual;
3. Shows defects caused by droppings, collisions or any other
physical accident;
4. Shows signs of product violation or attempted repair by
unauthorized personnel;
5. Is not used for its intended purpose;
6. Is not used under normal conditions;
7. Is damaged by accessories or equipment connected to it.
Recommendation:
We recommend that both the installation and the maintenance of the
operator to be performed by an authorized PPA technical service. If
the product fails or has an improper operation, seek an Authorized
Technical Service to fix it..

C36 Smart Alarm
Self-monitored alarm board by Android and IOS app with sending
notification in real time, automation and integration with the PPA On line
through the internet via a Wi-Fi connection. Fast and simple registration,
intuitive operation.
Main features:
- Equipped with switched power supply;
- Siren output;
- 12V 7Ah battery charger;
- 1 configurable auxiliary output;
- 4 wired zones;
- Up to 32 wireless zones;
- Up to 32 remote controls;
- Internal, intelligent, timed and 24h zones;
- Internal arming by control key;
- Led (armed and disarmed status);
- Programmable siren time;
- Programmable exit time;
- Programmable entry time;
- Configurable arm/disarm beep;
- Shutdown function on sensors and zones (ignores after 4 shots);
- Monitors battery and power failure;
- Protection against battery short.
Technical features:
Power: 90-240Vac;
Battery: Lead acid 12V 7Ah;
Wi-Fi communication: 802.11 b/g/n 2.4GHz standard;
Wireless Sensors: Open Standard, Fixed Code Compatible with HT6P20;
Remote controls: PPA rolling code, anti-cloning;
Consumption: 300 mA (max);
Dimensions: 230x240x100mm (HxWxD);
Weight: 690g.
Leds:
POWER: Power indicator on source input
STATUS PROG: Reception indicator from a wireless remote control or
sensor
PROG WIFI: WiFi connection status indicator.
Off = Initializing / Offline
Fast flashing = Smart registration mode.
Slow flashing = AP registration mode.
Flashing 1 time = Searching for Wi-Fi signal.
Flashing 2 times = Searching cloud server.
On = Connected to Wi-Fi and cloud.
STATUS: Armed board indicator (On) Disarmed (Off) Shooting (Flashing)
Keys:
PROG: Learning remote controls / Wi-fi connection setup, follow the
app instructions.
APRENDER: Learn wireless sensors / Reset to factory default.
Connections:
CN2: Switched source input of the board.
12V / GND: Power output for sensors.
Z1: Zone 1 wired sensor input. Can be disabled by closing jumper Z1.
Z2: Zone 2 wired sensor input. Can be disabled by closing jumper Z2
Z3: Zone 3 wired sensor input. Can be disabled by closing jumper Z3
Z4: Zone 4 wired sensor input. Can be disabled by closing jumper Z4
SIRENE / GND : Connection to siren.
NA: Auxiliary relay normally open contact.
CO: Auxiliary relay common contact.
NF: normally closed contact of the auxiliary relay.
Operation:
Wireless sensors programming: With the board in Disarmed mode.
Press the 'Learn' key briefly, 'Status Prog' LED flashes quickly. Trigger the
wireless sensor.
Programming the remote controls: With the board in Disarmed mode.
Press 'Prog' key briefly, 'Status Prog' LED flashes quickly. Press a button
on the remote.
Product description:
Panic Trigger: Press any key on a remote control registered and hold for
3s or more.
Reset to Factory Default: Press the 'Learn' key and the keep it pressed
for 15s until the 'Status Prog' led turns on. All remote controls and
sensors will be erased and settings will return to factory defaults. (WiFi
connection setting is not affected).
Trigger: When there is a sensor violation or panic trigger, the board will
activate the siren for the programmed time (default 5 min), the STATUS
led flashes fast indicating the trigger until the board is disarmed or
rearmed.
Auxiliary Relay: The auxiliary relay provides a dry contact output for
trigger loads such as high-powered lamps, sirens, or provide status to
other equipment. Its default operation is to trigger along with the siren
output and can be customized in the app as to triggering time and mode.
The possible trigger modes are: Trigger with the control panel disarmed,
with the board armed, with the internal arming and with the trigger.
Sensor inputs: (Z1, Z2, Z3, Z4). One or more wired sensors can be
connected between terminals Z(1-4) and GND. It will be considered
violated if the connection is interrupted.
Jumpers Z(1-4): If closed, deactivate the zone corresponding Z(1-4).
Unused zones must be disabled.
Siren Output: The output is suitable for connecting one or more sirens
with total consumption of up to 1A. If this output goes into a short circuit
or presents a very high consumption due to a defect or an attempt at
sabotage, the “Siren Sensor” will be violated and the board will be
triggered. In this situation, it is ideal to have a second siren installed with
the PGM relay in the “Start with siren” mode.
Application:
Search the store for the 'PPA ON' app.
Create the account in the app.
Add a device.-> Alarm (Wi-Fi)
Keep the cell phone close to the module at the installation site. Check
that the signal level of the mobile Wi-Fi network is good.
Press the PROG button for 5s.
Follow the onscreen instructions.
WARNING:
Do not use the equipment
without referring to this
manual rst.
P30394 - 10/2022
Rev. 1
MANUAL
C36 SMART
ALARM
Historic:
Displays the history of the latest
alarm events, like arming,
disarming, shooting, etc..
Accessories:
Screen for registration and
consultation of accessories
(wired and wireless sensors and
remote controls).
PPA
Restart device first
If the Wifi Led (Blue) is flashing quickly,
skip the reset step.
1 On
2 Press the PROG button for 5 seconds
3 Make sure the Wifi Led (Blue) is flashing
quickly
Confirm that the Wifi Led (Blue)
is flashing quickly
Select a 2.4GHz Wi-Fi network
and enter the password.
If Wi-fi is 5GHz, set it to 2.4GHz before
proceeding. Common method of
router configuration.
Add device
Make sure the device is turned on
Accessories Accessories
Wireless Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 1?
Unknown 2?
Unknown 3?
Sensor Remote Control Sensor Remote Control
Wired Sensor Wired Sensor
Standard Control
Cancel
Cancel
Cancel
EZ mode
Restart devices
Next
Password
Next
Analyze
the devices
Register the
device on
the Cloud
Start
the device
Accessory Types:
Wireless Sensor: Sensors and remote controls with fixed code for panic
triggering. The board allows up to 32 devices of this type.
Remote Control: Remote Controls with Rolling Code Compatible with
PPA. (Ex.: ZAP4 and Slim models). Up to 32 registered remotes are
allowed.
Wired Sensor: Inputs for wired switchboard sensors (Z1,Z2,Z3 and Z4)
and siren sensor. When deleted, these devices return to the factory
default settings.
Zone Type:
Immediate: Default zone type, triggers the siren and sends notification
if the switch is armed.
Internal: Special zone for motion sensors and interior doors, which do
not trigger when the alarm is in 'Internal Arm' mode. Ideal for when the
alarm is armed with residents within the protected perimeter.
24 Hours: Zone that triggers the siren and notification at all times, even
with the alarm in 'Disarmed' mode, ideal for use with panic devices and
perimeter sensors such as electric fence alarm outputs.
Delayed: Zone that ignores triggers within the tolerance time for input
and/or output programmed into the system.
Follower: This zone type behaves like an Immediate zone normally,
however, it becomes a Delayed zone if a Delayed type zone is in time
count.
Zone Attribute:
None: Standard operation.
Smart: With this attribute type there must be 2 openings in the zone in
less than 1 minute or an opening lasting longer than 1 minute to be
considered a violation. It is generally used to prevent false triggering on
some types of wired sensors. Has no effect on wireless sensors.
Silent: When triggering it does not trigger the siren, but sends the
notification to the application normally.
Not Self Bypassing: The zone does not obey the autobypass rule after 4
shots.
Add
Tipo: Movimiento
Zona: Normal
Tipo: Movimiento
Zona: Normal
Status: Normal
Status: Normal
Desconocido 2?
Desconocido 3?
Delete/Edit name
Accessories
Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 2?
Unknown 3?
Sensor Remote Control
Wired Sensor
Slide left
Settings:
Arm/Disarm Sound: Activates the Arm or Disarm notification function
disarm the board by the siren output. It emits two beeps to indicate
board disarming and one beep to indicate disarming. The PGM output
does not trigger in this case even if it is in the “Sir with Siren” mode.
PGM Output Mode: Selects the relay triggering condition PGM.
Possible conditions: Trigger with siren, Trigger in Arming mode,
Triggering in Internal Arming mode or Triggering in Disarmed mode.
PGM output: (Enabled / Disabled) Indicates whether the siren must be
activated in case of a trip.
PGM time: Time in minutes for activating the PGM output. After the
configured time, the output is deactivated. A time equal to zero indicates
triggering with hold (infinite as long as the triggering condition remains).
Siren Trigger Time: Time in minutes for activating the siren. After the
configured time, the siren is deactivated.
Siren Output: (Enabled / Disabled) Indicates whether the Siren must be
activated in the event of a trip.
Entry Delay: Tolerance time for triggering 'Delayed' type zones after
their violation. It is commonly used to allow the user to enter within the
perimeter and have a short period of time to disarm the switch without
firing it.
Exit Time: Tolerance time for triggering zones of the type after the
switch is placed in 'Arm' or 'Internal Arm' mode. Violations in sensors in
these zones within the programmed time do not trigger the switch. It is
used to allow the user to arm the switch when leaving the secured
perimeter.
Made by:
Motoppar Indústria e Comércio de Automatizadores Ltda
Av. Dr. Labieno da Costa Machado, 3526 - Distrito Industrial
Garça - SP - CEP 17406-200 - Brasil
CNPJ: 52.605.821/0001-55
www.ppa.com.br | +55 14 3407 1000
GENERAL TERMS AND CONDITIONS OF WARRANTY
MOTOPPAR, Industry and Commerce of Automatic Gate Operators
Ltd., registered with the CNPJ (National Registry of Legal Entities)
under Number 52.605.821/0001-55, located at 3526 Dr. Labieno da
Costa Machado Avenue, Industrial District, Garça – SP – Brazil, Zip
Code 17400-000, manufacturer of PPA Products, hereby
guarantees this product against design, manufacturing or assembly
defects and/or supportively as a result of material quality flaws that
could make its intended use improper or inadequate, within a legal
period of ninety days from time of acquisition, provided that the
installation instructions described in the instruction manual are
observed.
Due to the credibility and trust placed on PPA products, we will add
275 more days to the period mentioned above, reaching a warranty
period of one year, likewise counted from the time of acquisition
proven by consumer through proof of purchase (Customer Receipt).
In case of defect, within the warranty period, PPA responsibilities are
restricted to the repair or substitution of the product manufactured by
the company, under the following conditions:
1. Repair and readjustment of equipment may only be carried
out by PPA Technical Assistance, which is qualified to open,
remove, and substitute parts or components, as well as repair
defects covered by this warranty; thus, failure on observing
this guideline and the verified use of any non-original parts will
cause the resignation of this warranty on the part of the user;
2. The warranty will not extend to accessories such as cables,
screw kit, fixing brackets, power supplies etc.;
3. Expenses for packaging, transportation and product
reinstallation will be sole responsibility of the consumer;
4. The equipment must be sent directly to the Company
responsible for the sale (manufacturer's representative),
through the address contained in the purchase invoice,
properly packed, thus avoiding loss of the warranty;
5. Within the additional period of 275 days, visits and
transportation in places where authorized technical
assistance is not available will be charged. The cost of
transportation of the product and/or technician will be sole
responsibility of the consumer and
6. The substitution or repair of the product does not prolong the
warranty time.
This warranty will be terminated if the product:
1. Is damaged by natural agents, such as atmospheric
discharges, floods, wildfires, landslides etc.;
2. Is installed in an improper electric power supply or if it is not
according to any of the installation instructions displayed on
the manual;
3. Shows defects caused by droppings, collisions or any other
physical accident;
4. Shows signs of product violation or attempted repair by
unauthorized personnel;
5. Is not used for its intended purpose;
6. Is not used under normal conditions;
7. Is damaged by accessories or equipment connected to it.
Recommendation:
We recommend that both the installation and the maintenance of the
operator to be performed by an authorized PPA technical service. If
the product fails or has an improper operation, seek an Authorized
Technical Service to fix it..

C36 Smart Alarm
Self-monitored alarm board by Android and IOS app with sending
notification in real time, automation and integration with the PPA On line
through the internet via a Wi-Fi connection. Fast and simple registration,
intuitive operation.
Main features:
- Equipped with switched power supply;
- Siren output;
- 12V 7Ah battery charger;
- 1 configurable auxiliary output;
- 4 wired zones;
- Up to 32 wireless zones;
- Up to 32 remote controls;
- Internal, intelligent, timed and 24h zones;
- Internal arming by control key;
- Led (armed and disarmed status);
- Programmable siren time;
- Programmable exit time;
- Programmable entry time;
- Configurable arm/disarm beep;
- Shutdown function on sensors and zones (ignores after 4 shots);
- Monitors battery and power failure;
- Protection against battery short.
Technical features:
Power: 90-240Vac;
Battery: Lead acid 12V 7Ah;
Wi-Fi communication: 802.11 b/g/n 2.4GHz standard;
Wireless Sensors: Open Standard, Fixed Code Compatible with HT6P20;
Remote controls: PPA rolling code, anti-cloning;
Consumption: 300 mA (max);
Dimensions: 230x240x100mm (HxWxD);
Weight: 690g.
Leds:
POWER: Power indicator on source input
STATUS PROG: Reception indicator from a wireless remote control or
sensor
PROG WIFI: WiFi connection status indicator.
Off = Initializing / Offline
Fast flashing = Smart registration mode.
Slow flashing = AP registration mode.
Flashing 1 time = Searching for Wi-Fi signal.
Flashing 2 times = Searching cloud server.
On = Connected to Wi-Fi and cloud.
STATUS: Armed board indicator (On) Disarmed (Off) Shooting (Flashing)
Keys:
PROG: Learning remote controls / Wi-fi connection setup, follow the
app instructions.
APRENDER: Learn wireless sensors / Reset to factory default.
Connections:
CN2: Switched source input of the board.
12V / GND: Power output for sensors.
Z1: Zone 1 wired sensor input. Can be disabled by closing jumper Z1.
Z2: Zone 2 wired sensor input. Can be disabled by closing jumper Z2
Z3: Zone 3 wired sensor input. Can be disabled by closing jumper Z3
Z4: Zone 4 wired sensor input. Can be disabled by closing jumper Z4
SIRENE / GND : Connection to siren.
NA: Auxiliary relay normally open contact.
CO: Auxiliary relay common contact.
NF: normally closed contact of the auxiliary relay.
Operation:
Wireless sensors programming: With the board in Disarmed mode.
Press the 'Learn' key briefly, 'Status Prog' LED flashes quickly. Trigger the
wireless sensor.
Programming the remote controls: With the board in Disarmed mode.
Press 'Prog' key briefly, 'Status Prog' LED flashes quickly. Press a button
on the remote.
Product description:
Panic Trigger: Press any key on a remote control registered and hold for
3s or more.
Reset to Factory Default: Press the 'Learn' key and the keep it pressed
for 15s until the 'Status Prog' led turns on. All remote controls and
sensors will be erased and settings will return to factory defaults. (WiFi
connection setting is not affected).
Trigger: When there is a sensor violation or panic trigger, the board will
activate the siren for the programmed time (default 5 min), the STATUS
led flashes fast indicating the trigger until the board is disarmed or
rearmed.
Auxiliary Relay: The auxiliary relay provides a dry contact output for
trigger loads such as high-powered lamps, sirens, or provide status to
other equipment. Its default operation is to trigger along with the siren
output and can be customized in the app as to triggering time and mode.
The possible trigger modes are: Trigger with the control panel disarmed,
with the board armed, with the internal arming and with the trigger.
Sensor inputs: (Z1, Z2, Z3, Z4). One or more wired sensors can be
connected between terminals Z(1-4) and GND. It will be considered
violated if the connection is interrupted.
Jumpers Z(1-4): If closed, deactivate the zone corresponding Z(1-4).
Unused zones must be disabled.
Siren Output: The output is suitable for connecting one or more sirens
with total consumption of up to 1A. If this output goes into a short circuit
or presents a very high consumption due to a defect or an attempt at
sabotage, the “Siren Sensor” will be violated and the board will be
triggered. In this situation, it is ideal to have a second siren installed with
the PGM relay in the “Start with siren” mode.
Application:
Search the store for the 'PPA ON' app.
Create the account in the app.
Add a device.-> Alarm (Wi-Fi)
Keep the cell phone close to the module at the installation site. Check
that the signal level of the mobile Wi-Fi network is good.
Press the PROG button for 5s.
Follow the onscreen instructions.
WARNING:
Do not use the equipment
without referring to this
manual rst.
P30394 - 10/2022
Rev. 1
MANUAL
C36 SMART
ALARM
Historic:
Displays the history of the latest
alarm events, like arming,
disarming, shooting, etc..
Accessories:
Screen for registration and
consultation of accessories
(wired and wireless sensors and
remote controls).
PPA
Restart device first
If the Wifi Led (Blue) is flashing quickly,
skip the reset step.
1 On
2 Press the PROG button for 5 seconds
3 Make sure the Wifi Led (Blue) is flashing
quickly
Confirm that the Wifi Led (Blue)
is flashing quickly
Select a 2.4GHz Wi-Fi network
and enter the password.
If Wi-fi is 5GHz, set it to 2.4GHz before
proceeding. Common method of
router configuration.
Add device
Make sure the device is turned on
Accessories Accessories
Wireless Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 1?
Unknown 2?
Unknown 3?
Sensor Remote Control Sensor Remote Control
Wired Sensor Wired Sensor
Standard Control
Cancel
Cancel
Cancel
EZ mode
Restart devices
Next
Password
Next
Analyze
the devices
Register the
device on
the Cloud
Start
the device
Accessory Types:
Wireless Sensor: Sensors and remote controls with fixed code for panic
triggering. The board allows up to 32 devices of this type.
Remote Control: Remote Controls with Rolling Code Compatible with
PPA. (Ex.: ZAP4 and Slim models). Up to 32 registered remotes are
allowed.
Wired Sensor: Inputs for wired switchboard sensors (Z1,Z2,Z3 and Z4)
and siren sensor. When deleted, these devices return to the factory
default settings.
Zone Type:
Immediate: Default zone type, triggers the siren and sends notification
if the switch is armed.
Internal: Special zone for motion sensors and interior doors, which do
not trigger when the alarm is in 'Internal Arm' mode. Ideal for when the
alarm is armed with residents within the protected perimeter.
24 Hours: Zone that triggers the siren and notification at all times, even
with the alarm in 'Disarmed' mode, ideal for use with panic devices and
perimeter sensors such as electric fence alarm outputs.
Delayed: Zone that ignores triggers within the tolerance time for input
and/or output programmed into the system.
Follower: This zone type behaves like an Immediate zone normally,
however, it becomes a Delayed zone if a Delayed type zone is in time
count.
Zone Attribute:
None: Standard operation.
Smart: With this attribute type there must be 2 openings in the zone in
less than 1 minute or an opening lasting longer than 1 minute to be
considered a violation. It is generally used to prevent false triggering on
some types of wired sensors. Has no effect on wireless sensors.
Silent: When triggering it does not trigger the siren, but sends the
notification to the application normally.
Not Self Bypassing: The zone does not obey the autobypass rule after 4
shots.
Add
Tipo: Movimiento
Zona: Normal
Tipo: Movimiento
Zona: Normal
Status: Normal
Status: Normal
Desconocido 2?
Desconocido 3?
Delete/Edit name
Accessories
Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 2?
Unknown 3?
Sensor Remote Control
Wired Sensor
Slide left
Settings:
Arm/Disarm Sound: Activates the Arm or Disarm notification function
disarm the board by the siren output. It emits two beeps to indicate
board disarming and one beep to indicate disarming. The PGM output
does not trigger in this case even if it is in the “Sir with Siren” mode.
PGM Output Mode: Selects the relay triggering condition PGM.
Possible conditions: Trigger with siren, Trigger in Arming mode,
Triggering in Internal Arming mode or Triggering in Disarmed mode.
PGM output: (Enabled / Disabled) Indicates whether the siren must be
activated in case of a trip.
PGM time: Time in minutes for activating the PGM output. After the
configured time, the output is deactivated. A time equal to zero indicates
triggering with hold (infinite as long as the triggering condition remains).
Siren Trigger Time: Time in minutes for activating the siren. After the
configured time, the siren is deactivated.
Siren Output: (Enabled / Disabled) Indicates whether the Siren must be
activated in the event of a trip.
Entry Delay: Tolerance time for triggering 'Delayed' type zones after
their violation. It is commonly used to allow the user to enter within the
perimeter and have a short period of time to disarm the switch without
firing it.
Exit Time: Tolerance time for triggering zones of the type after the
switch is placed in 'Arm' or 'Internal Arm' mode. Violations in sensors in
these zones within the programmed time do not trigger the switch. It is
used to allow the user to arm the switch when leaving the secured
perimeter.
Made by:
Motoppar Indústria e Comércio de Automatizadores Ltda
Av. Dr. Labieno da Costa Machado, 3526 - Distrito Industrial
Garça - SP - CEP 17406-200 - Brasil
CNPJ: 52.605.821/0001-55
www.ppa.com.br | +55 14 3407 1000
GENERAL TERMS AND CONDITIONS OF WARRANTY
MOTOPPAR, Industry and Commerce of Automatic Gate Operators
Ltd., registered with the CNPJ (National Registry of Legal Entities)
under Number 52.605.821/0001-55, located at 3526 Dr. Labieno da
Costa Machado Avenue, Industrial District, Garça – SP – Brazil, Zip
Code 17400-000, manufacturer of PPA Products, hereby
guarantees this product against design, manufacturing or assembly
defects and/or supportively as a result of material quality flaws that
could make its intended use improper or inadequate, within a legal
period of ninety days from time of acquisition, provided that the
installation instructions described in the instruction manual are
observed.
Due to the credibility and trust placed on PPA products, we will add
275 more days to the period mentioned above, reaching a warranty
period of one year, likewise counted from the time of acquisition
proven by consumer through proof of purchase (Customer Receipt).
In case of defect, within the warranty period, PPA responsibilities are
restricted to the repair or substitution of the product manufactured by
the company, under the following conditions:
1. Repair and readjustment of equipment may only be carried
out by PPA Technical Assistance, which is qualified to open,
remove, and substitute parts or components, as well as repair
defects covered by this warranty; thus, failure on observing
this guideline and the verified use of any non-original parts will
cause the resignation of this warranty on the part of the user;
2. The warranty will not extend to accessories such as cables,
screw kit, fixing brackets, power supplies etc.;
3. Expenses for packaging, transportation and product
reinstallation will be sole responsibility of the consumer;
4. The equipment must be sent directly to the Company
responsible for the sale (manufacturer's representative),
through the address contained in the purchase invoice,
properly packed, thus avoiding loss of the warranty;
5. Within the additional period of 275 days, visits and
transportation in places where authorized technical
assistance is not available will be charged. The cost of
transportation of the product and/or technician will be sole
responsibility of the consumer and
6. The substitution or repair of the product does not prolong the
warranty time.
This warranty will be terminated if the product:
1. Is damaged by natural agents, such as atmospheric
discharges, floods, wildfires, landslides etc.;
2. Is installed in an improper electric power supply or if it is not
according to any of the installation instructions displayed on
the manual;
3. Shows defects caused by droppings, collisions or any other
physical accident;
4. Shows signs of product violation or attempted repair by
unauthorized personnel;
5. Is not used for its intended purpose;
6. Is not used under normal conditions;
7. Is damaged by accessories or equipment connected to it.
Recommendation:
We recommend that both the installation and the maintenance of the
operator to be performed by an authorized PPA technical service. If
the product fails or has an improper operation, seek an Authorized
Technical Service to fix it..

C36 Smart Alarm
Self-monitored alarm board by Android and IOS app with sending
notification in real time, automation and integration with the PPA On line
through the internet via a Wi-Fi connection. Fast and simple registration,
intuitive operation.
Main features:
- Equipped with switched power supply;
- Siren output;
- 12V 7Ah battery charger;
- 1 configurable auxiliary output;
- 4 wired zones;
- Up to 32 wireless zones;
- Up to 32 remote controls;
- Internal, intelligent, timed and 24h zones;
- Internal arming by control key;
- Led (armed and disarmed status);
- Programmable siren time;
- Programmable exit time;
- Programmable entry time;
- Configurable arm/disarm beep;
- Shutdown function on sensors and zones (ignores after 4 shots);
- Monitors battery and power failure;
- Protection against battery short.
Technical features:
Power: 90-240Vac;
Battery: Lead acid 12V 7Ah;
Wi-Fi communication: 802.11 b/g/n 2.4GHz standard;
Wireless Sensors: Open Standard, Fixed Code Compatible with HT6P20;
Remote controls: PPA rolling code, anti-cloning;
Consumption: 300 mA (max);
Dimensions: 230x240x100mm (HxWxD);
Weight: 690g.
Leds:
POWER: Power indicator on source input
STATUS PROG: Reception indicator from a wireless remote control or
sensor
PROG WIFI: WiFi connection status indicator.
Off = Initializing / Offline
Fast flashing = Smart registration mode.
Slow flashing = AP registration mode.
Flashing 1 time = Searching for Wi-Fi signal.
Flashing 2 times = Searching cloud server.
On = Connected to Wi-Fi and cloud.
STATUS: Armed board indicator (On) Disarmed (Off) Shooting (Flashing)
Keys:
PROG: Learning remote controls / Wi-fi connection setup, follow the
app instructions.
APRENDER: Learn wireless sensors / Reset to factory default.
Connections:
CN2: Switched source input of the board.
12V / GND: Power output for sensors.
Z1: Zone 1 wired sensor input. Can be disabled by closing jumper Z1.
Z2: Zone 2 wired sensor input. Can be disabled by closing jumper Z2
Z3: Zone 3 wired sensor input. Can be disabled by closing jumper Z3
Z4: Zone 4 wired sensor input. Can be disabled by closing jumper Z4
SIRENE / GND : Connection to siren.
NA: Auxiliary relay normally open contact.
CO: Auxiliary relay common contact.
NF: normally closed contact of the auxiliary relay.
Operation:
Wireless sensors programming: With the board in Disarmed mode.
Press the 'Learn' key briefly, 'Status Prog' LED flashes quickly. Trigger the
wireless sensor.
Programming the remote controls: With the board in Disarmed mode.
Press 'Prog' key briefly, 'Status Prog' LED flashes quickly. Press a button
on the remote.
Product description:
Panic Trigger: Press any key on a remote control registered and hold for
3s or more.
Reset to Factory Default: Press the 'Learn' key and the keep it pressed
for 15s until the 'Status Prog' led turns on. All remote controls and
sensors will be erased and settings will return to factory defaults. (WiFi
connection setting is not affected).
Trigger: When there is a sensor violation or panic trigger, the board will
activate the siren for the programmed time (default 5 min), the STATUS
led flashes fast indicating the trigger until the board is disarmed or
rearmed.
Auxiliary Relay: The auxiliary relay provides a dry contact output for
trigger loads such as high-powered lamps, sirens, or provide status to
other equipment. Its default operation is to trigger along with the siren
output and can be customized in the app as to triggering time and mode.
The possible trigger modes are: Trigger with the control panel disarmed,
with the board armed, with the internal arming and with the trigger.
Sensor inputs: (Z1, Z2, Z3, Z4). One or more wired sensors can be
connected between terminals Z(1-4) and GND. It will be considered
violated if the connection is interrupted.
Jumpers Z(1-4): If closed, deactivate the zone corresponding Z(1-4).
Unused zones must be disabled.
Siren Output: The output is suitable for connecting one or more sirens
with total consumption of up to 1A. If this output goes into a short circuit
or presents a very high consumption due to a defect or an attempt at
sabotage, the “Siren Sensor” will be violated and the board will be
triggered. In this situation, it is ideal to have a second siren installed with
the PGM relay in the “Start with siren” mode.
Application:
Search the store for the 'PPA ON' app.
Create the account in the app.
Add a device.-> Alarm (Wi-Fi)
Keep the cell phone close to the module at the installation site. Check
that the signal level of the mobile Wi-Fi network is good.
Press the PROG button for 5s.
Follow the onscreen instructions.
WARNING:
Do not use the equipment
without referring to this
manual rst.
P30394 - 10/2022
Rev. 1
MANUAL
C36 SMART
ALARM
Historic:
Displays the history of the latest
alarm events, like arming,
disarming, shooting, etc..
Accessories:
Screen for registration and
consultation of accessories
(wired and wireless sensors and
remote controls).
PPA
Restart device first
If the Wifi Led (Blue) is flashing quickly,
skip the reset step.
1 On
2 Press the PROG button for 5 seconds
3 Make sure the Wifi Led (Blue) is flashing
quickly
Confirm that the Wifi Led (Blue)
is flashing quickly
Select a 2.4GHz Wi-Fi network
and enter the password.
If Wi-fi is 5GHz, set it to 2.4GHz before
proceeding. Common method of
router configuration.
Add device
Make sure the device is turned on
Accessories Accessories
Wireless Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 1?
Unknown 2?
Unknown 3?
Sensor Remote Control Sensor Remote Control
Wired Sensor Wired Sensor
Standard Control
Cancel
Cancel
Cancel
EZ mode
Restart devices
Next
Password
Next
Analyze
the devices
Register the
device on
the Cloud
Start
the device
Accessory Types:
Wireless Sensor: Sensors and remote controls with fixed code for panic
triggering. The board allows up to 32 devices of this type.
Remote Control: Remote Controls with Rolling Code Compatible with
PPA. (Ex.: ZAP4 and Slim models). Up to 32 registered remotes are
allowed.
Wired Sensor: Inputs for wired switchboard sensors (Z1,Z2,Z3 and Z4)
and siren sensor. When deleted, these devices return to the factory
default settings.
Zone Type:
Immediate: Default zone type, triggers the siren and sends notification
if the switch is armed.
Internal: Special zone for motion sensors and interior doors, which do
not trigger when the alarm is in 'Internal Arm' mode. Ideal for when the
alarm is armed with residents within the protected perimeter.
24 Hours: Zone that triggers the siren and notification at all times, even
with the alarm in 'Disarmed' mode, ideal for use with panic devices and
perimeter sensors such as electric fence alarm outputs.
Delayed: Zone that ignores triggers within the tolerance time for input
and/or output programmed into the system.
Follower: This zone type behaves like an Immediate zone normally,
however, it becomes a Delayed zone if a Delayed type zone is in time
count.
Zone Attribute:
None: Standard operation.
Smart: With this attribute type there must be 2 openings in the zone in
less than 1 minute or an opening lasting longer than 1 minute to be
considered a violation. It is generally used to prevent false triggering on
some types of wired sensors. Has no effect on wireless sensors.
Silent: When triggering it does not trigger the siren, but sends the
notification to the application normally.
Not Self Bypassing: The zone does not obey the autobypass rule after 4
shots.
Add
Tipo: Movimiento
Zona: Normal
Tipo: Movimiento
Zona: Normal
Status: Normal
Status: Normal
Desconocido 2?
Desconocido 3?
Delete/Edit name
Accessories
Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 2?
Unknown 3?
Sensor Remote Control
Wired Sensor
Slide left
Settings:
Arm/Disarm Sound: Activates the Arm or Disarm notification function
disarm the board by the siren output. It emits two beeps to indicate
board disarming and one beep to indicate disarming. The PGM output
does not trigger in this case even if it is in the “Sir with Siren” mode.
PGM Output Mode: Selects the relay triggering condition PGM.
Possible conditions: Trigger with siren, Trigger in Arming mode,
Triggering in Internal Arming mode or Triggering in Disarmed mode.
PGM output: (Enabled / Disabled) Indicates whether the siren must be
activated in case of a trip.
PGM time: Time in minutes for activating the PGM output. After the
configured time, the output is deactivated. A time equal to zero indicates
triggering with hold (infinite as long as the triggering condition remains).
Siren Trigger Time: Time in minutes for activating the siren. After the
configured time, the siren is deactivated.
Siren Output: (Enabled / Disabled) Indicates whether the Siren must be
activated in the event of a trip.
Entry Delay: Tolerance time for triggering 'Delayed' type zones after
their violation. It is commonly used to allow the user to enter within the
perimeter and have a short period of time to disarm the switch without
firing it.
Exit Time: Tolerance time for triggering zones of the type after the
switch is placed in 'Arm' or 'Internal Arm' mode. Violations in sensors in
these zones within the programmed time do not trigger the switch. It is
used to allow the user to arm the switch when leaving the secured
perimeter.
Made by:
Motoppar Indústria e Comércio de Automatizadores Ltda
Av. Dr. Labieno da Costa Machado, 3526 - Distrito Industrial
Garça - SP - CEP 17406-200 - Brasil
CNPJ: 52.605.821/0001-55
www.ppa.com.br | +55 14 3407 1000
GENERAL TERMS AND CONDITIONS OF WARRANTY
MOTOPPAR, Industry and Commerce of Automatic Gate Operators
Ltd., registered with the CNPJ (National Registry of Legal Entities)
under Number 52.605.821/0001-55, located at 3526 Dr. Labieno da
Costa Machado Avenue, Industrial District, Garça – SP – Brazil, Zip
Code 17400-000, manufacturer of PPA Products, hereby
guarantees this product against design, manufacturing or assembly
defects and/or supportively as a result of material quality flaws that
could make its intended use improper or inadequate, within a legal
period of ninety days from time of acquisition, provided that the
installation instructions described in the instruction manual are
observed.
Due to the credibility and trust placed on PPA products, we will add
275 more days to the period mentioned above, reaching a warranty
period of one year, likewise counted from the time of acquisition
proven by consumer through proof of purchase (Customer Receipt).
In case of defect, within the warranty period, PPA responsibilities are
restricted to the repair or substitution of the product manufactured by
the company, under the following conditions:
1. Repair and readjustment of equipment may only be carried
out by PPA Technical Assistance, which is qualified to open,
remove, and substitute parts or components, as well as repair
defects covered by this warranty; thus, failure on observing
this guideline and the verified use of any non-original parts will
cause the resignation of this warranty on the part of the user;
2. The warranty will not extend to accessories such as cables,
screw kit, fixing brackets, power supplies etc.;
3. Expenses for packaging, transportation and product
reinstallation will be sole responsibility of the consumer;
4. The equipment must be sent directly to the Company
responsible for the sale (manufacturer's representative),
through the address contained in the purchase invoice,
properly packed, thus avoiding loss of the warranty;
5. Within the additional period of 275 days, visits and
transportation in places where authorized technical
assistance is not available will be charged. The cost of
transportation of the product and/or technician will be sole
responsibility of the consumer and
6. The substitution or repair of the product does not prolong the
warranty time.
This warranty will be terminated if the product:
1. Is damaged by natural agents, such as atmospheric
discharges, floods, wildfires, landslides etc.;
2. Is installed in an improper electric power supply or if it is not
according to any of the installation instructions displayed on
the manual;
3. Shows defects caused by droppings, collisions or any other
physical accident;
4. Shows signs of product violation or attempted repair by
unauthorized personnel;
5. Is not used for its intended purpose;
6. Is not used under normal conditions;
7. Is damaged by accessories or equipment connected to it.
Recommendation:
We recommend that both the installation and the maintenance of the
operator to be performed by an authorized PPA technical service. If
the product fails or has an improper operation, seek an Authorized
Technical Service to fix it..

C36 Smart Alarm
Self-monitored alarm board by Android and IOS app with sending
notification in real time, automation and integration with the PPA On line
through the internet via a Wi-Fi connection. Fast and simple registration,
intuitive operation.
Main features:
- Equipped with switched power supply;
- Siren output;
- 12V 7Ah battery charger;
- 1 configurable auxiliary output;
- 4 wired zones;
- Up to 32 wireless zones;
- Up to 32 remote controls;
- Internal, intelligent, timed and 24h zones;
- Internal arming by control key;
- Led (armed and disarmed status);
- Programmable siren time;
- Programmable exit time;
- Programmable entry time;
- Configurable arm/disarm beep;
- Shutdown function on sensors and zones (ignores after 4 shots);
- Monitors battery and power failure;
- Protection against battery short.
Technical features:
Power: 90-240Vac;
Battery: Lead acid 12V 7Ah;
Wi-Fi communication: 802.11 b/g/n 2.4GHz standard;
Wireless Sensors: Open Standard, Fixed Code Compatible with HT6P20;
Remote controls: PPA rolling code, anti-cloning;
Consumption: 300 mA (max);
Dimensions: 230x240x100mm (HxWxD);
Weight: 690g.
Leds:
POWER: Power indicator on source input
STATUS PROG: Reception indicator from a wireless remote control or
sensor
PROG WIFI: WiFi connection status indicator.
Off = Initializing / Offline
Fast flashing = Smart registration mode.
Slow flashing = AP registration mode.
Flashing 1 time = Searching for Wi-Fi signal.
Flashing 2 times = Searching cloud server.
On = Connected to Wi-Fi and cloud.
STATUS: Armed board indicator (On) Disarmed (Off) Shooting (Flashing)
Keys:
PROG: Learning remote controls / Wi-fi connection setup, follow the
app instructions.
APRENDER: Learn wireless sensors / Reset to factory default.
Connections:
CN2: Switched source input of the board.
12V / GND: Power output for sensors.
Z1: Zone 1 wired sensor input. Can be disabled by closing jumper Z1.
Z2: Zone 2 wired sensor input. Can be disabled by closing jumper Z2
Z3: Zone 3 wired sensor input. Can be disabled by closing jumper Z3
Z4: Zone 4 wired sensor input. Can be disabled by closing jumper Z4
SIRENE / GND : Connection to siren.
NA: Auxiliary relay normally open contact.
CO: Auxiliary relay common contact.
NF: normally closed contact of the auxiliary relay.
Operation:
Wireless sensors programming: With the board in Disarmed mode.
Press the 'Learn' key briefly, 'Status Prog' LED flashes quickly. Trigger the
wireless sensor.
Programming the remote controls: With the board in Disarmed mode.
Press 'Prog' key briefly, 'Status Prog' LED flashes quickly. Press a button
on the remote.
Product description:
Panic Trigger: Press any key on a remote control registered and hold for
3s or more.
Reset to Factory Default: Press the 'Learn' key and the keep it pressed
for 15s until the 'Status Prog' led turns on. All remote controls and
sensors will be erased and settings will return to factory defaults. (WiFi
connection setting is not affected).
Trigger: When there is a sensor violation or panic trigger, the board will
activate the siren for the programmed time (default 5 min), the STATUS
led flashes fast indicating the trigger until the board is disarmed or
rearmed.
Auxiliary Relay: The auxiliary relay provides a dry contact output for
trigger loads such as high-powered lamps, sirens, or provide status to
other equipment. Its default operation is to trigger along with the siren
output and can be customized in the app as to triggering time and mode.
The possible trigger modes are: Trigger with the control panel disarmed,
with the board armed, with the internal arming and with the trigger.
Sensor inputs: (Z1, Z2, Z3, Z4). One or more wired sensors can be
connected between terminals Z(1-4) and GND. It will be considered
violated if the connection is interrupted.
Jumpers Z(1-4): If closed, deactivate the zone corresponding Z(1-4).
Unused zones must be disabled.
Siren Output: The output is suitable for connecting one or more sirens
with total consumption of up to 1A. If this output goes into a short circuit
or presents a very high consumption due to a defect or an attempt at
sabotage, the “Siren Sensor” will be violated and the board will be
triggered. In this situation, it is ideal to have a second siren installed with
the PGM relay in the “Start with siren” mode.
Application:
Search the store for the 'PPA ON' app.
Create the account in the app.
Add a device.-> Alarm (Wi-Fi)
Keep the cell phone close to the module at the installation site. Check
that the signal level of the mobile Wi-Fi network is good.
Press the PROG button for 5s.
Follow the onscreen instructions.
WARNING:
Do not use the equipment
without referring to this
manual rst.
P30394 - 10/2022
Rev. 1
MANUAL
C36 SMART
ALARM
Historic:
Displays the history of the latest
alarm events, like arming,
disarming, shooting, etc..
Accessories:
Screen for registration and
consultation of accessories
(wired and wireless sensors and
remote controls).
PPA
Restart device first
If the Wifi Led (Blue) is flashing quickly,
skip the reset step.
1 On
2 Press the PROG button for 5 seconds
3 Make sure the Wifi Led (Blue) is flashing
quickly
Confirm that the Wifi Led (Blue)
is flashing quickly
Select a 2.4GHz Wi-Fi network
and enter the password.
If Wi-fi is 5GHz, set it to 2.4GHz before
proceeding. Common method of
router configuration.
Add device
Make sure the device is turned on
Accessories Accessories
Wireless Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 1?
Unknown 2?
Unknown 3?
Sensor Remote Control Sensor Remote Control
Wired Sensor Wired Sensor
Standard Control
Cancel
Cancel
Cancel
EZ mode
Restart devices
Next
Password
Next
Analyze
the devices
Register the
device on
the Cloud
Start
the device
Accessory Types:
Wireless Sensor: Sensors and remote controls with fixed code for panic
triggering. The board allows up to 32 devices of this type.
Remote Control: Remote Controls with Rolling Code Compatible with
PPA. (Ex.: ZAP4 and Slim models). Up to 32 registered remotes are
allowed.
Wired Sensor: Inputs for wired switchboard sensors (Z1,Z2,Z3 and Z4)
and siren sensor. When deleted, these devices return to the factory
default settings.
Zone Type:
Immediate: Default zone type, triggers the siren and sends notification
if the switch is armed.
Internal: Special zone for motion sensors and interior doors, which do
not trigger when the alarm is in 'Internal Arm' mode. Ideal for when the
alarm is armed with residents within the protected perimeter.
24 Hours: Zone that triggers the siren and notification at all times, even
with the alarm in 'Disarmed' mode, ideal for use with panic devices and
perimeter sensors such as electric fence alarm outputs.
Delayed: Zone that ignores triggers within the tolerance time for input
and/or output programmed into the system.
Follower: This zone type behaves like an Immediate zone normally,
however, it becomes a Delayed zone if a Delayed type zone is in time
count.
Zone Attribute:
None: Standard operation.
Smart: With this attribute type there must be 2 openings in the zone in
less than 1 minute or an opening lasting longer than 1 minute to be
considered a violation. It is generally used to prevent false triggering on
some types of wired sensors. Has no effect on wireless sensors.
Silent: When triggering it does not trigger the siren, but sends the
notification to the application normally.
Not Self Bypassing: The zone does not obey the autobypass rule after 4
shots.
Add
Tipo: Movimiento
Zona: Normal
Tipo: Movimiento
Zona: Normal
Status: Normal
Status: Normal
Desconocido 2?
Desconocido 3?
Delete/Edit name
Accessories
Wireless
Wireless Sensor 0
Type: Contact
Zone: Normal
Type: Movement
Zone: Internal
Type: Movement
Zone: Timed
Type: Movement
Zone: Normal
Type: Movement
Zone: Normal
Type: Panic
Zone: 24h
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Status: Normal
Wireless Sensor 1
Wireless Sensor 2
Panic
Unknown 2?
Unknown 3?
Sensor Remote Control
Wired Sensor
Slide left
Settings:
Arm/Disarm Sound: Activates the Arm or Disarm notification function
disarm the board by the siren output. It emits two beeps to indicate
board disarming and one beep to indicate disarming. The PGM output
does not trigger in this case even if it is in the “Sir with Siren” mode.
PGM Output Mode: Selects the relay triggering condition PGM.
Possible conditions: Trigger with siren, Trigger in Arming mode,
Triggering in Internal Arming mode or Triggering in Disarmed mode.
PGM output: (Enabled / Disabled) Indicates whether the siren must be
activated in case of a trip.
PGM time: Time in minutes for activating the PGM output. After the
configured time, the output is deactivated. A time equal to zero indicates
triggering with hold (infinite as long as the triggering condition remains).
Siren Trigger Time: Time in minutes for activating the siren. After the
configured time, the siren is deactivated.
Siren Output: (Enabled / Disabled) Indicates whether the Siren must be
activated in the event of a trip.
Entry Delay: Tolerance time for triggering 'Delayed' type zones after
their violation. It is commonly used to allow the user to enter within the
perimeter and have a short period of time to disarm the switch without
firing it.
Exit Time: Tolerance time for triggering zones of the type after the
switch is placed in 'Arm' or 'Internal Arm' mode. Violations in sensors in
these zones within the programmed time do not trigger the switch. It is
used to allow the user to arm the switch when leaving the secured
perimeter.
Made by:
Motoppar Indústria e Comércio de Automatizadores Ltda
Av. Dr. Labieno da Costa Machado, 3526 - Distrito Industrial
Garça - SP - CEP 17406-200 - Brasil
CNPJ: 52.605.821/0001-55
www.ppa.com.br | +55 14 3407 1000
GENERAL TERMS AND CONDITIONS OF WARRANTY
MOTOPPAR, Industry and Commerce of Automatic Gate Operators
Ltd., registered with the CNPJ (National Registry of Legal Entities)
under Number 52.605.821/0001-55, located at 3526 Dr. Labieno da
Costa Machado Avenue, Industrial District, Garça – SP – Brazil, Zip
Code 17400-000, manufacturer of PPA Products, hereby
guarantees this product against design, manufacturing or assembly
defects and/or supportively as a result of material quality flaws that
could make its intended use improper or inadequate, within a legal
period of ninety days from time of acquisition, provided that the
installation instructions described in the instruction manual are
observed.
Due to the credibility and trust placed on PPA products, we will add
275 more days to the period mentioned above, reaching a warranty
period of one year, likewise counted from the time of acquisition
proven by consumer through proof of purchase (Customer Receipt).
In case of defect, within the warranty period, PPA responsibilities are
restricted to the repair or substitution of the product manufactured by
the company, under the following conditions:
1. Repair and readjustment of equipment may only be carried
out by PPA Technical Assistance, which is qualified to open,
remove, and substitute parts or components, as well as repair
defects covered by this warranty; thus, failure on observing
this guideline and the verified use of any non-original parts will
cause the resignation of this warranty on the part of the user;
2. The warranty will not extend to accessories such as cables,
screw kit, fixing brackets, power supplies etc.;
3. Expenses for packaging, transportation and product
reinstallation will be sole responsibility of the consumer;
4. The equipment must be sent directly to the Company
responsible for the sale (manufacturer's representative),
through the address contained in the purchase invoice,
properly packed, thus avoiding loss of the warranty;
5. Within the additional period of 275 days, visits and
transportation in places where authorized technical
assistance is not available will be charged. The cost of
transportation of the product and/or technician will be sole
responsibility of the consumer and
6. The substitution or repair of the product does not prolong the
warranty time.
This warranty will be terminated if the product:
1. Is damaged by natural agents, such as atmospheric
discharges, floods, wildfires, landslides etc.;
2. Is installed in an improper electric power supply or if it is not
according to any of the installation instructions displayed on
the manual;
3. Shows defects caused by droppings, collisions or any other
physical accident;
4. Shows signs of product violation or attempted repair by
unauthorized personnel;
5. Is not used for its intended purpose;
6. Is not used under normal conditions;
7. Is damaged by accessories or equipment connected to it.
Recommendation:
We recommend that both the installation and the maintenance of the
operator to be performed by an authorized PPA technical service. If
the product fails or has an improper operation, seek an Authorized
Technical Service to fix it..
Table of contents
Other PPA Security System manuals
Popular Security System manuals by other brands

Siemens
Siemens milltronics MFA 4P instruction manual

Tyco
Tyco DSC neo HS2016 user guide

Pfannenberg
Pfannenberg PY X-S-05 Operating and installation instruction

Swann
Swann RL-0507A operating instructions

LEAK DEFENSE
LEAK DEFENSE LDS-3-API manual

Ei Electronics
Ei Electronics RadioLINK Base Smoke & Heat Alarms Ei168 Technical specifications