PR electronics 4511 User manual

PERFORMANCE
MADE
SMARTER
Product manual
4511
Modbus communication enabler
TEMPERATURE | I.S. INTERFACES | COMMUNICATION INTERFACES | MULTIFUNCTIONAL | ISOLATION | DISPLAY
No. 4511V103-UK
From serial no.: 221207001

6 Product Pillars
to meet your every need
With our innovative, patented technologies, we make signal conditioning smarter and simpler. Our portfolio is composed of six
product areas, where we offer a wide range of analog and digital devices covering over a thousand applications in industrial
and factory automation. All our products comply with or surpass the highest industry standards, ensuring reliability in even
the harshest of environments and have a 5-year warranty for greater peace of mind.
Individually outstanding, unrivalled in combination
Our range of temperature transmitters and sensors provides the highest level of signal integrity from the
measurement point to your control system. You can convert industrial process temperature signals to analog, bus or
digital communications using a highly reliable point-to-point solution with a fast response time, automatic self-
calibration, sensor error detection, low drift, and top EMC performance in any environment.
Our unique range of single devices covering multiple applications is easily deployable as your site standard. Having
one variant that applies to a broad range of applications can reduce your installation time and training, and greatly
simplify spare parts management at your facilities. Our devices are designed for long-term signal accuracy, low
power consumption, immunity to electrical noise and simple programming.
We provide inexpensive, easy-to-use, future-ready communication interfaces that can access your PR installed base
of products. All the interfaces are detachable, have a built-in display for readout of process values and diagnostics,
and can be configured via push-buttons. Product specific functionality includes communication via Modbus and
Bluetooth and remote access using our PR Process Supervisor (PPS) application, available for iOS and Android.
Our display range is characterized by its flexibility and stability. The devices meet nearly every demand for display
readout of process signals and have universal input and power supply capabilities. They provide a real-time
measurement of your process value no matter the industry and are engineered to provide a user-friendly and reliable
relay of information, even in demanding environments.
We deliver the safest signals by validating our products against the toughest safety standards. Through our
commitment to innovation, we have made pioneering achievements in developing I.S. interfaces with SIL 2 Full
Assessment that are both efficient and cost-effective. Our comprehensive range of analog and digital intrinsically
safe isolation barriers offers multifunctional inputs and outputs, making PR an easy-to-implement site standard.
Our backplanes further simplify large installations and provide seamless integration to standard DCS systems.
Our compact, fast, high-quality 6 mm isolators are based on microprocessor technology to provide exceptional
performance and EMC-immunity for dedicated applications at a very low total cost of ownership. They can be
stacked both vertically and horizontally with no air gap separation between units required.

4511V103-UK 1
Modbus communication enabler
4511
Contents
Warning ................................................................................................ 2
Symbol identification .................................................................................... 2
Safety instructions ...................................................................................... 3
Mounting / demounting of a PR 4500 communication interface............................................. 4
Applications ............................................................................................ 5
Technical characteristics ................................................................................. 5
Mounting / installation / programming .................................................................... 5
Order ................................................................................................... 6
Electrical specifications .................................................................................. 6
4511 installation examples .............................................................................. 7
Modbus basics .......................................................................................... 8
4511 Modbus parameter settings ........................................................................ 9
Display layout........................................................................................... 10
Operating the function keys / display ..................................................................... 11
4511 Modbus settings - routing diagram .................................................................. 13
ATEX / UKEX Installation Drawing ........................................................................ 15
IECEx Installation Drawing ............................................................................... 17
FM Installation Drawing.................................................................................. 19
Document history ....................................................................................... 21

2 4511V103-UK
Warning
This device is designed for connection to hazardous electric voltages. Ignoring this warning can result in
severe personal injury or mechanical damage.
To avoid the risk of electric shock and fire, the safety instructions of this guide must be observed and
the guidelines followed. The specifications must not be exceeded, and the device must only be applied
as described in the following.
Prior to the commissioning of the device, this installation guide must be examined carefully.
Only qualified personnel (technicians) should install this device.
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired.
Warning
Until the device is fixed, do not connect hazardous voltages to the device. The following operations
should only be carried out on a disconnected device and under ESD safe conditions:
General mounting, connection and disconnection of Modbus cable.
Troubleshooting the device.
Warning
Repair of the device must be done by PR electronics A/S only.
Symbol identification
Triangle with an exclamation mark: Read the manual before installation and commissioning of the
device in order to avoid incidents that could lead to personal injury or mechanical damage.
The CE mark proves the compliance of the device with the essential requirements of the EU-directives.
The UKCA mark proves the compliance of the device with the essential requirements of the UK
regulations.
The double insulation symbol shows that the device is protected by double or reinforced insulation.
Ex devices have been approved according to the ATEX directive / UKEX regulations for use in connection
with installations in explosive areas.
GENERAL
CAUTION
HAZARD-
OUS
VOLTAGE

4511V103-UK 3
Safety instructions
Receipt and unpacking
Unpack the device without damaging it and check whether the device type corresponds to the one ordered. The packing
should always follow the device until this has been permanently mounted.
Environment
Avoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, as well as rain and heavy moisture. If
necessary, heating in excess of the stated limits for ambient temperatures should be avoided by way of ventilation.
The device must be installed in pollution degree 2 or better. The device is designed to be safe at least under an altitude up to
2 000 m. The device is designed for indoor use.
Mounting
Only qualified technicians who are familiar with the technical terms, warnings, and instructions in this installation guide and
who are able to follow these should connect the device. Only devices which are undamaged and free of moist and dust may be
installed. The device may be installed and supplied by PR 4590 ConfigMate and PR 4000 / 9000 series devices only.
Should there be any doubt as to the correct handling of the device, please contact your local distributor or, alternatively,
PR electronics A/S
www.prelectronics.com
Cleaning
When disconnected, the device may be cleaned with a cloth moistened with distilled water.
Warranty
PR electronics A/S offers a 5-year warranty on this product.
Liability
To the extent the instructions in this manual are not strictly observed, the customer cannot advance a demand against PR
electronics A/S that would otherwise exist according to the concluded sales agreement.

2
1
3
4
4 4511V103-UK
Mounting / demounting of a PR 4500 communication interface
Communication interfaces in the PR 4500 series are detachable displays that can be mounted on a PR 4590 Configmate or all
system 4000 / 9000 fronts for programming and signal monitoring.
Mounting
1: Insert the tabs of the PR 4500 into the holes at the top of the device.
2: Hinge the PR 4500 down until it snaps into place.
Demounting
3: Push the release button on the bottom of the PR 4500 and hinge the the PR 4500 out and up.
4: With the PR 4500 hinged up, remove from the holes at the top of the device.

4511V103-UK 5
Modbus communication enabler
4511
• Programming display for system 4000 and 9000 devices as well as selected
system 3000 devices
• Modbus RTU protocol interface over RS-485
• Monitor process value from the built-in display
• High 2.5 kV isolation to host unit
• Shielded RJ45 Modbus connector on top
Applications
• The 4511 detachable display adds Modbus RTU RS-485 serial communications to all current and future 4000 / 9000 units.
• The unit converts a wide array of sensors and analog device signals measured by the system 4000, like uni- and bipolar
mA and voltage signals, potentiometer, lin. R, RTD and TC, to a Modbus communication line signal.
• When mounted on a system 9000 device any signal coming from or going to I.S. classified area, like AI, AO, DI and DO
signals, can be converted to a Modbus network.
• All individual unit operating parameters can easily and quickly be configured by using the Modbus communication or by
using the front display menu.
• The easily readable 4511 display can be used to read the process signal, simulate the output signal, indicate sensor errors
and internal module errors.
• The 4511 can be moved from one device to another. The individual system 3000 / 4000 / 9000 device configuration of a
transmitter can be saved and downloaded to subsequent transmitters.
Technical characteristics
• 4511 has full functionality for unit programming, process signal monitoring and diagnostics handling.
• Modbus RTU protocol is supported using a serial RS-485 communication wiring.
• Multidrop half-duplex connection via shielded RJ45 connector.
• High, safe galvanic isolation of 2.5 kVAC between the serial wiring and the connected system 4000 / 9000 units.
• Modbus parameters such as address, baud rate, stop bit(s), and parity bit are configured from the 4511 display, which also
stores parameters.
Mounting / installation / programming
• Mounting in Zone 2 / Div 2.
• All configuration data from a PR 3000 / 4000 / 9000 device can be transferred to a PC using the PR 4590.
• Programmed parameters can be protected by a user-defined password.
• When mounted on devices that are installed upside down, a menu item allows the display on the 4511 to be rotated 180
and the up/down buttons to switch function.

6 4511V103-UK
Order
Type Description
4511
4590
Communication enabler
Configmate interface
Electrical specifications
Environmental conditions:
Specifications range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20°C to +60°C
Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -20°C to +85°C
Humidity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . < 95% RH (non-cond.)
Protection degree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP20
Installation in pollution degree 2 / overvoltage category II.
Mechanical specifications:
Dimensions (HxWxD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73.2 x 23.3 x 26.5 mm
Dimensions (HxWxD) w/ 4000/9000 unit . . . . . . . . . . . . . . . . . . . . . 109 x 23.5 x 131 mm
Weight approx. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 g
Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RJ45 - shielded
Common specifications:
Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 0.15 W
Isolation voltage - test / working . . . . . . . . . . . . . . . . . . . . . . . . . . 2.5 kVAC / 250 VAC reinforced isolation
Extended EMC immunity:
NAMUR NE 21, A criterion, burst . . . . . . . . . . . . . . . . . . . . . . . . . No loss of communication
Signal / noise ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 60 dB
Update rate / response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . > 50 Hz / < 20 ms
Signal type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RS-485 half duplex
Serial protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modbus RTU
Modbus mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RTU - slave
Devices on an RS485 line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Up to 32 (without a repeater)
Data rates, baud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400, 4800, 9600, 19200,
38400, 57600, 115200
Automatic baudrate detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . Yes - can be configured ON or OFF
Parity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Even, Odd, None
Stop bit(s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 or 2
Digital adressing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1...247
Response delay. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0...1000 ms
Observed authority requirements:
EMC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2014/30/EU & UK SI 2016/1091
ATEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2014/34/EU & UK SI 2016/1107
LVD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2014/34/EU & UK SI 2010/1101
RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2011/65/EU & UK SI 2012/3032
Approvals:
DNV, Ships & Oshore. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TAA00000JD
c UL us, UL 61010-1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . E314307
EAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TR-CU 020/2011
Ex:
ATEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEKRA 13ATEX0098 X
IECEx . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEK 13.0026 X
FM, US . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FM22US0014X
FM, CA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FM22CA0009X
UKCA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DEKRA 21UKEX0167X

4000
/
9000
4000
/
9000
4000
/
9000
IP54
4000
/
9000
4000
/
9000
4000
/
9000
4511 45114511
4511 45114511
T
T
4511V103-UK 7
4511 installation examples
Modbus RTU
Zone 2 / Cl. 1, Div. 2, gr. A-DSafe Area Gateway
Modbus RTU
PLC/DCS
HMI/PC
PLC/DCS
HMI/PC
Modbus RTU

8 4511V103-UK
Modbus basics
Modbus is a “master-slave” system..., where the “master” communicates with one or multiple “slaves”.
The master typically is a PLC (Programmable Logic Controller), DCS (Distributed Control System), HMI (Human Machine
Interface), RTU (Remote Terminal Unit) or PC.
The three most common Modbus versions used are: MODBUS ASCII, MODBUS RTU and MODBUS/TCP.
In Modbus RTU, data is coded in binary, and requires only one communication byte per data byte. This is ideal for use over
multi-drop RS485 networks, at speeds up to 115,200 bps.
The most common speeds are 9,600 bps and 19,200 bps.
Modbus RTU is the most widely used industrial protocol and is supported by the 4511.
Modbus RTU:
To communicate with a slave device, the master sends a message containing:
Device Address - Function Code - Data - Error Check
The Device Address is a number from 0 to 247.
Messages sent to address 0 (broadcast messages) will be accepted by all slaves, but numbers 1-247 are addresses of specific
devices.
With the exception of broadcast messages, a slave device always responds to a Modbus message so the master knows the
message was received.
4511 Supported Modbus Function Codes:
Command Function code
Read Holding Registers* 03
Read Input Registers* 04
Write Single Register 06
Diagnostics 08
Write Multiple Registers 16
*Holding Registers and Input Registers contain identical data in PR 4511.
The Function Code defines the command that the slave device is to execute, such as read data, accept data, report status.
Some function codes have subfunction codes.
The Data defines addresses in the device’s memory map for read functions, contains data values to be written into the
device’s memory, or contains other information needed to carry out the function requested.
The Error Check is a 16-bit numeric value representing the Cyclic Redundancy Check (CRC).
Maximum number of registers which can be read or written at once:
For a read command, the limit is 8 registers at a baud rate up to 38,400 bps, 16 registers @ 57,800 bps and 32 registers @
115,200 bps.
For a write command, the limit is 123 registers at baud rates up to 115,200 bps.
RJ45 Modbus Connector
Pin 5: RS485 A line
Pin 4: RS485 B line
Pin 8: RS485 GND and shield

4511V103-UK 9
4511 Modbus parameter settings
Automatic Baudrate Detection:
Can be configured YES or NO
Supported baudrates:
2400, 4800, 9600, 19.2k, 38.4k, 57.6k, 115.2k bps
Parity Mode:
Even, Odd or None parity
Stop Bits:
1or 2 stop bits
Response delay:
0...1000 ms (0 ms = default)
Modbus slave addressing range:
1 - 247 (247 = default address)
Modbus Parameter Storage:
Saved in non-volatile memory in the 4511 device
(Factory Default Values are marked in bold)
Modbus RTU segment line termination:
A 120 Ohm resistor should be installed on both ends of a RS485 Modbus RTU segment loop to prevent signal echoes from
corrupting data on the line.

10 4511V103-UK
Display layout
By default, the PR 4511 enters monitor mode for process surveillance. With the front keys, the 4511 can enter programming
or simulation mode.
Layout for 3000/4000 and 9000 series products (in monitor mode)
PR 3000 / 4000
Line 1 shows the scaled process value.
Line 2 shows the selected engineering unit.
Line 3 shows analog output value or TAG no.
Line 4 shows status for relay, communication and e.g. signal
trending.
PR 9000
Line 1 shows status for input channel/-s.
Line 2 and 3 show analog output value / digital output status /
analog input value / TAG no. where appliable or alternating
values.
Line 4 shows status for relay, communication and e.g. signal
trending.

4511V103-UK 11
Operating the function keys / display
In general
When using the PR 4511 for configuration of a PR 4000 or PR 9000 device, you will be guided through all parameters and can
choose the settings which fit the application. For each menu there is a scrolling help text which is automatically shown in line
3 on the display.
Configuration is carried out by use of the 3 function keys:
1will increase the numerical value or choose the next parameter
2will decrease the numerical value or choose the previous parameter
3will save the chosen value and proceed to the next menu
When configuration is completed, the display will return to the default state (monitor). Pressing and holding 3will return to
the previous menu or return to the default state without saving the changed values or parameters.
If no key is activated for 1 minute, the display will return to the default state without saving the changed values or
parameters.
For device-specific programming menus, please refer to the user manual for each device, e.g. PR 4116.
4511 display icons explained
PR 3000 / 4000 Relay status (relay energized). Icon with 1 or 2 blinking indicates
delayed relay action (programmable on/off delay).
Arrow up/down indicates process value is trending higher/lower.
Circular indicator confirms display-to-host communication.
PR 9000 Relay status (Relay energized]. Icon with 1 or 2 blinking indicates
delayed relay action (programmable on/off delay).
Arrow up/down indicates process value is trending higher/lower.
Circular indicator confirms display-to-host communication. Steady
dot indicates device is SIL-locked; blinking dot indicates non SIL-
locked device.
Checkmark indicates input OK or ‘!’ for error condition / device
error on channel input.
One or two channels:
ON indicates that the relay / digital output is energized.
OFF = not energized.
The pulse icon indicates input frequency above 1 Hz.
Device faults are displayed in channel 1 status.
Device or sensors fault messages e.g. CA.BR (cable break) are
device-dependent; please consult device manual for a complete
list of applicable error codes.

12 4511V103-UK
4511 functions
The PR 4511 gives access to a number of functions which can be reached by answering “Yes” to the menu point “ADV.SET”
(see “4511 Modbus settings - routing diagram” on page 13).
Modbus setup (MODB): With the Modbus RTU interface you can set Modbus address, parity, stop bit, response delay and baud
rate.
Display orientation (ORIEN): The menu item “ORIEN” allows the user to rotate the display 180 degrees for correct operation
with upside down mounting of the device.

4511 local submenu:
V0R9
"Monitor"
SCROLLING HELPTEXTS:
40.0
0000
(correct)
No
(No)
xxxx
[1]
Set correct password
%
---OK-->
--------->
PASSW.
---OK-->
ADV.SET
---OK-->
XXXX
[2]
Enter advanced setup menu?
10.4mA
[1]
[2]
(Yes)
[x]
[3]
Enter Language setup
^ o
V
Enter Password setup
v ^
v ^
|
v ^
Enter Simulation mode
|
9999
YES
|
Perform Process calibration
|
0000
NO
|
Enter Display setup
|
|
Perform Memory operations
|
|
MEM
(MEM)
Enter Modbus setup
|
|---->
SETUP
-OK-|-->
Enter Rotation setup
|
[3]
|
[4]
Enable modbus communication
|
(DISP)
Disable Modbus communication
|
v ^
|-->
See automatic baudrate detection status
|
MEM
|
[5]
Reset Modbus to default?
|
DISP
(CAL)
[6]
Select Modbus slave address
|
CAL
|-->
[7]
Select parity for Modbus
|
SIM
|
[8]
Select number of stop bits
|
PASS
(SIM)
[9]
Select response delay in ms
|
LANG
|-->
[10]
Enable automatic baudrate detection
|
MODB
|
[11]
Modbus baudrate not detected
|
ORIEN
(PASS)
Searching for Modbus baudrate
|
|-->
Modbus baudrate detected
|
|
[12]
Select baudrate in bps
|
(LANG)
[13]
Rotate device upside down?
| |-->
|
|
| (MODB) YES (OFF)
|--> ------- ------- ------- ------- ------- ------- -------
|--> MOD.EN ---OK--> ------- ------- ------- ------- ------- ------- ------- ------- ------- ------- ---------> "Monitor"
|
[4]
(ON) |
^
^
|
|
NO
(Yes)
|
|
| v ^ |----> MOD.RST ---OK--> ----| |
! ! ! Returns to "Monitor" from any menu, after 1 min with no keypress.
|
ON
|
[5]
(No) |
|
! ! ! Returns to "Monitor" upon succesful Modbus write command.
|
OFF
|
|
247
EVEN
1
20
NO
(Yes)
|
|STATUS
*1) | v ^ |----> ADR PARITY STP.BIT RSP.DLY AUTO.B ---OK--> ------- -------> ----|
||YES [6] [7] [8] [9] [10] (No) | ^
|
|
NO
|
|
| | v ^ v ^ v ^ v ^ v ^ | 19.2k |
|| 247 EVEN 1 1000 YES
|---->
BAUD OK -|
|| | ODD 2 | NO [12]
|
|
1
NONE
0
| (STATUS) v ^
|
|
*1)
2400
|| SEAR 4800
*1)
| |----> ------- ------- ------- ---------> STATUS ---OK--> "Monitor" 9600
Only if automatic baudrate detection is enabled
|
[11]
19.2k
(ORIEN)
NO
38.4k
|--> ROT.DEV ---OK--> "Monitor" ERR 57.6k
[13]
SEAR 115.2k
2400
v ^
4800
YES
9600
NO
19.2k
38.4k
57.6k
115.2k
The gray shaded menus/texts are only shown for guidance, and are not part of
the 4511 specific submenu.
The Modbus submenu is located somewhere in the menu structure of any host
device supporting 4511. The actual place is defined for each particular device.
PR electronics A/S 4511 Local Menu.xlsx FSS 13-10-2014
4511V103-UK 13
4511 Modbus settings - routing diagram
! ! ! Returns to “Monitor” from any menu, after 1 min. with no
keypress.
! ! ! Returns to “Monitor” upon succesful Modbus write command.
* 1) Only if automatic baudrate detection is enabled.
De gråtonede menuer/tekster vises kun som vejledning, og de er
ikke en del af den specifikke undermenu for 4511.
The Modbus submenu is located somewhere in the menu structure
of any host device supporting 4511. The actual place is defined for
each particular device.

14 4511V103-UK
4511 local submenu:
V0R9
"Monitor"
SCROLLING HELPTEXTS:
40.0
0000
(correct)
No
(No)
xxxx
[1]
Set correct password
%
---OK-->
--------->
PASSW.
---OK-->
ADV.SET
---OK-->
XXXX
[2]
Enter advanced setup menu?
10.4mA
[1]
[2]
(Yes)
[x]
[3]
Enter Language setup
^ o
V
Enter Password setup
v ^
v ^
|
v ^
Enter Simulation mode
|
9999
YES
|
Perform Process calibration
|
0000
NO
|
Enter Display setup
|
|
Perform Memory operations
|
|
MEM
(MEM)
Enter Modbus setup
|
|---->
SETUP
-OK-|-->
Enter Rotation setup
|
[3]
|
[4]
Enable modbus communication
|
(DISP)
Disable Modbus communication
|
v ^
|-->
See automatic baudrate detection status
|
MEM
|
[5]
Reset Modbus to default?
|
DISP
(CAL)
[6]
Select Modbus slave address
|
CAL
|-->
[7]
Select parity for Modbus
|
SIM
|
[8]
Select number of stop bits
|
PASS
(SIM)
[9]
Select response delay in ms
|
LANG
|-->
[10]
Enable automatic baudrate detection
|
MODB
|
[11]
Modbus baudrate not detected
|
ORIEN
(PASS)
Searching for Modbus baudrate
|
|-->
Modbus baudrate detected
|
|
[12]
Select baudrate in bps
|
(LANG)
[13]
Rotate device upside down?
| |-->
|
|
| (MODB) YES (OFF)
|--> ------- ------- ------- ------- ------- ------- ------- |--> MOD.EN ---OK--> ------- ------- ------- --
----- ------- ------- ------- ------- ------- ------- --------->
"Monitor"
|
[4]
(ON) |
^
^
|
|
NO
(Yes)
|
|
| v ^ |----> MOD.RST ---OK--> ----|
|
! ! ! Returns to "Monitor" from any menu, after 1 min with no keypress.
|
ON
|
[5]
(No) |
|
! ! ! Returns to "Monitor" upon succesful Modbus write command.
|
OFF
|
|
247
EVEN
1
20
NO
(Yes)
|
|STATUS *1) | v ^ |----> ADR PARITY STP.BIT RSP.DLY
AUTO.B ---OK--> ------- -------> ----|
||
YES [6] [7] [8] [9] [10] (No) | ^
|
|
NO
|
|
| | v ^ v ^ v ^ v ^ v ^ |
19.2k |
||
247 EVEN 1 1000 YES
|---->
BAUD OK -|
||
| ODD 2 | NO [12]
|
|
1
NONE
0
| (STATUS)
v ^
|
|
*1)
2400
||
SEAR 4800
*1) | |----> ------- ------- ------- --------->
STATUS ---OK--> "Monitor" 9600
Only if automatic baudrate detection is enabled
|
[11]
19.2k
(ORIEN)
NO
38.4k
|--> ROT.DEV ---OK-->
"Monitor" ERR 57.6k
[13]
SEAR 115.2k
2400
v ^
4800
YES
9600
NO
19.2k
38.4k
57.6k
115.2k
The gray shaded menus/texts are only shown for guidance, and are not part of
the 4511 specific submenu.
The Modbus submenu is located somewhere in the menu structure of any host
device supporting 4511. The actual place is defined for each particular device.
PR electronics A/S 4511 Local Menu.xlsx FSS 13-10-2014
Default settings:
Baud rate: 19.2 kbps
Parity mode: Even
Stop bit: 1
Address: 247
Reponse delay: 0 ms

4511V103-UK 15
ATEX/UKEX Installation drawing
4500QA01-V1R0
Ex Certificates DEKRA 13ATEX0098 X
DEKRA 21UKEX0167X
Standards: EN IEC 60079-0
EN 60079-7
Marking: II 3G Ex ec IIC T5
Temperature range -20°C ≤ Ta ≤ +60°C
ATEX/UKEX Installation Instructions
For safe installation of the 4500 series of products the following must be
observed.
Unclassified Area
Hazardous Area
II 3G Ex IIC
PR
4000/9000
PR
4000/9000
PR
4000/9000
4511 4511 4511
IP 54
TGateway
PLC /DCS
HMI/PC
Modbus RTU
Unclassified Area
Hazardous Area
II 3G Ex IIC
PR
4000/9000
PR
4000/9000
PR
4000/9000
4510/
4512
IP 54
4510/
4512
4510/
4512
ATEX / UKEX Installation Drawing

16 4511V103-UK
General installation instructions
Year of manufacture can be taken from the first two digits in the serial number.
For safe Ex installation the following must be observed: The device must be installed
by qualified personnel who are familiar with the national and international laws,
directives and standards that apply to this area.
To prevent ignition of the explosive atmospheres do not separate connectors when
energized and an explosive gas mixture is present.
To avoid the risk of explosion due to electrostatic charging of the enclosure, do not
handle the units unless the area is known to be safe, or appropriate safety measures
are taken to avoid electrostatic discharge.
Mounting of PR 4500 communications interface:
1. Insert the tabs of the PR 4500 into the slots at the top of the device.
2. Hinge the PR 4500 down until it snaps into place.
Demounting of the PR 4500 communication interfaces:
3. Push the release button on the bottom of the PR 4500 and hinge the PR 4500
out and up.
4. With the PR 4500 hinged up, remove from the slots at the top of the device.
Specific Conditions of Use
•The equipment shall only be used in an area of not more than pollution degree
2, as defined in EN IEC 60664-1.
•The devices must be installed in a suitable enclosure providing a degree of
protection of at least IP54 according to EN IEC 60079-0, taking into account
the environmental conditions under which the equipment will be used.
•Transient protection shall be provided that is set at a level not exceeding
140% of the peak rated voltage value at the supply terminals to the
equipment.

IECEx Installation drawing 4500QI01-V1R0
Ex Certificates IECEx DEK 13.0026X
Standards: IEC 60079-0
IEC 60079-7
Marking: Ex ec IIC T5 Gc
Temperature range -20°C ≤ Ta ≤ +60°C
IECEx Installation Instructions
For safe installation of the 4500 series of products the following must be
observed.
Unclassified Area
Hazardous Area
PR
4000/9000
PR
4000/9000
PR
4000/9000
4511 4511 4511
IP 54
TGateway
PLC /DCS
HMI/PC
Modbus RTU
Unclassified Area
Hazardous Area
PR
4000/9000
PR
4000/9000
PR
4000/9000
4510/
4512
IP 54
4510/
4512
4510/
4512
IECEx Installation Drawing
4511V103-UK 17

General installation instructions
Year of manufacture can be taken from the first two digits in the serial number.
For safe Ex installation the following must be observed: The device must be installed
by qualified personnel who are familiar with the national and international laws,
directives and standards that apply to this area.
To prevent ignition of the explosive atmospheres do not separate connectors when
energized and an explosive gas mixture is present.
To avoid the risk of explosion due to electrostatic charging of the enclosure, do not
handle the units unless the area is known to be safe, or appropriate safety measures
are taken to avoid electrostatic discharge.
Mounting of PR 4500 communications interface:
1. Insert the tabs of the PR 4500 into the slots at the top of the device.
2. Hinge the PR 4500 down until it snaps into place.
Demounting of the PR 4500 communication interfaces:
3. Push the release button on the bottom of the PR 4500 and hinge the PR 4500
out and up.
4. With the PR 4500 hinged up, remove from the slots at the top of the device.
Specific Conditions of Use
•The equipment shall only be used in an area of not more than pollution degree
2, as defined in EN IEC 60664-1.
•The devices must be installed in a suitable enclosure providing a degree of
protection of at least IP54 according to EN IEC 60079-0, taking into account
the environmental conditions under which the equipment will be used.
•Transient protection shall be provided that is set at a level not exceeding
140% of the peak rated voltage value at the supply terminals to the
equipment.
18 4511V103-UK
Other manuals for 4511
2
Table of contents
Other PR electronics Measuring Instrument manuals

PR electronics
PR electronics 5714 User manual

PR electronics
PR electronics 5202 User manual

PR electronics
PR electronics 5700 Series User manual

PR electronics
PR electronics PRetrans 5115 Series User manual

PR electronics
PR electronics 5714 User manual

PR electronics
PR electronics 5714 User manual

PR electronics
PR electronics PReview 5515 User manual

PR electronics
PR electronics 5514 User manual

PR electronics
PR electronics 5511 User manual

PR electronics
PR electronics 4510 User manual