8/18
ET XX
(User memory,ET01~ET16)
COL1
(Colour 1) X
(Number: 0~14[3])
COL
(Colour 2) X
(Number: 0~14)
COL
(Colour 3) X
(Number: 0~14)
COL
(Colour 4) X
(Number: 0~14)
T*B
Timer value and brightness
value setting
T-S
Current time setting[4] HOUR
MINU
T-ON
Power on time setting[4] HOUR
MINU
T-OF
Power off time setting HOUR
MINU
B-ON
Power on by brightness setting[5] 1-100
B-OF
Power off bybrightness setting 1-100
B-EN
Check brightness 1-101
Note:
[1]. There can only be one main unit set as master at the same single circuit. Please remove DMX single when main
unit function is working.
[2]. When multiple projectors’ work together in synchronous control state, Parameters can be transmitted from the
master projector to the slave projectors in the following conditions, such as DMX channel mode, display setting
status brightness level setting, timer control setting, DMX setting, brightness value setting, timer value setting,
current time value and operation mode (User memory data is included). Please set main unit as master and others
as slave while carrying on transmitting parameters.
[3]. Colour number in user’s memory represents refer to the following table
Number 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14
Colour R G B W RG RB RW GB GW BW RGB RGW RBW GBW RGBW
[4]. When timer control setting (T-C) is set to ON: Power on time is set to t1, Power off time is set to t2, current time is set
to t3.
If t2 >t1, when t1<=t3<t2, the projector is power on, In addition time of the projector is power off.
If t2 <t1, when t2<=t3<t1, the projector is power off, In addition time of the projector is power on.
If t2 =t1, the projector is power on.
[5]. When brightness level control (b-C) is set to ON: Power on by brightness is set to b1, power off by brightness is set
to b2, current brightness is set to b3.
If b2 >b1, when b1<=b3<b2, the projector is power on, in addition brightness of the projector is power off.
If b2 <b1, when b2<=b3<b1, the projector is power off, in addition brightness of the projector is power on.
If b2 =b1, the projector is power on.
[6]. Brightness level control setting and timer control is a logic and or relationship, if one of them to conform the off
condition, the LED lights turn off.