1
Wavelength:635-650nmWavelength:635-650nm
VISIBLE LASER RADIATIONVISIBLE LASER RADIATION
SEMICONDUCTOR LASERSEMICONDUCTOR LASER
AVOD EYE OR SKIN EXPOSUREAVOD EYE OR SKIN EXPOSURE
TO DIRECT OR SCATTERED RADIATIONTO DIRECT OR SCATTERED RADIATION
Wavelength:800-1700nmWavelength:800-1700nm
INVISIBLE LASER RADIATIONINVISIBLE LASER RADIATION
SEMICONDUCTOR LASERSEMICONDUCTOR LASER
AVOD EYE OR SKIN EXPOSUREAVOD EYE OR SKIN EXPOSURE
TO DIRECT OR SCATTERED RADIATIONTO DIRECT OR SCATTERED RADIATION
CLASS I LASER PRODUCTCLASS I LASER PRODUCT
You arecautioned that changes ormodifications not espressly approvedin this document
could void youtauthority to operate this equipment.
To reducethe risk offire or electricshock,do not expose thisapparatus to rainor moisture.
To avoidelectrical shock, do notopen the cabinet. Referservicing to qualified personnel only.
As the laseris harmful to theeyes, do notattempt to disassemble the cabinet.
Precautions for Use
Use batteries
At the same time,can not use differentstyle or different capacitancebatteries. And only charge the rechargeable batteries.
Avoiding condensation problems
As much as possible,avoid sudden temperature changes.Do not attempt touse the drive immediatelyafter moving it froma cold
to a warm location,to raising the roomtemperature suddenly, as condensation may formwith in the drive.If the temperature
changes suddenly while usingthe drive, stop usingit and take outbatteries for at leastan hour.
Storage
When long timeno use,must take out the batteries to avoid destroyingthe device.

Contents
1. Warning and Note
2. Accessories
3. Product presentation
3.1 Description
3.2 Install the battery
3.2 On/off and permanent on
3.3 Backlight function
3.4 Select wavelength
3.5 Modulation wave output
3.6 Wavelength identification
3.7 Battery energy Indicator
3.8 Battery charge
3.9 Maintenance and solution
1
4
3
4
5
6
7
8
9
10
11
12
13
3.10 Detail parameter 14

Check the accessories
Standard Edition
Optional
3
2x AA LR61.5V or rechargeable battery
Packet
Damping Jacket
Host
MT-7801-FCMT-7801-FC
Fiber Optical Light SourceFiber Optical Light Source
Wavelength:1310nm / 1550nmWavelength:1310nm / 1550nm
ID
MOD
PERM Set
>2s OFF
User's Guide
Optical Laser Source
English
MT-7801-FC/MT-7802-FC/MT-7803-FC

MT-7801-FCMT-7801-FC
Fiber Optical Light SourceFiber Optical Light Source
Wavelength:1310nm / 1550nmWavelength:1310nm / 1550nm
ID
MOD
PERM Set
>2s OFF
1
2
3
4
5
6
7
1
2
3
45
67
4
Description
LCD
Power Button
1
2
3
4
5
6
7
Fiber optic adapter
Wavelength ID
Output wavelength switchbutton
Load modulation frequency
Charging Socket

1.Pull the battery cover 2.Installing the battery 3.Push the battery cover 4.Complete
Installing the battery
5

MT-7801-FCMT-7801-FC
Fiber Optical Light SourceFiber Optical Light Source
Wavelength:1310nm / 1550nmWavelength:1310nm / 1550nm
ID
MOD
PERM Set
>2s OFF
6
ID
MOD
PERM Set
>2s OFF
Press button will turn on the meter.
Press button againfor two seconds or more will
turn off the meter.
This meter hasa power-saving function, normal
boot and tenminutes without any operation, the device will automatically
shut down. Ifyou need to shield this function and enable themeter keeps
on working, onlyneed to press the button and hold when you
boot the instrument. After two seconds, the meter display will show "PERM"
which means permanent power on.
PERM Set
>2s OFF
PERM Set
>2s OFF
On/Off and Permanent On

MT-7801-FCMT-7801-FC
Fiber Optical Light SourceFiber Optical Light Source
Wavelength:1310nm / 1550nmWavelength:1310nm / 1550nm
ID
MOD
PERM Set
>2s OFF
7
ID
MOD
PERM Set
>2s OFF
Backlight Function
Under boot status,short press the
button, you cancontrol the backlight function
on or off. The backlightfunction is used when you want to use the meter
at night ordarker occasions.
PERM Set
>2s OFF

MT-7801-FCMT-7801-FC
Fiber Optical Light SourceFiber Optical Light Source
Wavelength:1310nm / 1550nmWavelength:1310nm / 1550nm
ID
MOD
PERM Set
>2s OFF
Select Wavelength
8
ID
MOD
PERM Set
>2s OFF
After pressing button, you can select
the required outputwavelengths. Details refer to
the parameters table.
The power meteror other measuring equipments
should correspond the wavelength of the light source.

MT-7801-FCMT-7801-FC
Fiber Optical Light SourceFiber Optical Light Source
Wavelength:1310nm / 1550nmWavelength:1310nm / 1550nm
ID
MOD
PERM Set
>2s OFF
9
ID
MOD
PERM Set
>2s OFF
MOD
Modulation wave output
After pressing button, you canload a
confirmed carrier frequency inthe current output
laser.
This instrument has three carrier frequencies for
selecting: 270Hz, 1KHz,2KHz.

MT-7801-FCMT-7801-FC
Fiber Optical Light SourceFiber Optical Light Source
Wavelength:1310nm / 1550nmWavelength:1310nm / 1550nm
ID
MOD
PERM Set
>2s OFF
Wavelength identification
10
ID
MOD
PERM Set
>2s OFF
ID
Press Button, it start thewavelength
recognition function, andthe upper left of the
display screen shows'ld'. When connect with the
power meter supporting wavelengthrecognition
function, it canshow the current output wavelength
of light source,and switch to measure the wavelength
automatically.

MT-7801-FCMT-7801-FC
Fiber Optical Light SourceFiber Optical Light Source
Wavelength:1310nm / 1550nmWavelength:1310nm / 1550nm
ID
MOD
PERM Set
>2s OFF
11
Power Indicator
Four levels indicationof power detection
Represents the remaining80%---100% electricity
Represents the remaining40%---80% electricity
Represents the remaining20%---40% electricity
Represents the remainingelectricity less than 20%

MT-7801-FCMT-7801-FC
Fiber Optical Light SourceFiber Optical Light Source
Wavelength:1310nm / 1550nmWavelength:1310nm / 1550nm
ID
MOD
PERM Set
>2s OFF
5V_500mA
12
Charge
The instrument has acharging function. When userechargeable
batteries and a lowbattery indication shows on theinstrument, you
should promptly shut down it and recharge.Long time undervoltage
will shorten the lifetimeof the rechargeablebattery.
Connect the AC adapterto the device correctly, it can charge
Automatically. Besides, computerUSB port can alsobe used for
charging. The battery remaining indicatorkeeps flashing during
charging. It willstop when the charging is finished. The battery
has finished the fastrecharge and can beused directly.If you do not
stop recharging at thistime, the in strumentwill continue the trickle
charge state, usingsmall current to supplynatural discharge. Butthis
process is not morethan 48 hours.
The instrument can stillbe used while charging. But donot plug in
the AC adapter whenit is not rechargeablebattery inside, or it will
cause a high temperatureand combustion, even explosion.

13
Meter Maintenance and Solution
General maintenance
Optical fiber connectthe adapter should avoid contacting with hard objects and keep clean.
Should be storedin a dry and ventilated place to avoid moisture.
When un usefor long time,should remove the batteries before storage.
Fault and solution
Failure name
Cannot boot Check the battery has
power or not
Check the battery has
power or not
Immediately shutdown
after booting
Failure Cause
Can display,
but all operationsare valid
The instrument program
is disordered
Solution
Replace or rechargethe batteries
Check the batteries are
installed correctly
Reboot
Cannot charge Using non-rechargeableable
battery. Reinstall the rechargeablebatteries
Garbled Incorrect reset Reboot

14
Detail Parameters
Output power
Optical connector
Stability
Modulation wave
0.05dBm/1 hour 0.1dBm/8 hour
270Hz 1KHz 2KHz
Low battery warning
Operation voice prompts
Auto off
Storage Temp. -20 ~+70 <90%RH
Operation Temp. -10 ~+60 <90%RH
Power source AA/LR6 1.5V X2 PCS not include
Backlight
Body protection
Battery life >40 hour
Size 165mm*80mm*35mm
Weight
Individual packing
280g
Color box
10 min can be cancelled
Low battery energy
Yes
Yes
Yes
MT-7801-FC
Wave source type
Wavelength
MT-7802-FC MT-7803-FC
FP
850nm/1300nm(MM)
>-10dBm
FC/PC
FP
1310nm/1550nm(SM)
>-5dBm
1310nm/1550nm@FP 1490nm@DFB
1310nm/1490nm/1550nm(SM)
>-5dBm


Optical Laser Source
MT-7801-FC/MT-7802-FC/MT-7803-FC

1
Wavelength:635-650nmWavelength:635-650nm
VISIBLE LASER RADIATIONVISIBLE LASER RADIATION
SEMICONDUCTOR LASERSEMICONDUCTOR LASER
AVOD EYE OR SKIN EXPOSUREAVOD EYE OR SKIN EXPOSURE
TO DIRECT OR SCATTERED RADIATIONTO DIRECT OR SCATTERED RADIATION
Wavelength:800-1700nmWavelength:800-1700nm
INVISIBLE LASER RADIATIONINVISIBLE LASER RADIATION
SEMICONDUCTOR LASERSEMICONDUCTOR LASER
AVOD EYE OR SKIN EXPOSUREAVOD EYE OR SKIN EXPOSURE
TO DIRECT OR SCATTERED RADIATIONTO DIRECT OR SCATTERED RADIATION
CLASS I LASER PRODUCTCLASS I LASER PRODUCT
This manual suits for next models
2
Table of contents
Other Pro's Kit Test Equipment manuals

Pro's Kit
Pro's Kit MT-7062 User manual

Pro's Kit
Pro's Kit 8PK-4103IN User manual

Pro's Kit
Pro's Kit MT-7801 User manual

Pro's Kit
Pro's Kit MT-7071 User manual

Pro's Kit
Pro's Kit NT-305 User manual

Pro's Kit
Pro's Kit MT-7068 User manual

Pro's Kit
Pro's Kit MT-7071N User manual

Pro's Kit
Pro's Kit MT-8006B User manual

Pro's Kit
Pro's Kit NT-309 User manual

Pro's Kit
Pro's Kit MT-7076 User manual