DIGITAL TIME SWITCH EN - 1
PCF-230
We thank you for the purchase of this Profile product.
Note: It is important that you read this manual carefully
before using the product Then keep this manual in a safe
place.
Note
Check that the voltage in-house corresponds to the
information on the type plate.
Do not expose the appliance to extremely high or low
temperatures.
Avoid contact with water.
Technical information
Working voltage: 230V (50Hz) – 250V
Maximum resistive capacity: 3500W/16A
Maximum inductive capacity: 625 VA ind.
Programming: periods of min. 60 seconds.
Day/week program.
Random function.
Explanatory terms
Resistive appliances are appliances that consume the
same current quantity for the whole duration. E.g. lights.
Inductive appliances, on the other hand, consume much
more current at the start than in normal operation. This
includes coffee-makers, boilers, heating appliances, etc.
If the inductive appliance exceeds the inductive capacity
of the time switch the appliance may not be connected to
it. If it is the switching contact in the time switch will
prematurely fail. This falls outside the guarantee
conditions.
Rechargeable battery
A rechargeable battery ensures that the set time and all
other settings are saved in the case of a power failure (to a
maximum of 150 hours with a fully charged battery). If the
battery appears to be nearly empty on purchasing, plug the
time switch into the plug socket for 5 minutes before
starting programming.
12- or 24-hour display
You can select either 12-hour or 24-hour display. To switch
between the 12-hour display and 24-hour display keep the
“h key” pressed together with the “+/-1h” key
Setting the time
Keep the key pressed then press the “1-7 key” to set
the correct day. (1:Monday, 7:Sunday)
Keep the key pressed then press the “h key” to set
the correct hour.
Keep the key pressed then press the “m key” to
set the correct minute.
ON/OFF switching program
You can set up to 20 programs with the option of
repeating them daily or weekly.
If you press the PROG key once, “--:--“ appears with
each day of the week on the display.
Press the “1-7 key” repeatedly to set the day(s) on
which the program must activate. You can also
select combinations of days along with separate
weekdays. Press PROG to confirm and proceed with
setting the hour.
Press the “h key” to set the hour at which the
program must activate then PROG to set the minute.
Press the “m key” to set the minute at which the
program must activate.
With the key you can switch between 
(switching on) and (switching off)
Always confirm a command with PROG.
Repeat the steps above to set a maximum of 20
programs.
The time switch automatically goes back to the
current operating mode and displays the time.
NOTE: The number of memory locations still free is
indicated by e.g. FR18. If all memory locations are
occupied FR00 appears.
Insert the plug of the device to be switched in the plug
socket part of the time switch. If the connected
appliance has an “on-off” switch make sure this is “on”.
Deleting a set program
Press the PROG key 1 to 20 times until the required
switching command appears. Then press the “h
key” and the “m key” until you see “--:--“ appear.
Keep the key pressed for 3 seconds to delete the
switching time. The time switch then goes back to
the current operating mode.
NOTE: If you press the RESET key the factory settings
are automatically reset.
Random function
This function randomly switches the timer on and off.
This function ensures the timer generates a random
delay of 1 to 45 minutes for the set times.
Press RND to activate the random function.
This function can be switched off by again
pressing RND.
DIGITAL TIME SWITCH EN - 2
PCF-230
Setting of summertime and wintertime
Press the“+/-1h” key once to set summertime or
wintertime. The current time will advance or go back an
hour. When summertime is set +1h appears on the display.
Safety instructions
The importer accepts no responsibility for damage claims
with respect to objects or persons that result from incorrect
use or non-compliance with the safety instructions. All
damage claims in such cases will be declared null and
void.
Guarantee conditions
The guarantee period for the PCF-230 amounts to 2 years
and commences on the date of purchase. During this
guarantee period Eltra nv will repair any defects
attributable to material or production faults. Eltra nv may
choose to either repair or replace a defective appliance.
ELTRA NV is not obliged to repair or replace appliances if
they have become defective as a result of damage,
inappropriate use, or modifications or adaptations made
after the purchase date.
Take any defective appliance together with the original
receipt back to the shop where the appliance was sold.
Always add a note with a description of the problem.
Damage
ELTRA NV can under no circumstances whatsoever be
held responsible for damage of whatever nature if the
appliance was not correctly installed according to the
specified installation instructions, nor for damage as a
result of unforeseen circumstances such as natural
disasters, lightening strike, etc. All such resulting costs are
consequently at the expense of the buyer and are not
covered by the guarantee conditions.
www.eltra.eu
www.profileDIY.com
Eltra nv, Pachtgoedstraat 2, 9140 Temse, BELGIUM
Eltra DIYeuronet/Elar bv, Ambachtsstraat 8, 5405 AM Uden,
THE NETHERLANDS

Other Profile Timer manuals

Profile 010200152 User manual

Profile

Profile 010200152 User manual

Profile 010201027 User manual

Profile

Profile 010201027 User manual

Profile 010200280 User manual

Profile

Profile 010200280 User manual

Profile 840000016 User manual

Profile

Profile 840000016 User manual

Profile 840000017 User manual

Profile

Profile 840000017 User manual

Profile 840000015 User manual

Profile

Profile 840000015 User manual

Profile 840000020 User manual

Profile

Profile 840000020 User manual

Popular Timer manuals by other brands

Omron H3CR-AP instruction sheet

Omron

Omron H3CR-AP instruction sheet

Ateg H3DT manual

Ateg

Ateg H3DT manual

Simex SLC-94 user manual

Simex

Simex SLC-94 user manual

Crouzet TIMER 812 quick start guide

Crouzet

Crouzet TIMER 812 quick start guide

Elkay 374C-1 Instruction guide

Elkay

Elkay 374C-1 Instruction guide

Digi DT800 operating instructions

Digi

Digi DT800 operating instructions

Sport-thieme 282 2408 manual

Sport-thieme

Sport-thieme 282 2408 manual

Prime Wire & Cable TNI2412 quick start guide

Prime Wire & Cable

Prime Wire & Cable TNI2412 quick start guide

Honeywell ST9100S installation instructions

Honeywell

Honeywell ST9100S installation instructions

TFA TRILE TIME XL 38.2023 operating instructions

TFA

TFA TRILE TIME XL 38.2023 operating instructions

Grasslin Towerchron QM1 Installation and user instructions

Grasslin

Grasslin Towerchron QM1 Installation and user instructions

Perry Electric ASTRO-LUX-TIME Instructions for installation and use

Perry Electric

Perry Electric ASTRO-LUX-TIME Instructions for installation and use

Electrovision E304CF user manual

Electrovision

Electrovision E304CF user manual

STI LT-1UL quick start guide

STI

STI LT-1UL quick start guide

CDC Elettromeccanica TX40 manual

CDC Elettromeccanica

CDC Elettromeccanica TX40 manual

claber aquauno LOGICA PLUS instruction manual

claber

claber aquauno LOGICA PLUS instruction manual

Velleman PEREL E305WON user manual

Velleman

Velleman PEREL E305WON user manual

Wachendorff TI327401 manual

Wachendorff

Wachendorff TI327401 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.