manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Promax
  6. •
  7. Measuring Instrument
  8. •
  9. Promax TVHUNTER+ User manual

Promax TVHUNTER+ User manual

DIGITAL TERRESTRIAL TELEVISION HUNTER
TVHUNTER+
TVHUNTER+: Aligning antennas fast and easily
External antenna power
The meter includes a power supply for
external active antennas or preampli-
fiers. It is possible to select 5 V, 12 V,
18 V or 24 V depending on the require-
ments of the external device.
The TVHUNTER+ is a small handheld easy to use meter, that has
been designed for the installation of Digital Terrestrial Television
for DVB-T, DVB-T2 and ISDB-T/TB systems. The TVHUNTER has
become a widely popular tool for DVB-T antenna alignment. The key
factors have been its small pocket size and ease of use, still offering
proper measurements. As a natural evolution, TVHUNTER+ is now
available allowing full compatibility with DVB-T2 and ISDB-T/TB
standards for the High Definition digital terrestrial TV broadcasting.
It detects signals from any analogue or
digital terrestrial broadcast with the
built-in wide band detector. In this mode
the meter shows information about the
received signal power in the form of two
graphic bars with two different time cons-
tants and an audible indicator to help
align the aerial to the optimum detection.
SCAN.- The TVHUNTER+ allows a
broadcast search in DVB-T and DVB-T2.
Easy to use
In this mode the TVHUNTER+ shows information about the received digital channel
and programmes included in the service list as well.
2.- Identification
1.- Detection
It allows fine pointing the reception antenna, to optimise the digital measurements such as
channel power, MER, VBER and CBER on preselected channels. All information is
displayed on the screen in a very convenient way so that optimising the aerial alignment
becomes really easy. MER in particular is shown numerically and through a graphic bar as
well. VBER and CBER can be shown together or graphically.
3.-Adjustment
Function 2: Identification
Detection point
(Terrestrial multiplex
Name)
Frequency
Network
Channel
Services
Remaining battery level indicator
External supplied voltage
Indicates whether the
signal is locked or not
Frequency
Nr. current service
ISDB-T/TB
TVHUNTER +
PROMAX ELECTRONICA, S. L.
Francesc Moragas, 71 * 08907 L'HOSPITALET DE LLOBREGAT * SPAIN
Tel: (+34) 93 184 77 02 * Fax: (+34) 93 338 11 26 * e-mail:[email protected] * http://www.promaxelectronics.com
Specifications subject to change without notice 04-15
TUNING
RF INPUT
DIGITAL SIGNAL MEASUREMENTS
Frequency range 170 MHz to 858 MHz (UHF)
Measurement points 50 maximum
Impedance 75 Ω
Connector Universal, including BNC, DIN and F interchangeable adapter
Level range 40 dBµV to 100 dBµV
Maximum signal level DC to 100 Hz 30 Vrms / 170 MHz to 858 MHz 120 dBµV
SPECIFICATIONS TVHUNTER+
ISDB-T/TB Power, CBER, VBER, MER, Link Margin
Presentation Numeric and level bar
POWER MEASUREMENT RANGE
ISDB-T/TB 45 dBµV to 100 dBµV
EXTERNAL UNITS POWER SUPPLY Through the RF input connector
BACK-LIGHT DISPLAY Automatic
Output voltage 5 V, 12 V, 15 V, 24 V ± 1 V
Maximum external output power 5 W (2.5 W for +5 V)
POWER SUPPLY
Battery 7.4 V 2.2 Ah Li-Ion battery
Low battery indication Acoustic indication and message on the display
Charger Built-in. It disconnects power supply when charging process ends
Autonomy 6 hours typically, without powering any amplifier through the external power supply
Charging time 90 min. approx. starting from a complete discharge (instrument off), within the
margin of tolerated temperatures
Mains adapter 90 - 250 V / 50-60 Hz (included), 12 V DC, 20 W
OPERATING ENVIRONMENTAL CONDITIONS
Altitude Up to 2000 m.
Temperature range From 5 °C to 40 °C
Max. relative humidity 80 % (Up to 31 °C), decreasing lineally up to 50 % at 40 °C
MECHANICAL FEATURES
Dimensions 180 mm (W) x 95 mm (H) x 50 mm (D)
Weight 480 g
ACCESSORIES
Mains power adapter, F to BNC/DIN/F adapters, Mains cord, Car lighter adapter, TVHUNTER+ carrying suitcase, TVHUNTER + carrying
belt, USB 2.0 connector cable, TVHUNTER+ Quick Reference Guide
ISDB-T/TB SIGNAL PARMETERS
Code Rate 2/3, 1/2, 3/4, 5/6, 7/8
Spectral inversion ON, OFF
Demodulation QPSK, 16 QAM, 64 QAM
Layer A, B, C
Mode 1 (2k), 2 (4k), 3 (8k)
Guard Interval 1/4, 1/8, 1/16, 1/32
Configuration of test points By means of USB 2.0 to PC (Cable and software included)

Other manuals for TVHUNTER+

2

Other Promax Measuring Instrument manuals

Promax 27 User manual

Promax

Promax 27 User manual

Promax RANGER Neo Lite User manual

Promax

Promax RANGER Neo Lite User manual

Promax HD Ranger + User manual

Promax

Promax HD Ranger + User manual

Promax Prolite-50 User manual

Promax

Promax Prolite-50 User manual

Promax PROWATCH Neo 2 User manual

Promax

Promax PROWATCH Neo 2 User manual

Promax RANGERNeo 2 ISDB-T User manual

Promax

Promax RANGERNeo 2 ISDB-T User manual

Promax CABLE RANGER User manual

Promax

Promax CABLE RANGER User manual

Promax RANGER Neo 3 User manual

Promax

Promax RANGER Neo 3 User manual

Promax PROMAX-8+ User manual

Promax

Promax PROMAX-8+ User manual

Promax PROLITE-57 User manual

Promax

Promax PROLITE-57 User manual

Promax 26 User manual

Promax

Promax 26 User manual

Promax AE-166 User manual

Promax

Promax AE-166 User manual

Promax PROMAX-4 User manual

Promax

Promax PROMAX-4 User manual

Promax RANGERNeo 4 User manual

Promax

Promax RANGERNeo 4 User manual

Promax PROLITE-57 User manual

Promax

Promax PROLITE-57 User manual

Promax HD RANGER Eco User manual

Promax

Promax HD RANGER Eco User manual

Promax RANGER mini User manual

Promax

Promax RANGER mini User manual

Promax Cable Ranger+ User manual

Promax

Promax Cable Ranger+ User manual

Promax PROPOWER - 5 User manual

Promax

Promax PROPOWER - 5 User manual

Promax OTDR Series User manual

Promax

Promax OTDR Series User manual

Promax RANGER Neo Lite User manual

Promax

Promax RANGER Neo Lite User manual

Promax RANGER Neo 2 User manual

Promax

Promax RANGER Neo 2 User manual

Promax NGQ Series User manual

Promax

Promax NGQ Series User manual

Promax HD Ranger + User manual

Promax

Promax HD Ranger + User manual

Popular Measuring Instrument manuals by other brands

ZURN AquaSense AV ZER Series Installation, operation, maintenance and parts manual

ZURN

ZURN AquaSense AV ZER Series Installation, operation, maintenance and parts manual

JENCO VisionPlus pH6810 Operation manual

JENCO

JENCO VisionPlus pH6810 Operation manual

Wolfgang Warmbier SRM 110 user manual

Wolfgang Warmbier

Wolfgang Warmbier SRM 110 user manual

EKM Omnimeter I installation instructions

EKM

EKM Omnimeter I installation instructions

Autonics MP5M Series product manual

Autonics

Autonics MP5M Series product manual

Wintech WP-3000 Series instruction manual

Wintech

Wintech WP-3000 Series instruction manual

Extech Instruments CO220 user guide

Extech Instruments

Extech Instruments CO220 user guide

PCB Piezotronics IMI SENSORS ICP HT628F01 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS ICP HT628F01 Installation and operating manual

DMP Electronics XTLplus SERIES Installation and programming guide

DMP Electronics

DMP Electronics XTLplus SERIES Installation and programming guide

NOVOTEST KRC-M2 Operation manual

NOVOTEST

NOVOTEST KRC-M2 Operation manual

Newport INFCP quick start

Newport

Newport INFCP quick start

HDE DT 1130 user manual

HDE

HDE DT 1130 user manual

Tanita SC-240MA instruction manual

Tanita

Tanita SC-240MA instruction manual

Kübler Ants LEB02 manual

Kübler

Kübler Ants LEB02 manual

Enel X JuiceMeter installation manual

Enel X

Enel X JuiceMeter installation manual

TFA KLIMA GUARD 30.5010 instruction manual

TFA

TFA KLIMA GUARD 30.5010 instruction manual

SBC Saia PCD AWD3D5WS Assembly and operating instructions

SBC

SBC Saia PCD AWD3D5WS Assembly and operating instructions

Pendulum 6688 user manual

Pendulum

Pendulum 6688 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.