ProSoft PLX51-PBS User manual

PLX51-PBS
PROFIBUS DP Slave to
EtherNet/IP™ or Modbus®Gateway
August 7, 2020
USER MANUAL

Preface
Page 2 of 111
Your Feedback Please
We always want you to feel that you made the right decision to use our products. If you have suggestions, comments,
compliments or complaints about our products, documentation, or support, please write or call us.
ProSoft Technology, Inc.
+1 (661) 716-5100
+1 (661) 716-5101 (Fax)
www.prosoft-technology.com
PLX51-PBS User Manual
August 7, 2020
ProSoft Technology®, is a registered copyright of ProSoft Technology, Inc. All other brand or product names are or may be
trademarks of, and are used to identify products and services of, their respective owners.
In an effort to conserve paper, ProSoft Technology no longer includes printed manuals with our product shipments. User
Manuals, Datasheets, Sample Ladder Files, and Configuration Files are provided at our website:
www.prosoft-technology.com
Content Disclaimer
This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of
these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and
complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use
thereof. Neither ProSoft Technology nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the
information contained herein. Information in this document including illustrations, specifications and dimensions may
contain technical inaccuracies or typographical errors. ProSoft Technology makes no warranty or representation as to its
accuracy and assumes no liability for and reserves the right to correct such inaccuracies or errors at any time without
notice. If you have any suggestions for improvements or amendments or have found errors in this publication, please
notify us.
No part of this document may be reproduced in any form or by any means, electronic or mechanical, including
photocopying, without express written permission of ProSoft Technology. All pertinent state, regional, and local safety
regulations must be observed when installing and using this product. For reasons of safety and to help ensure compliance
with documented system data, only the manufacturer should perform repairs to components. When devices are used for
applications with technical safety requirements, the relevant instructions must be followed. Failure to use ProSoft
Technology software or approved software with our hardware products may result in injury, harm, or improper operating
results. Failure to observe this information can result in injury or equipment damage.
© 2020 ProSoft Technology. All Rights Reserved.
Printed documentation is available for purchase. Contact ProSoft Technology for pricing and availability.
For professional users in the European Union
If you wish to discard electrical and electronic equipment (EEE), please contact your dealer or supplier for
further information.
Warning –Cancer and Reproductive Harm –www.P65Warnings.ca.gov
Agency Approvals and Certifications
Please visit our website: www.prosoft-technology.com

Preface
Page 3 of 111
CONTENTS
Your Feedback Please.............................................................................................................2
Content Disclaimer.................................................................................................................2
1. Preface ...............................................................................................................................6
Introduction.................................................................................................................6
Features.......................................................................................................................7
Additional Information................................................................................................8
Support........................................................................................................................8
2. Installation .........................................................................................................................9
Module Layout ............................................................................................................9
Module Mounting .....................................................................................................11
PROFIBUS DP Port (RS485)........................................................................................12
3. Setup ................................................................................................................................13
Installing the Configuration Software .......................................................................13
Network Parameters.................................................................................................14
GSD File Management...............................................................................................18
Creating a New Project..............................................................................................21
PLX51-PBS Parameters..............................................................................................23
General...............................................................................................................23
Modbus..............................................................................................................24
Modbus Addressing ...........................................................................................25
PROFIBUS Slave Configuration...........................................................................27
Logix ...................................................................................................................28
Advanced ...........................................................................................................30
Adding PROFIBUS DP Devices ...................................................................................31
General...............................................................................................................32
PROFIBUS Configuration....................................................................................33
DPV1...................................................................................................................34
User Parameters ................................................................................................35
Slot Configuration ..............................................................................................36
Slot Configuration - General .....................................................................................................38
Slot Configuration –Logix Specific............................................................................................40

Preface
Page 4 of 111
Slot Configuration –Modbus Specific.......................................................................................40
Start-up Parameters...........................................................................................41
DPV1 Objects .....................................................................................................42
DPV1 Alarms ......................................................................................................44
Module Download.....................................................................................................46
Logix Configuration ...................................................................................................47
EDS AOP (Logix V21+) ........................................................................................47
Generic Module Profile (Logix Pre-V21) ............................................................50
Multi-Connection...............................................................................................53
Logix Mapping ...........................................................................................................54
4. SD Card.............................................................................................................................58
Firmware ...................................................................................................................59
Configuration.............................................................................................................60
Manual Copy......................................................................................................61
PLX50 Configuration Utility................................................................................62
5. Operation.........................................................................................................................63
Logix Operation.........................................................................................................63
PROFIBUS DP - Slave ..........................................................................................63
General Status...........................................................................................................................63
General Control.........................................................................................................................66
Status and DPV0 Data Exchange...............................................................................................67
DPV1 Class 1 Messaging (MS1) .................................................................................................70
Alarming....................................................................................................................................71
Modbus Operation....................................................................................................73
PROFIBUS DP - Slave ..........................................................................................73
Slave Device Status ...................................................................................................................73
DPV0 Data Exchange.................................................................................................................74
DPV1 Class 1 Messaging (MS1) .................................................................................................75
Alarming....................................................................................................................................75
Modbus Auxiliary Map..............................................................................................................77
Firmware upgrading..................................................................................................79
6. Diagnostics.......................................................................................................................81
LEDs ...........................................................................................................................81
Module Status Monitoring........................................................................................82

Preface
Page 5 of 111
PLX51-PBS ..........................................................................................................83
General......................................................................................................................................84
Slave Status...............................................................................................................................87
Modbus Statistics......................................................................................................................88
Ethernet Clients ........................................................................................................................89
TCP/ARP ....................................................................................................................................89
Device Status......................................................................................................90
General –Slave Mode...............................................................................................................91
Statistics....................................................................................................................................93
PROFIBUS Packet Capture.........................................................................................96
Modbus Packet Capture............................................................................................99
Module Event Log....................................................................................................101
Web Server..............................................................................................................102
7. Technical Specifications.................................................................................................103
Dimensions..............................................................................................................103
Electrical ..................................................................................................................104
Ethernet...................................................................................................................104
PROFIBUS DP ...........................................................................................................105
Agency Approvals and Certifications ......................................................................105
8. PROFIBUS DP..................................................................................................................106
Introduction.............................................................................................................106
PROFIBUS master and slave ....................................................................................107
PROFIBUS master class 1 (DPM1) or class 2 (DPM2) ..............................................108
Cyclic communication .............................................................................................108
Acyclic communication............................................................................................109
Topology of PROFIBUS DP.......................................................................................109
PROFIBUS DP cable description ..............................................................................110
PROFIBUS DP connector description.......................................................................110
9. Support, Service & Warranty.........................................................................................111
Contacting Technical Support .................................................................................111
Warranty Information.............................................................................................111

Preface
Page 6 of 111
1. PREFACE
INTRODUCTION
This user manual describes the installation, operation, and diagnostics of the PROFIBUS DP
Slave to EtherNet/IP™ or Modbus Gateway module. The module will hereafter be collectively
referred to as PLX51-PBS.
The PLX51-PBS can operate only as one or more (emulates up to 10) PROFIBUS DPV0/DPV1
Slaves. This allows EtherNet/IP or Modbus devices to exchange process, alarming, and
diagnostic data with other PROFIBUS DP Master(s).
Figure 1.1 –Typical PLX51-PBS PROFIBUS Slave Architecture

Preface
Page 7 of 111
FEATURES
The PLX51-PBS has two Ethernet ports allowing for either a Linear or Ring (Device Level Ring
–DLR) Ethernet topology. The Ethernet ports can also be set up for port mirroring allowing
for better fault analysis.
The PLX51-PBS can synchronize to an NTP Server, allowing for automatic time
synchronization. The PLX51-PBS also supports an onboard non-volatile event log for improved
fault finding.
PROFIBUS Slave
The PLX51-PBS can emulate up to 10 PROFIBUS slave devices, providing up to 1536 bytes of
Input and Output Cyclic I/O data between EtherNet/IP or Modbus devices and a PROFIBUS DP
master. Each slave device emulated by the PLX51-PBS can be configured to provide DPV0 data
exchange with a PROFIBUS Master on the network.
The data is formatted into the engineering units for use in a Logix platform by using the
automatically generated mapping imports for Logix User Defined Data Types (UDTs).
Each emulated slave can also be configured to exchange DPV1 Class 1 data by mapping Logix
tags for the relevant DPV1 data exchange. Each emulated slave is able to provide DPV1
alarming for the PROFIBUS Master.
The PLX51-PBS provides a range of statistics and tools to provide a detailed diagnostic
overview of each emulated slave which speeds up fault finding. The PLX50 Configuration
Utility allows you to perform a PROFIBUS DP packet capture of the running Fieldbus which
can be used to analyze the bus behaviour and packets received. The PLX51-PBS also provides
global and device specific statistics.

Preface
Page 8 of 111
ADDITIONAL INFORMATION
The following documents contain additional information that can assist you with installation
and operation.
Resource
Link
PLX50 Configuration
Utility Installation
www.prosoft-technology.com
PLX51-PBS User Manual
PLX51-PBS Datasheet
www.prosoft-technology.com
Table 1.1 - Additional Information
SUPPORT
Technical support is provided via the Web (in the form of user manuals, FAQ, datasheets etc.)
to assist with installation, operation, and diagnostics.
For additional support, use either of the following:
Resource
Link
Contact Us link
www.prosoft-technology.com
Support email
support@prosoft-technology.com
Table 1.2 –Support Details

Installation
Page 9 of 111
2. INSTALLATION
MODULE LAYOUT
The PLX51-PBS has one RS485 PROFIBUS DP port as well as two Ethernet ports. The Ethernet
cable must be wired according to industry standards, which can be found in the Additional
Information section of this document.
The module provides six diagnostic LEDs, as shown in the front view figure below. These LEDs
are used to provide information regarding the module system operation, the Ethernet
interface, and the PROFIBUS network status.
Figure 2.1 –PLX51-PBS Side and Front view

Installation
Page 10 of 111
At the bottom of the module, there is one 3-way power connector.
Figure 2.2 –PLX51-PBS Power connector
The PLX51-PBS has an input voltage range of 10 to 36 VDC, applied to the module via the
power connector. The power connector also provides an Earth connection for the PLX51-PBS.
NOTE: It is recommended to always have a good clean earth connected to the
module via the Earth connector on the power connector.
At the back of the module, there is slot for a SD memory card. The module provides four DIP
switches at the top of the enclosure as shown in the top view figure below.
Figure 2.3 –PLX51-PBS Top view
DIP Switch
Description
DIP 1
Used to force the module into “Safe Mode”. When in “Safe Mode”, the module will
not load the application firmware and will wait for new firmware to be downloaded.
This should only be used in the rare occasion when a firmware update was interrupted
at a critical stage.
DIP 2
This forces the module into DHCP mode which is useful when you have forgotten the
IP address of the module.
DIP 3
This is used to lock the configuration from being overwritten by the PLX50
Configuration Utility. When set, the PLX50 Configuration Utility will not be able to
download to the PLX51-PBS module.
DIP 4
When this is set, a module reboot will set the module Ethernet IP address to
192.168.1.100 and network mask 255.255.255.0. You can then switch the DIP switch
off and assign the module a static IP address if needed.
Table 2.1. - DIP Switch Settings

Installation
Page 11 of 111
MODULE MOUNTING
The PLX51-PBS provides a DIN rail clip to mount onto a 35mm DIN rail.
Figure 2.4 - DIN rail specification
The DIN rail clip is mounted at the back of the module as shown in the figure below. Use a flat
screw driver to pull the clip downward. Once the module is mounted onto the DIN rail, the
clip must be pushed upward to lock the module onto the DIN rail.
Figure 2.5 - DIN rail mouting

Installation
Page 12 of 111
PROFIBUS DP PORT (RS485)
The PROFIBUS DP port uses a female DB9 connector. This provides connection for the
communication conductors, cable shielding, and +5Vdc output power.
Figure 2.6 –PLX51-PBS PROFIBUS DP (RS485) DB9 connector
Pin
Signal
Description
1
-
Not connected
2
-
Not connected
3
RxD/TxD-P
Data received and transmit (+)
4
CNTR-P
Control signal to repeater (+)
5
DGND
Reference potential for +5Vdc
6
VP
+5Vdc for terminating resistors (active termination)
7
-
Not connected
8
RxD/TxD-N
Data received and transmit (-)
9
-
Not connected
Table 2.2 –DB 9 Connector layout

Setup
Page 14 of 111
NETWORK PARAMETERS
The PLX51-PBS has DHCP (Dynamic Host Configuration Protocol) enabled as factory default.
Thus, a DHCP server must be used to provide the module with the required network
parameters (IP address, subnet mask, etc.). There are a number of DHCP utilities available,
however it is recommended that the DHCP server in the PLX50 Configuration Utility is used.
Within the PLX50 Configuration Utility environment, the DHCP server can be found under the
Tools menu.
Figure 3.2. - Selecting DHCP Server
Once opened, the DHCP server listens on all available network adapters for DHCP requests
and display their corresponding MAC addresses.
Figure 3.3. - DHCP Server
NOTE: If the DHCP requests are not displayed in the DHCP Server, it may be
due to the local PC’s firewall. During installation, the necessary firewall rules
are automatically created for the Windows firewall. Another possibility is that
another DHCP Server is operational on the network and it has assigned the IP
address.

Setup
Page 15 of 111
To assign an IP address, click on the corresponding ASSIGN button. The Assign IP Address for
MAC window opens.
Figure 3.4. - Assigning IP Address for MAC
The required IP address can be either entered, or a recently used IP address can be selected
by clicking on an item in the Recent list.
If the Enable Static checkbox is checked, the IP address will be set to static after the IP
assignment, thereby disabling future DHCP requests.
Once you click OK, the DHCP server will automatically assign the IP address to the module and
then read the Identity object product name from the device.
The successful assignment of the IP address by the device is indicated by the green
background of the associated row.
Figure 3.5. - Successful IP address assignment
It is possible to force the PLX51-PBS back into DHCP mode by powering up the device with DIP
switch 2 set to the On position.
A new IP address can then be assigned by repeating the previous steps.
NOTE: It is important to return DIP switch 2 back to Off position, to avoid the
module returning to a DHCP mode after the power is cycled again.

Setup
Page 16 of 111
In addition to the setting the IP address, a number of other network parameters can be set
during the DHCP process. These settings can be viewed and edited in the PLX50 Configuration
Utility Application Settings, in the DHCP Server tab.
Once the DHCP process is complete, the network settings can be set using the Ethernet Port
Configuration via the Target Browser.
The Target Browser can be accessed under the Tools menu.
Figure 3.6. - Selecting the Target Browser
The Target Browser automatically scans the Ethernet network for EtherNet/IP devices.
Figure 3.7. - Target Browser

Setup
Page 17 of 111
Right-clicking on a device, reveals the context menu, including the Port Configuration option.
Figure 3.8. - Selecting Port Configuration
The Ethernet port configuration parameters can be modified using the Ethernet Port
Configuration window.
Figure 3.9. - Port Configuration
Alternatively, these parameters can be modified using Rockwell Automation’s RSLinx
software.

Setup
Page 18 of 111
GSD FILE MANAGEMENT
Each PROFIBUS device has a GSD file that is required to provide information needed to
configure the device for data exchange. The PLX50 Configuration Utility manages the GSD
library which is used for adding devices to the PLX51-PBS.
1The GSD File Management Tool is opened by selecting GSD File Management under
the Tool menu in the configuration utility.
Figure 3.10 –Launching the GSD File Management Tool
2Once the tool opens, a list of registered slave devices are displayed, using their GSD
files.
Figure 3.11 –GSD File Management Tool

Setup
Page 19 of 111
3To add a GSD file, select the Add option under the GSD File menu.
Figure 3.12 –GSD File Adding
4Select the required GSD file and click OPEN.
Figure 3.13 –Adding GSD File
5Once the file has been selected, the GSD File Management tool adds the slave device
to the device list and recompile the GSD catalog.

Setup
Page 20 of 111
A GSD catalog can be exported from another PLX50 Configuration Utility by exporting the GSD
catalog from one PLX50 Configuration Utility, and importing it in another. This is done by
selecting either Import or Export under the Catalog menu as shown below:
Figure 3.14 –GSD Catalog import/export
Table of contents
Other ProSoft Gateway manuals

ProSoft
ProSoft PLX51-PBM User manual

ProSoft
ProSoft ProLinx 104S User manual

ProSoft
ProSoft PLX51-DF1-ENI User manual

ProSoft
ProSoft PLX32-EIP-MBTCP-UA User manual

ProSoft
ProSoft ProLinx Wireless 6201-WA-MNET User manual

ProSoft
ProSoft ICX35-HWC User manual

ProSoft
ProSoft PLX51-DNPS User manual

ProSoft
ProSoft PLX51-DNPM User manual

ProSoft
ProSoft PLX51-DL-232 User manual