PureAir HVAC User manual

Owner’s Manual

2
Welcome
Table of Contents
Thank you for your purchase of the pureAir HVAC Air Purication
Enhancement System. This unit is designed to be installed into an existing
HVAC system, and used as a virtually maintenance-free enhancement to
current air purication technology.
Please read and follow all service procedures outlined in this manual.
Please record the name and phone number of your Distributor/Contractor.
Name_____________________________________________________________________
Phone #: __________________________________________________________________
Please record the serial number of your pureAir HVAC.
Serial #: ___________________________________________________________________
About .......................................................... 3
Cautions & Warnings ............................................. 3
Product Contents ................................................ 4
Installation Hardware ............................................. 4
Replacement Parts ............................................... 4
Installation Tools ................................................. 5
Installation Requirements.......................................... 5
Installation .....................................................6-7
Maintenance.................................................... 8
Cell Disposal .................................................... 8
Changing the Cell ............................................... 9
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

3
About pureAir HVAC
pureAir HVAC is a new generation Air Purication Enhancement System.
Designed to work with existing purication technology to reduce odors,
smoke, and a broad spectrum of indoor air contaminants.
pureAir HVAC is easily mounted into air conditioning and/or heating systems
where contaminants can grow. When the HVAC system is in operation,
pureAir HVAC produces the PCO (Photocatalytic Oxidation) Process
consisting of hydroperoxides and superoxide ions, which are friendly oxidizers
that revert back to oxygen and hydrogen after the oxidation of a pollutant.
Cautions & Warnings
WARNING: UV Light in operation. Disconnect unit from power
supply before servicing. Failure to follow warnings may result in
severe eye damage.
CAUTION: To reduce the risk of shock, this equipment may have
a grounding type plug with a third (grounding) pin. This plug will
only t into a grounding type power outlet. If the plug does not t
into the outlet, contact a qualied electrician or HVAC specialist to
install the proper outlet. DO NOT alter the plug in any way.

4
Product Contents
Installation Hardware
Replacement Parts
(8) #8 3/4” Hex Head Self-Tapping Screw
(4) #8 - 32 Knurled Thumb Nuts
(4) #6 - 32, 3”Threaded Bolt
(4) #6 - 32 Toggle Bolt Wall Anchor
(2) 18 - 22 Gauge Wire Nut (only used with hard-wiring)
Your HVAC unit requires no periodic maintenance beyond the normal
replacement of the PCO Cell on an annual basis. The cell is working when
the indicator lights are on. For optimal performance, annual maintenance
is encouraged.
If you need a cell replacement, contact your Distributor/Contractor and
use the list below to reference your required Cell Type.
Cell Type Part Number
5” Cell CELL-HV-05-O3-GT
9” Cell CELL-HV-09-O3-GT
14” Cell CELL-HV-14-O3-GT
DBI Cell UX-COMM-DBI 12V
Ballast Housing &
Mounng Plate
Replaceable PCOTM Cell
(Includes UV Lamp)
Power Supply
(120 VAC to 24 VAC/VDC)
DBI Mounng Bracket
(Oponal Addion)
2 DBI Cells
(Oponal Addions)

5
pureAir HVAC Supply Plenum
Installation Tools
Installation Requirements
pureAir HVAC Return Plenum
(Recommended Option)
Utility Knife
Tin Snips
Phillips Head Screwdriver
5/16” Wrench/Socket
Power Drill/Driver
1/8” Drill Bit
The unit should be installed after the air handler in
the HVAC system in the supply plenum.*
*Additional pureAir HVAC units are recommended in
the Return Plenum for added protection and to keep
the internal parts clean.
An opening of will need to be cut into the existing
duct work to install the unit properly.
Electrical Requirements
The unit is powered by connection to 24VAC
from HVAC System or 24VDC from
120VAC transformer (included).
WARNING: Long term use of an extension cord is not recommended due to safety considerations.

6
Installation
1. Locate a suitable area of duct for
the installation.
2. Cut away any insulation to expose
the duct.
3. Use the Mounting Plate to trace the
main hole and the Eight (8) Screw
Hole Locations.
4. Use the Drill with 1/8” Drill Bit to make
Four (4) holes around the marked
cut out (used in Step 5) as well as
the Eight (8) Screw Holes (used in
Step 7).
5. Use the Tin Snips to cut around the
traced hole.
6. Remove the backing from the
Mounting Plate Adhesive Gasket
and press onto the duct over the
cut opening.

7
Installation (Continued)
7. (A) Install the Mounting Plate to the
Duct using the Eight (8) Self-Tapping
Screws.
(B) For Fiberglass Ductwork, attach using
the 2” Bolts with Toggle Bolt Anchors.
8. Place the unit through the hole
and rotate is so that airow always
passes through the honeycomb. The
mounting plate and unit head are
set up to allow for any orientation.
Alternatively, the PCO Cell can be
reoriented on the back to allow the
Power Cable to always face the the
ideal direction. (Review “Changing
the Cell” on Page 9 for instructions)
9. Thread the four (4) Knurled Thumb
Nuts onto the Threaded Bolts,
making sure a seal is created along
the backside of the Ballast Housing.
10. Plug the power cable into your unit
and then into the outlet.

8
DBI Cell Installation (Optional)
1. Unplug the unit’s power cord from
the outlet.
←
←
←
2. Remove the Knurled Thumb Nuts and
unit from the duct.
3. Remove one (1) screw holding
the cell on the rear of the Ballast
Housing, beneath the Molex
connector.
4. Place the Hook-end of the DBI Cell
Mounting Bracket over the back of
the PCO Cell, with the screw hole
overlapping the open screw hole of
the Ballast Housing.
NOTE: Do not cover the open cell sides.
5. Replace the screw to hold the DBI
Cell Mounting Bracket in place.
6. Place the DBI Cells by lining up to
tabs and inserting them into the DBI
Cell Socket. Rotate 90° to lock them
into place.
7. Plug the Cable from the DBI Cells
to the connector on the rear of
the Ballast Housing.
8. Replace the Unit, rotating and
aligning the holes and posts, and
fasten the Knurled Thumb Nuts.
←
←
←

9
Maintenance/UV Lamp Indicator
Cell Disposal
Please do not throw a used PCO Cell in the garbage. The special germicidal
UVC bulb used in the unit contains a very small amount of mercury.
Be sure to dispose of them properly according to local regulations.
Your pureAir HVAC unit requires no periodic maintenance beyond the
normal replacement of the PCO Cell every year. It is recommended, for
optimum performance, that the PCO Cell be replaced annually.
The UV Lamp Operation Indicator on the face of the unit will glow when the
unit is in use. If the indicator does not glow and the unit has power, the PCO
Cell needs replacing.
UV Lamp Operation IndicatorUnit Operation Indicator

10
Changing the Cell
1. Unplug the unit’s power cord
from the outlet.
2. Remove the Thumb Nuts and unit
from the duct.
3. Remove the two (2) screws
holding the cell on the rear of
the Ballast Housing.
4. Replace the Cell and UV Lamp
and fasten the new parts with the
two (2) screws into place.
5. Replace the Unit and the
Thumb Nuts.
6. Plug the unit’s power cord into
the outlet.

11
Warranty Information
Your pureAir HVAC unit consists of three(3) separate products. The housing, which protrudes from the HVAC duct
when installed, the PCO Cell which extends into the ductwork.
Your pureAir HVAC (Product) is warranted to be free from all defects in material and workmanship in normal
household use for a period of two (2) years from date of purchase.*
Your PCO Cell, including the bulb, is warranted to be free from all defects in material and workmanship in
normal household use for a period of one (1) years from date of purchase.
The warranty is granted only to the original purchaser. The warranty is subject to the following provisions:
Any damages or malfunctions caused by negligence, abuse, or use not in accordance with the Product
Owner’s Manual are not covered by this warranty. Likewise, any defects or damages caused by unauthorized
service or the use of other than Genuine GreenTech Environmental Parts are not covered.
GreenTech Environmental will, at its option, repair or replace a defective Product or part(s) for the Product that
is/are covered by this warranty. As a matter of warranty policy, GreenTech Environmental will not refund the
customer’s purchase price.
OBTAINING WARRANTY SERVICE
To obtain warranty service you must return the defective product along with proof of purchase to the
GreenTech Environmental Authorized Service Center. All shipping costs submitted under this Warranty shall
be borne by purchaser. Unless this Warranty is expressly renewed or extended by GreenTech Environmental,
any repaired or replaced part of unit shall be warranted to the original purchaser only for the length of
the unexpired portion of the original warranty. For the location of the nearest GreenTech Environmental
Authorized Service Center or for other service information, please visit us online at:
www.GreenTechEnv.com/Support
Before any product is sent for service, the customer should contact the GreenTech Environmental Service
Center to obtain a Return Merchandise Authorization (RMA) Number. This RMA Number should be clearly
written on the box before shipping. All components/parts including the remote (if applicable), manuals,
and original packaging should be included in the return if available.
FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS
Any warranty that may be implied in connection with your purchase or use of the Product, including any
warranty of merchantability or any warranty for Fitness For A Particular Purpose is limited to the duration of this
warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations
may not apply to you.
Your relief for the breach of this warranty is limited to the relief expressly provided above. In no event shall
GreenTech Environmental be liable for any consequential or incidental damages loss of prot, or medical
expenses caused by any misuse, abuse, accident, negligence, or failure to follow instructions. The company
will not be responsible for any written or oral statements made that are inconsistent with this written warranty,
or which are misleading or inconsistent with the facts as published by the company in the literature or
specications. Some states do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you. This Warranty gives you specic legal rights, and you
may also have other rights which vary from state to state.
REGISTRATION
Please register your Product within 10 days of purchase by contacting GreenTech Environmental at:
www.GreenTechEnv.com/Warranty
Registering your new pureAir product entitles you to the most up-to-date GreenTech Environmental warranty
and promotion information.

OM REVISION: GTE-pureAir_HVAC-OwnersManual-191118
Table of contents
Other PureAir Air Cleaner manuals

PureAir
PureAir 500 User manual

PureAir
PureAir AHS-PA-20190 User manual

PureAir
PureAir 3000 User manual

PureAir
PureAir SOLO User manual

PureAir
PureAir 50C User manual

PureAir
PureAir UVM9 User manual

PureAir
PureAir Motion User manual

PureAir
PureAir KT-AIR-3500 User manual

PureAir
PureAir OMNI User manual

PureAir
PureAir PCO14-23 User manual
Popular Air Cleaner manuals by other brands

DUKART
DUKART My Air Protector Travelmap TL 30 instruction manual

ELA
ELA AP282-UV instruction manual

Shark
Shark HE600 Series owner's guide

airinspace
airinspace PLASMAIR Guardian user manual

EcoQuest
EcoQuest Fresh Air owner's manual

Airtecnics
Airtecnics Cyclohnic Installation, operation and maintenance manual