Pg. 8
Cleaning & Maintenance
To clean the lters.. Shut down the unit and unplug from the power source. Remove
the rear screws on the back of the unit. Rinse the rear lter and the HEPA lter in warm
water as needed. Do not use detergent or chemicals in your water solution. Simply dust
the PCO lter do not wash or scrub the aluminum PCO lter. Make sure lters are dry
before replacing. When replacing lters you must make sure the safety switch is pushed up
towards the front of the unit. (See Section 7 of Operations/Settings And Controls)
To clean a plate, rst turn the unit O and unplug from outlet. Then remove the 4”x4”
plate from back of unit. Pull plate rmly in the center to remove from the slot. With plate
rmly supported in the hand apply a solution of warm water and ammonia (50/50 solution
is suggested) or a strong grease cutting detergent. Scrub with a sti brush if necessary. Be
careful not to drop the plate or scrub o the silicon. Clean both the metal screen and the
ceramic tile. Rinse plate in hot water and dry completely before installing. If available you
may use a hair dryer to dry the plate. Reinstall plate, making sure it is secured and ush
with the back of the unit. Plug unit into a grounded electrical outlet, turn unit on and start
enjoying clean fresh air.
To clean needlepoint ionizer, rst turn O and unplug from outlet. Remove the fan grill
cover. The needle point ionizer will be easy to nd in front of the fan by looking for two
pieces of wire. Take a Q-tip or cotton swab dipped in alcohol and clean any dust that may
have accumulated on the needlepoints. This process may be done when plates are being
cleaned. While you have the front grill cover o the unit you may also clean the fan and
grill itself. To clean the fan simply wipe the blades with a damp cloth or vacuum. The grill
cover may also be cleaned with warm soapy water. Be careful that the fan grill cover is
completely dry before installing.
Troubleshooting
Caution: Turn o Power Switch if you want to open the back panel of the unit to
insert ozone plate or replace parts.
• Make sure plate is clean (see above).
• Unit is plugged in properly and turned on.
•Check the fuse to make sure it is installed properly and not burned out. To replace
fuse, push in and turn fuse holder to the left, remove old fuse, replace with spare. Use
1 amp fuse, 1.25 inches long.
• Wall outlet is active
•Check plate alignment making sure the ceramic plate is almost ush with back of unit.
•It is important that the Air purier be properly grounded to avoid potential shock. If
the fan is not operating or after cleaning the plate no buzzing sound is detected on the
high setting of the O3, please contact your local dealer.
If you suspect a problem with your unit check the following