IV. Main functions
The PUR Quick 6 UF water filtration system provides a complex solution in
the event of contaminated water in offices and households. The standard
set of cartridges the filter is fitted with purifies the water and removes such
contaminants as sand, rust, suspended materials, chlorine and organic
substances. It also removes a variety of bacteria and viruses and lowers
the water hardness (medium water hardness to a maximum of 14 dH°).
The hollow fibre membrane UF consists of fibres (capillaries). In the
capillaries’ walls there are small channels whose diameters are smaller
from the outside to the inside of the fibres. Larger particles of dirt are held
on the surface of the capillaries (surface filtration), the smaller particles
penetrate the inside of the channels until they reach the smallest pores
(deep filtration).
Capillary filtration is an efficient alternative to reverse osmosis
filtration. The filtration process enables the elimination of 99.8% of harmful
substances such as micro-organisms, bacteria and viruses in the water
without removing the trace elements necessary for the body. Therefore
important minerals remain in the water and the conductivity will not be
lowered!
V. Assembly Instructions
We recommend to carry out the installation by a specialist. If you are
installing the system yourself, please follow exactly the steps below:
A Preparation of installation
1. Determine the location for assembling Quick 6 (pay attention to the
ambient conditions)
2. Have the following tools ready: wrench –drilling machine –drills 12
mm –lock saw (high speed steel or marble saw) –cross and flat
screwdriver–scissors –16 mm and 14 mm wrenches –long-nose
pliers.
3. Make sure you have also ready all the necessary connection
components
4. Turn off the water supply before starting the installation.
ATTENTION: To open the tube quick connection, please press the small
locking ring inwards. Hold it down and pull out the tube.
For mounting, insert the tube into the coupling as far as possible and
secure it by pulling out the hose slightly to activate the circlip.
B. Installation des Wasserfiltersystems
1. Close the inlet valve and unscrew the metal hose. Connect one end of
the supplied 3-way sleeve to the water outlet valve. Tighten the other
end of the unscrewed metal hose with the 3-way sleeve´s nut (pict. 4).
.