PUSHCORP, INC.
AFD620 Manual
The bolt pattern on the Carriage has been designed to facilitate process equipment
installation. The Carriage has (1 ) fourteen M8x1.25 mounting holes with a depth of
0.51 inch (13 mm) to provide secure attachment points. The mounting holes are
spaced 6.5 inches (165.1 mm) across and on 1 inch (25. mm) and 2 inch (50.8mm)
centers along the length of the Carriage. (See Figure 1) The Carriage also has (2)
four 5mm dowel pin holes to facilitate alignment. (See Figure 1 for location) These
dowel pin holes are oversized to allow the pins to be glued into place using Loctite
609, or equivalent.
ARNING: DO NOT press pins into the AFD Carriage as this will likely damage
the bearing Linear Guides.
CAUTION: The Fastener Tightening Torque Specs chart in Section 6.0 should
be used to determine proper fastener length and torque for fasteners into the
Carriage. This is to prevent pull-out of the Carriage helicoil inserts.
4.2 Mounting the 620 Series
The basic configuration of the 620 Series force device allows attachment to a
stationary fixture or a robotic manipulator mounting flange. Specifying an AFD620 -1
or -2, or -3 determines which Mounting Bracket is supplied. Adapter plates or
"quick-change" attachments can be used as well for mounting. The 620 Series has
(2) two mm dowel pins pressed into the base for location and alignment of the
cover and Mounting Brackets.
4.2.1 Mounting the AFD620-1 Vertical and AFD620-2 Horizontal
The AFD620-1 and AFD620-2 are supplied with a standard Mounting Bracket with a
90 mm three hole mounting pattern, See Figure 2. All three holes should be utilized
to secure the Mounting Bracket to the robot mounting flange. If the Mounting
Bracket is supplied blank or additional holes are required, it must first be removed
from the device before drilling. Four cap screws are used to attach the Mounting
Bracket to the 620 Series. Once the Mounting Bracket is removed, mounting holes
may be placed anywhere within the crosshatched area shown in Figure 2.
PushCorp, Inc. will supply engineering support to determine the mounting hole
locations at no cost.
After drilling the required hole pattern, remove any burrs and clean any machining
residue from the Mounting Bracket. The Mounting Bracket can then be reattached.