6
SPECIFICATIONS
Important Points:
1. The installation, commissioning and maintenance of this product must be
carried out in accordance with instructions given in this Manual, and must be
conducted by designated, qualied and competent personnel.
2. Installations must comply with all Local/National Water Regulations/Bye-laws
(Scotland), Building and Plumbing Regulations.
3. Rada products are precision engineered and should give continued superior
and safe performance, provided:
- they are installed, commissioned, operated and maintained in accordance
with these recommendations.
- periodic attention is given as necessary to maintain the product in good
functional order. Recommended guidelines are given in the MAINTENANCE
section.
4. Warning! Continued use of this product in conditions outside the limits listed
in this section can severely affect the performance and reduce the effective
service life, and can present potential risk to users.
5. Disinfectants: In applications where system chemical disinfection is practised,
chlorine can be used (calculated chlorine concentration of 50 mg/l [ppm]
maximum in water, per one hour dwell time), at service interval frequency.
Such procedures must be conducted strictly in accordance with the information
supplied with the disinfectant and with all relevant Guidelines/Approved Codes
of Practice. If in any doubt as to the suitability of chemical solutions, refer to
Kohler Mira Limited, or Local Agent.
Normal Operating Conditions:
- daily usage of 1 - 6 hours.
- installation and usage environment not subject to extremes of temperature,
unauthorised tampering or wilful abuse.
Temperature Range: Designed to accept water supplied between 5oC - 65oC.
Pressure Range: Recommended minimum maintained pressure at the inlet
of tting 1.5 bar. Maximum maintained pressure at the inlet of the tting
5.0 bar (with ow regulator tted).
Spray Performance: Minimum ow rate necessary to achieve a fully formed
spray pattern is 2.0 l/min.
Installation Height: Recommended installation hight is 2 metres above the
oor surface.