RADEMACHER Troll Basic 5602 User manual

VBD 599-2 (01.21)
Item no. 3650 01 12 (ultra-white)
EN
Troll Basic 5602
Instruction manual for the electrical connection and for commissioning
Type: 5602

2
EN
i
Contents
1. These instructions..............................................................4
1.1 Application of this manual................................................................4
2. Hazard symbols ..................................................................5
2.1 Levels of danger and signal words.................................................5
2.2 Symbols and depictions used..........................................................6
3. Safety Instructions .............................................................7
3.1 Intended Use..........................................................................................8
3.2 Incorrect Use..........................................................................................8
3.3 Required Expert Knowledge of the Installer ..............................9
3.4 Glossary - Definition............................................................................9
4. Included in delivery ........................................................ 10
5. General View of the Operating Unit............................. 11
5.1 General View of the Installation Housing................................. 13
5.2 Electrical connections...................................................................... 14
5.3 Function of the buttons and LEDs............................................... 15
6. Product Description........................................................ 16
6.1 Compatible switches........................................................................ 17
6.2 Overview of Features....................................................................... 18
7. Technical Specifications................................................. 19
7.1 Factory Settings ................................................................................. 22
7.2 Conduct in the event of power failure....................................... 22
8. Important information prior to electrical
installation and mounting............................................. 23
9. Safety Instructions for the Electrical Connection ..... 24
9.1 Connecting a tubular motor ......................................................... 27
9.2 Connection Diagram with Tubular Motor ................................ 28
10. Installation after the Electrical Connection ............... 29

3
EN
Contents
i
11. Connecting a light sensor*............................................ 30
11.1 Light sensor connection when using the supplied frame . 30
11.2 Light sensor connection when using a frame
supplied by a third-party manufacturer ................................... 32
11.3 Dismantling the light sensor......................................................... 33
12. Important Information regarding the
Commissioning................................................................ 34
13. Manual Operation ........................................................... 35
14. Automatic mode.............................................................. 36
14.1 Switch all automatic functions on / off simultaneously;
Auto/Manu switchover.................................................................... 36
15. Automatic timer .............................................................. 37
15.1 Configuring an opening and closing time............................... 38
15.2 Switching the automatic timer on / off..................................... 39
16. Automatic solar function............................................... 40
16.1 Automatic solar function; configuring sensitivity ................. 42
17. Automatic dusk function ............................................... 44
17.1 Automatic dusk function; configuration of sensitivity ........ 46
18. Dimming the LEDs .......................................................... 48
19. Hardware Reset in the event of Unit Failure .............. 49
20. Erase all Settings, Software Reset ................................ 50
21. Dismounting .................................................................... 51
22. Simplified EU Declaration of Conformity.................... 52
23. Accessories ....................................................................... 52
24. Warranty Conditions....................................................... 53

4
EN
i
1. These instructions...
...describe how to install, connect and operate theTroll Basic 5602.
1.1 Application of this manual
◆Before you begin, please read this manual through completely
and follow all the safety instructions.
◆Please also read the instruction manuals of the accessories,
if available, as well as the instructions of the respective
connected appliance.
◆This manual is a component of the product.
Please store it in an easily accessible place.
◆When passing the Troll Basic 5602 on to a third party,
this manual must be passed on as well.
◆Damage resulting from non-compliance with these
instructions and safety instructions will void the guarantee.
We assume no liability for any consequential damage.
i

5
EN
i
2. Hazard symbols
The following hazard symbols are used in this instruction
manual:
Danger of fatal electric shock
Danger area / dangerous situation
2.1 Levels of danger and signal words
DANGER!
This hazard will lead to serious injury or death if not avoided.
WARNING!WARNING!
This hazard may result in serious injury or death if not avoided.
CAUTION!
This hazard may result in minor or moderate injury if not avoided.
ATTENTION!
This hazard may lead to property damage.
i

6
EN
2.2 Symbols and depictions used
Depiction Description
1. Procedures
2.
◆Itemisation
1) or a) Lists
i
further useful
information
Please read the
respective manual
Indicator light flashes red
Indicator light lights up red
Indicator light is off
i

7
EN
3. Safety Instructions
The use of defective equipment can lead to personal injury
and damage to property (electric shocks / short circuiting).
◆Never use defective or damaged equipment.
◆Check the Troll Basic beforehand for damage.
◆Consult our customer service department in the event that
you discover damage, see page 54.
Incorrect use leads to an increased risk of injury.
◆Train all personnel to use the Troll Basic safely.
◆This device may be used by children from 8 years of age
upwards as well as by persons with reduced physical,
sensory or mental capacities or with lack of experience and
knowledge if they are supervised or have been instructed
on how to use the device safely and if they understand
what dangers may resulted from this.
◆Children must not play with the device.
◆Never remove the operating unit from the installation
housing during operation.
i

8
EN
3.1 Intended Use
Only use the Troll Basic 5602 for connecting and controlling
a tubular motor for:
◆Roller Shutters
◆Awnings
Operating conditions
◆Only operate the Troll Basic 5602 in dry rooms.
◆A 230 V / 50 Hz power supply, together with a site-provided
disconnecting device (fuse), must be available at the
installation location.
◆The tubular motor must be fitted with a mechanical or
electronic end position switch.
3.2 Incorrect Use
Using the Troll Basic 5602 for any other purpose than previously
mentioned is not permissible.
Improper use can lead to serious injuries or property
damage.
◆TheTroll Basic 5602 is not suitable to be used for an electrically
safe disconnection of the connected appliances.
There is a risk to life caused through short circuiting and
electric shocks if the troll Basic 5602 is used outside or in
damp rooms.
◆Do not install and use the Troll Basic 5602 outdoors or in
damp rooms.
i
i

9
EN
3.3 Required Expert Knowledge of the Installer
The electrical connection, installation and commissioning of the
Troll Basic 5602 must only be carried out by a qualified electrician
in accordance with the instructions in this manual.
3.4 Glossary - Definition
UW
◆UW = ultra-white (device colour)
DIN 49075
◆German Standard "Cover panels for installations devices for
building into device boxes...".
i
i

10
EN
i
4. Included in delivery
Included in delivery
a) 1 x Operating unit (50 x 50 mm)
b) 1 x Frame
c) 1 x Installation housing
d) 1 x Spacer frame, see page 32
e) 1 x Instruction manual (not illustrated)
After unpacking please check and compare...
... the contents of the package with the above specified.
*) Accessories, optionally available, see page 52
Light sensor
a)
b) c)
d)
*)

11
EN
i
5. General View of the Operating Unit
1)
2) 3)
Pos. Symbol Description
1) Operating unit
2) Sun LED (red)
3) Timer LED (red)
4) Dusk LED (red)
5) Timer button
◆Switch the automatic timer on/off.
6) Sun button
◆Switch the automatic solar function
on/off.
7) Dusk button
◆Switch the automatic dusk function
on/off.
4)
5)
6) 7)
8) 9)
10) 11)
12)

12
EN
Pos. Symbol Description
8) Up button
◆Open the roller shutter or stop the current
drive; see page 35.
9) Down button
◆Close the roller shutter or stop the current
drive; see page 35.
10) SET key
◆Configuration (setting) of various
functions. *
* The functions are respectively set in
combination with the other buttons,
see table on page 15
11) AUTO/MANU key
◆Switch all automatic functions on / off
simultaneously.
12) Connection socket for the light sensor
◆Installation, see page 30
5. General View of the Operating Unit
i

13
EN
5.1 General View of the Installation Housing
13)
15)
Pos. Symbol Description
13) Installation housing
14) Plug-in coupling for the operating unit
15) Claw fasteners and screws
16) Connecting terminals
17) Type plate
i
17)
16)
14)

14
EN
18)
Pos. Symbol Description
18)
E2E1 L N
Control inputs [ E1 (s) / E2 (t) ]
230 V / 50 Hz
Connection of external push-buttons or
controllers. Parallel connection of several
devices is possible on both inputs.
E1 / E2 and the Troll Basic 5602 must be connected to
the same phase [ L], see page 25.
19)
E2E1 L N
Voltage supply [ L / N ] 230 V / 50 Hz
Connection of the supply voltage.
20)
E2E1 L N
Rotational direction [Down/Up]
Connecting cables to the tubular motor.
5.2 Electrical connections
19)
i
20)

15
EN
i
Function Button LED (red)
up / stop / down / stop /
Switch automatic timer on / off 1 sec. > /
Switch the automatic solar
function on/off 1 sec. > /
Switch automatic dusk function
on / off 1 sec. > /
Switch automatic mode on/off 1 sec. / /
/
Settings Button combinations
Accept the current time as the
opening time. + 1 sec. >
Accept the current time as the
closing time. + 1 sec. >
Adopting the current brightness
as the set limit. + 1 sec. >
Adopt the current brightness
(dusk) as the set limit. + 1 sec. >
Set the running time. + 4 sec. >
Software reset + + +
4 sec.
+ +
5.3 Function of the buttons and LEDs

16
EN
i
6. Product Description
The Troll Basic 5602 is designed for controlling roller shutters
or awnings by connecting a corresponding tubular motor.
Roller shutter control
The system enables roller shutters to be automated.
Manual Operation
It is possible to manually control the connected tubular motor
at any time by using the controls.
External manual control via the two inputs E1 and E2
The Troll Basic 5602 features two inputs E1 and E2
(230 V / 50 Hz) for connecting an external push-button or
external controller, see page 28.
Installation and electrical connection
The Troll Basic 5602 is designed as a flush-mounted device for
indoor rooms. The electrical connection is carried out by means
of the connecting terminals on the reverse side of the installation
housing.
The Troll Basic 5602 can be integrated into most commercially
available switch ranges with the help of a corresponding
intermediate frame 50 x 50 (according to DIN 49075).
Suitable switch ranges are detailed on the following page.

17
EN
i
With the provided frame, the Troll Basic 5602 can be integrated
into customary switches. Suitable switches can be found in the
table below.
Manufacturer Switch
BERKER Arsys / K1 / S1
BUSCH-JAEGER Busch-Duro 2000 Si / Reflex Si / alpha
exclusive / alpha nea / solo / impuls
GIRA Standard-System / S-Color-System /
Stainless steel / Standard 55
JUNG CD 500 / ST 550 / LS 990 / CDplus and CD,
however, with coloured rings
MERTEN M1 / Atelier / Artec / Trancent /
Antique New
PEHA Standard / Dialog / Aura
LEGRAND Creo / Tenara
VEDDER Alessa (plus)
i
It may be necessary to use an intermediate frame *
50 x 50 (according to DIN 49075), depending on the
respective switch range used.
* not included.
6.1 Compatible switches

18
EN
i
6.2 Overview of Features
◆Manual operation on site
●up (ss) / stop / down (tt) / stop
◆AUTO / MANU - switchover
◆Switch automatic timer on / off
●Separate switching time for UP (ss) and DOWN (tt)
◆Switch automatic solar function (with light sensor) on / off
◆Switch automatic dusk function (with light sensor) on / off
◆External control via the two inputs E1 / E2
◆Setting options:
●Adoption of the current time as the switching time
●Adoption of the current brightness as a new brightness
set limit for the automatic solar function
●Adoption of the current brightness (dusk) as a new
brightness set limit for the automatic darkness function
◆Dimming the LEDs
◆Delete all data, reset

19
EN
i
Mains supply [ L / N ]
Mains supply voltage: 230 V / 50 Hz
Consumption: Standby: < 0.6 W
7. Technical Specifications
Connection of the tubular motor [sand t]
Switching voltage: 230 V / 50 Hz
Maximum switching
capacity:
ohmic load, e.g. bulb
8 A µ (type 1B)
inductive loads such as:
fluorescent lamps, drives,
iron core transformers, e.g. for
extra-low voltage bulbs such as
halogen bulbs
4 A µ (type 1B)
M

20
EN
i
Connection of the tubular motor [sand t]
Maximum switching
capacity:
capacitive loads such as:
electronic transformers, AC/DC
transformer, e.g. for extra-low
voltage lamps such as halogen
lamps, LEDs, etc.
4 A µ (type 1B)
Inputs [ E1 (s) / E2 (t) ] ...
... For an external manual push-button or an additional exter-
nal control, see page 25/28.
Input voltage: 230 V / 50 Hz
Improper use can lead to serious injuries or property
damage.
◆Due to the small contact distance (µ), not suitable for
disconnecting.
◆TheTroll Basic 5602 is not suitable to be used for an electrically
safe disconnection of the connected tubular motor.
7. Technical Specifications
This manual suits for next models
1
Table of contents
Other RADEMACHER Control Unit manuals
Popular Control Unit manuals by other brands

Watts
Watts CIVIC4 Installation and operation manual

morse
morse CP-201-E1-115 Operator's manual

Grundfos
Grundfos CIM 500 Installation and operating instructions

Marmitek
Marmitek LM12AU user manual

Grundfos
Grundfos PLV Series Installation and operating instructions

GO SwissDrive
GO SwissDrive EVO Original instruction manual