D9412/D7412 User’s Guide Supplement
Page 6
33267C 3/97 © 1997 Radionics, Inc.
DOOR CONTROL ?
ENTER
DOOR CONTROL FUNCTION
CYCLE DOOR ? ENTER
UNLOCK DOOR ? ENTER
SECURE DOOR ? ENTER
NEXT
PREV
NEXT
PREV
NEXT
PREV
ESC
ESC
ESC
CYCLE 1 2 3 4 5 6 7 8
UNLOCK 1 2 3 4 5 6 7 8
SECURE 1 2 3 4 5 6 7 8
ESC
ESC
ESC
CYCLE DOOR?
(See Note 2)
NOTE 2:
# = Door is normal (available)
- = Door is not active, not in scope,
or user does not have access
level authority
C = Door is on timed door sequence
U = Strike and shunt are latched active
(held open)
X = Strike and shunt are deactivated
(secured)
IDLE TEXT
then press
NEXT until
NOTE:
Pressing ESC while within any one of the sub-functions
(CYCLE DOOR, UNLOCK DOOR,
SECURE DOOR), returns the user to the top
level display prompt for that sub-funtion.
Pressing ESC while at the top level display
prompt of any sub-funtion (CYCLE DOOR, UNLOCK
DOOR, SECURE DOOR), returns the user to the
DOOR CONTROL ? prompt in the function menu.
Press the MENU key to enter the
Function Menu (or press CMD 46
to go directly to CYCLE DOOR?)
To access the Door Control function, press
CO MMAN D 46 or press the MENU key and the
NEXT key until DOOR CONTROL? appears,
then press the ENT key. Three functions are
nested inside the Door Control function: Cycle
Door, Unlock Door, and Secure Door. The
flowchart shown below describes the process of
how to navi
ate throu
h this function.
(See Note 2)
(See Note 2)