6. Safety instructions for use
When using the chair, the following
safety instructions must be observed:
Danger of slipping!
Before using, check to be sure the seat is securely
pressed into the seat frame.
Always lock the swivel castors before using the
chair. This is to prevent the chair from rolling
away.
When sitting down into the chair, the user must
not sit on the front edge of the seat or seat
cushion. Be sure the user sits all the way back on
the seat.
Danger of tipping over!
The chair may be used when sitting, travelling and
in the inclined setting only when the armrests are
locked.
The chair may be pushed only using the push bow
(backrest).
The footrests must be swivelled away or folded up
whenever the patient sits down or gets up. The
patient must never attempt to stand on the
footrests!
The chair must not bump into door sills, jambs or
on uneven surfaces.
Use the chair only indoors on solid, even, non-
slippery surfaces.
The chair may be pushed only at a walking speed
or less (with or without the patient).
Do not lean out of the chair (when the chair is still
or in motion). If the swivel castors are swivelled
inwards, then the stability of the chair is
decreased.
Special caution must be exercised when moving
the chair when the back is inclined!
Danger of pinching!
To prevent body parts or objects from getting
pinched, never reach into the hinge area when
turning the armrests up or down. Be sure to check
that the hinge areas are unobstructed before
moving the armrests!
To prevent body parts from getting pinched, do
not reach between the seat and the frame when
pressing the seat into the seat frame.
Be sure other parts do not get jammed when
folding and unfolding the footrests.
When adjusting the headrest position, be sure no
parts of the body or objects get jammed.
There’s a risk of pinching soft flesh when pulling
out and pushing in the commode pan. To avoid
injury, the commode pan may be pulled out or
pushed in only when no one is sitting on the chair.
Danger of falling!
Sitting down, standing up and moving the patient
should be supervised by a qualified care-worker,
as to the health condition of the patient.
Before and when inclining the patient in the chair,
the patient should firmly grip the armrests.
Use of the chair by patients who do not have
complete physical control and normal movement
must not be done unsupervised.
Rolling the chair on any sloped surface may be
done only with the assistance of an attendant.
Danger of breakage!
The chair is suitable only for transporting persons.
Be sure to observe the maximum allowable
patient body weight (specified on the nameplate)!
Never expose the chair to wide temperature
variations. Observe the instructions concerning
the temperature range of use (see: 1.4).
Danger of Injury!
At surface temperatures over 40°C (104°F),
there’s a risk of injury. Therefore do not expose
the chair to any source of heat (exposure to the
sun, storing near a heater, cleaning with hot
water) just before the chair is used. Before using
the chair, allow it to cool down.
7. Product specifications
7.1 Scope of delivery
The product has been carefully inspected in the
factory for freedom of defects and for completeness.
After having received it, carefully check over the
product for possible transport damages and for
completeness.
1 PU or PS shower chair (base model)
1 headrest unit
1 User Manual
7.2. Technical specifications
We reserve the right to make technical
developments and improvements with respect to
the design shown in the User Manual.