2
Regal, Evergreen and Genteq are trademarks of Regal Beloit Corporation or one of its affiliated companies.
©2017 Regal Beloit Corporation, All Rights Reserved. MCIM17043E • Form G0038E • Printed in USA
Specifications:
Voltage: 208-240 (allowable voltage range 187-264) VAC, single-phase
input, 50-60 Hz
Horse Power: 1/5HP (replaces 1/10-1/5) 1/3HP (replaces 1/10-1/3)
Speeds: 2 operating speeds (Constant Speed)
• 1100 RPM (6-pole) replaces motors rated 1000-1100 RPM
• 850 RPM (8-pole) replaces motors rated 800-850 RPM
Rotation: CCW or CW by reversing plug (factory set to CCW)
• As viewed from lead end
Bearing: Permanently lubricated ball bearing
Ambient Rating: 60° C
Enclosure: Totally Enclosed Air Over (TEAO), NEMA 48-frame
Shaft: Single, ½” diameter, 3” length, 2.5” single flat
Mounting: Horizontal or vertical shaft-down (VSD), belly band or rear
extended clamp bolts
Leads: 54” length with ¼” fast on terminals, ground wire #10 eyelet
UL and CSA recognized component
STOCK
NO. HP RPM VOLTS MAX
CURRENT
6301 1/5 1100/850 208-240 2.8
6303 1/3 1100/850 208-240 3.5
Application Note:
This product is designed to replace induction motors (shaded pole
or PSC) in direct-drive fan propeller applications. Do not use this
motor to replace OEM ECM outdoor fan motors or belt drive mo-
tors. OEM ECM outdoor fan motors must be replaced with OEM
equivalent.
Operation Note:
Evergreen®OM motor will delay turning on approximately 5 seconds
after L1 or L2 voltage is applied to one of the speed wires, then ramp
up to speed. The Orange and Yellow speed wires dictate the on/off
command to the motor control.
Replacing the Evergreen®OM Motor:
If the motor does not operate with proper Line Voltage measured
between the White wire and the Black wire, AND between the White
wire and the Speed Selection, it has failed and will require replacement.
Before replacing the motor, please call the Contractor Hotline (1-866-
503-8566) to confirm your diagnostics if possible. The Evergreen®OM
motor is a single component replacement. The control cannot be
replaced separately from the motor. Contact the distributor where
the motor was purchased or any authorized Evergreen motor distributor
for replacement.
Safety Considerations
The following definitions are used as safety considerations on the
Evergreen®OM motor and in this manual. Please read and observe all of
these safety concerns.
Safety Symbols
WARNING! Warning indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
CAUTION: Caution indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
Installation and service of this motor should be performed only by
trained service technicians familiar with the Evergreen OM motor.
This motor should be installed in accordance with accepted practices
and installation instructions, and in compliance with all national and
local codes.
WARNING! Improper installation, adjustment, alteration, service,
maintenance, or use can cause explosion, fire, electrical shock, or other
conditions which may cause personal injury, death, or property damage.
Consult a qualified installer, service agency, or your distributor or branch
for information or assistance. The qualified installer or agency must use
the supplied or recommended parts when installing or servicing this
product.
WARNING! Always disconnect the main power from the unit being
serviced before making any wiring connections to the Evergreen OM
motor. It is also a good practice to confirm that the power is off with an
electric voltmeter.
Terms & Conditions of Sale & Limited Warranty
Sales of the products described in this Installation Manual are subject to
the “Regal Beloit Terms and Conditions of Sale”current at the time of sale.
They are accessible on RegalBeloit.com – https://www.regalbeloit.com/
Brands/ (click “Regal Terms and Conditions of Sale”).
The full Limited Warranty, including the scope and period, remedies,
exclusions and disclaimers, is described in Section 10 “Limited Warranty”
of the Regal Terms and Conditions of Sale.
The following is the “Scope and Period” (Section 10(a)(1)) portion of the
Limited Warranty applicable to the products described in this Installation
Manual:
Seller warrants that the Products shall be delivered free from defects
in material, workmanship and title and shall conform to Seller’s written
specification agreed upon by Buyer and Seller in a written and signed
agreement, if applicable, for the Products. This warranty shall expire
twenty-four (24) months from the first use of the Product or thirty (30)
months from date of shipment of the Product, whichever occurs first.
Changing Rotation
From the factory, the motor will be set up for CCW rotation, as viewed
from lead end.
The Yellow wire connected thru the 2 pin connector to the Violet wire
and the Orange wire connected thru the 2 pin connector to the Brown
wire.
Step 1: To change the rotation from CCW to CW:
Disconnect the 2 pin connector and rotate it 180° so the Yellow
wire is connected to the Brown wire thru the 2 pin connector
and the Orange wire is connected to the Violet wire thru the 2
pin connector.
Yellow
Orange
CCW (Factory)
Violet
Brown
Yellow
Orange
CW
Brown
Violet
Rotation Connector
CAUTION: Secure all wires, including the Rotation Connecton, out of
the path of the fan blade before starting the motor!