REMKO RAV 30 User manual

Edition GB – G12
REMKO RAV 30
High-performance fans for
construction and renovations
Operation Technology Spare parts

2

3
Contents
Safety notices 4
Description of the unit 4
Commissioning 5
Decommissioning 5
Care and maintenance 6
Intended use 6
Customer service and warranty 6
Environmental protection and recycling 6
Technical data 7
Spare parts list 7
These operating instructions must be read carefully
before commissioning/using the unit!
These instructions are part of the unit and must always be kept in
the direct vicinity of the site of installation or on the unit.
This operating manual is a translation of the German original.
We reserve the right to make changes; no liability for errors and misprints!

4
HIGH-PERFORMANCE FANS
Safety notices Description of the unit
NOTE
Only authorised electricians
may extend the connecting
cable,
taking into account the
rating of the unit
, cable length
and local use.
The units were subjected to ex-
tensive material, functional and
quality inspections and tests prior
to delivery.
The units can however constitute
a hazard if used improperly by
untrained persons or not for the
intended purpose.
Always observe the following
safety information:
■The locally applicable building
and other regulations must be
observed.
■The operator is responsible for
correct installation of the units,
correct electrical installation and
safe operation of the units.
■The units must always be set up
and operating in a stable man-
ner.
■The units may be set up and
operated only in an environment
not at risk of fire or explosion.
■The units must not be set up
and operated in aggressive envi-
ronments.
■Protect the environment and
yourself from
any flying parts.
■Safety components such as
protection grids must be neither
dismantled nor decommissioned.
■The units must only be operated
within the specified capacity
limits.
■The air inlets including grilles
must be kept free of dirt and
loose objects at all times.
■The air inlet and outlet must not
be closed.
■Never insert foreign objects into
the device.
■The unit must not be subjected
to a direct jet of water.
■Never allow water to enter the
unit.
■All electric cables of the units
must be protected against dam-
age e.g. by animals, etc.
■The unit musst not be transport-
ed during operation.
■People who use the unit must
be familiar with the risks arising
with the use of conveying fans.
■Use hearing protection when
in the vicinity of the unit for a
longer period of time.
The combination of a powerful
axial fan and thoroughly conceived
accessories for the connection of
air distributor hoses makes RAV 30
a particularly versatile solution for
aeration and ventilation, air circula-
tion and cold or hot air transport,
even over longer distances.
RAV 30 is also ideal for the effective
support of dehumidifiers in the dry-
ing of buildings under construction.
Due to fast air movement, the layer
of high air moisture on the material
is broken up and the evaporation
rate increases. Walls, ceilings, and
floors thus dry faster! The higher
the flow speed on the moist mate-
rial surface, the faster the drying
process takes place.
Depending on the respective envi-
ronment and temperature, the dry-
ing time can be drastically reduced
by the combination of dehumidifiers
and the RAV 30 high-performance
fan.
Through the use of additional fans,
the evaporation is accelerated,
whereby the drying process can be
reduced by up to 50%.
The unit has tube connection
adapters on both sides, enabling a
high variety of uses.
The units are equipped with a
3-speed high-performance axial
fan, operating hours counter, and
mains cable with a 230 V Schuko
safety plug.
The units comply with the basic
health and safety requirements of
the pertinent EU regulations and
are easy to operate.
When high-performance fans
are used, people must be
aware of any risks that arise.
ATTENTION
!

5
Before using for the first time
■
The correct unit setup
and as-
sembly of any accessories used
must be checked.
Switching on the device
■
Switch the unit to the desired
power level using the 3-speed
selector switch.
Commissioning
NOTE
Electrical connection of the units
must be made at a separate
supply point using a residual-
current-operated circuit-breaker
according to VDE 0100 § 55.
Decommissioning
Care and maintenance
The units are virtually mainte-
nance-free in normal operation.
To ensure trouble-free operation,
however, they should be inspected
regularly and cleaned and/or
repaired if necessary according to
the respective conditions for use.
Cleaning the units
■
The units must be disconnected
from the supply in all poles and
locked to prevent unauthorised
reconnection.
■
The protective grids for the air
inlets must be cleaned regularly
and replaced in case of dam-
age.
■
Clean all air inlets and air outlet
louvres.
■
Remove the protective grid
before cleaning the fan blade.
■
Remove heavy soiling on the
fan and fan housing with a
soap solution.
■
The units must be cleaned only
dry or with a moist cloth and a
small amount of soap solution if
necessary.
■
Under no circumstances use
high-pressure cleaners or steam
jet equipment.
■
Do not use caustic cleaning
agents or cleaning agents con-
taining solvents.
■
Avoid causing damage when
using compressed air.
■
Set the operating switch to the
“0” position.
■
Read the operating hours coun-
ter.
For extended periods of non-
use:
■
Disconnect the unit from the
mains supply.
■
Clean the unit and store it in a
dry location, free of dust and
direct sunlight.
Electrical connection
■
The 230V electrical connection
is implemented using a fitted
mains cable with safety plug.
■
Connect the mains plug with a
properly installed and secured
mains socket.
■
All cable extensions must only
be used uncoiled or unwound.
Optional dust bag # 1009535
Optional WL tube # 1009512
ATTENTION!
Always attach the tubes and
dust bag with suitable straps or
clamps.
Example 1:
Example 2:
■
When required, read the oper-
ating hours counter and note
down the reading.
The unit can be stacked for space-
saving storage.

6
HIGH-PERFORMANCE FANS
Based on their structural design
and equipment, the units are
conceived only for aeration and
ventilation, air circulation, or dust
extraction under observance of the
technical data and safety informa-
tion.
The portable unit conception per-
mits a fast change of location and
may be implemented only in the
ex-works unit design.
The units must not be set up or
operated on boggy or flooded
foundations.
Damage due to incorrect operation
or commissioning by unauthorised
personnel is excluded from the
warranty.
The units comply with the basic
health and safety requirements of
the pertinent EU regulations and
have been multiply tested for per-
fect function at the factory.
Customer service and
Warranty
The prerequisite for any warranty
claims is that the customer or its
recipient has returned the com-
pleted
"Warranty Document”
included in delivery to
REMKO GmbH & Co. KG
at the time of the sale and com-
missioning of the equipment.
The units were repeatedly tested
at the factory to ensure that they
function correctly.
If any malfunctions should oc-
cur, however, which cannot be
eliminated by trouble shooting
measures performed by the opera-
tor, please consult your dealer or
contract partner.
The manufacturer is not liable for
any damage attributed to failure
to observe the manufacturer's
instructions or applicable statu-
tory requirements or unauthorised
changes to the units.
Intended
use
Disposal of packaging
When disposing of the packag-
ing material, please think of the
environment.
Our units are carefully packed for
transport and delivered in sturdy
cardboard packaging on a wooden
pallet, if necessary.
The packaging materials are
environmentally-friendly and can
be recycled.
By reusing packaging materials,
you make a valuable contribution
towards waste reduction and the
conservation of raw materials.
Only dispose of packaging mate-
rial at the facilities provided.
Disposal of the old unit
Our unit production is subject to
constant quality controls.
Only high-quality materials are
used, the majority of which are
recyclable.
Make your contribution towards
environmental protection by
disposing of your old unit in an
environmentally-friendly manner.
Only dispose of your old unit at
an authorised recycling facility or
similar
.
NOTE
Operation for any oth-
er purpose than that de-
scribed in these operating
instructions is not permitted.
Non-observance will result in
all liability being disclaimed
and invalidate the warranty.
NOTE
Only authorised specialists
may undertake repairs and
maintenance.
Environmental
protection and
recycling
Copyright
Any copying of this document
in whole or part or use for pur-
poses other than that intended
is strictly forbidden without
the prior written permission of
REMKO GmbH & Co. KG
.
ATTENTION
!

7
Technical data
Series RAV 30
Design Axial fan
Ventilation capacity, 3-stage m3/h 3800/3400/3100
Max. pressure Pa 280
Electrical connection V/Hz 230/1~/50
Max. power consumption Watt 650
Fuse protection (on site) A 10
Max. current consumption A 3.0
Type of protection IP 44
Sound pressure level dB (A) 76
Max. conveyor temperature °C 40
Hose connection Ø mm 300
Max. hose length m 38
Dimensions - height/width/depth mm 530/380/480
EDP No: 1610630
Weight kg 15
No. Designation Ref. no.
1Protective grid for air intake with tube connection adapter 1113040
2 Fan blade 1113041
3 Electric motor 1113042
4 Fan housing 1113043
5 Control panel 1113044
6 3-speed operating switch 1113045
7 Condenser 1113046
8 Operating hour counter 1113048
Not
shown Mains cable with plug 1113049
Spare parts list
1
87
6
1
4
5
23
We reserve the right to make changes to dimensions and the design in the interest of technical advances.

Consulting
Through intensive training, we
ensure that the expert knowl-
edge of our consultants is always
up-to-date. This has given us the
reputation of being more than
just a good, reliable supplier
REMKO, a partner
who helps solve problems.
Sales
REMKO not only has an exten-
sive sales network in Germany
and abroad, but also unusually
highly qualified sales experts.
REMKO field employees are
more than just sales representa-
tives: they mainly provide our
customers with consulting serv-
ices in regard to air-conditioning
and heating technology.
Customer service
Our units operate precisely and
reliably. If a fault should occur,
REMKO Customer Service is
there to help you. Our extensive
network of experienced special-
ised dealers guarantees you a
fast and reliable service.
REMKO INTERNATIONAL
...and somewhere near you!
Take advantage of our experience and advice
REMKO GmbH & Co. KG
Klima- und Wärmetechnik
Im Seelenkamp 12 D-32791 Lage
Postfach 1827 D-32777 Lage
Telephone +49-5232-606-0
Fax +49-5232-606-260
E-mail [email protected]
Internet www.remko.de
Subject to technical changes, information supplied without liability!
Table of contents
Other REMKO Fan manuals
Popular Fan manuals by other brands

QUORUM INTERNATIONAL
QUORUM INTERNATIONAL Mykonos 72" installation instructions

Kooltronic
Kooltronic Kooltray II Series Operator's manual

Fanimation
Fanimation Edgewood TF900 Series owner's manual

Ventamatic
Ventamatic MaxxAir HVFF 20 Instruction & owner's manual

emerio
emerio FAN-107404.4 instruction manual

Bionaire
Bionaire BT014 Series Instruction leaflet