RENPHO R-D001RS User manual

2
Introduction
Thank you for choosing the RENPHO Foot and Calf Massager. Please
use this product with the utmost care and
safety in mind. To ensure
safety and avoid any accidental
damageor injury,pleasereadthis manualcarefullyanduse
the product only as indicated. Non-compliance may cause
seriousinjuries,deathand/orseverepropertydamage.
IMPORTANT SAFETY INSTRUCTIONS
Whenusinganelectricalappliance,basicprecautions should
alwaysbefollowed,includingthefollowing:
Readallinstructions
beforeusing(thisappliance).
DANGER –To reduce the risk of
electric shock:
1) Always unplug this appliance from the electrical outlet
immediately
after using and before cleaning.
WARNING –To reduce the risk of burns,fire, electric
shock,or
injurytopersons:
1)
Anapplianceshouldneverbeleftunattendedwhen
pluggedin.
Unplugfromoutletwhennotinuse,andbefore
puttingonortakingoff
parts.
2)
Donot operateundera blanket orpillow. Excessive
heating can
occur and cause fire, electric shock, or injury
topersons.
3)
Close supervision is necessary when this appliance is
used by, on, or near children, invalids, or disabled persons.
4)
Usethisapplianceonlyfor itsintended use as described
in this
manual. Do not use attachments not recommended
bythe
manufacturer.
5)
Neveroperatethis applianceif ithasadamagedcordor
plug.Ifit is

3
notworkingproperly,ifithasbeendroppedor
damaged,ordropped
intowater.Returntheappliancetoa servicecenterfor examinationand
repair.
6)
Donot carrythisappliancebysupplycordorusecord
as a handle.
7)
Keep the cord away from heated surfaces.
8)
Neveroperatetheappliancewiththeairopenings
blocked.Keeptheairopeningsfreeoflint,hair,andthe
like.
9)
Neverdroporinsertanyobjectintoanyopening.
10)
Donotuseoutdoors.
11)
Donotoperate whereaerosol(spray)productsare
beingusedorwhereoxygenis beingadministered.
12)
Todisconnect,turnallcontrolstotheoffposition,
then
remove the plug from the outlet.
WARNING:Donotstandonorintheappliance.Useonly
whileseated.
WARNING:Donotuseamassagerincloseproximityto looseclothingor
jewelry.
WARNING:Keeplonghairawayfrommassagerwhilein
use.
WARNING:Temperatures sufficiently highto causeburns
may occur regardless of the control setting. Do not use on an infant or
invalid or on a sleeping or unconscious person.
Do not use it on insensitive
skin or on a person with poor
bloodcirculation.Checktheskinin contact
withthe heatedareaoftheappliance frequentlytoreducetherisk of
blistering.
WARNING:DoNotCrush–Avoidsharpfolds.
DANGER:Never usepinsor othermetallicfastenerswith
thisappliance.
DANGER: Carefully examine thecovering before each use.
Discardtheapplianceifthecoveringshowsanysignof
deterioration, such as checking,blistering,or cracking.

4
DANGER:KeepDry–Donotoperateinawetormoist
condition.
For household use only. Do not immerse in water.
SAVETHESEINSTRUCTIONS
About the RENPHO FootandCalfMassager
1.Specification
Model: R-D001RS
Input: AC 100-240V 50/60Hz
RatedPower: 60W
Auto-off Timer: 15min/20min/30min
Product Size: L584*W395*H246mm
ProductWeight:8.2kg
2.PackageIncluded
1 X RENPHO Foot and Calf Massager
1 X
Remote Control
1 X User Manual
Note: After powering on the treadmill,
enable your mobile phone Bluetooth
setting, search for R-D001RS and
connect it.

5
3.Overview
Heat
Suitable for calf
circumference
within 19.7 inches
15 20 30
Time
Control Panel
L M H
Knead Intensity
1 2 3 4
Air Intensity
Air Mod e
Power
Detachable
foot cover
with zipper
Magnetic area
designed to place the
remote control
RemoteControl
4. Button Introduction
ButtonName
Function
Power
PowerON/OFF
Air Mode
Full feet(Default), Fore feet, Rear feet, OFF
Air Intensity
1 (Default) / 2 / 3 / 4
KneadIntensity
L(Default) / M / H / OFF
Time(Auto-off)
15min (Default) / 20min / 30min
Heat
Instep+Bottom(Default),Instep,
Bottom,OFF
Tips:Useyour thumbtopress buttonstoget bettertouch
sensitivity.

6
Using the Renpho Foot and Calf
Massager
MassagePostures
When massaging calves, it is
recommended to turn on only
the Air pressure or Kneading
function, and start from the
lowest intensity.
Massage Feet Massage Calves Massage Arms
We recommend you limit massaging to 15-30 minutes. Longer
massage time may cause mild pain.
Operation
1.
Connecttheplugtothepowersource.ThePower
indicatorflashes White accompanied bya beep sound and
the
massager enters standby mode.
2.
Press the Button to turn on the massager. Check the
defaultModeandIntensityinButtonIntroduction chart.
3.
P
ress the Buttontoswitchtheauto-offtimeamong
15,
20, or 30 minutes. The timer will re-time each time you
press
the Time Button.
4.
Press toturnON/OFFtheModefunctionorselect
Full
feet, Fore feet or Rear feet area.

7
5.
Press ButtontoadjusttheAirIntensity
among
1/2/3/4.
6.
Press the Button to adjust the Knead Intensity among
L/M/H/OFF.
7.
Press the ButtontoturnON/OFFtheheating
function
orselectFull(Bottom+Instep),InsteporBottom,
heatingarea.
Note:
A:Heating, Kneading and Airpressure function can work
independently.
B: Each press is accompanied by a beep sound and
correspondingindicator light (When off, theLEDgoesout).
C:If noneof theHeating, Kneading and Air pressure
functionisworking,theTimeandPowerbuttonindicator
lights are on, and the massager will enter thestandby
state if there is no further operation within 10 seconds.
8.
The foot massager fits up to US Men's size 14 (EU
Men's
size
48.5 ).
9.
Removablemesh: Unziptoremove andclean

8
Product Care and Maintenance
1.
Theuse of non-ratedvoltage is prohibited.
2.
Itisprohibitedfornon-professionalpersonneltorepair
the massager or replace parts.
3.
Do not use or store the appliance in wet environments or
hightemperatures.
4.
Unplug the power cord from the outlet after using.
5.
Ensure that the operation of this product does not
exceed more than 30 minutes atany given time.
6.
Ifyou feelunwell orin anyunusualdiscomfort, please
stop using the product immediately.
7.
Ifahightemperatureorfoulodorisexperiencedwhile
using the product, stop using immediately and unplug the
device.
8.
AnyIndividual whomaybe pregnantorrecently gave
birth, has a heart condition or a pacemaker, suffers from
diabetes or other sensory impairment, phlebitis and/or
thrombosis, joint dysfunction, inflammation or injuries,
weak bones, osteoporosis, a high fever, an abnormal or
curved spine, is at an increased risk of developing blood
clots, has pins/screws / artificial joints or other medical
devices implanted in his / her body, is being treated for a
medical condition or physical injury or is under a doctors
care should consult with a medical professional before
using a massaging device designed for home use.
9.
Donotusesharpobjectstohandlethe productinorder
to avoid damage.
10.
Please keep the product clean. You can use soft cotton
doth
and neutral detergent to clean it.

9
11.
The product is a temperature-protection device; it will
automatically shut-off when the temperature exceeds the
safe
limit.
Troubleshooting Guide
Common problems
Possible Cause
Solutions
The product
does not work
1.Disconnected
power
or loose plug
causing
poor
contact.
2.The power switch
is
off or time is up.
3.The
motor auto
shuts-off
due to the
device being on too
longactivating
overheating
protection.
1.Re-plug to the power
source.
2.Turn the power switch
on again.
3.Use the massager
after
the motor cools off
naturally.
Themassage
intensity Is too
high or too low
1.Your feet is
positioned at the
wrong angle.
Didn’ t choose
intensity level which
isright for you.
1.Adjust the contact
angle to get moderate
intensity.
The massager has 4
intensity levels, choose
the intensity you prefer.
We recommend low
intensity tobegin with.

No heating or
insufficient
heating
1.
The
heating
function isn’ t
turned on.
2.
The working heat
area might be
bottom, not
full/Instep.
3.
The product
structure and
working principle
limitshowfastthe
bottomcan heat up.
Therefore, the
heating-upmay
seem a bit slow,
wait a few minutes
longer.
4. The ambient
temperature or the
internal temperature
of the product is too
high, the heating
function will be
turned off because
of the over-heated
protection.
1.
Press the ” Heat”
button. The white
indicator light should
turn on.
2.
Choose the Full Heat
area to get more
sufficientheating.
3.
It takes about a few
minutes to fully heat up.
Please be patient as this
is to avoid the tempera-
ture rising too fast.
4.
Aftertheinternal
temperature drops, the
heatingfunction willbe
auto-turnedon.
The touch panel
is not working
properly
1.
Fingers are wet.
2.
Insufficienttouch
area.
1.
Dry your fingers
beforetouchingthe
button.
2.
Useyourthumbto
press buttons to get
better touch sensitivity.

FCC Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
- English:
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) This device may not cause interference,
and (2) This device must accept any interference, including interference that may cause undesired
operation of the device.
- French:
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
Table of contents
Other RENPHO Massager manuals

RENPHO
RENPHO RP-FM058R User manual

RENPHO
RENPHO EM-2016C User manual

RENPHO
RENPHO RP-EM2020W User manual

RENPHO
RENPHO SD-002 User manual

RENPHO
RENPHO R-D002RS User manual

RENPHO
RENPHO R-D200R User manual

RENPHO
RENPHO Eyeris Smart User manual

RENPHO
RENPHO RP-SNM067 User manual

RENPHO
RENPHO RF-BM066 User manual

RENPHO
RENPHO SD-002 User manual