LaserLight3 Wi-Fi Module Installation and Setup
© Rice Lake Weighing Systems ● All Rights Reserved 5
3. Perform one of the following:
• For LaserLight3 Remote Display, navigate to Setup ▼ Comm ▼ WiFi ▼ Enabled.
• For LaserLight3 Large-Display Weight Indicator, navigate to Audit
►
Setup ▼ Config ►...► Comm ▼ WiFi
▼ Enabled.
4. User arrow keys to set the Enabled parameter to On.
5. Press
. The Trigger parameter displays.
6. Press to exit the menu.
Wi-Fi Configuration
The LaserLight3 creates a Wi-Fi network (with a soft AP) that can be connected to a computer or the location’s network to
configure wireless settings. The following procedure is for setting up the Wi-Fi network using the wireless module’s built-in Web
Manager.
NOTE: The use of a web browser on a computer or handheld device is needed to access the wireless module’s built-in Web
Manager.
1. Scan for available Wi-Fi networks using a computer or wireless device and connect to the Soft AP. It might take
several attempts before the Soft AP appears on the computer or device.
NOTE: The Soft AP is only compatible with 5 GHz networks. The connecting device must be capable of using the 5 GHz
band to connect to the Soft AP. Setup ▼ Comm ▼ WiFi ▼ Enabled parameter defaults to Off and must be set to On to
enable the Soft AP.
• Soft AP Name: RLWS_XXXXXX
• Soft AP Password: PASSWORD
Figure 10. Windows Security Key Prompt
NOTE: The X’s in the name represent the last 6 digits of the Wi-Fi MAC address. The serial number on the wireless module’s
label is almost the same, other than the last digit being one number/character less than the Wi-Fi MAC address.
FOR EXAMPLE: If the module’s serial number is "0080A3E8C27A", then the SSID would be "RLWS_E8C27B". The MAC
address is a Hexadecimal value, so the letter A follows the number 9, and this continues to F before incrementing the next
most significant digit and returning to 0.
2. Once connected to the Soft AP, use a web browser and enter 192.168.0.1 as the URL address and press Enter.
NOTE: Once connected to a network, a web browser on that network can connect to the Web Manager by simply navigating
to the wireless module's IP Address (available on the Status page of the Web Manager).
3. Enter the default login credentials for the Web Manager.
• Username: admin
• Password: PASSWORD
IMPORTANT: Change default passwords to limit access and enhance security.
Figure 11. Web Manager Sign in Prompt