Manual operation
There is no display when the fire is swit-
chedoff.Pushingthe ON/OFF buttonswit-
ches the fire on and the display is activated.
Thedisplayin theupper linejumpsto„ON“
and the fire goes into start phase „ST“ at
the same time. This phase is shown by
alternating display (flashing) „ST“/“ON“.
The bottom line changes between display-
ing the heating output set as a percentage
or the remaining start time in increments
of a minute.
Heating output display: „100“ is the rated
thermal output. „0“ is the lowest heating
capacity. The heating capacity is adjusted
5% increments using the +/- key in.
Start time display: „21“ is the start time in
minutes.
Display on concluding the start phase:
Top: „ON“
Bottom: e.g. „50“ (heating capacity in %).
Automatic operation with
programming the heating time
It is recommended that the weekday pro-
gramming described in the following is car-
ried out after the start programme has
been completed.
Pushing the „ENTER“ key switches over
from „Manual Operation“ (display „ON“) to
time controlled heating. The display „TM“
(TIME) will appear in the upper line and the
current heating capacity in percent in the
bottom line. 2 on or off times can be pro-
grammed per weekday. One heating capa-
city can be programmed for the heating or
lowering times.
In general it applies: If you want to keep a
selection, then select the next display stage
using „ENTER“.
Weekday programming:
Change over into the weekday program-
ming by pushing the „MENU“ key - „MO“
(Monday) appears, pushing the „ENTER“
key willdisplay „E1“(switch ontime1) atthe
top and atthe bottom thetime in hours(0 -
23 hrs). The +, - keys can be used to alter
the time in increments of one hour. Using
„ENTER“ confirm the selection you have
made and the program will display „A1“
(switch off time 1) with the respective time.
The value can be altered as described pre-
viously. Now „E2“ appears with the time
etc. After confirming the „A2“ value using
„ENTER“, the weekday „MO“ (Monday)
appears again. Selecting „MENU“ displays
the weekday „DI“ (Tuesday). Continue with
the programming of the switch on and
switch off times for the further weekdays
as described above.
Programming the Heating Capacity,
Cleaning Cycle:
When all weekdays „MO“, „DI“, „MI“, „DO“,
„FR“, „SA“ and „SO“ have been programm-
ed, selecting „MENU“ in the display shows
„LE“ (output during switch on time) at the
top, with the display at the bottom as e.g.
„75“ (heating capacity in percent). This
valuecan be altered in 5%increments using
the +/- buttons - the new value is confir-
med using „ENTER“ and the display show
„LA“ (output when switched off) at the top
with the display at the bottom showing e.g.
„10“ (heating capacity in %). This value can
be altered in 5% increments again using the
+/-keys–the new valueis confirmed using
„ENTER“. The value for „LA“ in these hea-
ting times can either be lowered as given
above or switched off by pushing the „-“
several times and the display will show
„OFF“at thebottom (i.e. the fire isswitched
off between the heating times).
ENGLISH
15