DESIGN AND PURPOSE
The ADL-2 electronic lock consists of two
metal escutcheons integrated with handles.
The external escutcheon has a built-in
electronic reader with a keypad, which
enables electronic access control. ADL-2
grants access upon entering a PIN, reading a
proximity card or use of a mobile app. The
ADL-2 lock is designed for mounting in door
with 38 to 75mm thickness, with mortise lock
installed and with 72mm handle spacing.
Prior to installation make sure that door
cylinder is long enough. The lock is delivered
with two handle pins and two sets of bolts
with different length. In case of door with
55m or greater thickness, longer bolts should
be used.
LOCK INSTALLATION
1. Make holes in door using drilling
template.
2. Wires from internal escutcheon should be
lead through door’s hole and then
connected with wires from external
escutcheon.
3. Make sure that handle pin hole is
positioned in such way that marker (red
dot) indicates door top hinge and then
install handle pin inside the lock.
4. Install 4 x AAA batteries in the internal
escutcheon.
5. Mount escutcheon and verify the
operation of internal handle and door
cylinder, particularly if handle latch is
retracted when metal key is used.
Note: The cylinder not only offers the
possibility of mechanically locking the door,
but it also enables emergency opening of the
door in the event of a failure of the electrical
control. Availability of mechanical key should
be ensured in case of emergency opening of
the door.
Fig. 1. Proper installation of handle
mechanism
POWER SUPPLY
Lock is supplied from 4 x AAA batteries.
Assuming average 10 openings of lock per
day, alkaline batteries enable 18 months
operation of the lock. Low battery level is
signalled by red LED indicator with battery
icon (in the bottom part of keypad panel).
The indicator will signal low battery level only
when in normal mode which can be started
with [*] button.
Fig. 2. External and internal escutcheons

ADL-2 Installation Manual Rev. D.docx 2023-10-19
Page 2of 4
PROGRAMMING
Connection to mobile app
1. Download and install Roger MDM app
from Play Store or Apple Store.
Android
IOS
2. Start the app and accept permissions.
3. Press shortly the key * on ADL-2 keypad.
4. Click Register in the app to start
detection of locks.
5. Detected locks will be shown on the list in
the app (ADL-2 name and MAC
addresses). When in range then the icon
will be shown.
6. Select lock(s) from the list and then click
ADD DEVICES TO SYSTEM.
7. Long click (2s) a lock and select Device
Configuration from the menu. Default
password is empty.
8. In the top right corner select and then
Synchronize clock. Wait for clock
synchronization to complete.
9. Enter own description in the field Name.
10. Press they key * on ADL-2 keypad to
wake up the lock, then in the top right
corner click the icon to send
configuration to the lock.
Fig. 3. List of devices
in Roger MDM app
Fig. 4. List of
detected devices
after scanning
Remote PINs
1. Register/Log in at rps.roger.pl website.
2. In the top menu click ADL-2 locks and
then Add lock.
3. Note: When lock is added to particular
account at rps.roger.pl then it can be
added to another account only if removed
from the previous one.
4. Enter all lock’s parameters from the
Device Configuration section of Roger
MDM app.
5. In the top menu click General settings
and enter email address where new PINs
for the lock will be sent.
6. When PIN codes is selected then the list
of already defined PINs is displayed and
new PINs can be defined.
Local PINs
1. Long click (2s) the lock in Roger MDM
app and then select Device Configuration.
2. In the top right corner select and then
Local PINs.
3. Click and then define new PIN (4-8
digits), its name and type. When PIN(s)
are defined then back to Device
Configuration and in the top left corner
select and upload the configuration to
the lock.
4. Local PINs are valid indefinitely and they
can be removed only using Roger MDM
app.

ADL-2 Installation Manual Rev. D.docx 2023-10-19
Page 3of 4
LED INDICATORS
Signalling
Description
LED Battery
If the indicator is on after the lock wakes up, it means that its
battery level is low. In such case replace the battery in reasonable
time.
LED Status in on and red
LED Status is off when lock is in sleep mode. When [*] key is
pressed then lock enters normal working mode and LED Status is
red.
LED Status is on and green
Access is granted and it is possible to open door.
LED Status generates two red
pulses
Access is denied which can result from incorrect PIN or lock being
blocked by means of PIN Block.
LED Status is on and blue
Lock is communicating via BLE.
LED Status is on and orange
RTC failure. Clock must be programmed using Roger MDM app.
LED Status generates orange
pulses
General lock failure. Restore factory default settings and program
your lock again.
SPECIFICATION
Parameter
Value
Power supply
4 x AAA (LR03) alkaline batteries
Battery lifetime
18 months with 10 entries per day
Note: Battery lifetime is specified for Energizer Industrial LR03
alkaline batteries with 1200mAh capacity and may vary depending
on the specific type of battery and the way the lock is used.
Door thickness
38 –75mm
Handle spacing
72mm
Built-in card reader
ISO/IEC 14443A MIFARE® card reader for MFC-8 (Roger)
proximity cards
Environmental class (acc. to
EN 50131-1)
Class I, indoor general conditions, temperature: +5°C to +40°C,
relative humidity: 10 to 95% (no condensation)
IK code
IK07
IP code
IP20
Dimensions
47x280mm
Weight
~1,1kg
Certificates
CE; RoHS
ORDERING INFORMATION
Product
Description
ADL-2-L
Electronic escutcheon; access by PIN, proximity card or mobile
app; PIN codes generated remotely or programmed in lock’s
memory; four AAA battery supply; left hand version, normal or
reverse bevel

ADL-2 Installation Manual Rev. D.docx 2023-10-19
Page 4of 4
ADL-2-R
Electronic escutcheon; access by PIN, proximity card or mobile
app; PIN codes generated remotely or programmed in lock’s
memory; four AAA battery supply; right hand version, normal or
reverse bevel
MFC-8
Proximity card for ADL-2 locks
PRODUCT HISTORY
Version
Date
Description
1.0
2021/06
The first commercial version of product
2.0
2023/05
The second commercial version of product
This symbol placed on a product or packaging indicates that the product
should not be disposed of with other wastes as this may have a negative
impact on the environment and health. The user is obliged to deliver
equipment to the designated collection points of electric and electronic waste.
For detailed information on recycling, contact your local authorities, waste
disposal company or point of purchase. Separate collection and recycling of
this type of waste contributes to the protection of the natural resources and is
safe to health and the environment. Weight of the equipment is specified in
the document.
Contact:
Roger Sp. z o.o. sp. k.
82-400 Gościszewo 59
Tel.: +48 55 272 0132
Fax: +48 55 272 0133
Tech. support: +48 55 267 0126
E-mail: [email protected]
Web: www.roger.pl
Other manuals for ADL-2
2
Other Roger Lock manuals

Roger
Roger RWL-2 User manual

Roger
Roger RWL-1 series User manual

Roger
Roger SL2000B User manual

Roger
Roger SDC66 User manual

Roger
Roger RWL-2-SL User manual

Roger
Roger SL2000E User manual

Roger
Roger SL2000H User manual

Roger
Roger RWL-1-SL User manual

Roger
Roger ADL-2 User manual

Roger
Roger SL1000A User manual