Preface
R&S®OSP‑B157W8 R&S®OSP‑B157W8PLUS R&S®OSP‑B157WX
7User Manual 1178.5795.02 ─ 03
●Additional step attenuator R2 for an extended attenuation range, see Figure 4-3
Each of the 8 configurable channels in the R&S OSP-B157W8 and R&S OSP-
B157W8PLUS has the following integrated semiconductor components:
●An individually programmable attenuator
●An analog power detector for synchronous RMS power measurement with high
sampling rate and burst detection
●An A/D converter for the power measurement results
●Solid-state switches, which enable:
– Switching the (vector) signal generator output to the calibration port or to the
DUT ports
– Switching the measurement paths from DUT ports to a spectrum analyzer / test
receiver or to the power measurement
– Signal conditioning via the integrated couplers, directional couplers, attenuators
and combiners
Key features of the frequency extension module R&S OSP-B157WX
The 40 GHz module R&S OSP-B157WX is especially designed to provide RF switch-
ing for spurious measurements up to 40 GHz.
It uses coaxial RF architecture and features:
●Electromechanical RF relay switches for flexible operation of up to 8 DUT channels
●The module can forward incoming signals on each DUT channel to the connected
DUT input of the R&S OSP-B157W8 or R&S OSP-B157W8PLUS. This forwarding
is used for measurements at frequencies up to 6 GHz, which the R&S OSP-
B157W8 can handle, or up to 7.5 GHz, which the R&S OSP-B157W8PLUS can
handle.
●Alternatively, incoming signals on one single DUT channel can be switched to the
module's [Rx] port and on to a connected signal analyzer, receiver or other mea-
surement instrument. This switching state is typically used for measurements at
frequencies above 6 GHz or 7.5 GHz and up to 40 GHz, which the base modules
cannot handle. (Signals for spurious emission measurements up to 18 GHz are
also switched to the instrument connected to the extension module's [Rx] port.)
●If the R&S OSP-B157WX forwards the DUT's signals, it also switches the signal
analyzer path from its [RxOUT] port (input port) to its [Rx] port. This [Rx] port is
connected to the signal analyzer or test receiver, while the [Rx] port of the
R&S OSP-B157W8 or R&S OSP-B157W8PLUS is connected to the [RxOUT] port
(input port) of the R&S OSP-B157WX.
●Additionally, you can add the signal of a companion device to one of the DUT paths
via its internal switches and a directional coupler. The type of companion device
depends on the DUT. For example, if your DUT is a Wi-Fi transceiver, the compan-
ion device can be a wideband radiocommunication tester R&S CMW500. In this
example, it would simulate a wireless router that maintains a bidirectional connec-
tion with the transceiver.