Ross Controls DM1 Series C User manual

IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover.
F3.5www.rosscontrols.com
Online Version
Rev. 11/14/16
4
Control Reliable Double Valves
with Dynamic Monitoring
Explosion proof solenoid pilot available for basic size 4 valves, for more information consult ROSS.
DM1Series C
Air Dump / Release
Simplified Schematic
1
3
2
Dynamic Monitoring: Monitoring and air flow control functions are integrated into two identical valve
elements for CAT 4 applications. The valve exhausts downstream air if asynchronous movement of
valve elements occurs during actuation or de-actuation, resulting in a residual outlet pressure of less
than 1% of supply. If the abnormality clears itself, the valve will return to the ready-to-run state; there
is no memory of the abnormal behavior, as in the ROSS DM2® Series E and DM2® Series C products
that require an intentional reset following lockout.
Basic 3/2 Normally Closed Valve Function: Dirt tolerant, wear compensating poppet design for
quick response and high flow capacity. PTFE back-up rings on pistons to enhance valve endurance –
operates with or without inline lubrication.
Ready-to-run: If an abnormality clears itself upon the removal of electricity to both solenoids, it will be
ready-to-run again. It does not remember the abnormality and stay in a locked-out state until intentionally
reset. Therefore, cumulative abnormalities may go undetected.
Status Indicator: Includes a pressure switch with both normally open (NO) and normally closed (NC)
contacts to provide status feedback to the control system indicating whether the valve is in the “ready-
to-run” condition or has experienced abnormal function. MUST be integrated into machine controls in
order to prevent run signal until fault is cleared in valve. This indicator only reports status, it is not part
of a lockout function.
Silencers: All models include high flow, clog resistant silencers.
Mounting: Base mounted – with BSPP or NPT pipe threads. Inlet and outlet ports on both sides
provide for flexible piping (plugs for unused ports included). Captive valve-to-base mounting screws.
Basic
Size
Inlet
Port Size
CVWeight
lb (Kg)
1-2 2-3
2 1/4 1.67 2.61 5.3 (2.4)
2 3/8 2.17 2.61 5.3 (2.4)
4 1/2 3 10 5.9 (2.6)
8 3/4 4.2 13 8.4 (3.7)
8 1 4.4 13 8.4 (3.7)
# Valve and base assembly with status indicator.
DM1C N A 4 2 A 3 1
Basic Size
22
44
8
5
Automatic
Reset Type
Thread
BSPP D
NPT N
Status Indicator
Yes 1
No X
Base Port Size
2
1/4 inlet – 1/4 outlet
0
3/8 inlet – 3/8 outlet
1
41/2 inlet – 1/2 outlet 2
83/4 inlet – 3/4 outlet
1 inlet – 1 outlet
4
5
HOW TO ORDER
(Choose your options (in red) to configure your valve model number.)
Voltage*
24 volts DC A
110 volts AC, 50 Hz
120 volts AC, 50/60 Hz B
* For other voltages consult ROSS.
Connection Type
EN 175301-803 Form A*
(connector not included) Blank
M12 (connector included) 005
*See options for connectors
or wiring kits.
ISO 13849-1:2006
Category 4 PL e
applications
HSM 16008
Sicherheit seprüft
tested safety
√
Construction: Dual poppet.
Mounting Type: Base mounted.
Pilot Solenoids: According to VDE 0580. Enclosure rating according to
DIN 400 50 IP 65. Three solenoids, rated for continuous duty.
Standard Voltages/Pilot Solenoids Power Consumption
(each solenoid):
Basic Size 2 & 4:
24 volts DC; 110 volts AC, 50 Hz; 120 volts AC, 50/60 Hz.
5.8 watts nominal on AC and DC; 6.5 watts maximum on AC and DC.
Basic Size 8:
15 watts on DC; 36 VA inrush and 24.6 VA holding on AC.
Enclosure Rating: IP65, IEC 60529.
Electrical Connection: EN 175301-803 Form A, or M12.
Ambient Temperature: 15° to 122°F (-10° to 50°C).
Media Temperature: 40° to 175°F (4° to 80°C).
Flow Media: Filtered, lubricated or unlubricated (mineral oils according
to DIN 51519, viscosity classes 32-46).
Inlet Pressure: Basic Size 2: 45 to 150 psig (3.1 to 10.3 bar).
Basic Size 4, 8, 12, 30: 30 to 120 psig (2.1 to 8.3 bar).
Pressure Switch (Status Indicator) Rating: Contacts - 5 amps at 250
volts AC, or 5 amps at 30 volts DC.
Monitoring: Dynamically, cyclically, internally during each actuating and
de-actuating movement.
Mounting Orientation: Preferably horizontally (valve on top of base) or
vertically with pilot solenoids on top.
Product data for Sistema Library users, pending.
STANDARD SPECIFICATIONS (for valves on this page):
F
F3
(Basic Size 2
DGUV, CE
Certifications
pending)
REVISION LEVEL
Size 4, 8, 12, 30 A
Size 2 B
This valve is not designed for controlling clutch/brake mechanisms on mechanical power presses,
see DM2® series D for mechanical power press applications.

F3.6 © 2016, ROSS CONTROLS®. Content subject to change.Online Version
Rev. 11/14/16
Control Reliable Double Valves
with Dynamic Monitoring
DM1Series C
Valve Technical Data
Main
Solenoids
Status Indicator
0.97
(24.6)
1.32 (33.5)
1.24
(31.5)
1/2 NPT
Outlet Port
(Each Side)
1/2 NPT
Inlet Port
(Each Side)
6.33 (160.8)
12.00
(304.8)
4.34 (110.2) View X
(Base mounting hole pattern)
Valve envelope
(Based in overall hole
dimensions at left.)
0.65
(16.6)
0.27 (6.9)
(4 places)
2.74
(69.6)
4.00 (101.6)
0.16
(4.06)
4.34
(110.2)
3.68 (93.5)
12.50
(317.5)
5.41 (137.4)
1.43
(36.3)
1.92 (48.8)
1.90 (48.3)
7.48 (190)
0.34 (8.6)
(4 places)
Valve envelope
(Based in overall hole
dimensions at left.)
View X
(Base mounting hole pattern)
4.60(116.8)
2.68
(68.1)
4.28 (108.7) 0.86
(21.9)
6.23
(158.2)
0.16
(4.1)
3/4 or 1 NPT
Outlet Port
(Each Side)
3/4 or 1 NPT
Inlet Port
(Each Side)
Status
Indicator
Main
Solenoids
Basic Size 8
Basic Size 4
Schematic - Valve de-actuated
Pressure
Switch
Status
Indicator
Exh.
1
2
3
1
23
F
F3
Valve Dimensions – inches (mm)
Main
Solenoids
Status Indicator
1.19
(30.2)
0.82
(20.9)
Outlet Port
(Each Side)
Inlet Port
(Each Side)
4.79 (121.6)
9.74
(247.5
)
View X
(Base mounting hole pattern)
Valve envelope
(Based in overall
hole dimensions
at left.)
0.25
(6.4)
1.49 (37.9)
4.00
(101.6)
2.99
(75.9)
4.50 (114.3)
7.25
(184.0)
0.22 (5.6)
(4 places)
Basic Size 4
Basic Size 2

IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover.
F3.7www.rosscontrols.com
Online Version
Rev. 11/14/16
Status Indicator:
Thestatusindicatorpressure switch
will actuate when the main valve is
operating normally, and will de-ac-
tuatewhen themain valve operation
is sufficiently asynchronous or inlet
pressure is removed. This device is
notpartofthevalvelockoutfunction,
but, rather, only reports the status
of the main valve.
Asynchronous Operation: If the valve elements operate in a sufficiently asynchronous manner on ACTUATION, the valve
will shift into a position where one crossover and its related timing chambers will be exhausted, and the other crossover and its
related timing chambers will be pressurized.
In the illustration, side B is in the de-actuated position, but has no pilot air available to actuate with and has full pressure on its
upper and lower inlet poppets and return piston to hold it in place.
Inlet air flow on side B into its crossover is restricted and flows through the open upper inlet poppet on side A, through the outlet
into the exhaust port, and from the exhaust port to atmosphere. Residual pressure in the outlet is less than 1% of inlet pressure.
Once the main solenoids are de-energized, actuating pressure is removed from the top of the main pistons and then the lower
inlet poppet return spring along with inlet air pressure acting on the side A return piston will push side A back into the de-actuated
position. Inlet air pressurizes the crossovers and volume chambers. Pressure in the crossovers helps hold the upper inlet poppets
on seat. The valve will then be in the ready-to-run position. On the next attempt to actuate normally, if side B is still unable to
actuate synchronously with side A, the same sequence of events described above will occur again.
Valve actuated: Energizing the pilot solenoids
simultaneouslyapplies pressure to bothpistons,
forcingtheinternal partstomovetotheiractuated
position,whereinletairflowto outlet is open and
both exhaust poppets are closed. The outlet is
then quickly pressurized, and pressure in the
inlet, crossovers, outlet, and timing chambers
are quickly equalized. De-energizing the main
solenoids causes the valve elements to return
to the ready-to-run (de-actuated) position.
Valve de-actuated (ready-to-run): The flow of inlet
air pressure into the crossover passages from the inlet
chamber is restricted by orifices that allow air pressure to
bypass the lower inlet poppets. Flow is sufficient to quickly
pressurize the pilot supply/timing chambers on both sides
A and B. The upper inlet poppets prevent air flow from the
crossover passages into the outlet chamber. Air pressure
acting onthe inlet poppetsand return pistons securelyhold
the valve elementsin the de-actuatedposition. (Internal air
passages shown out of the valve body for clarity.)
Status indicator
in normal
ready-to-run
position
WARNING: If asynchronous operation occurs while DE-ACTUATING,
the pilot supply/timing chambers on one side will still be exhausted as
described above. However, this could be a temporary situation because
the cause of the asynchronous operation may be able to correct itself
allowing the stuck or slow acting side of the valve to eventually move
back into the de-actuated position. Once the slow or stuck side has
de-actuated, the pilot supply/timing chambers that were exhausted will
then repressurize. If an external monitoring system is only checking
the status indicator periodically this fault signal could be missed. The
machine’s safety system must be designed to ensure that this does
not cause a hazardous situation.
E
X
H
A
U
S
T
T
T
T
T
T
I
N
L
E
T
O
U
T
L
E
T
EXHAUST
OUTLET
INLET
AB
E
X
H
A
U
S
T
T
T
T
T
T
I
N
L
E
T
O
U
T
L
E
T
EXHAUST
OUTLET
INLET
AB
EXHAUST
OUTLET
INLET
AB
E
X
H
A
U
S
T
T
T
T
T
T
I
N
L
E
T
O
U
T
L
E
T
EXHAUST
OUTLET
INLET
AB
options
High-Flow, High Reduction Silencer Kits
A
B
C
Basic
Size
Kit Number*Flow
scfm
Dimensions inches (mm)
NPT threads BSPP threads AB (NPT) B (BSPP) C
2, 4 2324H77 2329H77 800 (378) 4.34 (110.2) 19.06 (484.1) 21.40 (543.6) 7.27 (184.7)
82325H77 2330H77 800 (378) 5.41 (137.4) 21.18 (538.0) 23.52 (597.4) 8.41 (213.6)
*Kits include all plumbing required for installation. Pressure Range: 125 psig (8.6 bar) maximum.
Designed to improve equipment performance and reduce the Exponentially Perceived Noise (EPNdB) in the 35–40 dB range.
F
F3
Control Reliable Double Valves
with Dynamic Monitoring
DM1Series C
Valve Operation & Options
• May be installed downstream on all double valves
• Provides a redundant means to verify the release of
downstream pressure to next obstruction
• Factory preset, 5 psi (0.3 bar) - falling
Downstream Pressure Monitoring
Redundant
Downstream
Feedback Switch
Model Number Port Threads
RC26-13 3/8 NPT
Electrical
Connectors
Electrical
Connector
Form
Electrical Connector Type Cord Length
meters (feet)
Cord
Diameter
Electrical Connector Model Number
Without
Light
Lighted Connector
24 Volts DC 120 Volts AC
EN 175301-803 Form A Prewired Connector (18 gauge) 2 (6½) 6-mm 721K77 720K77-W 720K77-Z
EN 175301-803 Form A Prewired Connector (18 gauge) 2 (6½) 10-mm 371K77 383K77-W 383K77-Z
EN 175301-803 Form A Connector for threaded conduit
(1/2 inch electrical conduit fittings) – – 723K77 724K77-W 724K77-Z
EN 175301-803 Form A Connector Only – – 937K87 936K87-W 936K87-Z
CAUTIONS: Do not use electrical connectors with surge suppressors, as this may increase valve response time when de-actuating the solenoids.
Pressure Switches
Connection Type Model
Number
Port
Threads
EN 175301-803
Form A 586A86 1/8 NPT
M12 1153A30 1/8 NPT
*
Pressure switch closes on falling pressure of 5
psig (0.34 bar).
3
1
2
Normally
Closed
Normally Open
Ground
Common
EN Connector Pinout
Pin 1
Common
Pin 3
Not Used
Pin 2
Normally
Closed
Pin 4
Normally
Open
M12 Connector Pinout

F3.8 © 2016, ROSS CONTROLS®. All Rights Reserved.
IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS, WARNINGS on the inside back cover.
Online Version
Rev. 11/14/16
Some customers prefer to monitor downstream
pressure in addition to using the DM2® or DM1Series
valve. Aconvenientwayto do this is to install a pressure
switch in the extra outlet port that is provided on the
valve. The Outlet Port Pressure Monitoring kit can be
used with one of the J-Box kits above to split one of the M12 ports on the J-Box so that a pressure switch
can be wired in as well. These kits consist of one port splitter (a Tee with three M12 connectors) and one
M12-DIN cable (1 meter).
(17)
0.7
(10)
0.4
(40) 1.6
(40)
1.6
M12x1
Female M12x1
Male
Ø0.6
GRY
PIN 2
GRN/YEL
GR
OUND
NOT
USED
BRN BLUE
GRN/YEL
BRN
PIN
1
BRN
GR
Y
GRN/YEL
GR
OUND
BLK
1
BRN
3 BLK
2
GRY
1
2
3
4
Solenoid Cables
with EN connector
Status Indicator Cable
with EN connector
Solenoid Cables
with M12 Connector
4
BLACK
3
BLUE
2
3
1
4
3
BLUE 4
BLACK
Control Reliable Double Valves
with Dynamic Monitoring
DM1Series E & C
Preassembled Wiring Kits
Outlet Port Pressure Monitoring Wiring Kit
Kit Number Length meters (feet)
2251H77 1 (3.3)
Pressure switch available separately, see valve options.
3
4
5
FEMALE
A
5
1
2
3
4
51234
1
2
MALE
FEMALE
B
1
3
2
4
5
PORT SPLITTER
These kits include 2 cables with either EN or M12 connectors
for the solenoids. All cables include cord grips.
Status Indicator kits include one cable with EN
connector and a cord grip.
Solenoid Cables
with EN connector
Status Indicator Cable
with EN connector
GRY
PIN 2
GRN/YEL
GR
OUND
NOT USED
BRN BLUE
GRN/YEL
BRN
PIN
1
BRN
GRY
GRN/YEL
GROUND
BLK
1
BRN
3 BLK
2
GRY
1
2
3
4
Status Indicator kit ordered separately.
Wiring Kits with J-Box
A J-Box is a junction box with a 10-pin MINI connector for connecting to the user’s control system
and (4) 5-pin M12 ports for connecting to the 3 solenoids and the status indicator on the DM2®
Series valve. The J-Box kits include the J-Box as described above and (4) 1-meter cables for
connecting to the valve. These cables have a connector on each end. The status indicator
cable and the (3) solenoid cables have an M12 connector on one end and a EN connector on
the other end (M12-DIN).
Standard valves come with DIN type
solenoid connections, but could be
bought with M12 type connections as
well. Therefore we also offer a kit that
provides solenoid cables with an M12
connector on each end (M12-M12). 3.9 (100)
2.90 (73.6)
dia.
0.18
[4.5]
2.0
(51)
1.41
(35.9)
1.125 - 16UN2A
1.85 (46.9)
1
2
10
3
4
5
9
8
7
6
10 Pin
Pin # Port 2
Pin # Port 3
Pin # Port 4
Pin #
Port 1
Pin #
1
2
3
4
5
6
78
9
10
(V+) 1
(V-) 2
3
4
5
6
7
8
9
10
1111
333 3
2
2
2
2
4
4
4
4
1111
2222
3333
5555
4444
J-Box Wiring
Kit Number*Connector Types Length meters (feet)
2249H77 M12 - DIN 1 (3.3)
2250H77 M12 - M12 1 (3.3)
*24 volts DC only.
Wire Colors:
Orange
Blue
White w/Black
Red w/Black
Green w/Black
PIN
#
1 +24 v
olts DC
2 Common v
olts DC
3
-
4 Solenoid
A
5 Solenoid
B
PIN #
6 -
7 Remote Reset
8 -
9 Remote Valve Fault Light
10 Remote System OK Light
Wire Colors:
Orange w/Black
Red
Green/Yellow
Black
White
1
21096
543
78
10 PIN MINI Cable These cables have a 10-pin MINI connector for connecting the J-Box kits above to the user’s control system.
Kits include one cable with connector and cord grip. Cable conductors are 18-gauge wire.
Kit Number Length meters (feet)
2253H77 3.66 (12)
2254H77 6.1 (20)
2255H77 9.1 (30)
2256H77 15.2 (50)
Kit Number Solenoid Connector Type Length meters (feet)
2243H77 EN 175301-803 Form A 5 (16.4)
2244H77 EN 175301-803 Form A 10 (32.8)
2245H77 M12 5 (16.4)
2246H77 M12 10 (32.8)
F
F3
Status
Indicator Kits
Kit Number Length meters (feet)
2247H77 5 (16.4)
2248H77 10 (32.8)

10 © 2016, ROSS CONTROLS®. Content subject to change.Online Version
Rev. 11/14/16
General Information
Thread Types by Model Prefix Letter
Pneumatic Port Prefix Threaded Electrical
Threads Letter Opening
NPT (ANSI B2.1) None NPT
ISO 228 - DIN 259 Parallel, BSPP#C*—
ISO 228 - DIN 259 Parallel, BSPP#DG
ISO 228 - JIS B0203 Tapered#JISO
SAE 1926- ISO 11926 SNPT
* Used only for filters, regulators, lubricators.
# ISO 228 threads superseds BSPP, G and JIS thread types.
Order Placement
For order placement, consult ROSS or your local ROSS distributor.
For a current list of countries and local distributors, visit ROSS’ website at www.rosscontrols.com.
Standard Specifications
The standard specifications for the products on each page of this
catalog are given on the same page or referenced. For solenoid pilot
valves, models with internal pilot supply are listed. Most models are
also available for use with external pilot supply or have a built-in pilot
supply selector valve.
Theproducts in this catalog areintendedforuse inindustrial pneumatic
systems. Mostproductsare adaptabletoother uses and conditions not
covered by the standard specifications given in this catalog. Weights
shown are approximate and are subject to change. Dimensions given,
unless otherwise noted, are envelope dimensions (not for mounting).
Consult ROSS for further information.
Port Threads
Ports of valves and bases described in this catalog have NPT (ANSI
B2.1) threads. Other thread types can be specified by putting an
appropriate prefix letter on the model or part number when ordering.
Flow Ratings
Flow ratings are expressed as CVwhere CV= 1 corresponds to a
steady state air flow of approximately 32 scfm under the following
conditions:
Inlet pressure = 100 psig (6.7 bar)
Pressure drop = 10 psi (0.69 bar)
Air temperature = 68°F (20°C)
Relative humidity = 36%
Note: Because widely differing test standards are used to measure CV
values, the figures given in this catalog should not be used to compare
ROSS valves with those of other makers. The CVratings given here
are intended only for use with performance charts published by ROSS.
The CVratings are averages for the various flow paths through the
valve and are for steady flow conditions.
Approvals and Certifications
ROSSproducts aredesigned to meet a numberofindustrial standards,
including the Canadian Standards Association (C.S.A.) guidelines.
For more information on specific product approvals, contact your local
distributor or ROSS.
Solenoids
All ROSS standard solenoids are rated for continuous duty (unless
noted otherwise) and will operate the valve within the air pressure
range specified in this catalog.
Explosion-Proof Solenoid Pilot available, for more information
consult ROSS.
Voltage & Hertz
When ordering a solenoid valve, also specify the desired solenoid
voltage and hertz.
Recommended Solenoid Voltages: 100-110 volts AC, 50 Hz;
100-120 volts AC, 60 Hz; 24 volts DC; 110 volts DC.
In addition, the following voltages are available:
200, 220 volts AC, 50 Hz
200, 240, 480 volts AC, 60 Hz
24, 48, 220 volts AC, 50 Hz
240 volts AC, 60 Hz
200, 220 volts AC, 50 Hz
200, 240 volts AC, 60 Hz.
For example: Model 2773B5001, 120 volts AC, 60 Hz.
Model W6076B2401, 220 volts AC, 50 Hz.
Please note that not all congurations are available for all models.
For additional information or help with voltage configuration, please
contact your local distributor or ROSS.
Port Identification
Valve symbols in this catalog conform to the ISO 1219-1:1991
standard of the International Organization for Standardization (ISO)
and the SAE J2051 standard of the Society of Automotive Engineers
(SAE) respectively.
Information or Technical Assistance
For additional information or application assistance concerning ROSS
products, consult ROSS or your local ROSS distributor (see contact
information on the back cover).
Voltage Types by Model Suffix Letter
Voltage Suffix Letter
120 volts AC Z
220 volts AC Y
12 volts DC H
24 volts DC W
48 volts DC M
90 volts DC K
110 volts DC P
125 volts DC C

11
www.rosscontrols.com
Online Version
Rev. 11/14/16
CAUTIONS, WARNINGS and STANDARD WARRANTY
PRE-INSTALLATION or SERVICE
1. Before servicing a valve or other pneumatic component, be
sure that all sources of energy are turned off, the entire pneumatic
system is shut off and exhausted, and all power sources are locked
out (ref: OSHA 1910.147, EN 1037).
2. All ROSS products, including service kits and parts, should
be installed and/or serviced only by persons having training and
experience with pneumatic equipment. Because any installation
can be tampered with or need servicing after installation, persons
responsible for the safety of others or the care of equipment
must check every installation on a regular basis and perform all
necessary maintenance.
3. All applicable instructions should be read and complied with
before using any fluid power system in order to prevent harm to
persons or equipment. In addition, overhauled or serviced valves
must be functionally tested prior to installation and use. If you have
any questions, call your nearest ROSS location listed on the cover
of this document.
4. Each ROSS product should be used within its specification
limits. In addition, use only ROSS parts to repair ROSS products.
WARNING: Failure to follow these directions can adversely
affect the performance of the product or result
in the potential for human injury or damage to
property.
FILTRATION and LUBRICATION
5. Dirt, scale, moisture, etc. are present in virtually every air system.
Although some valves are more tolerant of these contaminants than
others, best performance will be realized if a filter is installed to
clean the air supply, thus preventing contaminants from interfering
with the proper performance of the equipment. ROSS recommends
a filter with a 5-micron rating for normal applications.
6. All standard ROSS filters and lubricators with polycarbonate
plastic bowls are designed for compressed air applications only.
Do not fail to use the metal bowl guard, where provided, to
minimize danger from high pressure fragmentation in the event of
bowl failure. Do not expose these products to certain fluids, such
as alcohol or liquefied petroleum gas, as they can cause bowls to
rupture, creating a combustible condition, hazardous leakage, and
the potential for human injury or damage to property. Immediately
replace a crazed, cracked, or deteriorated bowl. When bowl gets
dirty, replace it or wipe it with a clean dry cloth.
7. Only use lubricants which are compatible with materials
used in the valves and other components in the system.
Normally, compatible lubricants are petroleum based oils with
oxidation inhibitors, an aniline point between 180°F (82°C) and
220°F (104°C), and an ISO 32, or lighter, viscosity. Avoid oils
with phosphate type additives which can harm polyurethane
components, potentially leading to valve failure which risks human
injury, and/or damage to property.
AVOID INTAKE/EXHAUST RESTRICTION
8. Do not restrict the air flow in the supply line. To do so could
reduce the pressure of the supply air below the minimum
requirements for the valve and thereby cause erratic action.
9. Do not restrict a valve’s exhaust port as this can adversely
affect its operation. Exhaust silencers must be resistant to clogging
and must have flow capacities at least as great as the exhaust
capacities of the valves. Contamination of the silencer can result
in reduced flow and increased back pressure.
WARNING: ROSS expressly disclaims all warranties and
responsibility for any unsatisfactory performance
or injuries caused by the use of the wrong type,
wrong size, or an inadequately maintained silencer
installed with a ROSS product.
POWER PRESSES
10. Mechanical power presses and other potentially hazardous
machinery using a pneumatically controlled clutch and brake
mechanism must use a press control double valve with a monitoring
device. A double valve without a self-contained monitoring device
should be used only in conjunction with a control system which
assures monitoring of the valve. All double valve installations
involving hazardous applications should incorporate a monitoring
system which inhibits further operation of the valve and machine in
the event of a failure within the valve mechanism.
ENERGY ISOLATION/EMERGENCY STOP
11. Per specifications and regulations, ROSS L-O-X® and L-O-X®
with EEZ-ON® operation products are defined as energy isolation
devices, NOT AS EMERGENCY STOP DEVICES.
All products sold by ROSS CONTROLS are warranted for a one-year period
[withthe exceptionofallFilters,RegulatorsandLubricators (“FRLs”) whichare
warranted for a period of seven years] from the date of purchase to be free of
defects in material and workmanship. ROSS’obligation under this warranty is
limited to repair or replacement of the product or refund of the purchase price paid solely at the discretion of ROSS and provided
such product is returned to ROSS freight prepaid and upon examination by ROSS is found to be defective.This warranty becomes
void in the event that product has been subject to misuse, misapplication, improper maintenance, modification or tampering.
THE WARRANTY EXPRESSED ABOVE IS IN LIEU OF AND EXCLUSIVE OF ALL OTHER WARRANTIES AND ROSS EXPRESSLY
DISCLAIMS ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED WITH RESPECT TO MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. ROSS MAKES NO WARRANTY WITH RESPECT TO ITS PRODUCTS MEETING THE PROVISIONS
OF ANY GOVERNMENTAL OCCUPATIONAL SAFETY AND/OR HEALTH LAWS OR REGULATIONS.IN NO EVENT IS ROSS LIABLETO
PURCHASER, USER, THEIR EMPLOYEES OR OTHERS FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES WHICH MAY RESULT
FROM A BREACH OF THE WARRANTY DESCRIBED ABOVE OR THE USE OR MISUSE OF THE PRODUCTS. NO STATEMENT OF
ANY REPRESENTATIVE OR EMPLOYEE OF ROSS MAY EXTEND THE LIABILITY OF ROSS AS SET FORTH HEREIN.
STANDARD WARRANTY
Table of contents
Other Ross Controls Control Unit manuals

Ross Controls
Ross Controls M DM2 C Series User manual

Ross Controls
Ross Controls CrossCheck CC4 Series Quick setup guide

Ross Controls
Ross Controls DM2C Series User manual

Ross Controls
Ross Controls SAE Valves 80 Series User manual

Ross Controls
Ross Controls Miniature Valves W14 Series User manual

Ross Controls
Ross Controls Automatic Valve A04 Series Operating instructions

Ross Controls
Ross Controls DM2 C Series User manual