Sony HDCU2000 User manual

OPERATION MANUAL [English]
1st Edition (Revised 3)
HD CAMERA CONTROL UNIT
HDCU2000
HDCU2500
3G/HD SDI OUTPUT EXPANSION UNIT
HKCU2007
SD ENCODER UNIT
HKCU1001
MULTI INTERFACE UNIT
HKCU1003

2Table of Contents
Table of Contents
Overview..................................................................... 3
System Configuration ............................................... 5
Basic System Components ..............................................5
System Operation Example .............................................6
Locations and Functions of Parts............................ 7
HDCU2000 Front Panel ...................................................7
HDCU2000 Rear Panel....................................................9
HDCU2500 Front Panel .................................................12
HDCU2500 Rear Panel..................................................14
Internal Switches............................................................16
HKCU2007 3G/HD SDI Output Expansion Unit
(optional).....................................................................16
HKCU1001 SD Encoder Unit (optional) .........................16
HKCU1003 Multi Interface Unit (optional) ......................17
Connections and Settings ...................................... 19
Fiber Transmission System of Dual Link Format ...........19
COAXIAL Connection System .......................................21
Dual-Camera System.....................................................22
Sub-Camera System......................................................23
Status Display .......................................................... 24
Displaying the Status Screen .........................................24
Status Display Screen....................................................24
Setup Menu .............................................................. 29
Changing Menu Item Settings........................................29
Menu Tree......................................................................31
Menu List........................................................................34
Appendix .................................................................. 48
Notes on Use .................................................................48
Error Messages..............................................................48
Specifications .......................................................... 49
HDCU2000.....................................................................49
HDCU2500.....................................................................50
HKCU2007 (optional) .....................................................52
HKCU1001 (optional) .....................................................52
HKCU1003 (optional) .....................................................52

3
Overview
Overview
The HDCU2000/2500 Camera Control Unit is connected to a
Sony HD-series high-definition video camera. It carries out
signal processing and provides an interface for external
equipment.
This unit features standard 3G optical transmission, and when
used with an HDC2000/2500 series camera, can standard
slow motion play via 2× recording speed, a 1080/59.94P, 50P-
recording subcamera system and more.
This unit may be combined with an MSU-1000 series Master
Setup Unit (optional) or an RCP-1000 series Remote Control
Panel (optional) to form a camera control system. Further, a
system capable of controlling multiple video cameras can be
configured by adding a CNU-700 Camera Command Network
Unit.
The HDCU2000/2500 has the following major features.
Front panel for increased usefulness
The HDCU2000/2500 features a design that places menu
operation switches and status LEDs related to optical
transmission, etc., on the front panel. These were moved from
under the cover of the HDCU1000/1500’s front panel,
providing even greater convenience.
Multiple video inputs and outputs
The HDCU2000/2500 features the following standard-feature
signal input/output ports.
HDCU2000
• Eight SDI outputs (Four 3G/HD switchable outputs, four HD/
SD switchable outputs)
• Four 3G/HD/SD-SDI return inputs
• Four SD analog return inputs
• Two teleprompter inputs
• One HD TRUNK output
• One HD prompter input
HDCU2500
• Seven SDI outputs (Three 3G/HD switchable outputs, four
HD/SD switchable outputs)
• Three 3G-SDI/HD-SDI/SD-SDI/SD analog return inputs
• One teleprompter input
• One HD TRUNK output
• One HD prompter input
In addition, a variety of input/output interfaces are offered via
optional installable boards.
HKCU2007 3G/HD SDI Output Expansion Unit
This provides four 3G-SDI or HD-SDI outputs.
With multiple boards of this type installed, the HDCU2000/
2500 outputs up to 16 (HDCU2000) or seven (HDCU2500)
3G-SDI/HD-SDI signals.
HKCU1001 SD Encoder Unit
Installing this board makes it possible to output SD analog
composite signals (NTSC/PAL), SD picture monitor signals
and SD waveform monitor signals.
HKCU1003 Multi Interface Unit
This board consists of 3 types of VDA boards, and makes the
following input/output signals possible:
• Frame reference input and output to lock 2-3 pull-down
sequence
• SD analog component signal (RGB or Y/R-Y/B-Y) or SD
analog composite signal output
• SD analog composite signal (NTSC/PAL) output, SD picture
monitor signal output, SD waveform monitor signal output
External reference signals
The HDCU2000/2500 can be locked to an external reference
signal. Either an HD tri-level sync signal or an SD sync (black
burst) signal may be used as the reference signal.
Built-in down converter
When the system is operating at a 59.94/50 Hz field
frequency, HD signals can be converted to SD component SDI
signals using the down converter. The output signal aspect
ratio may be set to 4:3 edge crop, 16:9 squeeze, or letter box.
The down converter has image enhancement, gamma control,
and matrix ON/OFF features, and can be controlled externally.
Built-in simplified up converter
The HDCU2000/2500 has a simplified up converter to allow
monitoring of SD signal return video using an HD viewfinder.
The aspect ratio of the return video signal may be set to 4:3
edge crop, 16:9 squeeze, or letter box.
3G Digital Optical Transfer
The HDCU2000/2500 may be connected to a camera using an
optical fiber cable (two single-mode optical fiber lines, two
power lines and two control lines) for the transmission of digital
video, audio, and control signals. By connecting together
optical fiber cables, signals may be transmitted up to a
maximum of 4,000 meters (13,100 feet) (HDCU2000)/2,000
meters (6,600 feet) (HDCU2500). The maximum length of the
cable supplying power varies with the camera system
configuration and with the type of optical fiber cable.
The HDCU2000/2500 supports standard 3G digital optical
transfer, and when used with an HDC2000/2500 series
camera, can support standard slow motion play via 2×
recording speed, 1080/59.94P, 50P recording and more via
just one optical cable.
The HDCU2000/2500 can also be connected to the HDC1000/
1500 series cameras.
Network TRUNK function
The HDCU2000/2500 can transmit data at up to 1 gigabit
using the network TRUNK function (via the LAN port).
Network-controllable camera peripheral devices connected to
the HDC2000/2500 series camera can communicate with the
HDCU2000/2500-connected network controller, as well as
utilize IP network cameras as sub-cameras. This function

4Overview
allows for current and future compatibility with a multitude of
applied system configurations.
HD TRUNK function
The new HD TRUNK function uses 3G optical transmission.
HD-SDI-equivalent digital data separate from an HD-SDI
video signal can be sent from an HDC2000/2500 series
camera to the HDCU2000/2500.
Available only when set to single link format.
HD prompter function
The new HD prompter function uses 3G optical transmission.
HD-SDI-equivalent digital data separate from a return video
signal can be sent from the HDCU2000/2500 to an HDC2000/
2500 series camera.
Safety-oriented power supply
The HDCU2000/2500 is designed for safety. When the power
is turned on, a low voltage is supplied at first. Only after it has
been verified that an appropriate camera is attached, the
normal 240 V AC (HDCU2000) or 180 V DC (HDCU2500)
power supply is activated. The power is not supplied unless a
camera is connected via an optoelectric cable.
Also, the HDCU2000/2500 is equipped with an alarm indicator
to warn of open or short circuits in the cable.
Wide range of audio functions
This unit has connectors for two-channel analog audio
outputs, a digital audio output (only for the HDCU2000), and a
program audio input. Further, the HDCU2000/2500 can use an
intercom system with two independent channels, and supports
four-wire and RTS/Clear-Com intercom systems.
For information on support for RTS/Clear-Com systems,
contact a Sony service or sales representative.
Remote control
The level and phases of this unit’s output signals can be
controlled remotely by an MSU-1000 series Master Setup
Unit.
Microphone volume control
The camera’s microphone volume can be controlled via the
MIC REMOTE connector, MSU, or RCP.
Character monitor signal output
The results of the HDCU2000/2500 self-diagnosis and setup
menu can be obtained with a text display by character signal
output.
Rack mountable
This unit may be installed in a standard EIA 19-inch rack (three
units high). (The HDCU2500 needs the RMM-301 Rack Mount
Adaptor (optional).)
Plug-in unit configuration
Internal printed circuit boards are designed for easy plug-in
and removal, which makes it easy to inspect and maintain the
unit.

5
System Configuration
System Configuration
Basic System Components
Camera
HDC2500 HD Color Video
Camera
+
HDVF-20A/200/C30WR/
C35W HD Electronic
Viewfinder
Optical fiber cable
Program audio
MSU-1000 series Master Setup Unit
Camera Control Unit
Intercom system
HDCU2000
HD Camera Control Unit
HDCU2500
HD Camera Control Unit
RCP-1000 series
Remote Control Panel
or
LAN cable Hub
LAN cable
Camera
HDC2500 HD Color Video
Camera
+
HDVF-20A/200/C30WR/
C35W HD Electronic
Viewfinder
Optical fiber cable
Camera Control Unit
HDCU2000
HD Camera Control Unit
HDCU2500
HD Camera Control Unit
or

6System Configuration
System Operation Example
HDC2500
HDC2500
MSU-1000 series
RCP-1000 series
HDCU2000
HD-SDI
HD-SDI
HDCU2500
or
HDCU2000
HDCU2500
or
Image monitor
Video monitor
LCD monitor
LAN cable
LAN cable
Hub
CCA-5 cable
CCA-5 cable

7
Locations and Functions of Parts
Locations and Functions of Parts
HDCU2000 Front Panel
aRed tally indicator
Lights in red when this unit receives a red tally signal. When
the CALL button on the MSU-1000 series Master Setup Unit,
RCP-1000 series Remote Control Panel, etc., is pressed, this
indicator will go out if previously lit, and light up if previously
off. You can attach the supplied number plate here.
bYellow tally indicator
Lights in yellow when this unit receives a yellow tally signal.
cGreen tally indicator
Lights in green when this unit receives a green tally signal.
dCCU number display
The camera number set via the CCU menu is displayed.
eINTERCOM audio input/output and control block
• MIC/PGM (microphone/program) switch
ON: Turns the headset microphone on.
OFF: Turns the headset microphone off.
PGM: Selects program audio output. In this mode, the
INTERCOM knob adjusts the headset program audio
level.
• INTERCOM (intercom select) switch
Selects the intercom signal input/output connection source for
the INTERCOM connector on the front panel.
PROD: Connects the producer line.
PRIV: Blocks the connection to the producer line or engineer
line, allowing private intercom talk between the CCU and
the camera.
ENG: Connects the engineer line.
• PRIV (Private) indicator
Lights when the intercom is in private mode.
• INTERCOM (intercom adjustment) knob
Adjusts the receiver audio level of the intercom.
• INTERCOM connector (XLR 5-pin)
1 234
qsqa09
8765
qd qf qg
MIC/PGM (microphone/program) switch
INTERCOM (intercom select) switch
INTERCOM (intercom adjustment) knob
INTERCOM connector

8Locations and Functions of Parts
Connects the intercom headset.
To use a headset with a plug other than an XLR 5-pin plug,
consult a Sony service or sales representative.
fOptical signal reception status indicator
When the two lamps on the right (green) are lighted:
Reception status is excellent.
When the second lamp from the right (green) is lighted:
Reception status is good.
When the second lamp from the left (yellow) is lighted:
Reception status is low.
When the lamp on the left (red) is lighted: Reception status
is at the lowest level.
gStatus display indicator
REF IN (Green): REFERENCE is being input.
UNLOCK (Red): The input REFERENCE is not locked.
COM ERROR (Red): There is a communication failure with
the camera or other external control equipment (such as
the RCP-1000 series Remote Control Panel).
FAN STOP (Red): The power fan is stopped.
hMENU control block
• DISP/MENU (display/menu) lever and indicator
Selects the status display or setup menu display. In setup
menu mode, the indicator turns on.
• CANCEL/ENTER lever
In setup menu mode, used to cancel and enter settings.
• CONTROL knob (rotary encoder)
In status screen mode, used to change the displayed page. In
setup menu mode, used to move the cursor on a page and to
change menu settings.
Pressing the CONTROL knob performs the same function as
setting the CANCEL/ENTER lever to the ENTER position.
iCABLE ALARM indicators
SHORT (red): Lights in red when the power supply cord of an
optical fiber cable is short to external, or two power
supply cords are short. Power isn’t input to the camera
when this indicator lights.
OPEN (red): Lights in red when a camera isn’t connected to
the CAMERA connector on the rear panel of this unit via
an optical fiber cable. Flashes when the connection
status of an optical fiber cable is bad.
jMAIN POWER switch and indicator
Turns the entire camera system on and off, including this unit,
the video camera, and the RCP-1000 series Remote Control
Panel connected to the REMOTE connector of this unit.
Press the “?” side to turn the camera system on, and the “a”
side to turn it off. The indicator lights when the power switch is
turned on.
kCAMERA POWER switch and indicator
Turns the video camera on and off when the MAIN POWER
switch is turned on. Press the top side to turn on the video
camera and the bottom side to turn it off.
When the CAM PW button of the remote control panel
connected to this unit is set to off, this switch alone cannot be
used to turn on the video camera.
lCall button
When pressed, this outputs a call signal to the camera and
external control device (the RCP-1000 series, etc.) that are
connected to this unit. Use this when you want to call and
speak with the camera operator or external control device
operator via intercom.
mAssignable button
You can set a function for this button via the CCU menu.
nNetwork indicator
Displays the network system connection status.
On: When CNS SETTING in the NETWORK SETTING menu
is set to either BRIDGE or MCS, this indicates that
external control equipment (MSU-1000/1500 Master
Setup Unit, RCP-1000-series Remote Control Panel, or
other device) is connected.
Flashing: When CNS SETTING in the NETWORK SETTING
menu is set to either BRIDGE or MCS, this indicates a
connection problem with the external control equipment
(MSU-1000/1500 Master Setup Unit, RCP-1000-series
Remote Control Panel, or other device).
Off: When CNS SETTING in the NETWORK SETTING menu
is set to either BRIDGE or MCS, this indicates that a LAN
cable is not connected or that the network system
connection parameters have not been set.
When the CNS SETTING in the NETWORK SETTING
menu is set to LEGACY, this remains turned off.
oMenu lock switch
This locks out operation of the front panel menu operation
area.
DISP/MENU (display/menu) lever and indicator
CANCEL/ENTER lever
CONTROL knob

9
Locations and Functions of Parts
HDCU2000 Rear Panel
aExpansion slots
For installation of an optional HKCU2007 3G/HD SDI Output
Expansion Unit, HKCU1001 SD Encoder Unit, or HKCU1003
Multi Interface Unit.
For details on installation, contact a Sony service or sales
representative.
bHD/SD SDI OUTPUT (SDI output connectors) area
(BNC-type)
The signal from the video camera may be output as two HD-
SDI signals or two SD-SDI signals. The signals output from the
OUTPUT3 and OUTPUT4 connectors can be superimposed
character and marker signals.
Signals of the same format are output from the SDI 1 and SDI
2 connectors; similarly, signals of another format can be
output from the SDI 3 and SDI 4 connectors.
For details on settings, contact a Sony service or sales
representative.
c3G/HD SDI OUTPUT (SDI output connectors) area
(BNC-type)
The signal from the video camera may be output as two 3G-
SDI signals or two HD-SDI signals. The signals output from
the OUTPUT3 and OUTPUT4 connectors can be
superimposed character and marker signals.
Signals of the same format are output from the SDI 1 and SDI
2 connectors; similarly, signals of another format can be
output from the SDI 3 and SDI 4 connectors.
For details on settings, contact a Sony service or sales
representative.
dHD TRUNK OUT connector (BNC-type)
When an HD TRUNK function-compatible camera is
connected to the CAMERA connector, the HD-SDI signal input
to the camera’s HD TRUNK IN connector is output from the
HD TRUNK OUT connector.
eHD PROMPTER IN connector (BNC-type)
When an HD prompter function-compatible camera is
connected to the CAMERA connector, the HD-SDI signal input
to the HD PROMPTER IN connector is output from the
camera’s SDI connector.
Notes
• Input an HD-SDI signal with a frequency synchronized to the
camera control unit.
• The NETWORK TRUNK function and either the HD TRUNK/
HD PROMPTER function cannot be used at the same time.
fRETURN INPUT area
1SDI 1 to 4 (3G/HD/SD-SDI return video 1/2/3/4
input) connectors (BNC-type)
Four different 3G/HD/SD-SDI return video input signals may
be received independently.
The selection of RET 1, 2, 3, or 4 is made by the return switch
of the video camera.
The type of input signal on RET 1, 2, 3, and 4 may be set
individually using the setup menu, or using the MSU-1000
series Master Setup Unit. The aspect ratio can also be
selected for an SD signal.
For details on the setup menu, contact a Sony service or sales
representative.
Refer also to the Master Setup Unit manual.
2VBS 1 to 4 (VBS return video 1/2/3/4 input)
connectors (BNC-type)
Four different VBS return video input signals may be received
independently.
The selection of RET 1, 2, 3, or 4 is made by the return switch
of the video camera.
The type of input signal on RET 1, 2, 3, and 4 may be set
individually using the setup menu, or using the MSU-1000
series Master Setup Unit.
An aspect ratio may also be selected for SD signals.
7
qk
89246 013 qa
qs qd qjqhqgqf
5
ql w; wa ws

10 Locations and Functions of Parts
For details on setup menu operations, contact a Sony service
or sales representative.
Refer also to the Master Setup Unit manual.
gNETWORK TRUNK connector (RJ-45 8-pin)
Used for connecting the NETWORK TRUNK connector of the
device connected to the camera with the network connection
device.
h(LAN) connector (RJ-45 8-pin)
For LAN connection. Connect a LAN HUB (10BASE-T/
100BASE-TX), using a LAN cable (shielded type of category 5
or more).
iINPUT area
1PROMPTER 1, 2 (tele-prompter input) connectors
(BNC-type)
Input a teleprompter signal to either of the two connectors. The
input signal is output from the other connector as is (loop-
through output). If loop-through output is not used, terminate
the unused connector at 75 ohms. If the signal used is a 1.0
Vp-p, 75-ohm signal, it may be output from the PROMPTER
OUT connector of the video camera with a frequency
bandwidth of 5 MHz, regardless of signal format.
2REFERENCE connectors (BNC-type)
Input an HD tri-level reference sync signal or SD reference
sync signal (black burst signal, or black burst signal with 10
Field ID) to either of the two connectors.
The input signal is output from the other connector as is (loop-
through output). If loop-through output is not used, terminate
the unused connector at 75 ohms.
The type of reference signal is selected using the setup menu,
or using the MSU-1000 series Master Setup Unit.
For details on the setup menu, contact a Sony service or sales
representative.
Note
To use the VBS signal of the HKCU1001 SD Encoder Unit or
the HKCU1003 Multi Interface Unit (when SC phase lock is
required), use an SD reference sync signal (black burst
signal).
When black burst signal with 10 Field ID is input, REF 10F BB
of OTHERS (C23) must be set to ON.
jOUTPUT area
1SYNC (sync signal output) connector (BNC-type)
Used for output of SD composite sync signal or an HD tri-level
sync signal from the internal sync signal generator. (Factory
setting: SD composite sync)
For details on signal selection, contact a Sony service or sales
representative.
2CHARACTER (character output) connector
(BNC-type)
Outputs the self-diagnostic results or the setup menu as an SD
monochrome analog video signal.
3AES/EBU connector (BNC-type)
Outputs an AES/EBU format digital audio signal input to a
video camera.
kCAMERA connector (optical fiber connector)
Used to connect a video camera, using an optical fiber cable.
All video camera signals, including power supply, control,
video, and audio, are sent and received over one optical fiber
cable.
Note
Dust on the connection surface of the optical fiber cable may
result in transmission errors. When not connected, always
cover the end of the connector with the supplied cap.
lINTERCOM/TALLY/PGM (intercom/tally/program
audio) connector (D-sub 25-pin)
Used for input and output of intercom, tally, and program audio
signals. Connect to the intercom/tally/program audio
connector of the intercom system.
Flag function: 10-pin is assigned for the output pin of the Flag
function.
mMIC REMOTE (microphone remote) connector (D-sub
15-pin)
Using this connector, the video camera’s microphone input
level may be set by external equipment such as an audio
mixer, in five level (–60, –50, –40, –30, and –20 dB).
When shooting, set the volume to a level appropriate for the
audio conditions.
This connector also outputs red, green and yellow tally
signals.
The microphone input level may also be set using the setup
menu or an RCP. For details on the setup menu, contact a
Sony service or sales representative.
nWF REMOTE (waveform monitor remote) connector
(D-sub 15-pin)
Used to attach to the appropriate connector on a recall-type
waveform monitor when operating the waveform monitor
display using an MSU-1000 series Master Setup Unit or an
RCP-1000 series Remote Control Panel. On the recall-type
waveform monitor, set/preset the display mode to waveform
monitor, and then select (recall) that mode externally.
For details on these operations, refer to the Master Setup Unit
or Remote Control Panel manuals.
oTRUNK LINE connector (D-sub 9-pin, RS-232C
standard)
Used to connect to the CCU connector on a video camera via
an RS-232C interface. Used mainly for communication with
equipment on the camera side.
Communication with up to two channels is available.
pRCP/CNU connector (round 8-pin)
Used to connect to an MSU-1000 series Master Setup Unit,
CNU-700 Camera Command Network Unit, or RCP-1000
series Remote Control Panel via a CCA-5 Connection Cable.
Control signals are sent and received via this connector.
When using an RCP-1000 series unit, power is also supplied.
qI/O PORT connector (D-sub 15-pin)
Used for remote control using an external control device.

11
Locations and Functions of Parts
Note
Use of a D-sub case wider than 42 mm can cause interference
at connectors 2, 4, 5.
It is recommended that you use a JAE-made DA-C1-J10.
rAUX REMOTE connector (round 8-pin)
This is used to connect a sub-camera RCP for operating a
sub-camera.
sTRUNK A connector (round 12-pin)
Used to connect to the CCU connector on a video camera via
an RS-232C or RS-422A interface.
Communication with up to two channels is available.
tAUDIO OUT CH1, CH2 (audio output 1, 2) connectors
(XLR 3-pin)
Used for output of the audio signal to the AUDIO IN
connectors of the video camera.
uSPARE connector (BNC-type)
Reserved for future use.
vAC IN (AC power input) connector
Use the specified AC power cord to connect to an AC power
supply. The AC power cord can be secured to this unit, using
the plug holder (optional).

12 Locations and Functions of Parts
HDCU2500 Front Panel
aRed tally indicator
Lights in red when this unit receives a red tally signal. When
the CALL button on the MSU-1000 series Master Setup Unit,
RCP-1000 series Remote Control Panel, etc., is pressed, this
indicator will go out if previously lit, and light up if previously
off. You can attach the supplied number plate here.
bYellow tally indicator
Lights in yellow when this unit receives a yellow tally signal.
cGreen tally indicator
Lights in green when this unit receives a green tally signal.
dCCU number display
The camera number set via the CCU menu is displayed.
eOptical signal reception status indicator
This indicates the camera and CCU’s optical signal reception
status when performing optical transmissions.
When the two lamps on the right (green) are lighted:
Reception status is excellent.
When the second lamp from the right (green) is lighted:
Reception status is good.
When the second lamp from the left (yellow) is lighted:
Reception status is low.
When the lamp on the left (red) is lighted: Reception status
is at the lowest level.
fMENU control block
• DISP/MENU (display/menu) lever and indicator
Selects the status display or setup menu display. In setup
menu mode, the indicator turns on.
• CANCEL/ENTER lever
In setup menu mode, used to cancel and enter settings.
• CONTROL knob (rotary encoder)
In status screen mode, used to change the displayed page. In
setup menu mode, used to move the cursor on a page and to
change menu settings. Pressing the CONTROL knob
8
9
qa
24
7
qs
13
qd qf
65
0
DISP/MENU (display/menu) lever and indicator
CANCEL/ENTER lever
CONTROL knob

13
Locations and Functions of Parts
performs the same function as setting the CANCEL/ENTER
lever to the ENTER position.
gCABLE ALARM indicators
OPEN (red): Lights in red when a camera isn’t connected to
the CAMERA connector on the rear panel of this unit via
an optical fiber cable. Flashes when the connection
status of an optical fiber cable is bad.
SHORT (red): Lights in red when the power supply cord of an
optical fiber cable is short to external, or two power
supply cords are short. Power isn’t input to the camera
when this indicator lights.
hPOWER switch and indicators
Turns the entire system on and off, including this unit, the
video camera, and the RCP-1000 series Remote Control
Panel connected to the REMOTE connector of this unit. The
MAIN indicator and the CAM indicator light when the power
switch is turned on. Pressing the CAM PW button of the
master setup unit and the remote control panel turns off the
video camera only, and only the CAM indicator turns off.
Note
In order for the power supply to supply the unit with the
necessary power to start up, energy is consumed even when
this switch is set to OFF.
iINTERCOM audio input/output and control block
• MIC/PGM (microphone/program) switch
ON: Turns the headset microphone on.
OFF: Turns the headset microphone off.
PGM: Selects program audio output. In this mode, the
INTERCOM knob adjusts the headset program audio
level.
• INTERCOM (intercom select) switch
Selects the intercom signal input/output connection source for
the INTERCOM connector on the front panel.
PROD: Connects the producer line.
PRIV: Blocks the connection to the producer line or engineer
line, allowing private intercom talk between the CCU and
the camera.
ENG: Connects the engineer line.
• PRIV (Private) indicator
Lights when the intercom is in private mode.
• INTERCOM (intercom adjustment) knob
Adjusts the receiver audio level of the intercom.
• INTERCOM connector (XLR 5-pin)
Connects the intercom headset.
To use a headset with a plug other than an XLR 5-pin plug,
consult a Sony service or sales representative.
jNetwork indicator
Displays the network system connection status.
On: When CNS SETTING in the NETWORK SETTING menu
is set to either BRIDGE or MCS, this indicates that
external control equipment (MSU-1000/1500 Master
Setup Unit, RCP-1000-series Remote Control Panel, or
other device) is connected.
Flashing: When CNS SETTING in the NETWORK SETTING
menu is set to either BRIDGE or MCS, this indicates a
connection problem with the external control equipment
(MSU-1000/1500 Master Setup Unit, RCP-1000-series
Remote Control Panel, or other device).
Off: When CNS SETTING in the NETWORK SETTING menu
is set to either BRIDGE or MCS, this indicates that a LAN
cable is not connected or that the network system
connection parameters have not been set.
When the CNS SETTING in the NETWORK SETTING
menu is set to LEGACY, this remains turned off.
kCall button
When pressed, this outputs a call signal to the camera and
external control device (the RCP-1000 series, etc.) that are
connected to this unit. Use this when you want to call and
speak with the camera operator or external control device
operator via intercom.
lMenu lock switch
This locks out operation of the front panel menu operation
area.
mAssignable button
You can set a function for this button via the CCU menu.
nStatus display indicator
REF IN (Green): REFERENCE is being input.
UNLOCK (Red): The input REFERENCE is not locked.
COM ERROR (Red): There is a communication failure with
the camera or other external control equipment (such as
the RCP-1000 series Remote Control Panel).
FAN STOP (Red): The power fan is stopped.
MIC/PGM (microphone/program) switch
INTERCOM (intercom select) switch
INTERCOM (intercom adjustment) knob
INTERCOM connector (XLR 5-pin)

14 Locations and Functions of Parts
HDCU2500 Rear Panel
aExpansion slots
For installation of an optional HKCU2007 3G/HD SDI Output
Expansion Unit, HKCU1001 SD Encoder Unit, or HKCU1003
Multi Interface Unit.
For details on installation, contact a Sony service or sales
representative.
bHD/SD SDI OUTPUT (SDI output connectors) area
(BNC-type)
The signal from the video camera may be output as two HD-
SDI signals or two SD-SDI signals. The signals output from the
OUTPUT3 and OUTPUT4 connectors can be superimposed
character and marker signals.
Signals of the same format are output from the SDI 1 and SDI
2 connectors; similarly, signals of another format can be
output from the SDI 3 and SDI 4 connectors.
For details on settings, contact a Sony service or sales
representative.
cREFERENCE connectors (BNC-type)
Input an HD tri-level reference sync signal or SD reference
sync signal (black burst signal, or black burst signal with 10
Field ID) to either of the two connectors.
The input signal is output from the other connector as is (loop-
through output). If loop-through output is not used, terminate
the unused connector at 75 ohms.
The type of reference signal is selected using the setup menu,
or using the MSU-1000 series Master Setup Unit.
For details on the setup menu, contact a Sony service or sales
representative.
Note
To use the VBS signal of the HKCU1001 SD Encoder Unit or
the HKCU1003 Multi Interface Unit (when SC phase lock is
required), use an SD reference sync signal (black burst
signal).
When black burst signal with 10 Field ID is input, REF 10F BB
of OTHERS (C23) must be set to ON.
dHD TRUNK OUT connector (BNC-type)
When an HD TRUNK function-compatible camera is
connected to the CAMERA connector, the HD-SDI signal input
to the camera’s HD TRUNK IN connector is output from the
HD TRUNK OUT connector.
eHD PROMPTER IN connector (BNC-type)
When an HD prompter function-compatible camera is
connected to the CAMERA connector, the HD-SDI signal input
to the HD PROMPTER IN connector is output from the
camera’s SDI connector.
78924 6 013
qa qs
5
qkqd qjqhqgqf

15
Locations and Functions of Parts
Note
Input an HD-SDI signal with a frequency synchronized to the
camera control unit.
fPROMPTER (tele-prompter) connectors (BNC-type)
Input a teleprompter signal to either of the two connectors. The
input signal is output from the other connector as is (loop-
through output). If loop-through output is not used, terminate
the unused connector at 75 ohms. If the signal used is a 1.0
Vp-p, 75-ohm signal, it may be output from the PROMPTER
OUT connector of the video camera with a frequency
bandwidth of 5 MHz, regardless of signal format.
RET4 (return video input 4)
When required, either of the PROMPTER connectors can be
assigned for the fourth return video input, exclusively for
analog VBS signals.
For details on settings, contact a Sony service or sales
representative.
gNETWORK TRUNK connector (RJ-45 8-pin)
Used for connecting the NETWORK TRUNK connector of the
device connected to the camera with the network connection
device.
h(LAN) connector (RJ-45 8-pin)
For LAN connection. Connect a LAN HUB (10BASE-T/
100BASE-TX), using a LAN cable (shielded type of category 5
or more).
iAUDIO OUT CH1, CH2 (audio output 1, 2) connectors
(XLR 3-pin)
Used for output of the audio signal to the AUDIO IN
connectors of the video camera.
jCAMERA connector (optical fiber connector)
Used to connect a video camera, using an optical fiber cable.
All video camera signals, including power supply, control,
video, and audio, are sent and received over one optical fiber
cable.
Note
Dust on the connection surface of the optical fiber cable may
result in transmission errors. When not connected, always
cover the end of the connector with the supplied cap.
kINTERCOM/TALLY/PGM (intercom/tally/program
audio) connector (D-sub 25-pin)
Used for input and output of intercom, tally, and program audio
signals. Connect to the intercom/tally/program audio
connector of the intercom system.
Flag function: 10-pin is assigned for the output pin of the Flag
function.
lSDI1, SDI2, SDI3 (serial digital interface output 1, 2, 3)
connectors (BNC-type)
The signal from the video camera may be output as two 3G-
SDI or HD-SDI signals. The SDI1 connector and the SDI2
connector output the same format signal. The signal output
from the SDI3 (MON) connector can be a superimposed
character or marker signal.
mRET1, RET2, RET3 (return video input 1, 2, 3)
connectors (BNC-type)
• Three different return video input signals may be received
independently.
• The selection of the return video input signal is made by the
return video switch of the video camera.
• The input signal may be set to 3G-SDI, HD-SDI, SD-SDI, or
analog VBS, using the setup menu, or using the MSU-1000
series Master Setup Unit.
For details on the setup menu, contact a Sony service or sales
representative.
Refer also to the Master Setup Unit manual.
nRCP/CNU connector (round 8-pin)
Used to connect to an MSU-1000 series Master Setup Unit,
CNU-700 Camera Command Network Unit, or RCP-1000
series Remote Control Panel via a CCA-5 Connection Cable.
Control signals are sent and received via this connector. When
using an RCP-1000 series unit, power is also supplied.
oMIC REMOTE (microphone remote) connector (D-sub
15-pin)
Using this connector, the video camera’s microphone input
level may be set by external equipment such as an audio
mixer, in five level (–60, –50, –40, –30, and –20 dB). When
shooting, set the volume to a level appropriate for the audio
conditions. This connector also outputs red, yellow and green
tally signals.
When DSUB-15 in the CCU CONFIGURATION menu is set to
WF REMOTE and an MSU-1000 series Master Setup Unit or
an RCP-1000 series Remote Control Panel is used to
remotely control a waveform monitor display, use a connector
that is compatible with recall-type waveform monitors. On the
recall-type waveform monitor, set/preset the display mode to
waveform monitor, and then select (recall) that mode
externally.
The microphone input level may also be set using the setup
menu. For details on the setup menu, contact a Sony service
or sales representative.
pCHARACTER/SYNC connector (BNC-type)
Outputs the self-diagnostic results or the setup menu as an SD
monochrome analog video signal.
When CHARA/SYNC in the CCU CONFIGURATION menu is
set to SYNC, this can also be used as a SYNC connector.
SD composite sync or an HD3 synchronous signal will be
output from the internal sync signal generator. (The default is
set to SD composite sync.)
For details on signal selection, contact a Sony service or sales
representative.
qTRUNK A connector (round 12-pin)
Used to connect to the CCU connector on a video camera via
an RS-232C or RS-422A interface. Communication with up to
two channels is available.
rAC IN (AC power input) connector
Use the specified AC power cord to connect to an AC power
supply. The AC power cord can be secured to this unit, using
the plug holder (optional).

16 Locations and Functions of Parts
Internal Switches
Note
To reduce the risk of electric shock, fire or injury, do not open
the cabinet. To adjust the internal settings, refer to qualified
service personnel.
There are no internal switches on HDCU2000.
HDCU2500 Internal Switches
The following switches are located inside the unit, behind the
front panel:
aInternal main power switch
When an abnormality has occurred, and power cannot be cut
off with the POWER switch on the front panel, you may turn off
the unit using the internal main power switch. When the switch
is set to OFF, setting the POWER switch on the front panel to
ON doesn’t turn on the unit.
HKCU2007 3G/HD SDI Output
Expansion Unit (optional)
Note
To reduce the risk of electric shock, fire or injury, do not open
the cabinet. To adjust the internal settings, refer to qualified
service personnel.
The HKCU2007 3G/HD SDI Output Expansion Unit consists of
a DRX front board and an HIF rear board.
When these boards are installed in the front and rear
expansion slots of the unit, the number of 3G/HD-SDI output
connectors increases by four. These can also be installed on
HDCU2000/2500’s expansion slots.
The format of SDI signals output via each upper/lower pair of
connectors on the HIF board can be set.
For details on installation, contact a Sony service or sales
representative.
HIF-57 Board
aSDI OUT 1, 2, 3, 4 (3G/HD serial digital interface output
1-4) connectors (BNC-type)
The signal from the video camera may be output as four 3G-
SDI or HD-SDI signals.
HKCU1001 SD Encoder Unit (optional)
Note
To reduce the risk of electric shock, fire or injury, do not open
the cabinet. To adjust the internal settings, refer to qualified
service personnel.
The HKCU1001 consists of an EN-A front board and a VDA-A
rear board.
When these boards are installed in the front and rear
expansion slots of the unit, the unit outputs SD composite
signals, waveform monitor output signals, and picture monitor
output signals through the VDA-A board’s connectors.
For details on installation, contact a Sony service or sales
representative.
VDA-A Board
1
1
3
2
4
SDI OUT
1
VDA-A
1
2
PIX
OUT
WF
OUT
VBS
1
2
3

17
Locations and Functions of Parts
aVBS 1, 2 (composite video output 1, 2) connectors
(BNC-type)
The signal from the video camera may be output as two
analog composite signals.
bPIX OUT (picture monitor output) connector (BNC-
type)
Outputs the video signal for a picture monitor selected with the
PICTURE MONITOR button of an RCP-1000 series Remote
Control Panel or MSU-1000 series Master Setup Unit.
Character signals or marker signals can be superimposed on
the video signal output through this connector.
For details on these operations, refer to the Master Setup Unit
or Remote Control Panel manuals.
cWF OUT (waveform monitor output) connector (BNC-
type)
Outputs the video signal for a waveform monitor selected with
the WF MONITOR button of an RCP-1000 series Remote
Control Panel or MSU-1000 series Master Setup Unit.
For details on these operations, refer to the Master Setup Unit
or Remote Control Panel manuals.
HKCU1003 Multi Interface Unit
(optional)
Note
To reduce the risk of electric shock, fire or injury, do not open
the cabinet. To adjust the internal settings, refer to qualified
service personnel.
The HKCU1003 consists of an EN-B front board and three
VDA rear boards (A/B/C).
When the EN-B board and one of the VDA rear boards are
installed in the front and rear expansion slots of the unit, the
unit inputs or outputs the following signals.
• Outputs SD composite signals, waveform monitor output
signals, and picture monitor output signals through a VDA-
A board.
• Inputs/outputs the frame sequence signal when operating a
24P system through a VDA-B board.
• Outputs analog component signals or analog composite
signals through a VDA-C board.
When you use either the VDA-A board or the VDA-B board,
insert the EN-B board in the corresponding expansion slot on
the front of the HDCU2000/2500. When either the VDA-A
board or the VDA-B board is installed, you can insert the VDA-
C board in an expansion slot on the rear panel of the
HDCU2000/2500. Don’t insert any board in the corresponding
expansion slot on the front of the HDCU2000/2500.
For details on installation, contact a Sony service or sales
representative.
VDA-A Board
aVBS 1, 2 (composite video output 1, 2) connectors
(BNC-type)
The signal from the video camera may be output as two
analog composite signals.
bPIX OUT (picture monitor output) connector (BNC-
type)
Outputs the video signal for a picture monitor selected with the
PICTURE MONITOR button of an RCP-1000 series Remote
Control Panel or MSU-1000 series Master Setup Unit.
Character signals or marker signals can be superimposed on
the video signal output through this connector.
For details on these operations, refer to the Master Setup Unit
or Remote Control Panel manuals.
cWF OUT (waveform monitor output) connector (BNC-
type)
Outputs the video signal for a waveform monitor selected with
the WF MONITOR button of an RCP-1000 series Remote
Control Panel or MSU-1000 series Master Setup Unit.
For details on these operations, refer to the Master Setup Unit
or Remote Control Panel manuals.
VDA-B Board
aFRAME REF IN, OUT (frame reference input/output)
connectors (BNC-type)
VDA-A
1
2
PIX
OUT
WF
OUT
VBS
1
2
3
FRAME
REF IN
PIX
OUT
WF
OUT
OUT
VDA-B
1
2
3

18 Locations and Functions of Parts
Input an HD tri-level reference sync signal or SD reference
sync signal (black burst signal) for the sequence-lock between
the camera control units, to the upper of the two connectors.
The input signal is output from the lower connector as is (loop-
through output).
When not using the OUT connector, terminate it at 75 ohms.
bPIX OUT (picture monitor output) connector (BNC-
type)
Outputs the video signal for a picture monitor selected with the
PICTURE MONITOR button of an RCP-1000 series Remote
Control Panel or MSU-1000 series Master Setup Unit.
For details on these operations, refer to the Master Setup Unit
or Remote Control Panel manuals.
cWF OUT (waveform monitor) connector (BNC-type)
Outputs the video signal for a waveform monitor selected with
the WF MONITOR button of an RCP-1000 series Remote
Control Panel or MSU-1000 series Master Setup Unit.
For details on these operations, refer to the Master Setup Unit
or Remote Control Panel manuals.
VDA-C Board
aVBS (composite video signal output) connector (BNC-
type)
The signal from the video camera may be output as an analog
composite signal.
bR/R-Y, G/Y, B/B-Y (component video signal output)
connectors (BNC-type)
The signal from the video camera may be output as a R/R-Y,
G/Y, B/B-Y component signal or an RGB component signal.
VBS
R/R-Y
G/Y
B/B-Y
VDA-C
1
2

19
Connections and Settings
Connections and Settings
Fiber Transmission System of Dual Link Format
The camera and the camera control unit are connected via a
single optical fiber cable, and transmission is achieved at
“High Bit Rate.”
Connection example 1
Settings
Camera
MAINTENANCE menu, <SDI OUT> page:
Set SDI-1 OUT to HD PROMPTER.
Camera control unit
Format: Select a Dual Link format of 1080/59.94P or 1080/
50P.
INCOM
INTERCOM 1
PROD
LEVEL
REAR
FRONT
MIC
ON
OFF ENG
OFF
+48V
MIC
FRONT MIC
PROMPTER
/GEN
LOCK
RET CTRL
AUDIO IN
CH1 CH2
TEST
OUT
SDI
MONI
DC IN 10.5-17V
LINE
OFF
+48V
MIC
AES/EBU
LINE
INCOM
INTERCOM 2
EARPHONE REMOTE
DC OUT
CRANETRACKER
PROD
LEVEL
REAR
FRONT
MIC
ON
OFF ENG
SDI OUT 2
(SLOT1)
SDI OUT 1
(SLOT1)
SDI OUT 3 (SLOT1)
SDI OUT 4
(SLOT1)
LINK-A LINK-B
LINK-A LINK-B
RETURN
INPUT
SDI 1-4
CAMERA
REFERENCE
HD PROMPTER IN
SDI 1
CCU
Optical fiber cable (High Bit Rate)
HD prompter source
(HD-SDI)
Prompter/
Floor monitor
VTR Switcher
(Dual Link)
Monitor
(Dual Link) Hub
Network cable
BNC cable
(HD-SDI)
Reference
signal
MSU-1000/1500
Master Setup Unit
RCP-1500/1501/1530
Remote Control Panel
HDC2500
HDCU2000
RET (SD-SDI/HD-SDI/3G-SDI)
RET (SD-SDI/HD-SDI/3G-SDI)
RET (SD-SDI/HD-SDI/3G-SDI)
RET (SD-SDI/HD-SDI/3G-SDI)

20 Connections and Settings
Connection example 2
Settings
Camera
MAINTENANCE menu, <SDI OUT> page:
Set SDI-1 OUT to HD PROMPTER.
Camera control unit
Format: Select a Dual Link format of 1080/59.94P or 1080/
50P.
INCOM
INTERCOM 1
PROD
LEVEL
REAR
FRONT
MIC
ON
OFF ENG
OFF
+48V
MIC
FRONT MIC
PROMPTER
/GEN
LOCK
RET CTRL
AUDIO IN
CH1 CH2
TEST
OUT
SDI
MONI
DC IN 10.5-17V
LINE
OFF
+48V
MIC
AES/EBU
LINE
INCOM
INTERCOM 2
EARPHONE REMOTE
DC OUT
CRANETRACKER
PROD
LEVEL
REAR
FRONT
MIC
ON
OFF ENG
SDI OUT 3
(SLOT1)
SDI OUT 1
(SLOT1)
RETURN
INPUT
SDI 1-4
HD PROMPTER IN
SDI 1
CCU CAMERA
REFERENCE
HDC2500
HDCU2000
Optical fiber cable (High Bit Rate)
HD prompter source
(HD-SDI)
Prompter/
Floor monitor
VTR Switcher
(3G-SDI)
Monitor
(3G-SDI) Hub
Network cable
BNC cable
(HD-SDI)
Reference
signal
MSU-1000/1500
Master Setup Unit
RCP-1500/1501/1530
Remote Control Panel
RET (SD-SDI/HD-SDI/3G-SDI)
RET (SD-SDI/HD-SDI/3G-SDI)
RET (SD-SDI/HD-SDI/3G-SDI)
RET (SD-SDI/HD-SDI/3G-SDI)
Other manuals for HDCU2000
1
This manual suits for next models
4
Table of contents
Other Sony Control Unit manuals
Popular Control Unit manuals by other brands

Emerson
Emerson ASCO 290 Series Installation and maintenance instructions

Eaton
Eaton ELC-CADNET instruction sheet

A.R.I.
A.R.I. Eliptix W-30 A Installation, Operating, Maintenance

Skipper
Skipper DB-100-SA Installation and operation manual

Mitsubishi
Mitsubishi MELSEC-Q QD77MS user manual

Leadshine
Leadshine DM805-AI Hardware installation manual