4999DR-071-05
Calrec Omega Digital Audio Mixing
System
Requirements
• Large Audio Mixer Interface Software Option
• Serial Interface Cables DB9
• If the cable connection between the switcher and the Calrec
Omega is longer than 50 feet, an RS-232 to RS-422 converter is
required at the Calrec Omega.
Port Connections
Pinouts
Switcher Setup
To Set Up Communications
1. Press HOME Setup Installation Com Setup
Type.
•UsetheCom Port knob to select the Remote Xport that you
connected the Calrec Omega to.
•UsetheDevice knob to select Audio Mixer.
2. Press Select Device.
•UsetheDevice knob to select RAP.
3. Press Com Type.
•UsetheType knob to select RS-232 (RS-232 NULL on the
Synergy 1).
4. Press Com Settings.
•UsetheBaud knob to select 115200.
•UsetheParity knob to select ODD.
5. Press Extra Options.
6. Press HOME Confirm.
To Assign Audio Channels to BNCs
1. Press HOME Setup Installation BNC Audio.
2. Use the BNC knob to select the Input BNC that you want to
assign an audio channel to.
3. Use the Audio 1 knob to select an audio channel, or group, that
you want to assign to the selected Input BNC.
4. Use the Audio 2 knob to select another audio channel, or group,
that you want to assign to the selected Input BNC.
5. Press HOME Confirm.
Refer to your switcher manual for information on creating audio
groups, or setting default audio levels.
Device Setup
Ensure the port on the Calrec Omega Digital Audio Mixer that is
connected to the switcher is configured for RS-232.
Compatibility
Switcher Audio Mixer
Communications REMOTE Port
(female) RS-232
Switcher Calrec Omega
2 (Tx) 3 (Rx)
3 (Rx) 2 (Tx)
5 Ground 5 Ground
Extra Options Value
TargetMachine Calrec
OD Master M1 (default)
Audio Mixer Version
Calrec Omega Digital Audio Mixer --
Switchers
Synergy 1 SD --
Synergy Series SD 18.0 or higher
Synergy MD/X 8.2 or higher
Vision MD/X 8.2 or higher
Vision QMD/X 8.2 or higher
Vision MultiPanel Support --
Automation
OverDrive 6.0 or higher
Port Expanders
BSS4
Comtrol DeviceMastera
a. You must set Server/Client to Server on the Com
Settings of the Communications Menu 1-2 when
connecting to a Comtrol DeviceMaster.
Extra Options Value