Rossi DZ ATTO TURBO User manual

Tx
Smart Products
Sliding Line
DZ ATTO TURBO / DZ NANO TURBO/ DZ NANO Bi TURBO/
DZ3 / DZ3 TURBO / DZ4 / DZ4 TURBO / DZ4 Bi TURBO SIA 30 FS
Installation
1 - Observe if the gate is sliding freely in all its route, observing
support guide, rail, stops and pulleys
2 - Provide a power and ground point, passing a conduit,
starting from the driver to the power board with a 10A bipolar
circuit breaker.
NOTE: It is mandatory to install a shutdown device (bipolar
circuit breaker with minimum contact opening equal to 3mm)
that must be incorporated into fixed wiring.
3- Provide the means by which you want to fix the drive.
•
Concrete Base • Metal Base • Cross Arm Brace (Air Base) Use
the measurements in the manual to mark the location of the
bolts.
4- Place the washers on the base, screw the driver onto the
washers and place the driver in the manual mode.
5 - Close the gate, support the rack on the gear and fix the bar
in the gate with solder or screw, 30 by 30 cm.
6 - Once the racks have been fixed, remove the washers placed
on the base and fix the motor again, and check the spaces
between the rack and the gear.
NOTE: " The washers placed at the beginning of the racks
attachment serve to give the minimum mandatory height of 2
mm between the rack and the external gear of the engine."
NOTE: " Failure to observe this distance may result in wear on the
drive's internal and external gears or breakage of the rack with
engine starting."
7- Adjust the end magnets in open mode FA and closed FF,
placing a magnet on each end of the rack, observing the polarity of
each magnet between open and closed gate.
NOTE: "The magnets must always be attached to the angle
bracket, even during opening and closing adjustments to
prevent damage to the control unit"
8 - Fix the control unit on the support guide inside the actuator
(fixing instructions Page2).
9 - End of stroke HALL sensor The hall sensor identifies the
polarity of the magnets, north and south. (instructions Page 6)
NOTE: For bench tests, it should simulate the movement of
the magnet installed in the gate, remembering that when the
control is activated the limit switch must be active.
In the installation and adjustment of the magnets, in the first
two commands the control unit must recognize the FA and FF
magnets.
10 - The use of the Active infrared sensor - SIA 30 is
MANDATORY to activate the system of anti-locking protection,
avoiding collision with obstacles, accidents with people or material
goods.
11 - The gates and actuators need periodic maintenance and
lubrication every 6 months for proper operation.
Rev 05/18 - COD. 12443 www.rossiportoes.com.br Page 1
1
Support guide
Rail and Stopper
Pulleys
FA -End of stroke open gate
FF - End of stroke closed gate
234
Washers

t
h
central fitting
central fixing
central fixing
Central fixed with screw
Central fixing
Page 2
7
Fixing
Hall magnet
FA - Open
FF - Closed
Measurements in
millimeters
Face of the
Gate
227mm
Dz3 / DZ4
227mm
DZ3 TURBO / DZ4 TURBO
DZ4 BI TURBO
189.50mm
Dz3 / DZ4 / DZ3 TURBO / DZ4 TURBO
DZ4 BI TURBO
Face of
the Gate
227m
m
DZ NANO TURBO
DZ NANO BI TURBO
DZ ATTO TURBO
189.50mm
DZ NANO TURBO
DZ NANO BI TURBO
DZ ATTO TURBO
272mm
222 mm
58 mm
72 mm
272mm
,
74
192mm
151mm
72 mm
70mm
203mm
140mm
83
mm
83mm

Technical Features
Technical Data Line DZ
Dz Atto turbo Dz Nano turbo Dz3 Dz3 turbo Dz4 Dz4 turbo
Tension
127 / 220 V
127 / 220 V
127 / 220 V
127 / 220 V
127 / 220 V
127 / 220 V
Power
370 W
420 W
420 W
420 W
500 W
500 W
Frequency
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
Protection Degree
IP 44
IP 44
IP 44
IP 44
IP 44
IP 44
Class
II
II
II
II
II
II
Operation Time
-20°C ~ 55°C
-20°C ~ 55°C
-20°C ~ 55°C
-20°C ~ 55°C
-20°C ~ 55°C
-20°C ~ 55°C
Rack Module
M4
M4
M4
M4
M4
M4
Opening Speed
17m/min
17m/min
12m/min
17m/min
12m/min
17m/min
Technical Data BiTurbo Line
Dz Nano Bi Turbo
Dz4 Bi Turbo
Tension
127 / 220 V
127 / 220 V
Power
420 W
500 W
Frequency
50/60 Hz
50/60 Hz
Protection Degree IP 44 IP 44
Class
II
II
Operation Time
-20°C ~ 55°C
-20°C ~ 55°C
Rack Module
M4
M4
Opening Speed
34m/min
34m/min
NOTE: View of parts and codes for the drives available on the website:
http://www.rossiportoes.com.br/produto_linha
! A T T E N T I O N !
Follow each one carefully:
1 - The installer must follow all instructions contained in this manual.
2 - Keep automatic equipment controls (control buttons, remote control etc.) out of reach of children. 3 - Perform control
operations from points where the automatic gate is visible.
4 - Use remote controls only if you can see the automatic gate.
5 - Warning: ROSSI assumes no liability for any damage caused by non-observance, at the time of installation, of safety regulations and laws
currently in force. NBR 5410:1997 - ABNT - Associação Brasileira de Normas Técnicas.
6 - This manual is intended exclusively for specialized personnel who are aware of the manufacturing criteria and the accident protection devices
related to motorized gates and doors.
7- If not provided for the switchboard, install beforehand a bipolar disconnect type switch with a minimum contact opening of 3mm,
of a mark which complies with international standards and provide for the equipment grounding.
8- For cables section, ROSSI recommends using a minimum section of 2.5mm and observing the laws in force in the country.
9- Keep this manual for future reference
10- This appliance is not intended for use by people (including children) with reduced physical, sensory or mental capacities, or people with
lack of experience and knowledge, unless they have received instructions regarding the use of the device or are under the supervision of a
person responsible for their safety.
11- It is recommended that children be supervised to ensure that they are not playing with the device. 12- The installer must provide all
information regarding automatic operation, emergency unlocking and deliver the user manual with the appropriate information.
13- It is mandatory to use the active infrared sensor - SIA 30 FS, to activate the anti-locking protection system and allow the FS control unit to
operate, avoiding collision with obstacles and accidents with people or material goods.
14- Before installing the unit, check that the driven part is in good mechanical condition, correctly balanced and opens and closes correctly
15- Check the installation frequently to detect imbalances and signs of wear or damage to cables, springs and assembly. Do not use in case
of repairs or if adjustment is required.
16- Disconnect the equipment from the power when cleaning or maintening.
17- Check if the temperature of the equipment is indicated and where it will be used.
Page 3

User Manual
UNLOCKING FOR MANUAL OPENING
Turn and turn the key clockwise
and pull the lever up to 120°.
12 Pull the lever. 3 Leave at 120°
120°
a Put and rotate
key in clockwise
directio
n
SIA30 FS
INSTALATION
Active Infrared Sensor
-
The gate barrier sensor SIA30 must be installed with a max. distance between the Transmitter and the Receiver.
-
It must be at the same height and in the same alignment (when aligned the led indicator of the receiver goes out), ideal height for installation in gates is
50cm.Fig 01
- Installation should be done as close as possible to the gate.
NOTES ON INSTALLATION
•
Do not set near plants and objects that could interrupt the beam of SIA30
•
The transmitter and receiver can not be installed on mobile, unstable bases or in places that move easily.
•
Always leave lenses clean
•
Do not install the receiver with the lens facing the sun.
FEATURES
•
Transmitter
-
Power Supply 12Vcc
-
Consumption 30mA
•
Receiver
-
Power Supply 12Vcc
-
Consumption 25mA
•
Maximum distance - 30m
•
Easy alignment
•
Box with solar filter
•
Drive indicative LED on RX
•
Works in NA or NF mode
•
Contacts NF - NA Maximum current 1A
Rx Tx
Easy alignment
Max. 30m
0.50m
Tx
Page 4
DIGITAL ACCESS KEY CONFIGURATION HCS (Rolling Code)
To add the digital key code to the control panel, press and release the "LEARN"
button on the control panel or the Rossi receiver and immediately press one of
the key's buttons. To record other buttons, repeat the operation.
Note: buttons 1 and 2 of the key are independent.
Erase memory - If you want to erase all the codes of the keys recorded on the
control panel, press the "LEARN" button and keep pressed until the "ST" LED
goes out.
Digital access key
Command Center
R
X
drilling
measures

Neutral
Output 12V
12V
Commom GND
Common (yellow WIRE)
Version 1.2 year 2014
Motor Wires
Output To Locking Plate
Input Photocell - RX
Negative (-) TX of photocell FS
Starting Capacitor
Phase Input
90 - 240V ~ ac
Adjust Button
- Brake
- Soft stop
Hall-Sensor
Clutch Adjustment
Led - ST
Soft Stop –1
Enable Lock - 2
Pause (automatic closing) - 3
Building / Residential - 4
Jumper-
Note: For compatibility with previous
versions close Jumper
Green Led - FA (End of Stroke Open)
Red Led - FF (End of Stroke Closed)
Learn / Delete button
Features
KXH 30 FS
Hall Sensor and Auto Source
FAIL SAFE
FUNCTION Installation Manual
Traffic light/ Garage light
Switch
GND
Antenna
-Automatic source 90V - 240V ~ ac - Receiving frequency 433 Mhz - Programmable soft stop - Traffic Light / garage light output
-Limit switch HALL sensor - Residential and building function - Switch - Photocell input
-Internal memory for 30 buttons - Adjustable automatic closing (Pause) - Adjustable electronic clutch - Exit lock (FHC)
-HCS reception system, anti-cloning - Soft start - Clears individual passkey codes
Page 5
Warranty term
This product has been designed and manufactured to fully
meet the technical specifications described in the booklet
that comes with it.
It is IMPORTANT that this term is read, as well as the
entire User Manual and the technical specifications of the
product and instructions for its correct installation.
INDÚSTRIAS ROSSI ELETROMECÂNICA S/A,
in accordance with Law 8078/90, certifies that the product
is in perfect conditions of use and suitable for its intended
purpose, ensuring it against any defect in the design,
manufacture or quality defect of the material that makes it
improper or inappropriate to the use for which it is intended,
for a period of one (1) year, including the legal warranty
period of 90 days, counted from the issue date of the
Invoice to the consumer.
|||UNTRANSL
ATED_CONTENT_START|||Quando o
consumidor se deparar com algum eventual defeito de
fabricação dentro do prazo de garantia, deverá entrar em
contato com os dados da Nota Fiscal de compra, podendo
também localizar no site um distribuidor:
http://www.rossiportoes.com.br/ondeencontrar
para que
seja realizada a avaliação do
produto.|||UNTRANSLATED_CONTENT_END|||
The warranty will be totally invalid if any of the following
situations occurs:
a)
If it is found that the defect is not of manufacture;
b)
If it is found that the defect of the product was caused
by misuse or improper use, fortuitous or force majeure
(lightning, flooding, flooding, landslides, etc.), a defect in
the electrical network.
c)
If the product is found to be defective due to exposure to
chemicals, electromagnetic interference, high humidity,
excessive heat and/or cold;
d)
If it is found that the product defect was caused by
accidents, falls, attacks by pests or agents of nature;
e)
If the manufacturing label has been removed from the
product;
f)
If the product has been violated and/or underwent
modifications made by third parties not authorized by
INDÚSTRIAS ROSSI ELETROMECÂNICA S/A;
g)
If the product undergoes natural wear, due to failure to
follow
the instructions for use and maintenance in the
User Manual;
h)
If it is found that the product's unsatisfactory
performance originates from an improper installation, in
disagreement with NBR 5410: 1997 - ABNT - Brazilian
Association of Technical Standards (Associação
Brasileira de Normas Técnicas) and with the instructions
accompanying the product, or the electrical network
where it is connected (see technical specifications of the
equipment)
i)
If the product is being used in an application for which
it has no
t been designed or exceeds the maximum
operating cycle causing the engine to burn or the wear of
internal components;
ATTENTION! The product installation must follow the
instructions that accompany the product, under penalty of
invalidation of this guarant
ee. The expenses necessary
for the installation, as well as the purchase of materials
necessary for the installation, besides optional resources,
will be the responsibility of the consumer.
ATTENTION! The use of the active infrared sensor - SIA
is indispen
sable, under penalty of invalidation of this
guarantee.
30 to activate the anti-
jamming protection system The
absence of this sensor can cause collision with
obstacles, accidents with people, animals or material
goods.
ATTENTION! Keep children and pets away from the gate
at the time of its operation. ATTENTION! The product
has been developed for generic use, not for the specific
purpose of
each consumer. Therefore, this warranty is limited to
meeting the purposes set forth in the User Manual.
ATTENTION! If the equipment is defective, immediately
seek the technician who installed the equipment through
the address and telephone number filled in or stamped on
this certificate.
INDÚSTRIAS ROSSI ELETROMECÂNICA S/A
reserves the right at any time to modify and/or introduce
improvements to this product without incurring an
obligation to do the same for products in stock or already
sold.
Resale Stamp
Customer service:
www.rossiportoes.com.br

1
2
3
4
1
2
3
4
ON
W - V - U - Motor Wires
The motor has 3 wires.
The common (check label on the motor) usually the yellow one
must be connected to the U output.
The outputs V and W determine the motor rotation direction
(right - left).
Note that the 1st central control must open the gate. If
the 1st control closes the gate, reverse the V and W
wires.
Note that this 1st control is a factory test pattern, if this control
has already been turned on, it will be stored the last activated
end of stroke (open or closed). To do this test, leave the gate
open halfway and start.
N/F - Input 90-240V ~ ac
Automatic source
Voltage input already intercepted
by a 10A bipolar circuit breaker
and grounding the equipment.
CAP- Starting Capacitor
Capacitor according to the motor
power, the wires have no
polarity.
Output GND - 12V
Power supply output for ROSSI
accessory plates, garage light
plate, driver board, door lock
plate, SIA 30 Photocell.
FCH Output - Lock
for interconnecting locking
accessory plate, it is mandatory
to enable Dip 2
Sensor Hall End of Stroke
The sensor hall identifies the magnets polarity, north
and south. Before attaching the magnets, identify the
FA and FF by moving the magnet on the rack until it
passes in front of the sensor hall that will light the
green led "FA" or red "FF". (If the two magnets light
the same led choose one of the magnets to reverse
the polarity.) HALL calibration: If one of the LEDs FA
or FF is lit, with the gate in the middle of the path, the
Hall must be calibrated (remove the energy from the
plate press the LEARN button and with your finger
pressed turn the power on again then release the
button).
SIN -GND - Traffic light
consists of interconnecting a
signal with the central gate
using the terminals SIN and
GND.
SIN -GND - Garage light. to
interconnect the garage
LIGHT accessory board.
GND/ANT
LED ST
LEARN
LED ST - LEARN / MEMORY
:
Delete individual buttons:
This feature allows you to erase from the
central memory the encoding,
independently of the key code, without
affecting others. For this the access key
must be in hand to perform this procedure.
Hold down learn while pressing one of the
key switch you want to delete. Note: The
time must be shorter than to delete the
memory.
BOT/GND
•
1 - Soft stop
Enabled 1 - Smoth Stop Disabled
2 –Lock
3 –Pause
4 - Building
•
To enable, set the switch to ON position
TX-NF CM GND 12V
SIA 30 FS.
- connect the
photocell's GND to
the TX-terminal of
the control unit
Decrease gate speed shortly before reaching the end of stroke, with two levels of intensity, light or
heavy gate.
TX- 12v
GND 12v CM NF
to enable put DIP 1 to ON and press the SET button (6 times
- lightweight gate) or (7 times to return to the normal level).
Note: Enabling DIP 1 is at normal intensity.
-Photocell must be switched on in Normally Closed (NF)
Wiring diagram WITHOUT FS function
•
2 - Lock
The programming lock when enabled causes the control panel, after receiving an opening control, first
send a pulse to open the lock and after a few seconds starts opening the gate.
•
3- Automatic closing (Pause);
Set the pause switch to ON position and give the opening command. When the open limit switch (FA)
is reached, the ST LED will start flashing in 1-second intervals, allow the desired time to elapse for the
pause value and give the command again. Each flashing indicates 1 second elapsed until 12h (E.g. if
the LED blinks 20 times, the pause time will be 20 seconds. After this operation is completed, the
pause will be programmed, every opening that occurs and elapses in the programmed time will
automatically close the gate.)
To disable this feature, simply put the pause switch in the OFF position. In the next control the pause
will be disabled. (for this type of configuration, it is of utmost importance, for the safety of the user, to
use barrier sensors 'SIA 30'.)
•
4 - Building
NA CM GND 12V
Note: Connection mode
compatible with the
previous switches or with
the function Fail Safe
DISABLED (central FS
connection with the jumper
closed).
GND12v
GND12v CM NA
Building - All controls open the gate, that only closes by automatic closing, which will only stop at the
open limit, if there is another control during the opening, central will ignore it. After the gate reaches
the open limit switch it will start the automatic closing time count, the gate will only close after the
scheduled time elapses. If there is a remote control or button control, the time will be reset and the
count will start again. If the gate is closing, any control will make the gate stop and open again. (Note:
In building mode the automatic closing is enabled automatically, just adjust the time in the 1st control.)
Residential - Accepts all controls and pushbutton (1st - control opens, 2nd - to, 3rd – closes
10 - Clutch Adjustment
Clutch Adjustment
•
Adjust trimpot to minimum;
•
Start the engine through the remote control;
•
Gradually increase the drive force until you
move the gate;
•
adjust the trimpot slightly above that
necessary to move the gate.
Note: For compatibility with previous versions, close the Jumper
(Input NA)
-The gate barrier sensor must be installed with the Transmitter and Receiver.
-Must be at the same height and in the same alignment, ideal height for installation in gates is 50cm.
- Installation should be done as close as possible to the gate.
- The certification is valid only with the use of approved ROSSI photocells: SIA 30 FS
11 - Electronic Brake Adjustment
ADJUSTMENT - Adjustment of BRAKE levels
The control unit has 5 levels of electronic brake.
Press and release the SET button at intervals of less than 1sec. according
to the desired level.
Level 1 = 25% of brake - Press 1 time
Level 2 = 50% of brake - Press 2 times
Level 3 = 75% of brake - Press 3 times
Level 4 = 100% brake - Press 4 times
Level 5 = Press 5 times
NOTE: At the end of each setting, wait 2 seconds and the ST LED will
blink at which level it is programmed.
Page 6
05 - External button and traffic light / Light 06 - Antenna 07 - Record digital access key
08 - Dip programming 09 - Photocell connection - FAIL SAFE
Coaxial cable
up to 3M
16cm
• The Switch consists of installing a wrist button
(bell type) on the borne (BOT) of control panel or
interconnect a Receiver.
“The Switch is used for manual driving in cabinets,
driving by interphone or eventual need for driving
from distance by an external button.”
Frequency reception antenna, connect the stripped part of
the 16cm wire on borner - ANT
• If you need a wider range, connect a 2m coaxial cable
on the antenna input:
-
On the upper part of the cable you should uncover the
core at 16cm
On the part of connection to the control panel you should
put the core on borne ANT and the mesh at GND l
ike the
drawing at the control panel.
Recording of access key:
• Press and release the learn button on
the control panel;
• With the led on, press one of the buttons
of the key at the end of the recording; it
will flash indicating the programming was
acce
pted
Repeat the process to record other
buttons.
Note: Time should be shorter than for
deleting the memory.
Deleting the Memory: Press the button
LEARN and keep it pressed until ST LED
goes off; with this procedure, you delete
recorded codes.
Core
Mesh
16cm from core
without mesh
Photocell FAIL SAFE
function.
This manual suits for next models