Safran MorphoAccess J Series User manual

DOCUMENT SSE-0000077503-04 - March 2011
INSTALLATION GUIDE
Copyright © 2011
Morpho
Osny, France
Morpho Document - Reproduction and disclosure prohibited

Warning MorphoAccess® J Series – Installation Guide
DOCUMENT SSE-0000077503-04 - MARCH 2011
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
Warning
Copyright © 2011, Morpho. All rights reserved.
Information in this document is subject to change without notice and do not represent a
commitment on the part of Morpho. No part of this document may be reproduced or transmitted in
any form or by any means, electronic or mechanical, including photocopying or recording, for any
purpose without the express written permission of Morpho.
This legend is applicable to all pages of this document.
This manual makes reference to names and products that are trademarks of their respective owners.
Printed in France.

DOCUMENT SSE-0000077503-04 - MARCH 2011 REV • 1
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
MorphoAccess® J Series – Installation Guide Revision History
REVISION HISTORYREVISION HISTORYREVISION HISTORYREVISION HISTORYREVISION HISTORYREVISION HISTORY
Revision History
The table below contains the history of changes made to the present document.
Version Date Document Revision History
01 May 2010 Document creation.
02 May 2010 Modification of Customer service phone number on
page 75.
03 November 2010 Schemas modifications
04 March 2011 Minor text modifications

TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTS
MorphoAccess® J Series – Installation Guide Table of Contents
DOCUMENT SSE-0000077503-04 - MARCH 2011 TOC • 1
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
Table of Contents
Section 1 Introduction
1. Scope of the document . . . . . . . . . 3
2. Safety instructions . . . . . . . . . 4
Wiring recommendation . . . . . . . . . . 4
Europe information . . . . . . . . . . . 5
USA information . . . . . . . . . . . 5
Section 2 General Description
1. Box opening . . . . . . . . . . 9
2. Components of the initial package . . . . . . . 10
3. Terminal’s front view description . . . . . . . 11
4. Terminal’s rear view description . . . . . . . 12
5. MorphoAccess®J Series Technical Characteristics . . . . . 13
Section 3 Installation procedure
1. Installation directly on a wall . . . . . . . . 17
Required tools (not supplied) . . . . . . . . 17
Equipment from the initial package to use . . . . . . 17
Step by step procedure . . . . . . . . . 17
2. Installation on a standard electric box (example of the European electric box) . 21
Required tools (not supplied) . . . . . . . . 21
Equipment from the initial package to use . . . . . . 21
Step by step procedure . . . . . . . . . 21

TOC • 2 DOCUMENT SSE-0000077503-04 - MARCH 2011
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
Table of Contents MorphoAccess® J Series – Installation Guide
3. Installation with the Mounting Spacer supplied in the package . . . . 25
Required tools (not supplied) . . . . . . . . . 25
Equipment from the initial package to use . . . . . . . 25
Step by step procedure . . . . . . . . . . 25
4. Installation with specific Wi-Fi™ Mounting Spacer . . . . . 29
Required tools (not supplied) . . . . . . . . . 30
Equipment from the initial package to use . . . . . . . 30
Step by step procedure . . . . . . . . . . 30
5. Smoked front cover disassembly . . . . . . . . 36
Equipment from the initial package to use . . . . . . . 36
Step by step procedure . . . . . . . . . . 36
Section 4 Electrical interface
1. Wiring overview . . . . . . . . . . 41
2. Output relay . . . . . . . . . . . 42
Relay ratings . . . . . . . . . . . 42
Example of connection for electrical door locks . . . . . . 43
3. Tamper switch . . . . . . . . . . 44
Switch operating . . . . . . . . . . . 44
Tamper switch ratings . . . . . . . . . . 44
4. Power supply . . . . . . . . . . . 45
External power supply . . . . . . . . . . 45
5. Wiegand output wiring . . . . . . . . . 46
6. Data Clock output wiring & COM RS485 serial port . . . . . 47
Data Clock output wiring . . . . . . . . . 47
COM RS485 serial port . . . . . . . . . . 47
7. Ethernet wiring . . . . . . . . . . 48
Default IP address from factory: . . . . . . . . 48
RJ 45 wiring recommendations . . . . . . . . 49

TABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTSTABLE OF CONTENTS
MorphoAccess® J Series – Installation Guide Table of Contents
DOCUMENT SSE-0000077503-04 - MARCH 2011 TOC • 3
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
Section 5 User Interface
1. MorphoAccess® J Series terminal modes . . . . . . 53
Identification mode . . . . . . . . . . 53
Authentication (verification) mode . . . . . . . . 53
Multi-factor mode . . . . . . . . . . 53
Proxy mode . . . . . . . . . . . 54
2. MorphoAccess® J Series terminal Configuration . . . . . 55
3. Anti-tamper and anti-pulling switches operating . . . . . 56
Anti-tamper switches . . . . . . . . . 56
Anti-pulling switches . . . . . . . . . 57
Section 6 Compatible Accessories, Software Licences and Soft-
ware Applications
Section 7 Recommendations
Areas containing combustibles . . . . . . . . 63
General precautions . . . . . . . . . . 63
Specific precautions for terminals equipped with a contactless smartcard reader . 63
Ethernet connection . . . . . . . . . . 63
Date / Time synchronisation . . . . . . . . 64
Cleaning precautions . . . . . . . . . 64
Warning . . . . . . . . . . . 64
Section 8 Appendix 1: Fingerprint placement rules
Section 9 Appendix 2: Bibliography
Administrator Information . . . . . . . . . 71
Developer Information . . . . . . . . . 71
Support Tools . . . . . . . . . . . 72

SECTION 1
INTRODUCTION

2DOCUMENT SSE-0000077503-04 - MARCH 2011
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
Section 1: Introduction MorphoAccess® J Series – Installation Guide
Congratulations for choosing a MorphoAccess®J Series Automatic
Fingerprint Recognition Terminal.
MorphoAccess®J Series provides an innovative and effective solution for
access control applications using Fingerprint Verification or/and
Identification.
Among a range of alternative biometric technologies, the use of finger imaging
has significant advantages: each finger constitutes an unalterable physical
signature, developed before birth and preserved until death. Unlike DNA, a
finger image is unique to each individual - even identical twins.
MorphoAccess®J Series integrates Morpho image processing and feature
matching algorithms. This technology is based on lessons learned during 25
years of experience in the field of biometric identification and the creation of
literally millions of individual fingerprint identification records.
Designed for physical access control applications, MorphoAccess®J Series
features a compact, attractive design, coupled with high reliability and security.
These latest-generation terminals are both robust and easy to use for a variety
of applications, including office, headquarters and administrative building
security, as well as protection of external access points.
To ensure the most effective use of your MorphoAccess®J Series terminal, we
recommend that you read this Installation Guide completely.

DOCUMENT SSE-0000077503-04 - MARCH 2011 3
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
MorphoAccess® J Series – Installation Guide Section 1: Introduction
SECTION 1: INTRODUCTIONSECTION 1: INTRODUCTIONSECTION 1: INTRODUCTIONSECTION 1: INTRODUCTIONSECTION 1: INTRODUCTIONSECTION 1: INTRODUCTION
1. Scope of the document
This guide deals with the installation of MorphoAccess®J Series, which is
made up of following list of products:
Biometrics
Contactless Smartcard
Reader
MIFARE®DESFire®
MorphoAccess® J Series MorphoAccess® J-Bio x
MorphoAccess®J-Dual xxx

4DOCUMENT SSE-0000077503-04 - MARCH 2011
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
Section 1: Introduction MorphoAccess® J Series – Installation Guide
2. Safety instructions
The installation of this product should be made by a qualified service Person
and should comply with all local regulations.
It is strongly recommended to use a class II power supply at 12V ±5% and
0.5A. min (1A with Wi-Fi™ option) in conformity with Safety Electrical Low
Voltage (SELV). The 12V power supply cable length should not exceed 3
meters.
This product is intended to be installed with a power supply complying with
EN60950, in accordance with the NEC Class 2 requirements; or supplied by a
listed EN60950 external Power Unit marked Class 2, Limited Power source, or
LPS and rated 12VDC, 0.5A minimum (1A with Wi-Fi™ option).
In case of building-to-building connection it is recommended to connect 0V to
ground. Ground cable must be connected with the terminal block 0V GND.
Note that all connections of the MorphoAccess®J Series terminal described
hereafter are of SELV (Safety Electrical Low Voltage) type.
Wiring recommendation
Morpho recommends to use a gauge AWG18 for 12V power supply when POE
supply is not use.
For information, this table shows the maximum weakening voltage observed
on the terminal MorphoAccess®J.
Weakening = loss of voltage due to wire resistance and length
The voltage at the input of the MorphoAccess®J terminal (V2) is equal to the
voltage at the output of the power supply (V1) minus the weakening (Va), i.e.
V2=V1-Va.
AWG Diameter
(mm) Maximumweakening @ 1m Maximum weakening @ 3m
18 1.02362 0.015 V 0.044 V
20 0.8128 0.023 V 0.070 V
25 0.45466 0.074 V 0.223 V
28 0.32004 0.149 V 0.447 V

DOCUMENT SSE-0000077503-04 - MARCH 2011 5
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
MorphoAccess® J Series – Installation Guide Section 1: Introduction
SECTION 1: INTRODUCTIONSECTION 1: INTRODUCTIONSECTION 1: INTRODUCTIONSECTION 1: INTRODUCTIONSECTION 1: INTRODUCTIONSECTION 1: INTRODUCTION
Europe information
Morpho hereby declares that the MorphoAccess®J Series terminal has been
tested and found compliant with following listed standards: EN302 291-2
V.1.1.1 (2005-07) + recommendation 1999/519/CE with standard EN 50364;
EN 301 489-3 V.1.4.1 (02), and low voltage Directive 2006/95/CE: CEI60950-
1:2005 2nd edition.
USA information
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
Responsible Party:
Morpho,
Le Ponant de Paris, 27, rue Leblanc
F 75512 PARIS CEDEX 15
FRANCE.

6DOCUMENT SSE-0000077503-04 - MARCH 2011
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
Section 1: Introduction MorphoAccess® J Series – Installation Guide
NOTE This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful
interference to radio communications. However, there is no
guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following
measures:
• reorient or relocate the receiving antenna,
• increase the separation between the equipment and
receiver,
• connect the equipment into an outlet on a circuit different
from that to which the receiver is connected,
• consult the dealer or an experienced radio/TV technician
for help.
Shielded cables must be used with this unit to ensure
compliance with the Class B FCC limits.

SECTION 2
GENERAL
DESCRIPTION

DOCUMENT SSE-0000077503-04 - MARCH 2011 9
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
MorphoAccess® J Series – Installation Guide Section 2: General Description
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
1. Box opening
At the box opening, components shall be extracted from the white protection
casing as depicted in the pictures below.
The smoked front cover shall be removed from the terminal's body and kept
separate until the installation of the terminal is completed.

10 DOCUMENT SSE-0000077503-04 - MARCH 2011
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
Section 2: General Description MorphoAccess® J Series – Installation Guide
2. Components of the initial package
Figure 2.1: Package contents
1 One (1) Terminal’s body
2 One (1) Smoked front cover
3 One (1) Mounting Spacer
4 Two (2) block connectors (6 and 10 pins) for terminal's joint blocks
5 Four (4) M3X25 Screws (Terminal fixing)
6 Two (2) screw rubber caps (for the two M2.5X14)
7 Four (4) rawplugs (for Ø 3mm screws)
8 Two (2) M2.5X14 Torx screws (smoked front cover fixing)
9 One (1) L-shaped Torx key
1 2
3 9
4 5
7
6
8

DOCUMENT SSE-0000077503-04 - MARCH 2011 11
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
MorphoAccess® J Series – Installation Guide Section 2: General Description
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
SECTION 2: GENERAL
DESCRIPTION
3. Terminal’s front view description
Figure 2.2: MorphoAccess®J Series terminal front views
1 Terminal's body
2 Smoked front cover
3 Reset button
4 Contactless card reader
5 Anti-tamper switches
6 USB port (for configuration and settings)
7 Optical sensor
1
4
6
7
2
5
3

12 DOCUMENT SSE-0000077503-04 - MARCH 2011
MORPHO DOCUMENT - REPRODUCTION AND DISCLOSURE PROHIBITED
Section 2: General Description MorphoAccess® J Series – Installation Guide
4. Terminal’s rear view description
Figure 2.3: MorphoAccess®J Series terminal rear view
1 Smoked front cover fixation
2 Mounting holes
3 Anti-pulling switches
4 Mini USB port for Wi-Fi™ dongle connection
5 RJ45 (Power Over Ethernet)
6 Terminal blocks
1
3
5
6
2
4
2
2
2
Table of contents
Other Safran IP Access Controllers manuals