Salus VS10W User manual

4 in 1 Digital Thermostat Control
Models: VS10W and VS10B
INSTALLER / USER MANUAL
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0

02 VS10W and VS10B Installer Manual
Contents
1 x Installer / User manual VS10W VS10BFixing screws
Contents
Box contents
Introduction
Product Compliance
System options overview
Installation
Parameter Settings
Error Codes
User Guide
Installers notes
Warranty
Box Contents
Icons used in this manual:
Safety
Important info
Your benet
For latest PDF installation guide please
go to www.salus-controls.com
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0

Product Compliance & Safety Information
INTRODUCTION
Thank you for purchasing
the SALUS 4 in 1 digital room thermostat
VS10. To maximise the features the
unit, it should be used with
the SALUS Wiring Centre KL10.
The unit can be congured to be a
Programmable Thermostat (PRT), Group Control
Thermostat, Group Thermostat or hot water
timer. The units can communicate with each
other (including VS05 Dial Thermostat) when
connected to the wiring centre and using the
communication connections. More information
can be found on pages 9 and 10.
Product Compliance
This product is CE compliant and meets the
following EC Directives Electro-Magnetic
Compatibility directive 2004/108/EC
Low voltage Directive 2006/95/EC
Safety Information
Use in accordance with the regulations
The SALUSVS10 is to be used for
for room control of heating and hot water
systems inside the house.
SALUS Wiring Centre KL10
We hope you enjoy this product...
VS10W and VS10B Installer Manual 03
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0

Product Compliance & Safety Information
Sources of danger
The thermostat must be disconnected from mains supply
before removing the cover.
Emergency
Switch o the voltage to the individual thermostat wring
centre or complete system.
Installer parameter settings
The SALUS VS10 is equipped with installer
parameter section (see page 40) this must only
be entered by the installer or competent
person. Changing these parameters can have a
serious eect on your heating system
For the installer
Please enter any parameter changes in the
installer notes section (pages 72 - 74)
230V AC
04 VS10W and VS10B Installer Manual
These instructions are applicable to the SALUS model
stated on the front cover of this manual only.
Warning
This product must be tted by a competent person, and
installation must comply with the guidance, standards
and regulations applicable to the city, country or state
where the product is installed. Failure to comply with the
requirements of the relevant guidance, standards and
regulations could lead to injury, death or prosecution.
Warning
Always isolate the AC Mains supply before
installing or working on any components that
require 230 VAC 50Hz supply.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0

VS10W and VS10B Installer Manual 05
System Overview - Conguration Options
Programmable Room
Thermostat (PRT) The unit can be
congured to either
one of the following
1
UFH Manifold
Wiring Centre
Radiator
Boiler
Hot Water
Group Control
Thermostat
2
Group
Thermostat
3
Timer
4
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0

System Overview - Conguration Options
06 VS10W and VS10B Installer Manual
Programmable Room Thermostat (PRT)
When congured for PRT (see page 31) it mainly works by itself and allows the user to have separateTime and
Temperature control of each zone on the wiring centre. Features likeVacation , Party frost mode have to set on
each individual thermostat. The PRT can be congured for global Heat/Cool system changeover if your system
supports this.This is achieved from a switched input from the wiring centre (see note 6 from the wiring center
installation guide). Communication Connection (see page 13) is required to use heat/cool changeover function
Group Control Thermostat
When congured for a group control thermostat (see page 33) this allows central control of up to 7 group
thermostats see below, there can be a maximum of 2 groups per 8 zone wiring centre. Permanent temperature
override, Holiday, Party, Frost modes, can be selected centrally from the Group ControlThermostat. Holiday will
also be applied to a timer if applicable. Communication connections (see page 13) are required for grouping
the group thermostats. Thermostats can be also globally changed from heating to cooling thermostats if you
system supports this by using the switched input connection on the WC (see note 6 from the wiring center
installation guide) along with the communications connections mentioned above
Group Thermostat
When congured for Group thermostat (see page 36) and in group mode the group thermostat will follow the
time schedule and any override modes of the group thermostat. The Group thermostat can have its own
programd temperatures, manual override and also be removed from the group temporarily or permanently.
Communication connections required (see page 13).
Timer
When congured to timer (see pages 32 & 34) the unit will operate as a timer with no temp control.This can be
used for example hot water control.The timer will also follow Holiday mode from the group control thermostat
if applicable, communication connections required for this group function.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0

System Overview - Cables
Power and Switching Cable – used to
power thermostats and drive output
Grouping and Communication cable
Communication cable can be used when units are used as individual PRT's for heat/cool
changeover. Please refer to page 13 and note 5 on the wiring centre installation guide.
While the thermostats can function as stand alone
Programmable or Timer’s, Installing this Optional inexpensive
Communication Cable allows the thermostats to communicate
with each other. This allows the thermostat to assume
convenient remote control of groups of thermostats. Bringing
central control of features such asTime control, Holiday & Party
functions as well as frost control.The individual group members
can leave or re-enter group control at the push of a button
Cable size 1.5mm 3 core for L,N,SL and 0.5mm twin for the communication.
VS10W and VS10B Installer Manual 07
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0

System Overview - Options
Option 1 - Page 09
Option 2 - Page 10
Option 3 - Page 10
The systems below although not exhaustive show the main options.The
maximum number of groups per KL10 wiring centre is two. The group
selection communication cable must correspond to the group terminals
on the KL10 WC. Please refer to note 5 on the KL10 installation guide.
Group 1 Group 2
Group 1 Group 2
All Digital Variants can be
congured from VS10. Groups
must have a group control
thermostat. 1 or 2 Groups can be
used per wiring centre. HWTimer
can be stand alone or part of a
group. If using HWTimer as part
of a group it must be in group 1.
08 VS10W and VS10B Installer Manual
Option 2 - Unit is congured as a Group Control Thermostat used to control a group(s) of Dial Stat(s)
Option 3 - Unit is congured as a Group Control Thermostat used to control a group(s) of Digital Stat(s) congured as group thermostats.
Option 1 - Unit is congured as individual PRT.
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0

System Overview - Grouping and Communication
FUNCTION PRT USING COMMUNICATION
CONNECTION - PRT
Individual Room Control 44
Individual Holiday Function 44
Individual Party Function 44
Individual Heating Program 44
Individual Frost Function 44
Group Holiday including HW 66
Group Party 66
Group Heating Program 66
Group Permanent Override 66
Group Temporary Override 66
Heat/Cool changeover 64
Note:The communication connection is only used for heat/cool changeover when using
units congured to PRT’s and using the relevant connection on the KL10Wiring Centre.
Please refer to note 6 on Wiring Centre installation guide.
Option 1 - Page 31
VS10W and VS10B Installer Manual 09
SYSTEM OVERVIEW
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0

System Overview - Grouping and Communication
FUNCTION PRT USING COMMUNICATION
CONNECTION - GROUP CONTROL
Individual Room Control 44
Individual Holiday Function 44
Individual Party Function 44
Individual Heating Program 44
Individual Frost Function 44
Group Holiday including HW 64
Group Party 64
Group Heating Program 64
Group Permanent Override 64
Group Temporary Override 64
Heat/Cool changeover 64
Note HW timer will only use HOLIDAY function when the communication connection
is used. Also the HW timer must be connected to GROUP 1 communication terminals
on wiring centre. See note 8 onWiring Centre installation guide.
Option 2 - Page 33 Option 3 - Page 35
10 VS10W and VS10B Installer Manual
iT600 VS10W - VS10B Installer - User Manual 022.qxd_Layout 1 07.07.2014 0
This manual suits for next models
1
Table of contents
Other Salus Temperature Controllers manuals
Popular Temperature Controllers manuals by other brands

SMC Networks
SMC Networks Thermo-con INR-244-639 Operation manual

eltherm
eltherm Ex-TC It Series operating instructions

Omron
Omron C200H-TV Series Operation manual

industrie technik
industrie technik CA1 instructions

KRAL
KRAL EET 32 operating instructions

dixell