Troubleshooting
The power cable to the ballast
box is not connected properly
• Power cable is defective
• There is no power to the outlet
• The breaker is not ON
• The PCB is damaged
Make sure the power cable is
connected
• Change the power cord
• Test the outlet to make sure
there is power by using another
electrical appliance.
• Make sure the breaker is ON
• Contact Sanuvox for a new PCB
The lamp or ballast where Led is
red is defective
• Connection problem between
the ballast and the PCB
Replace lamp or ballast
corresponding to the red LED
• Verify connection between
ballast and PCB
• Verify wires that send ballast
signal to PCB
• Verify wire connection of ballast
and lamps on the terminal block
Jump or contactor are defective
• Access door is open
• No signal on the PLC board or
jumper is not inserted properly
(Mode 3 only)
• Fans are not working
Verify that jumper and contactor
are working
• Make sure access door is closed
tightly
• Connect 24 VDC to « PLC » (Mode
3 only)
• Insert the jumper in « BP »
position for automatic start
up(Mode 3 only)
• Make sure the fans are not
obstructed or replace them
flashing red/green
Lamp where the LED is flashing
has been on for more than 2
years.
Change lamp and reset counter
by pressing the button on the PCB
for 5 seconds
Note : Counter will be reset for ALL
lamps
Access door is open
• No signal on the PLC or the
jumper is not well inserted
(Mode 3 only)
• Fans are not working
• No Power to the ballast box
Make sure access door is closed
tightly
• Connect a 24 VDC on the « PLC »
(Mode 3 only)
• Insert the jumper in « BP »
position for automatic start
up(Mode 3 only)
• Make sure the fans are not
obstructed or replace them
• See LEDs are not (Go to #1)