2 AQUA S SATEL
The AQUA S detector detects motion in the protected area. This manual applies to the
detector with electronics version 4.2.
1. Features
•Motion detection with passive infrared sensor (PIR).
•Selectable detection sensitivity.
•Digital motion detection algorithm.
•Digital temperature compensation.
•Wide-angle lens.
•Ability to replace the lens with a curtain or long-range one.
•Built-in end-of-line resistors (2EOL: 2 x 1.1 k).
•LED indicator.
•Supervision of supply voltage.
•Tamper protection against enclosure opening.
•Adjustable mounting bracket included.
2. Specifications
Power supply ..............................................................................12...24 VAC/DC -10% / +15%
Standby current consumption
AC power..............................................................................................................11.5 mA
DC power.................................................................................................................. 5 mA
Maximum current consumption
AC power..............................................................................................................12.5 mA
DC power.................................................................................................................. 6 mA
EOL resistors.............................................................................................................2 x 1.1 k
Outputs
alarm (NC relay, resistive load) .........................................................40 mA / 27 VAC/DC
tamper (NC).....................................................................................100 mA / 27 VAC/DC
Relay contact resistance....................................................................................................26 Ω
Alarm signaling period...........................................................................................................2 s
Detectable speed......................................................................................................0.3...3 m/s
Warm-up period..................................................................................................................30 s
Recommended installation height.....................................................................................2.4 m
Coverage area (installation at 2.4 m, EWA lens) ..........................................15 m x 16 m, 108°
Complied with standards...............................................EN 50130-5, EN 50131-1, EN 50130-4
Environmental class according to EN 50130-5 ........................................................................II
Operating temperature range..................................................................................-10...+55 °C
Maximum humidity..........................................................................................................93