2 GREY • GREY Plus SATEL
Anti-mask feature
Detection by the microwave sensor of an object moving at a distance of 10-20 centimeters from the detector is
interpreted as an attempt to mask the detector and results in activation of anti-masking relay for two seconds.
Objects permeable to microwaves, but isolating the infrared radiation are not detected by the anti-mask feature.
Supervision features
In the event of the voltage drop below 9 V (± 5%) for more than 2 seconds or the signal path failure, the detector
will signal a trouble. The trouble is indicated by the activation of alarm relay and the steady red light of LED
indicator. The trouble signaling will continue as long as the trouble persists.
Remote LED enable/disable
The LED can be enabled/disabled remotely when the jumper is placed across the LED pins in OFF position.
The LED terminal is provided to allow remote LED enable/disable. The LED is enabled, when the terminal is
connected to the common ground, and disabled, when the terminal is disconnected from the common ground.
You can connect to the LED terminal an OC type control panel output programmed e.g. as the
S
ERVICE MODE
STATUS
,
BI
SWITCH
or
Z
ONE TEST STATUS
.
Alarm memory
If the LED is enabled, the detector can signal the alarm memory. The MEM terminal is provided to allow the
alarm memory enable/disable. The alarm memory is enabled, when the terminal is connected to the common
ground. The alarm memory is disabled, when the terminal is disconnected from the common ground. If the
alarm memory is enabled and an alarm occurs, the LED will start blinking red. Indication of the alarm memory
will continue until the alarm memory is enabled again (the MEM terminal is connected to the common ground).
Disabling the alarm memory will not stop the alarm memory indication. You can connect to the MEM terminal an
OC type control panel output programmed e.g. as the
A
RMED STATUS
.
4. Electronics board
microwave sensor.
terminals:
NC - alarm output (NC relay);
TMP - tamper output (NC);
AM - anti-masking output (NC relay) [GREY
Plus];
MEM - alarm memory control;
LED - remote LED control;
COM - common ground;
12V - power input.
bi-color LED to indicate:
– alarm – the LED lights red for 2 seconds;
– alarm memory – the LED is blinking red;
– motion detected by one of the sensors – the LED
lights green for 2 seconds;
– trouble – the LED lights red;
– warm-up – the LED is blinking alternately red and green.
dual element pyrosensor. Do not touch the pyroelectric sensor, so as not to soil it.
tamper switch.
detector configuration pins:
PET - enable/disable the pet immunity option. The option is enabled
when the jumper is set in ON position (Fig. 2).
LED - enable/disable the LED indicator. The LED is enabled, when
the jumper is set in ON position (Fig. 2) – the remote LED
enable/disable is not available then.
fixing screw hole.
potentiometer for adjustment of PIR sensor sensitivity.