A. GREEN MASTER SWITCH PUSH
BUTTON
Located in the front of the machine it’s used to
switchON andOFF theunit bypushing itsgreen
push button. When ON, its green light is ON as
well.
B. RED ALARM/RE-SET PUSH BUTTON
Located in the front of the machine (just beside
theMasterSwitch) itworks inconjuctionwiththe
PC Board and it’s activated when:
• Consensing temperature is higher then 70°C
(aircooledversion)-ONsteadywithmachine
in OFF mode
• Consensing temperature is higher then 60°C
(water cooled version) - ON steady with
machine in OFF mode
• Condenser sensor out of order - Blinking
twiceandrepeatwithmachineinOFFmode
• Condenser air filter need to be cleaned - ON
steady with machine in ON mode
• Water system need to be cleaned - Slow
blinking with machine in ON mode.
On the first two cases it’s possible to Re-Set the
operation of the machine pushing and hold the
Red Alarm Re-Set Button by 5" till the Red Light
is OFF.
On the third case, it’s necessary first to replace
the condenser sensor then, push and hold for 5"
the Red Re-Set Button.
C. EVAPORATOR TEMPERATURE
SENSOR
The evaporator sensor probe is inserted into its
tube well, which is welded on the evaporator
outlet line, it detects the temperature of the
refrigerant on the way out from the evaporator
and signals it by suppying a low voltage current
flow to the P.C. Board Micro-Processor.
According to the current received, the micro-
processor let the ice maker to continue its
operations. In case the evaporating temperatu-
re, after 10 minutes from the unit start-up, does
not go below -1°C (30°F) due to shortage of
refrigerant in the system the evaporator sensor
signal reaching the microprocessor is such to
stop immediately the unit operation (drive motor
keepsonworkingby3'delaythenstops),withthe
5th Warning YELLOW LED that blinks.
NOTE.ThemachinewillremaininOFFmode
for one hour then it will restart automatically.
In case the unit trips OFF again in alarm for
3timesin3hours,themachineSHUTS OFF
DEFINITIVELY.
Torestarttheunitaftertheshutoffcausedby
the hi evaporating temperature, it is neces-
sary to switch OFF and ON the power line
main disconnect Switch.
COMPONENTS DESCRIPTION D. WATER LEVEL SENSOR
Thissensorsystemconsistoftwosmallstainless
steelrods vertically fittedonthe inner face ofthe
reservoir cover and electrically connected to the
low voltage circuit of the P.C. Board.
When the cover of the reservoir is positioned in
its place the tips of both the rods dip into the
reservoir water and detects and signals its
presence by making use of its electrical
resistance.
NOTE. In the event of shortage of water in
thereservoiror,incasethewaterusedistoo
soft (de-mineralized) to cause greater
resistence to the current flow (conductivity
lowerthan30
µ
S)thissensorsystemcauses
the shutoff of the machine (drive motor
keeps on working by 3' delay then stops), to
protect it from running with an interrupted or
inadequatewatersupply.Inthissituationthe
YELLOW LED will glow to warn of the
machine shutoff and the reason why.
E. CONDENSER TEMPERATURE SENSOR
The condenser temperature sensor probe,
located within the condenser fins (air cooled
version) or in contact with the tube coil (water
cooledversion) detectsthe condensertempera-
ture variations and signals them by supplying
current, at low voltage, to the P.C. BOARD.
In case the condenser temperature sensor
detects a temperature at the condenser lower
than +1°C (33°F) that signify that the ambient
temperature is at the same value, therefore it is
too low for the correct unit operation, the sensor
signalstothemicroprocessortostopimmediately
or to do not start the unit operations up to the
momentthattheambient temperaturewillriseto
more acceptables conditions (5°C).
In the air cooled versions, in relation to the
differentcurrentreceived,themicroprocessorof
theP.C.BOARDsupplies, throughaTRIAC,the
power at high voltage to the fan motor so that it
can cool the condenser and reduce its temperature.
In the event the condenser temperature rises
andreaches70°C or60°Cthecurrentarrivingto
the micro processor is such to cause an immediate
and total stop of the machine operation (drive
motor keeps on working by 3' delay then stops).
NOTE. The machine will remain in OFF
modeforonehourthenitwillrestartautoma-
tically. In case the unit trips OFF again in
alarm for 3 times in 3 hours, the machine
SHUTS OFF DEFINITIVELY.
Torestarttheunitaftertheshutoffcausedby
thehicondensertemperature,it isnecessary
to switch OFF and ON the power line main
disconnect Switch.