manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Seitron
  6. •
  7. Measuring Instrument
  8. •
  9. Seitron CHEMIST 100 BE GREEN User manual

Seitron CHEMIST 100 BE GREEN User manual

Other Seitron Measuring Instrument manuals

Seitron NOVO User guide

Seitron

Seitron NOVO User guide

Seitron PRESSOTEST 300 User manual

Seitron

Seitron PRESSOTEST 300 User manual

Seitron CHEMIST 400 User manual

Seitron

Seitron CHEMIST 400 User manual

Seitron PRESSOTEST 200 User manual

Seitron

Seitron PRESSOTEST 200 User manual

Seitron CHEMIST 200 User manual

Seitron

Seitron CHEMIST 200 User manual

Seitron PRESSOTEST 200 User manual

Seitron

Seitron PRESSOTEST 200 User manual

Seitron CASPER User manual

Seitron

Seitron CASPER User manual

Seitron GAS T ONE User guide

Seitron

Seitron GAS T ONE User guide

Seitron NOVO User guide

Seitron

Seitron NOVO User guide

Seitron CHEMIST 900 RACK User guide

Seitron

Seitron CHEMIST 900 RACK User guide

Seitron BE COOL V1 SMART User manual

Seitron

Seitron BE COOL V1 SMART User manual

Seitron S500 User guide

Seitron

Seitron S500 User guide

Seitron CHEMIST 600 User manual

Seitron

Seitron CHEMIST 600 User manual

Seitron BE COOL M4 User manual

Seitron

Seitron BE COOL M4 User manual

Seitron N-VO User manual

Seitron

Seitron N-VO User manual

Seitron PRESSOTEST 100 User manual

Seitron

Seitron PRESSOTEST 100 User manual

Seitron CHEMIST 500 User manual

Seitron

Seitron CHEMIST 500 User manual

Seitron PORVAL0112 Instruction Manual

Seitron

Seitron PORVAL0112 Instruction Manual

Seitron CHEMIST 900 RACK User manual

Seitron

Seitron CHEMIST 900 RACK User manual

Seitron PRESSOTEST 200 User manual

Seitron

Seitron PRESSOTEST 200 User manual

Seitron CHEMIST 600 BE GREEN User guide

Seitron

Seitron CHEMIST 600 BE GREEN User guide

Seitron PRESSOTEST 300 User manual

Seitron

Seitron PRESSOTEST 300 User manual

Seitron S1500 User guide

Seitron

Seitron S1500 User guide

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

K100000000SE 030345 140618
FEATURES:
 Combustion analysis in Auto or Manual Mode
 Calculation of stack heat loss and efficiency
 CO environment measurement
 Measuring differential pressure
 Draft measurement
 Pressure measurement in the gas supply pipe
 Generation and display of a QR Code for downloading the data of the
analyses
 Possibility to print on ticket the analyses and the performed measures
with a Bluetooth® printer (optional)
The magnets in the back of the instrument can damage
credit cards, hard drives, mechanical watches,
pacemakers, defibrillators and other devices proven
sensitive to magnetic fields.
It is recommended to keep the instrument at a distance
of at least 10” away from any of these devices.
KEYBOARD FUNCTIONS CONTEXT KEYS
ESC
>
>
KEYS FUNCTION
Activate the context keys shown
on the display.
Turns on and off the instrument.
- If pressed briefly, accesses the
instrument menu.
-
If pressed for at least 2 seconds,
turns off the instrument.
Exits the current screen.
Confirm settings.
Select and/or Modify.
OK
>
>
>
>
CONTEXT
KEY
FUNCTION
Saves the data in the instrument
memory.
Display the printing options screen
and consequently execute it.
From the main screen erase the
memory.
From every measure or analysis
screen, erase the single data.
Proceed with the combustion
analysis.
Repeat the autozero phase.
Save
Print
Delete
Keep
Repeat
11/12/17 10:00
MENU
►Measurements
Memory
Configuration
Diagnostic
Info service
OK
11/12/17 10:00
MEASUREMENTS
►Comb. analysis
Draft
CO air
Pressure
Tightness test
11/12/17 10:00
AN. SETTINGS
►Mode AUTO
Fuel
Natural gas
Interval 1 s
Memory 1/5
Start
OK
Via del Commercio, 9/11 36065 - MUSSOLENTE (VI)
+39.(0)424.567842 - +39.(0)424.567849
[email protected] - www.seitron.it
11/12/17 10:00
ANALYSIS [1/3]
Tf 190.1 C
Ta 15.4 C
O2 4.2 %
CO 23 ppm
CO2 2.9 %
COr ---- p
Pause 1/3 1
Automatically
saves the first
sample when the
set interval
expires, and so on
until the third
sample.
11/12/17 10:00
AVERAGE [1/3]
Tf 190.1 C
Ta 15.4 C
O2 4.2 %
CO 23 ppm
CO2 2.9 %
COr ---- p
Print
Start Print
Scan the QR code using the
Seitron APP “SMARTFLUE
LITE MOBILE”, to download
the acquired data related to
the average analyses and the
additional measures, if
performed.
11/12/17 10:00
PRINT
Average
►Copy number 1
Printer OFF
QR Code ON
Pairing BT
Print
Print
- Before starting the combustion analysis, select the utilized fuel.
- If it is desired to print the ticket of the average analyses and the additional measures
enable the printer in the “PRINT” menu.
- If it is desired to print the complete analysis and the performed measures, it will be
necessary to enter the memory menu “MEMORY”, select the related memory number
and push the “PRINT” interactive function button.
- To download the data of the single performed analyses, it’s necessary to enter the “MEMORY”
menu, select the memory number used to save the analyses and the measures and select one at a
time the single rows.
Seitron respects the nature and the environment, therefore provides this quick user
guide of the CHEMIST 100 BE GREEN analyzer.
However the complete manual for use and maintenance of the CHEMIST 100 BE GREEN
is already available at the internet site www.seitron.com.
Respect your environment: think before printing the full manual on paper.
AACKP01
Keep
pressed
for a few
seconds
AAAL05
Menu→Memory
11/12/17 10:00
AUTOZERO
60
Primary air
acquisition
CHEMIST 100
BE GREEN
N.S.:0
Fw:1.00-EVAL03
11/12/17 10:00
MEMORY
►Memory 1/5
Status Full
Time 09:50
Date 11/12/17
Select
OK
>
>
OK
11/12/17 10:00
MEMORY
►Memory 1/5
Status Full
Time 09:50
Date 11/12/17
Select
Select
Procedure to set the
memory number
where it will be
possible to store
the analyses/
measures
Procedure to
visualize the
content of a
memory
Menu→Measurements→Draft Menu→Measurements→CO air
11/12/17 10:00
DRAFT
Inlet P-
Draft --- P
►Zero
Save Print
Procedure to perform the draft measurement:
-
Perform the Zero phase of the pressure sensor:
Select “Zero” => push .
- Connect the pressure output of the probe with
the P- inlet of the instrument.
- Insert the tip of the smoke probe in the stack.
OK
11/12/17 10:00
CO AIR
CO 1412 P
CO Max 1413 P
Save Print
WARNING
It is compulsory to perform the Zero phase in clean
air, so that the environment CO measurement
results correct. It is advisable to turn on the
instrument and wait for the Zero phase completion
outside the area where the test is being performed.
 Before switching on the instrument, insert the Tc-K connector of the smoke probe to the
instrument for primary air acquisition.
 Perform the Zero phase of the instrument in fresh clean air.
 When the Zero phase is over, push the button related to the interactive function “Keep”
to store the acquired temperature value.
11/12/17 10:00
AUTOZERO
Primary air
acquisition
T: 21.5°C
Keep Repeat

Be sure all connections are tight to
assure accurate sampling.

When conducting measurements, the
water trap/filter assembly MUST be in
a VERTICAL position to prevent
damage from moisture & particles to
sensors.

When testing is completed, always drain the
water trap.
AASF--A
11/12/17 10:00
PRINT
►Copy number 1
Printer IR
Mode fast
QR Code ON
Pairing BT
Ticket print
Set the parameter “Copy number”
Set the parameter “printer” on BT or IR
Only if the printer is set on IR:
Set the parameter “Mode” on fast or slow
Only if the printer is set on BT:
Associate the instrument to the BT printer through
the parameter Pairing BT (only for the first time)
QR code generation
Set the parameter “QR code” on ON
Menu→Configuration→Print