Selecon 5.5-13 User manual

REGISTER THIS PRODUCT WITH PHILIPS SELECON: www.seleconlight.com/warrantyreg
Version 3.1: September 2007 © 2007 Selecon New Zealand Limited All Rights Reserved
OPERATION MANUAL
PACIFIC VERY NARROW
ZOOMSPOT MODELS:
5.5-13and 7-19
For Pacific MSR, CDM, 80V Power System please refer to the additional instruction sheets as well.
For Pacific 12-28, 14-35, 23-50, 45-75 Zoomspots and Fixed Beam models, please refer to the main
instruction manuals.
THANK YOU FOR PURCHASING A SELECON PACIFIC LUMINAIRE. WE
HAVE DESIGNED THIS LUMINAIRE TO PROVIDE YOU WITH A
SUPERIOR FITTING IN PERFORMANCE, DESIGN & ENGINEERING. WE
ARE CONFIDENT THAT IT WILL PERFORM TO YOUR EXPECTATIONS
FOR MANY YEARS TO COME.
Caution!
Installation is entirely at your risk. Read this manual from cover to cover before attempting
installation. Do not attempt installation unless you are suitably qualified. If you do not
understand a point in this manual, don’t guess. Don’t take short cuts. If in doubt, stop!
Contact Philips Selecon or one of its authorised distributors for advice. Don’t be afraid to
ask for help.
IMPORTANT NOTE: Before discarding the packaging ensure you have the suspension bolt set,
colour frame, safety chain for the attachment between the lamphouse and lens tube and/or lamp.

Pacific Operation Manual 2
Version 4 October 2010
Important!
Read this manual from cover to cover before attempting to install, operate or maintain the luminaire
to which it relates. It contains important installation, operating, maintenance and safety procedures.
The customer must strictly comply with them.
Along with such procedures mentioned in this document, the customer should also observe such
other procedures generally applicable to lighting equipment.
Follow the instructions in this manual carefully. Philips Selecon accepts no responsibility if the
customer fails to do so.
For each customer, operating conditions will vary, sometimes greatly. Such variations may affect
the luminaire’s performance. Philips Selecon has no control over the customer’s unique operating
environment. Hence, Philips Selecon makes no representations or warranties concerning the
luminaire’s performance under the customer’s actual operating conditions. All operating parameters
must be validated for each customer application by the customer’s technical experts.
If the customer does not follow the installation, operating, maintenance and safety procedures in this
manual, as well as those generally applicable to lighting equipment, the luminaire may not perform
as expected. More seriously, it may cause property damage, personal injury or other losses.
Philips Selecon accepts no liability for direct, indirect, incidental, special, or consequential damages
resulting from the customer’s failure to follow the installation, operating, maintenance and safety
procedures in this manual or those generally applicable to lighting equipment. The foregoing
limitation extends to damages for personal injury, property damage, loss of operations, loss of
profits, loss of product or loss of time, whether incurred by the customer, the customer’s employees
or a third party.
Philips Selecon used all due care in preparing this manual. However, Philips Selecon accepts no
liability for errors or omissions. Philips Selecon reserves the right to change the specifications of its
luminaires, or the information in this manual, without necessarily giving its customers notice thereof.
Installation, operation and maintenance are entirely at the customer’s risk.
Philips Selecon luminaires should be installed, operated and maintained by suitably qualified
personnel. Such personnel should have previous experience with lighting equipment as well as
general electrical experience.
This manual is intended to provide general guidance to such suitably qualified personnel. For
specific guidance and technical support, contact Philips Selecon or its authorised representative.
Information in this manual shall not be deemed a warranty, representation or guarantee concerning
a luminaires’ suitability or fitness for a specific purpose.
Subject to the right to use its luminaires, Philips Selecon does not convey any right, title or
interest in its intellectual property, including, without limitation, its patents, copyrights and
know-how. If you would like further assistance contact your local Philips Selecon dealer or
Philips Selecon.

Pacific Operation Manual 3
Version 4 October 2010
Lamp module GKV 600/800W Lamp Module 80V 1200W Lamp Module BP1000W Lamp Module CDM 150
…………..Blue Handle Red Handle Black Handle
Please read this information carefully to ensure that you are fully conversant with its
operation.
Subject to the right to use its luminaires, Philips Selecon does not convey any right, title or interest in its
intellectual property, including, without limitation, its patents, copyrights and know-how. If you would like
further assistance contact your local Philips Selecon dealer or Philips Selecon. ................................................2
Safety Warnings ...................................................................................................................................................4
Operating your luminaire for the first time ............................................................................................................4
Centering the lamp ...............................................................................................................................................5
Centre the lamp in the middle of the beam if necessary, by adjusting the three levelling screws. Optimising the
output....................................................................................................................................................................6
Lamps...................................................................................................................................................................6
Mounting your luminaire .......................................................................................................................................7
To mount on a theatre standard scaffold pipe......................................................................................................7
To mount on a telescopic stand............................................................................................................................7
Adjustable Yoke....................................................................................................................................................7
Operating your luminaire ......................................................................................................................................8
Pan and Tilt Adjustment........................................................................................................................................8
Focusing Pacific Zoomspot models......................................................................................................................8
Shutter System .....................................................................................................................................................8
Accessory mounting positions..............................................................................................................................8
Colour Filter Life ...................................................................................................................................................9
Safe Practice ......................................................................................................................................................10
Rigging Check-list...............................................................................................................................................10
Maintenance .......................................................................................................................................................10
Safety..................................................................................................................................................................11
LIMITED WARRANTY........................................................................................................................................11
Accessories and codes.......................................................................................................................................12

Pacific Operation Manual 4
Version 4 October 2010
Safety Warnings
1.0m
D
= 90o
Not for residential use.
CAUTION: Hot Surfaces, Avoid contact by persons or materials.
The Pacific has some hot surfaces. Be careful to avoid burns. Take care with the lamp
house and Heat sink. We suggest the use of leather gloves when focusing these
luminaires.
SAFETY –Mains Power Isolation
The Pacific range is fitted with a micro-switch that automatically disconnects the mains
power when the lamp holder is removed. However, it is also recommended that the
luminaire should always be electrically isolated from mains power before re-lamping,
cleaning or servicing.
CAUTION: Risk of fire - Use with max 1000 watt lamp.
CAUTION: For the 575W MSR model Pacific, use only a high-pressure lamp of the proper
size and type in this lamp system.
These luminaires are not suitable for mounting on a normally flammable surface.
These luminaires are not suitable for outdoor use. They are rated at IP00.
The luminaire should be at least 1.0 metre away from the nearest object it is lighting.
The Pacific range can be operated only through a range of angles 90either side of
horizontal.
Operating your luminaire for the first time
When first opening the packing box for your luminaire,
please note that the lamp holder module is in a separate
box. Before inserting a lamp into the module, we suggest
that you practice the motion of removing and inserting the
lamp holder module from the lamphouse.
Loosen the thumb-screw at the front of the lamp
holder module by about 5mm. Holding the lamp
holder module by the Handle, slide it forward until
both the rear lip and the front 'T' of the lamp holder
module clear their home positions. Reverse this
action to replace the lamp holder and then tighten
the thumb-screw to lock the lamp holder module
into position.
1
2
Rear Lip Front'T'

Pacific Operation Manual 5
Version 4 October 2010
For ease of shipping, the Pacific VNZ is supplied
with the lamp house removed. Attach the lamp
house by sliding it into the guides on the rear of
the lens tube, and then fastening the lamp house
locking clamp. Attach the supplied safety chain
between the luminaire anchor point, and the rear
anchor point of the lens tube (see below).
To enable the balancing of the Pacific VNZ, the
yoke is mounted on the lens tube. The balancing of the Pacific VNZ is best done when the luminaire is being
unpacked for use. Please refer to page 7 for more details. The lamp house has no yoke fitted. A yoke can be
fitted if the lamp house is to be used with other lens barrels. Please contact your Philips Selecon distributor for
order codes.
Familiarise yourself with the way the shutter assembly can be rotated by loosening the shutter assembly knob
on the rear of the tube, and turning the assembly. Note how the colour frames are locked into the front of the
lens tube with the colour frame locking clip and plunger.
The Pacific VNZ provides for mounting 2 gobo holders. Practice inserting them into both the front and rear
position as it is easier to familiarise yourself with something new while it is on the ground rather than up in the
air.
Lamp Replacement & adjustment:
Isolate electrically before re-lamping the luminaire. Also be aware that the lamp or luminaire may still
be hot, so exercise necessary caution to avoid burns.
To ensure optimum performance from your Pacific luminaire, follow the steps below:
Centering the lamp
1 Remove the lamp holder module as described above.
2 Set the level of the metal cup holding the lamp base. The metal cup has a line around it. This level is
factory set to the optimum position, and the luminaire output is then confirmed with test equipment.
The optimum position has the line level with the edge of the module.
First level the cup with the edge of the module by adjusting the three levelling screws. Then set to the
correct height as detailed above.
3 Remove the old lamp. Align the pins of the new lamp to the correct holes and push the lamp firmly
home. Do not touch the quartz envelope of the lamp with your fingers - use the plastic or paper
sheath supplied to insert the lamp.
4 Carefully replace the lamp holder module and tighten the thumbscrew to lock it into position.
Reconnect the luminaire to the power supply.
5 Turn on the luminaire to approximately 30%. This makes the peak easier to see, and reduces the
stress on the filament. Set the beam angle to its widest with a sharp edge.
6 Centre the lamp in the middle of the beam if necessary, by adjusting the three levelling screws.
This manual suits for next models
1
Table of contents
Other Selecon Lighting Equipment manuals

Selecon
Selecon PLPROFILE1 MKII User manual

Selecon
Selecon Pacific 19PACLMCOV User manual

Selecon
Selecon MaxAV User manual

Selecon
Selecon High Performance Fresnel User manual

Selecon
Selecon ACCLAIM FRESNEL User manual

Selecon
Selecon PLPROFILE4 MKII User manual

Selecon
Selecon Rama Fresnel Series User manual

Selecon
Selecon Pacific Dowser User manual