This manual concerns the operation of the mechanical dimming system
only. For instructions on the operation of the Pacific luminaire fixture,
please also refer to the additional instruction sheet.
THANK YOU FOR PURCHASING A SELECON PACIFIC LUMINAIRE ACCESSORY. WE HAVE
DESIGNED THIS LUMINAIRE ACCESSORY TO PROVIDE YOU WITH A SUPERIOR FITTING IN
PERFORMANCE, DESIGN & ENGINEERING. WE ARE CONFIDENT THAT IT WILL PERFORM TO
YOUR EXPECTATIONS FOR MANY YEARS TO COME.
Caution!
Installation is entirely at your risk. Read this manual from cover to cover before attempting
installation. Do not attempt installation unless you are suitably qualified. If you do not
understand a point in this manual, don’t guess. Don’t take short cuts. If in doubt, stop!
Contact Selecon or one of its authorised distributors for advice. Don’t be afraid to ask for help.

Pacific Dowser Manual 2
Version 5: January 2005 ©2005 Selecon New Zealand Limited All Rights Reserved 2
Important!
Read this manual from cover to cover before attempting to install, operate or maintain the luminaires
to which it relates. It contains important installation, operating, maintenance and safety procedures.
The customer must strictly comply with them.
Along with such procedures mentioned in this document, the customer should also observe such other
procedures generally applicable to lighting equipment.
Follow the instructions in this manual carefully. Selecon accepts no responsibility if the customer fails
to do so.
For each customer, operating conditions will vary, sometimes greatly. Such variations may affect the
luminaires’ performance. Selecon has no control over the customer’s unique operating environment.
Hence, Selecon makes no representations or warranties concerning the luminaires’ performance
under the customer’s actual operating conditions. All operating parameters must be validated for each
customer application by the customer’s technical experts.
If the customer does not follow the installation, operating, maintenance and safety procedures in this
manual, as well as those generally applicable to lighting equipment, the luminaire may not perform as
expected. More seriously, it may cause property damage, personal injury or other losses.
Selecon accepts no liability for direct, indirect, incidental, special, or consequential damages resulting
from the customer’s failure to follow the installation, operating, maintenance and safety procedures in
this manual or those generally applicable to lighting equipment. The foregoing limitation extends to
damages for personal injury, property damage, loss of operations, loss of profits, loss of product or
loss of time, whether incurred by the customer, the customer’s employees or a third party.
Selecon used all due care in preparing this manual. However, Selecon accepts no liability for errors or
omissions. Selecon reserves the right to change the specifications of its luminaires, or the information
in this manual, without necessarily giving its customers notice thereof.
Installation, operation and maintenance are entirely at the customer’s risk.
Selecon’s luminaires should be installed, operated and maintained by suitably qualified personnel.
Such personnel should have previous experience with lighting equipment as well as general electrical
experience.
This manual is intended to provide general guidance to such suitably qualified personnel. For specific
guidance and technical support, contact Selecon or its authorised representative.
Information in this manual shall not be deemed a warranty, representation or guarantee concerning a
luminaires’ suitability or fitness for a specific purpose.
Subject to the right to use its luminaires, Selecon does not convey any right, title or interest in its
intellectual property, including, without limitation, its patents, copyrights and know-how.

Pacific Dowser Manual 3
Version 5: January 2005 ©2005 Selecon New Zealand Limited All Rights Reserved 3
Contents
Safety Warnings ...................................................................................................................................... 4
Introduction.............................................................................................................................................. 4
Important Operational Notes ................................................................................................................... 5
Parts of the Dowser ............................................................................................................................. 5
Installation Warnings............................................................................................................................ 5
Performance Warning .......................................................................................................................... 5
Assembling the Dowser onto a Pacific ................................................................................................ 6
Powercon Connector ........................................................................................................................... 7
Dowser Control Panel.............................................................................................................................. 7
DMX Operation .................................................................................................................................... 7
DMX Address Setting........................................................................................................................... 7
Local Level Control .............................................................................................................................. 7
Display Setting ..................................................................................................................................... 8
Recommended DMX Distribution Layout.............................................................................................8
Operational Warning............................................................................................................................ 8
Operational Note.................................................................................................................................. 9
Power up Procedure ............................................................................................................................ 9
Important Note on Centering the Lamp ............................................................................................... 9
Care and Maintenance......................................................................................................................... 9
Fault Guide ........................................................................................................................................ 10
Check................................................................................................................................................. 10
Dimensions............................................................................................................................................ 10
Weights.................................................................................................................................................. 11
Lamps .................................................................................................................................................... 11
Safe Practice ......................................................................................................................................... 11
Safety..................................................................................................................................................... 11

Pacific Dowser Manual 4
Version 5: January 2005 ©2005 Selecon New Zealand Limited All Rights Reserved 4
Safety Warnings
= 90
o
Not for residential use.
CAUTION: Hot Surfaces, Avoid contact by persons or materials.
The Pacific has some hot surfaces. Be careful to avoid burns. Take care with the
Lamp house and Heat sink. We suggest the use of leather gloves when focusing
these luminaires.
SAFETY - Mains Power Isolation
The unit should always be electrically isolated from mains power before moving,
cleaning or servicing.
CAUTION: Risk of fire - Use with maximum 575W MSR lamp.
CAUTION: These luminaires are not suitable for mounting on a normally flammable
surface.
These luminaires are not suitable for outdoor use. They are rated at IP00.
The Pacific range can be operated only through a range of angles 90°either side of
horizontal.
Introduction
The Pacific Dowser is an accessory for the Pacific family of luminaires.
It is a mechanical dimming mechanism for discharge sources, such as the 575W MSR, 575W MSR
Hot Restrike, 250W Hot Restrike ST, and 150W CDM and 70W CDM Pacifics.
Through the use of this accessory, a smooth even fade is possible without compromising the
maximum output of the system.
The dowser is intended for use in theatrical applications and performs in a similar way to traditional
tungsten halogen light sources. The dowser is not intended for strobe type effects i.e. rapid sequential
off/on operation.

Pacific Dowser Manual 5
5
Version 5: January 2005 ©2004 Selecon New Zealand Limited All Rights Reserved
Important Operational Notes
Parts of the Dowser
Installation Warnings
•Do not operate the dowser from a dimmed mains power supply.
•Do not hang the unit upside down.
•Always use a safety chain with the unit. Attach one end of it to one of the safety chain anchor
points on the dowser and attach the other end around a secure independent anchor point.
•Prolonged use of the dowser with the arms closed and the light source on will result in damage to
the dowser, and is not covered under warranty.
Performance Warning
The Pacific Dowser is optimised to provide a visually smooth even fade for the following Pacific
models:
Pacific 5.5°-13° Zoomspot
Pacific 12°-28° Zoomspot
Pacific 14°-35° Zoomspot
Pacific 23°-50° Zoomspot
Pacific 45°-75° Zoomspot
Pacific 90° Fixed Beam
The optical performance when using the Pacific 20°,30°,40° or 50° Fixed Beam is outside the design
parameters of the dowser. It is not recommended for use with these models.
Table of contents
Other Selecon Lighting Equipment manuals

Selecon
Selecon MaxAV User manual

Selecon
Selecon Pacific 19PACLMCOV User manual

Selecon
Selecon ACCLAIM FRESNEL User manual

Selecon
Selecon Rama Fresnel Series User manual

Selecon
Selecon PLPROFILE4 MKII User manual

Selecon
Selecon High Performance Fresnel User manual

Selecon
Selecon 5.5-13 User manual

Selecon
Selecon PLPROFILE1 MKII User manual