SELVAS Healthcare ACCUNIQ BC720 User manual

English. 06/2021. V3.02
User Manual BC720

The device bears the CE label in accordance with the provisions of Medical Device Directive 93/42/EEC.
THE PERSONS RESPONSIBLE FOR PLACING DEVICES ON THE EC MARKET UNDER MDD 93/42/EEC
SELVAS Healthcare, Inc.
155, Sinseong-ro, Yuseong-gu, Daejeon, 34109 Republic of Korea
TEL: +82 42 879 3000, FAX: +82 42 864 4462
Obelis s.a.
Bd. Général Wahis, 53, B-1030, Brussels, Belgium

CONTENTS_3
CONTENTS
CONTENTS 3
INTRODUCTION 5
INTENDED USE .......................................................................... 5
WORD DEFINITIONS............................................................... 5
CLASSIFICATION AND COMPLIANCE ............................. 6
SAFETY PRECAUTIONS........................................................... 6
SAFETY SYMBOLS AND INFORMATION......................10
Guidance for Electromagnetic compatibility
(EMC)............................................................................................12
ABOUT BODY COMPOSITION 14
TERMS OF EACH PART AND FUNCTION16
Main Parts..................................................................................16
Options........................................................................................16
<Good point of using SM103 as an option>.18
<When using SM103>...............................................18
Appearance of the device..................................................19
Front Part ..........................................................................19
Term of each parts and its function..............................20
Display Operation Part ...............................................20
Body Part...........................................................................21
Base Part............................................................................22
Rear Part............................................................................23
INSTALLATION 24
Power Supply............................................................................24
Peripheral Device Installation ...........................................25
Connecting Computer ................................................25
Connecting Printer .......................................................26
Connecting Blood Pressure Monitor ...................26
Ultrasonic Height meter SM103............................27
SYSTEM SETUP 28
Entering SYSTEM SETUP .....................................................28
Menu in SYSTEM SETUP............................................28
Setup ............................................................................................29
Basic setting.....................................................................29
Data Management........................................................30
Printer .................................................................................31
Result Sheet.....................................................................31
Communication..............................................................32
Weight/Height................................................................32
Option Management...................................................33
Display................................................................................33
Customer center............................................................33
MEASURING AND ANALYZING 35
Precaution for measurement............................................35
Correct position to measure.............................................36
How to touch electrodes...........................................36
Measurement Posture.................................................37
Measurement............................................................................38
Basic analysis...................................................................38
Using Ultrasonic Height Meter ..............................42
Procedure using Blood Pressure Monitor.........43
RESULT INTERPRETATION 44
STORAGE & MAINTENANCE 49
ERROR & REPAIR 51

SELVAS Healthcare, Inc.
4_CONTENTS
Kinds of Error & Repair .......................................................51
Error occurrence & Repair .................................................52
AFTER SERVICE 54
AFTER SERVICE ........................................................................54
How to contact SELVAS Healthcare .....................54
PACKING AND TRANSPORT..............................................54
SPECIFICATION 56
WARRANTY 58

User Manual BC720
INTRODUCTION_5
INTRODUCTION
You are kindly requested to be familiar with these directions before using this product and always keep it
together with the product. In case you are not sure about any directions or problems arising while using
the product, please contact with SELVAS Healthcare or its local distributor where is purchased. We will
provide you with detailed instructions.
INTENDED USE
This device measures impedance by bioelectrical impedance analysis method and provides lots of
information using measured impedance and inputted personal data (height, age, gender, weight).
It shows body composition of MBF, LBM, SLM, SMM, TBW, protein mass, mineral mass, etc. and information
regarding BMI, PBF, BMR, abdominal analysis, Target to control, segmental analysis, Body composition
change, etc.
Intended application location is professional healthcare facility environments, not home healthcare
environment.
WORD DEFINITIONS
To ensure safe operation and long term performance stability, it is essential that you fully understand the
functions, operating and maintenance instructions by reading this manual before operating your unit.
Particular attention must be paid to all warnings, cautions and notes incorporated herein.
The following conventions are used throughout the manual to denote information of special emphasis.
Warning
“Warning”indicates important information about the presence of a hazard which may
cause severe personal injury, loss of substantial property, damage if the warning is
ignored.
Caution
“Caution”indicates important information about the presence of a hazard which may
cause minor personal injury or property damage if the caution is ignored.

SELVAS Healthcare, Inc.
6_INTRODUCTION
Note
“Notice”indicates important information in order to notify installation, operation or
maintenance of this device. "Notice" is important but not hazard-related. Hazard
warnings are not included here.
CLASSIFICATION AND COMPLIANCE
1) This device is classified as;
Class 1 type-BF against electric shock
Ordinary equipment without protection against ingress of water
Equipment not suitable for use in presence of a flammable anesthetic mixture by standard of IEC
60601-1:2005/A1:2012 (Basic safety and essential performance of Medical Electrical Equipment)
2) This device is complied with Class A for Noise-Emission, Level B for Noise-immunity, by standard of
IEC 60601-1-2:2014(Electromagnetic Compatibility Requirements).
SAFETY PRECAUTIONS
This device is designed and manufactured with consideration of the safety of the operator and subject
and also the reliability of the unit.
The following warnings, precautions and notes must be observed for safety;
Warning
During measurement of the body composition, a microcurrent of 180μA flows through
the body. Individuals who have any kind of implanted active medical devices, such as
pacemakers, should not use this equipment because the microcurrent can cause
malfunction in the implanted device.
Warning
To prevent fire hazard, use only a correctly wired (100-240VAC) outlet, and do not use a
MSO(Multiple Socket Outlet) that is not in compliance with IEC 60601-1.
Warning
To reduce the risk of electric shock or product damage, never plug-in or plug-out with
wet hands.

User Manual BC720
INTRODUCTION_7
Warning
Physically disabled persons should not attempt to take measurements alone, but
instead should have their caretakers assist them in using the device.
Caution
The unit must be operated only by, or under supervision of a qualified person with
SELVAS Healthcare or our distributors.
Caution
If you have experienced any trouble with the unit, switch it off immediately, and contact
SELVAS Healthcare or its authorized dealer for assistance.
Caution
If you plan to connect any device from other manufacturers electrically or mechanically
to the unit, contact SELVAS Healthcare or its authorized dealer for instructions before
doing so.
When you connect computer or other system to the unit (RS-232C), the attached
systems should be those certified by IEC 950 or equivalent standards for data
processing equipment.
Configurations shall comply with the system standard IEC 60601-1:2005/A1:2012.
Everybody who connects additional equipment to the signal input part or signal output
part configures a medical system by standard IEC 60601-1:2005/A1:2012.
If in doubt, consult the A/S department of local distributor.
Caution
Avoid the following environments for storage;
Where the ambient temperature falls below -25°C or exceeds 70°C.
Where the atmospheric pressure falls below 70kPa (700mbar) or exceeds 106kPa
(1060mbar).
Where the humidity is over 93% non-condensing.
Where the unit is exposed to spray or splashing water.
Where the unit is exposed to dust.
Where the unit is exposed to water vapor.
Where the unit is exposed to salty atmosphere.
Where the unit is exposed to explosive gas.
Where the unit is exposed to excessive shocks or vibrations.

SELVAS Healthcare, Inc.
8_INTRODUCTION
Where the angle of inclination of mounting surface exceeds 10 degrees.
Where the unit is exposed to direct sunlight.
Caution
This device needs special precautions regarding EMC and needs to be installed and put
into service according to the EMC information provided in the ACCOMPANYING
DOCUMENTS.
Caution
Cross contamination is possible because this equipment is used with bare hands and
feet. Refer to the cleaning and disinfecting methods in this manual.
Caution
Measurements may be impaired if this device is used near televisions, microwave ovens,
X-ray equipment or other devices with strong electrical fields. To prevent such
interference, use the meter at a sufficient distance from such devices or turn them off.
Prohibition
Do not disassemble or alter the device under any circumstances, as this could result in
electric shock or injury as well as adversely affect the precision of measurements.
This device is specified as Class 1 type BF unit under the standard IEC 60601-
1:2005/A1:2012 (Basic safety and essential performance of Medical Electrical
Equipment). Therefore, patients must not touch or handle inner side of the system at
any time.
Prohibition
Do not to touch signal input, signal output or other connectors, and the patient
simultaneously.
Prohibition
The unit has previously been adjusted in the factory for optimum performance.
Do not attempt to adjust switches or any other things except those specified in this
manual for operation.
Prohibition
Never pour any liquid directly on the scale platform, as it may leak and cause internal
damage.

User Manual BC720
INTRODUCTION_9
Prohibition
Never jump on the Weighing Platform, there may be a risk of stumbling and
malfunction of the equipment.
Note
This equipment has been tested and found to comply with the limits for medical
devices according to IEC 60601-1-2:2014. These limits are designed to provide
reasonable protection against harmful interference in a typical medical installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to other devices in the vicinity. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful interference
to other devices, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving device.
Increase the separation between the equipment.
Connect the equipment into an outlet on a circuit different from that to which the
other device(s) are connected.
Consult the manufacturer or field service technician for help.
Note
Place the Weighing Platform on a level and stable surface. If the equipment is used
when the Weighing Platform is unstable because not all feet are on the surface, there
may be a risk of stumbling or inaccurate measurement.
Note
Note that portable and mobile RF communications equipment can affect MEDICAL
ELECTRICAL EQUIPMENT.
Note
Consult a physician or a trained health professional for interpretation of measurement
results.
Note
In case of patients who have certain diseases, the estimates might be different

SELVAS Healthcare, Inc.
10_INTRODUCTION
Note
Incorrect operation or failure of user to maintain the unit spares the manufacturer or
his agent of the responsibility for system’s non-compliance with specifications or
responsibility for any damage or injury.
This manual is made for informational purposes and this manual and product are not
meant to be a substitute for the advice provided by your own physician or other
medical expert. You should not use the information contained in the product for
diagnosis or treatment of health problems or prescription of medication by yourself. If
you have or suspect that you have a medical problem, consult with your physician
promptly.
Defective units or accessories must be packed in the replacement cartons to be
shipped off from you to SELVAS Healthcare.
Shipping and insurance costs for return of defective unit must be prepaid by the users.
Warning
Do not modify this equipment without authorization of the manufacturer.
Warning
Connect the earth placed on the backside of this device to terminal plate to prevent
any electric shock from leakage current or a potential difference.
Warning
To avoid the risk of electric shock, this equipment must only be connected to supply
mains with protective earth.
Caution
Do not put anything other than the main unit and SELVAS’s blood pressure monitor
within 1.5 m from the patient.
Caution
Do not touch any other devices other than those specified by the manufacturer.
SAFETY SYMBOLS AND INFORMATION
The International Electro-technical Commission (IEC) has established a set of symbols for medical electrical
equipment which classify a connection or warning of any potential hazard.
The classifications and symbols are shown below. Save these instructions for your safety.

User Manual BC720
INTRODUCTION_11
SYMBOL
INFORMATION
Degree of protection against electric shock: TYPE BF
Please observe operating instructions
General warning sign
General prohibition sign
General mandatory action sign
Caution
Waste Electrical and Electronic Equipment (WEEE)
The device could be sent back to the manufacturer for recycling or proper disposal
after their useful lives. Alternatively the device shall be disposed in accordance
with national laws after their useful lives.
"OFF" (only for a part of equipment)
"ON" (only for a part of equipment)
This symbol is used inside system.
Identifies the point where the safety ground of the system is fastened to the
chassis.
Do not open. This is for factory only.
Alternating current
Direct current
Date of manufacture
Manufacturer
Non-ionizing radiation

SELVAS Healthcare, Inc.
12_INTRODUCTION
SYMBOL
INFORMATION
CE mark
Serial No.
Authorized representative in the European community.
Keep dry
This way up
Fragile
Use no hooks
For indoor use only
RoHS2
Medical Device
Guidance for Electromagnetic compatibility (EMC)
Details about the electromagnetic compatibility (EMC) of the ACCUNIQ BC720 are given below. Before
using the ACCUNIQ BC720, be sure to read and understand the following information.
1) Guidance and manufacturer’s declaration –electromagnetic emissions
The ACCUNIQ BC720 is intended for use in the electromagnetic environment specified IEC 60601-1-
2:2014 (Fourth Edition).
2) Guidance and manufacturer’s declaration –electromagnetic immunity
The ACCUNIQ BC720 is intended for use in the electromagnetic environment specified IEC 60601-1-
2:2014 (Fourth Edition).
3) Guidance and manufacturer’s declaration –electromagnetic immunity 2
The ACCUNIQ BC720 is intended for use in the electromagnetic environment specified IEC 60601-1-
2:2014 (Fourth Edition).

User Manual BC720
INTRODUCTION_13
4) Recommended separation distances between portable and mobile RF communications equipment and
the ACCUNIQ BC720
The ACCUNIQ BC720 is intended for use in the electromagnetic environment specified IEC 60601-1-
2:2014 (Fourth Edition).

SELVAS Healthcare, Inc.
14_ABOUT BODY COMPOSITION
ABOUT BODY COMPOSITION
Body Composition
Human body consists of body fat and lean body. Lean body means non-fat constituents of human body
like body water, muscles, mineral, etc.
Body water is divided into intra- and extra-cellular water and the ratio between them is controlled and
maintained within a certain range. Body fat is piled beneath the skin and between abdominal organs. Body
fat is hydrolyzed to make energy needed to normal physiological function when energy supply through
food intake is not sufficient, but excessive fat in the body itself is a kind of disease and causes lifestyle
diseases.
Healthy people maintain the balance of body composition in a steady proportion but unhealthy people
persons fail to keep this balance. When the balance in body composition is broken, diseases like obesity,
malnutrition, osteoporosis, etc. can be caused.
Obesity
Various methods can be used to assess obesity but the key factor in obesity assessment is the amount of
fat accumulated in the body.
In general, obesity is defined as the state of not only excessive weight compared with height (visible obese)
but also excessive body fat compared with weight (invisible or visible obese).
Strictly speaking obesity is the state that body fat occupies considerably high ratio to weight.
Necessity of Body Composition Analysis
Body Composition Analysis is a good indicator in finding possible health problems. Body composition
analysis enables professionals to find obesity or imbalance in body composition at an early stage and
helps subjects keep their body healthy.
Waist to hip ratio
Waist to hip ratio (W.H.R.) shows the distribution of fat stored in one’s abdomen and hip. It is simple but
useful to assess body fat distribution. Body fat is stored in two distinct ways. They are often categorized
into and called 'apple' and 'pear' type. Apple type shows bigger girth of waist than hip and pear type has
bigger girth of hip than waist. If body fat in abdomen increases more, the risk to cardiovascular diseases,
diabetes, etc. becomes higher.

User Manual BC720
ABOUT BODY COMPOSITION_15
Abdominal Fatness
Body fat is divided into subcutaneous fat and visceral fat. Visceral obesity is considered to be a critical risk
factor along with Percentage of body fat.
Lipoprotein lipase can be easily activated in visceral fat, and it causes visceral fat to be dissolved easily.
Dissolved visceral fat goes into liver through the blood vessel and causes fatty liver or increases lipid in
the blood. It also elevates the risk of hyperinsulinemia, hypertension, and cardiovascular disease.
Visceral fat generally occupies 10 ~ 20 % of body fat and visceral obesity is assessed based on the
indicators below.
the cross sectional fat area between L4 ~ L5 is 100 cm2and over
the visceral fat to subcutaneous fat ratio is 0.4 and over
the waist to hip ratio (W.H.R.) is over 0.9 (male) / 0.85 (female)
the circumference of waist is over 102 cm/45 inches (male) _ 88 cm / 35 inches (female)
Visceral fat increases after 30s in men and after Menopause in women. It is more common in men than
women and the old than the young. Visceral fat tends to increase with aging. Because the combustion
rate per minute of visceral fat is higher than that of subcutaneous fat, visceral fat can be easily reduced
by exercise or dietary control in case of abdominal obesity. W.H.R. is the ratio of waist to hip circumference
and has relation to one’s figure.
Segmental Analysis
This device analyzes soft lean mass, body fat mass, total body water and E.C.W./T.B.W. of five body parts;
trunk, right arm, left arm, right leg, and left leg. This function can be used as an assessment tool to
evaluate the result of exercise or rehabilitation treatment.
Age Matched of Body
It is the estimated physical age of the subject considering body composition analysis result, gender, and
biological age. This is calculated by comparing the optimal body composition based on the gender and
biological age of the subject with the actual analyzed body composition. It can be used to evaluate the
subject’s health and body development.
Study
It is the provided impedance.
Impedance indicates the segmental impedance of five body parts (left and right arms, left and right legs,
and trunk) corresponding to each frequency (1~ 1000 kHz).

SELVAS Healthcare
16_TERMS OF EACH PART AND FUNCTION
TERMS OF EACH PART AND FUNCTION
Main Parts
The main system of ACCUNIQ BC720 consists of as follows.
①Main body
②User manual & Data
management program
③Adapter
④USB Cable
⑤Wi-Fi Dongle
⑥Bolts
⑦5mm L-wrench
⑧Body Cover
⑨A4 result sheet
Model or specification of accessories can be changed according to market supply and demand.
Options
1. A4 result sheet for segmental parts and
children
It shows the segmental results and children growth curve
to make users easily understand the condition of 5 body
parts and the growing state of children.

User Manual BC720
TERMS OF EACH PART AND FUNCTION_17
2. Data management program
This program helps managing body composition easily
and systematically. It shows the core items needed to
control body composition. The items include measured
body composition, dietary control plan, exercise plan, etc.
If the device is connected to blood pressure monitor, it
also indicates the measurer's blood pressure.
ㅍ
3. Bluetooth Dongle
It allows wireless communication with a PC.
4. Automatic Blood Pressure Monitor
If SELVAS’s automatic blood pressure monitor for hospital
is connected to this device, the user can easily check
his/her blood pressure. Detecting the patient with
hypertension may help better manage his/her blood
pressure through weight control.

SELVAS Healthcare
18_TERMS OF EACH PART AND FUNCTION
5. Ultrasonic Height Meter SM103
It is an instrument to measure users' Height more
accurately and quickly. It employs standoff determination
method using ultrasonic sensor. It combines the
technology of artificial intelligence and reflected
characteristics of ultrasonic height meter.
<Good point of using SM103 as an option>
1) It automatically measures height.
2) Fast measurement
3) Accurate measurement
4) LCD monitor attached to the column leads the user to
measure height in correct way.
<When using SM103>
1) Install it in a place with stable temperature.
2) Do not install it at the location facing the heater and
air conditioner.
3) Do not put a sticker or foreign things on body of the
SM103.
4) Nothing should be placed within a radius of 60cm
Note
Measuring height in the morning is even average 1~2cm higher than in the evening,
because vertebral cartilage is pressed maximum in the evening by owns weight.
Model or specification of accessories can be changed according to market supply and demand.

User Manual BC720
TERMS OF EACH PART AND FUNCTION_19
Appearance of the device
Front Part
The front and back of ACCUNIQ BC720 looks as below.
[Front Part]
[Rear Part]
Display
/
Operation Part
Body Part
Base Part

SELVAS Healthcare
20_TERMS OF EACH PART AND FUNCTION
Term of each parts and its function
Display Operation Part
Large LCD (Color TFT)
It indicates the data the measurer input.
It also shows measuring process in messages and graphic display.
Key pad
There is a keypad in ACCUNIQ BC720. The function of each button is same as the touch screen.
Touch panel
LCD (Liquid Crystal Display) panel as touch screen
It is easy to input data.
Other manuals for ACCUNIQ BC720
1
Table of contents
Other SELVAS Healthcare Medical Equipment manuals

SELVAS Healthcare
SELVAS Healthcare ACCUNIQ BP210 User manual

SELVAS Healthcare
SELVAS Healthcare ACCUNIQ BP500 User manual

SELVAS Healthcare
SELVAS Healthcare SensePlayer T90ET User manual

SELVAS Healthcare
SELVAS Healthcare ACCUNIQ BC720 User manual

SELVAS Healthcare
SELVAS Healthcare Accuniq BC310 User manual

SELVAS Healthcare
SELVAS Healthcare Accuniq BC380 User manual

SELVAS Healthcare
SELVAS Healthcare Accuniq BC310 User manual

SELVAS Healthcare
SELVAS Healthcare ACCUNIQ BC300 User manual