Seneca MyALARM2-4G User manual

MI00613-0-EN INSTALLATION MANUAL 1/8
INSTALLATION MANUAL
MyALARM2-4G
SENECA s.r.l.; Via Austria, 26 – 35127 – PADOVA – ITALY; Tel. +39.049.8705359 - Fax +39.049.8706287
My2SL
DOCUMENTATION
My2GL
DOCUMENTATION
PRELIMINARY WARNINGS
The word WARNING preceded by the symbol indicates conditions or actions that put the user’s safety at
risk. The word ATTENTION preceded by the symbol indicates conditions or actions that might damage the
instrument or the connected equipment.
The warranty shall become null and void in the event of improper use or tampering with the module or devices
supplied by the manufacturer as necessary for its correct operation, and if the instructions contained in this
manual are not followed.
WARNING: The full content of this manual must be read before any operation. The module must only be used by
qualied electricians. Specic documentation is available using the QR-CODE shown on page 1.
Electrical and electronic waste disposal (applicable in the European Union and other countries with recycling).
The symbol on the product or its packaging shows the product must be surrendered to a collection centre authorized
to recycle electrical and electronic waste.
The module must be repaired and damaged parts replaced by the Manufacturer.
The product is sensitive to electrostatic discharges. Take appropriate measures during any operation.
CONTACT INFORMATION
This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised.
The content of this document corresponds to the described products and technologies.
Stated data may be modied or supplemented for technical and/or sales purposes.

MI00613-0-EN INSTALLATION MANUAL 2/8
MODULE LAYOUT
LED STATUS LED meaning
PWR (Green)
On Device ON
Off Device OFF
Fast ashing Access to micro SD card
Slow ashing Device in datalogger function
NET (Yellow)
On Device in network search
Fast ashing
Data transmission
Slow ashing
Device registered to the network (2G network only)
Off Modem off
SIGNALS VIA LED ON FRONT PANEL
80 mm
108 mm
32 mm
8 mm
CASE DIMENSIONS SYMBOLS ON THE ENCLOSURE
Weight 150 g Case Polycarbonate / ABS material
ON / OFF power button
GPS antenna
Menu access button
Slot for mini SIM
Slot for micro SD card
Micro USB connector
GPS
SIM
SD

MI00613-0-EN INSTALLATION MANUAL 3/8
TECHNICAL SPECIFICATIONS
CERTIFICATIONS
POWER SUPPLY
Voltage: 6 ÷ 15Vdc, 500mA Max.
Battery: Lithium Ions 3.7 V ÷ 1000mAh, rechargeable non-replaceable.
Internal battery absorption: 3.5 W Max.
DIGITAL
INPUTS
4 inputs
Type: Reed, contact, PNP, Pulscap 30 Hz
Maximum frequency Threshold OFF: 0 ÷ 3 Vdc, I < 1mA
Threshold ON: 6 ÷ 24Vdc, I > 3mA
ANALOG
INPUTS
2 inputs
Type: Voltage 0÷ 30Vdc / Current 0÷ 20mA
Precision: 0.1% of full scale
VOLTAGE
OUTPUT +12 Vdc 50 mA (maximum current)
TEMPERATURE
SENSOR NTC internal (as standard), external (option) thermistor
USB PORT 1 micro USB for conguration and supply
DISPLAY 128 x 32 LCD Dots with visible area of 39 mm x 8.6 mm
CONNECTIONS Spring clamps, 3.5 mm pitch, connector for Micro USB and
SMA connector for GSM antenna, MMCX for GPS (option)
INTERNAL
MEMORY FLASH 1 MB (program) + 8 MB (log + data)
Micro SD slot Push-Push for SD card and SD HC card / max 32GB
SIM slot Push-Push for mini SIM (15 x 25 mm)
FREQUENCY
BANDS
LTE-FDD B1/B3/B5/B7/B8/B20
GSM/GPRS/EDGE 900/1800 MHz
ENVIRONMENTAL
CONDITIONS
Seneca recommends use between 0 and 45°C for the battery correct operation.
Temperature: with the power supply present: -20 ÷ +55°C; with use of the battery (when discharged): -20 ÷ +45°C.
Charging is possible in the range: 0 ÷ +45°C.
Humidity: 30% ÷ 90% non condensing.
Storage temperature: from -20°C to +20°C < 1 year; from -20°C to +45°C < 3 months;
from -20°C to +60°C < 1 month
Protection rating: IP20
GPS CARD SPECIFICATIONS (OPTION)
RECEIVER
22 channels
SENSITIVITY
-165 dBm
FIX TIME
32 s usually
ACCURACY
Up to 2.5 m
RELAY EXPANSION CARD SPECIFICATIONS (OPTIONAL)
DIGITAL
OUTPUTS
2 outputs
Type: Relay 3 A max - 250V SPST (with shared terminal)

MI00613-0-EN INSTALLATION MANUAL 4/8
INITIAL POWERING ON OF THE DEVICE
Device is supplied in “shipping mode”. This mode prevents any unnecessary discharge of the battery during transport as
well as any accidental switch-ons.
To exit this mode, simply power the device via the cable supplied.
N.B.: During “shipping mode” the power button is disabled.
ON/OFF BUTTON AND SCROLL DISPLAY BUTTON
MyBoat is equipped with a PWR button located on the top left side (front panel
view). Pressing this button turns the module on and off. To switch it off, hold the
PWR key down for a few seconds.
MyBoat is also equipped with a SCR button, located on the top right side (front
panel view). Pressing this key displays the parameters.
MICRO USB PORT AND POWER SUPPLY
The device has a micro USB connector on the left side of its enclosure, which can
be used for conguration, rmware updates and to recharge the internal battery.
To recharge the internal battery, use:
- the 12 V power supply (supplied) by connecting the cables to the + and -
terminals (GND).
- a PC via the micro USB port with a standard cable.
Power supply through the USB jack is not suitable for xed installations,
or congurations where relays and/or digital inputs are used.
PWR SCR
ANTENNA
ANTENNA
micro
USB
AUTO POWER-OFF
If the display shows “LOW BAT”, it means that the internal battery is low, after 60 seconds the device switches off
automatically.
To restore the battery charge to an appropriate value, recharge the device using one of the recommended modes.
INSERTING THE SIM CARD AND SD CARD
INSERTING THE SIM CARD
The device has a slot for mini SIM located in the right side of the enclosure.
To insert the card in its corresponding slot, make sure the metal contacts are facing right (as
seen in the gure).
INSERTING THE SD CARD
The control unit is equipped with an SD card input that can be used to update the device’s
rmware and update the information and connection parameters with the world’s best known
telephony operators.
The input for micro SD card is located on the right side of the enclosure.
To insert the SD card in its corresponding slot, make sure the metal contacts are facing right
(as seen in the gure).
SIM
card
SD
card

MI00613-0-EN INSTALLATION MANUAL 5/8
ASSEMBLY REGULATIONS
The device has been designed for vertical installation or on a DIN IEC EN 60715 omega rail.
Avoid mounting the device inside metal cabinets or on top of heat-generating equipment.
INSTALLATION ON DIN IEC EN 60715 RAIL AND WALL FIXING
As shown in the gure on the side:
1. Insert the hooks of the support for DIN IEC EN 60715 rail
into the corresponding slots on the back of the container.
2. Hook the support to the DIN IEC EN 60715 rail.
Alternatively:
1. Through the two holes on the support for DIN IEC EN 60715
rail it is possible to x it to the wall with the two anchors
supplied.
2. The control unit can be xed to the support by inserting
the hooks of the support into the slots on the back.
ASSEMBLY RULES FOR VERSION WITH GPS (OPTIONAL)
For optimal reception of the GPS signal given by the satellites, the control unit should be positioned in an area not covered
by metal structures. If this is not possible or if the satellite reception is no good, an optional external antenna with 3m cable
(code A-GPS) is available. Follow the procedure supplied with the package for the installation of the external antenna.
SAFETY INFORMATION
The control unit has a terminal block inside its enclosure.
To access the internal terminal block of the device, unscrew
the screw at the centre of the black cover positioned at the
bottom of the enclosure and lift up.
In the side gure, the cover has been removed.
IMPORTANT: With the relay card, mobile wiring of cables
connected to terminals is not permitted. To make the cables
from the terminals safe, use the break-out passages in the
back of the enclosure. When the wiring is complete, fasten
the protective cover on the device with the screw to prevent
any accidental contact.
12
3
456 789 10 11 12 -
+
13

MI00613-0-EN INSTALLATION MANUAL 6/8
ELECTRICAL CONNECTIONS
INSERTION AND EXTRACTION FROM TERMINALS WITH A PUSH-WIRE CONNECTION
Insertion of a rigid cable
Press down Recommended aying:
8-9 mm
Insertion of a thin cable Extraction of a rigid cable
A: press with a
screwdriver
B: insert
the cable
A: press with a
screwdriver
B: extract
the cable
P
A
1
2
3
4
5
6
7
8
9
10
11
12
13
+
4
5
6
7
9
4
5
6
7
10
8
11
12
10
11
-
-
P P
A
A
-
PUSH-WIRE TERMINAL BLOCK
KEY
Digital signal 6 - 24 Vdc
Digital contact
Current analog signal
(loop 4 - 20 mA)
Current/voltage analog signal
Digital output 1 - relay N.O. (*)
Common to the two relays (*)
Digital output 2 - relay N.O. (*)
Digital Input 1
Digital Input 2
Digital Input 3
Digital Input 4
12 Vdc output
(50 mA max)
Ground
Analog input 1
Analog input 2
Ground
Input for NTC external sensor
Power supply 6-15 Vdc (**)
Ground
(**) Tip: connect a 1 A
protection fuse.
(*) Available with the relay
board (optional)

MI00613-0-EN INSTALLATION MANUAL 7/8
DISPLAY FUNCTIONS AND USE
The main display page provides the following information:
A - Network signal level
B - outlet 1 status
C - outlet 2 status
D - digital input 1 status
E - digital input 2 status
F - digital input 3 status
G - digital input 4 status
H - battery level
To change the page on the display, use the SCR key as shown in the "INITIAL POWERING" paragraph.
By holding the PWR key for a few seconds you will have access to the main menu:
ABCDE F G H
To choose the desired command use the SCR key which allows you to scroll through the various options,
to conrm the desired option press the PWR key.
It is also possible to call up the contextual menu of a page by holding down the SCR key for a few seconds.
Through a contextual menu it is possible to display other sub-pages and / or information.
Pages with contextual menus are identiable by a triangle in the display top right corner.

MI00613-0-EN INSTALLATION MANUAL 8/8
MY2
PRODUCT ID CODE
A label will be applied to the product packaging that allows you to recognize the model purchased.
Find below the meaning of the codes applied to the packaged instrument:
EQUIPMENT
NAME
MODEL:
SL: SECURITY
GL: DATALOGGER/GPS
RELAY:
0: ABSENT
R: PRESENT
RADIO:
0: ABSENT
W: PRESENT
CONNECTIONS:
C: CONNECTIONS
M: TERMINALS
COLOUR
B: BLUE
G: GREY
SL GL R 0 W 0 C M B G
Table of contents
Other Seneca Data Logger manuals

Seneca
Seneca Z-LTE User manual

Seneca
Seneca Z-UMTS HW2 User manual

Seneca
Seneca Z-UMTS User manual

Seneca
Seneca RTU-LP User manual

Seneca
Seneca MyALARM2 User manual

Seneca
Seneca Z-LTE-WW User manual

Seneca
Seneca Z-UMTS User manual

Seneca
Seneca Z-GPRS2 User manual

Seneca
Seneca Z-8R-10A User manual

Seneca
Seneca Z-LOGGER User manual
Popular Data Logger manuals by other brands

Extech Instruments
Extech Instruments RHT10 user guide

Kilowatt Labs
Kilowatt Labs SIRIUS 1860-48-B-1C-M-SD-A-X-X-G user manual

OTT
OTT ecoLog 800 operating instructions

Grundfos
Grundfos Alpha Reader Installation and Operating Instrucitons

sebaKMT
sebaKMT SmartEAR user manual

Neptune
Neptune MRX920 user manual