What is Sensilift 4
Who should use Sensilift
7
When shouldn’t Sensilift be used
8
8
10
11
12
12
12
13
User Instructions
13
Device Set-Up
14
How to prepare yourself
15
Preliminary Test
16
How to Use the Sensilift device
17
Recommended treatment protocol
17
Treatment areas
18
What to expect when using Sensilift
19
Post facial treatment care
19
Cleaning and troubleshooting
Cleaning
Troubleshooting
Customer Service
© All rights reserved to EL Global Trade Ltd.
3
Device Specification Parameters
Possible Side Eects
Handheld description
User interface description
5
6
8
9
Who cannot use Sensilift - CONTRAINDICATIONS
What you must do to avoid serious harm – WARNINGS
What you must do to avoid other harm - CAUTIONS
17
English
Sensilift device description

English
4
What is Sensilift
Sensilift is a home use device
intended for wrinkles
reduction, skin tightening and
skin elasticity renewal.
Sensilift brings a completely
new approach to non-invasive
skin rejuvenation featuring
Sensica proprietary Dynamic
RF™ technology, combining
clinically proven RF (Radio
Frequency), commonly used by
doctors, with advanced facial
massage.
Dynamic RF™ technology is a
combination of RF with facial
massage that maximizes the
eectiveness of the treatment,
by allowing multiple RF waves
to reach wider range of skin
layers and assist in getting best
possible visible, ongoing and
lasting results.
thermal eect on biological
tissue.
A major cause of skin wrinkles
is the reduction in the quantity
and quality of collagen fibers
in the dermis and hypodermis.
Heat is generated as a result
of tissue resistance to the
movement of electrons within
the RF field. Then the
sub-cutaneous heat
generates new collagen and
enhances existing collagen,
leading to wrinkle reduction
and improved skin elasticity.
Sensilift treatment creates
enough thermal eect to
induce collagen remodeling
with no ablative thermal
damage of the epidermis or
dermis.
How does it work?
Introducing the new Dynamic
RFTM technology
Radio Frequency (RF) is a form
of electromagnetic energy that
has being used in doctors’
clinics and spa centers for a
long time and was found to
produce a highly ecient
Please make sure to
carefully read this user
guide before you start
treating with Sensilift.
The user guide, as well
as instructional video,
can also be found at
www.sensica.com

English
5
Sensilift Device
Description
Sensilift kit includes the
following main components:
•Sensilift handheld device:
Massage fingers and
electrodes – two massage
fingers (treatment fingers)
combined with RF electrodes
in order to simultaneously
apply the RF and massage
treatments. Safety
temperature sensors are also
embedded in the treatment
fingers.
External power supply
“Base Gel”:
Especially designed to work
with Sensilift. The Base Gel
ensures proper delivery of
Dynamic RF energy and best
possible results by improving
contact between the device
and the skin and as a result
improve skin conductivity.
Using Sensilift without
applying the Base Gel first is
strictly prohibited as it will
compromise your safety and
treatment ecacy.
•
•

English
6
Handheld description
Temperature
sensors
RF electrodes
combined with
massage fingers
2
1
Power
socket
1-2 Massage
level lights
1-3 RF energy
level lights
RF energy
selection touch
button
Status
indicator
4
5
6
3
8
7
Massage
selection
touch button

English
7
Status
Indicator
RF energy level
selection touch
button
Massage level
selection touch
button
Blinking yellow
light
Blinking
alternating
green and
yellow lights
1-3 energy
levels lights
1-2 massage
level lights
Sensilift is on Stand-by mode.
In case of no light, make sure
the power cord is plugged-in
properly.
Sensilift is in Treatment mode.
RF is activated, skin contact is
detected and the treatment is
undergoing.
Green light on, indication of RF
energy level. Press the RF
energy level selection button
repeatedly until you reach the
desired level: 1, 2, 3 or o.
Green light on, indication of
massager function level. Press
the massage level selection
button repeatedly until you
reach the desired level: 1, 2, or
o.
User interface description
Steady green
light
Sensilift is in Error mode.
the device detected a
malfunction and prevents the
activation of the RF and
massage functions.

English
8
•
•
•
•
•
Who should use
Sensilift
•Sensilift is intended for women
and men who desire to
reduce facial wrinkles, tighten
their facial skin and renew skin
elasticity
Sensilift is intended for use on
cheeks, nasolabial “smile”
folds, “crow’s feet” next to
your eyes, forehead, chin,
allowed areas of neck,
décolletage and hands.
Sensilift is intended for use on
fine wrinkles with minimal skin
lines.
Sensilift is intended for use on
fine to moderate depth
wrinkles of moderate number.
•
•
•
any severe known heart
disorder such as arrhythmias.
If you are pregnant or
breastfeeding.
If you suer from severe or
uncontrolled endocrine or
metabolic conditions (such as
diabetes and uncontrolled
thyroid disease).
If you have a damaged
immune system or
autoimmune disorders such as
AIDS, or Lupus, or if you use
drugs that influences the
immune system.
If you suer from blood
clotting disorders or excessive
bleeding or bruising or
damaged wound healing or if
you routinely taking blood
thinning medications.
If you suer from a history of
deep vein thrombosis (formation
of a blood clot in the veins).
If you have history of collagen
disorders or suer from keloid
scar (growth of extra scar tissue
where the skin has healed after
an injury) formation.
If you have extreme general
illness, such as hepatitis, liver
disease or epilepsy.
If you suer from sensitive skin
such as in cases of frequent
redness, inflammations,
breakouts, infection and acne
or extra dry skin.
•
•
When shouldn’t
Sensilift be used
Who cannot use Sensilift -
CONTRAINDICATIONS
Do NOT use Sensilift device if
you have any of the following
conditions:
If you are under the age of 18.
The use of Sensilift on or by
children has not been
established and could result in
serious injury.
If you have an active implant
such as a pacemaker or
insulin pumps or if you have
•
•
•

English
9
•If you have diminished or
exaggerated perception of
temperature changes.
If you have been taking
Accutane in the past 6
months.
If you have heat induced
disease or an active skin
disease (Herpes, Eczema, rash
etc.) in the treatment area.
Do not use the device if you
have skin cancer or on areas
at risk of malignancy or if you
have received radiation
therapy or chemotherapy
within the past 3 months.
What you must do to avoid
serious harm – WARNINGS
•Do not use over any
permanent implants in the
designated treatment area
(including but not limited to:
silicon or injected chemical
materials, metal plates or
other metal materials).
If you had plastic surgery
(such as face lifting or eyelid
surgery) if you had aesthetic
•
In some cases Sensilift safety
and eectiveness has not
been tested or established
yet. Therefore, if you have any
of the following conditions, it is
NOT advised that you use the
device:
•
•
injections of fillers (such as
Hyaluronic acid, Collagen, fat or
Botulinum toxin) in the treatment
area within the past 3 months.
If you had professional
chemical peel within the past 3
months (Alpha hydroxyl acids
(AHA) such as glycolic acid or
Beta hydroxyl acid (BHA), or
professional facial abrasion
(such as dermabrasion, facial
resurfacing, or deep chemical
peeling (Phenol, Trichloraacetic
acid-TCA, and/or ablative
laser treatments) within the
past 3 months.
Do not use over nostrils, lips
of the mouth, ears, breast or
genital area, or areas not
recommended in this user
manual.
Do not use over the thyroid
since it may cause adverse
events.
Do not use over the eyelids,
eyes or sides of the eyes
next to your nose) since it
may cause eye damage.
Do not use the Sensilift over
any metal items (such as
earrings, jewelry or piercing) or
on tattoos or permanent make
up in the designated
treatment areas.
Do not use over sunburns, dark
brown or black spots such as
•
•
•
•
•
•

English
10
Note: If you have undergone any
other aesthetic procedures in the
designated treatment area or any
uncertainty regarding potential
side eects, consult your physician
before using Sensilift.
What you must do to avoid
other harm - CAUTIONS:
•Never use flammable liquids
such as alcohol or acetone
(including perfumes, sanitizers,
or other products containing)
to clean the skin one hour
before using Sensilift as it may
cause burning of the skin.
Do not open or repair the
device as it may expose you to
dangerous electrical components.
•
•
•
Do not place, store or use
Sensilift near bathtubs,
showers, basins or other
vessels containing water as
this may cause severe
electrocution.
Do not leave Sensilift
unattended while plugged
into the electricity as it may
lead to electrocution risk.
Use Sensilift only according to
the instructions for use and for
the intended use.
Do not use the device if any
part of the device is missing,
damaged or loose, if the
device is not working properly, if
you see or smell smoke or if the
device becomes damp or wet.
Do not use Sensilift device
without applying the Base Gel
before use.
Do not use the Base Gel after
its expiration date.
Before using Sensilift, make sure
the device is clean, dry and
intact. Cleaning instructions are
detailed in the cleaning section.
•
•
•
Use Sensilift only with
original power supply. For
your safety, never use DC
adapters which are not
approved by the
manufacturer.
Note: Sensilift is designed to be
used by a single user.
•
freckles, birth marks, around
the nipples, moles or blisters in
the treatment area.
If you are allergic or sensitive
to chrome, nickel or any
component of the Base Gel.
This appliance is not intended
for use by persons with
compromised physical,
sensory or mental capabilities.
Do not use Sensilift without
facial hair removal from
treatment areas, since it may
result in burn in these areas.
•
•
•
•

English
11
Possible Side Eects
When using Sensilift device
according to the instructions for
use, side eects are rare.
However, every aesthetics
procedure, including the usage
of home use devices, may
cause some degree of side
eects. Therefore, it is important
that you understand and
accept the risks and
complications that can occur
with RF wrinkle reduction device:
Degree
of Side
Eects
Side Eects
Minor
Side-
Eects
Rare
Side-
Eects
Extremely
Rare Side-
Eects
Local pain
Skin irritation
Skin redness
Skin sensitivity
Allergic contact
dermatitis or
sensitivity to ”Base
Gel”
Skin mild burns
Pigment changes
Excessive redness
and swelling
Urticaria, purpura or
ecchymosis
Hematoma
Severe Burns
Infection
Bruising
Blistering

English
12
User instructions
Sensilift is intended for use on
cheeks, nasolabial “smile”
folds, “crow’s feet” next to your
eyes, forehead, chin, allowed
areas of neck, décolletage
and hands.
Device Set-Up
Remove all components
from the box (Sensilift device,
power supply and the Base
Gel).
Before beginning the
treatment make sure the
treatment fingers are clean,
dry and intact.
Plug the power supply end
into an electrical outlet and
the cord end into the device
socket.
Sensilift is now ready to
be used.
1.
2.
3.
How to prepare yourself
1.
2.
3.
4.
5.
6.
Prior to use, make sure your
skin is dry, clean and free of
topical products (such as
moisturizers), liquids or lint.
Use a mirror to assist you
during treatment. Before
beginning the treatment,
make sure the treatment
fingers are clean, dry and
intact.
Never use flammable liquids
such as alcohol (including
perfumes, sanitizers, or other
applications containing
alcohol) or acetone to clean
the skin one hour before
using Sensilift as it may
cause burning of the skin.
For Sensilift maintenance
and prolong use, device
cleaning is a must (Cleaning
chapter).
Perform a preliminary test on
a small patch of skin in the
intended treatment area 48
hours prior to first use of
Sensilift to determine energy
level settings for your
treatment (as depicted in
the preliminary test section).
Sensilift is suitable for men.
However male users should
make sure their skin is clean
shaven.

English
13
Preliminary Test
How to use Sensilift device
The preliminary test is intended
to determine your skin reaction
to Sensilift treatment and help
you to find the best settings for
each treatment area. Perform a
preliminary test on each area
you intend to treat 48 hours
prior to the full treatment.
Apply a thin, even layer of
Base Gel included in your kit,
on the area of your skin
intended for treatment.
Set the Radio Frequency (RF)
energy level and the
massage speed to the level
you selected in your
preliminary test treatment.
Press the RF energy level
selection button repeatedly
until you reach the desired
level: 1, 2, or 3. Press the
massage level button
repeatedly until you reach
the desired level: 1 or 2.
The activation of either RF or
massage functions can be
done independently or
1.
2.
3.
Before using Sensilift, apply a
thin, even layer of Base Gel
on treated area.
Start your test with RF energy
level 1 and massage level 1.
Increase the levels according
to your comfort.
The treatment will create a
warm sensation on your skin.
Stop the test if you do not
feel comfortable or if you see
adverse eects such as
severe redness or blistering.
Perform the preliminary test
for a total time of about 3
minutes.
Wait 48 hours and examine
the tested area.
If the skin in the tested area
seems normal (no adverse
eects) you can proceed
with a full treatment in the
highest comfortable energy
level and massage level you
tested.
Note: The RF energy level indicates
the rate at which the temperature
rises when in heating mode. A high
RF energy level will enable you
faster and even heating. You can
achieve maximum results with all
RF energy levels (for lower levels, it
will just take longer time to reach
the eective temperature),
therefore, select your optimal RF
energy level according to your
level of comfort.
Note: A preliminary test should be
conducted before proceeding to
a full treatment. See “Preliminary
test section” above.
•
•
•
•
•

English
14
together. Both functions will
be activated at level 1.
Select dierent levels based
on the preliminary test.
Sensilift is equipped with 2
safety sensors which will
keep the temperature in the
eective and safe range
during the whole treatment.
Place the treatment fingers
on the intended area,
ensuring full contact with
your skin during the entire
treatment. Sensilift will
indicate the proper skin
contact by the green status
light. If Sensilift is not
properly placed, the RF
energy will not be delivered.
If you do not feel sensations
of warmth after
approximately 10 seconds,
try moving Sensilift on a
smaller treatment area,
and/or increasing the RF
energy.
Move the device on the
treated area in slow circular
or back and forth motion
while constantly and firmly
contacting the skin.
See treatment areas,
treatment time and
treatments schedule in the
"Recommended treatment
protocol" chapter.
4.
5.
6.
7.
8.
9.
10.
11.
At the end of each
treatment session turn o
the device and then unplug.
After completing the
treatment, wipe o the
remaining Base Gel from the
treated area.
Cleaning instructions for
before and after are
depicted in the Cleaning
chapter.
Recommended treatment
protocol:
•For long-lasting skin
tightening results, use
Sensilift once a week on
each area for the period of 8
weeks.
Response to Sensilift
treatment diers between
individuals and depends on
environmental and biological
factors, heredity and aging.
To sustain optimal long term
results, Sensilift maintenance
treatments might be
performed every 4-8 weeks,
as needed.
•
•

English
15
Treatment areas
Do not treat full areas with
energy levels you have not
tested before
Forehead and between the eyes
(treatment area 1)
•Place the treatment fingers
on the area as indicated in
the picture.
Keep moving
Sensilift up and
down across the
forehead area.
Recommended
treatment time for
this area is 10 minutes.
•
•
"Crow's feet" (around the eyes)
(treatment area 2)
•Place the treatment fingers
on the area as indicated in
the picture.
Keep moving Sensilift in
continues slow 'side to side'
circular motion.
Avoid areas such as inside
•
•
the nostrils, eye cavity and
oral cavity, as treatment in
these areas may cause
adverse eects.
Avoid contact
with the eyes.
Recommended
treatment time for
this area is 5 minutes
(for each side).
•
•
Cheek and nasolabial "smile"
folds (treatment area 3)
•Place the treatment fingers
on the area as indicated in
the picture.
Move Sensilift in
slow circular
motions across
the cheek area up
and down over the
“smile folds”.
Recommended treatment
time for this area is 5 minutes
(for each side).
•
•

English
16
What to expect when
using Sensilift
Sensations of warmth during
the treatment session –
created by the RF energy
during treatment.
Some mild red or pink color
on the skin – during and just
after using Sensilift.
•
•
During your facial wrinkle
reduction and skin tightening
treatment it is normal to
experience:
Chin treatment
(treatment area 4)
•Place the treatment fingers
on the area as indicated in
the picture.
Keep moving
Sensilift from one
side of the chin to
the other.
Recommended
treatment time for
this area is 5 minutes.
•
•
Neck treatment
(treatment area 5)
•Place the treatment fingers
on the area as indicated in
the picture.
Keep moving
Sensilift up and
down across the
neck area.
The recommended
treatment time for
this area is 5 minutes
(for each side).
Caution: Avoid treatment in
the lower third of the neck
since this area is more
sensitive, avoid from treating
the thyroid area (marked )
•
•
Décolletage and hands
treatment
•Place the treatment fingers
on the desired treatment
area.
Keep moving Sensilift in slow
circular motions across the
décolletage or hands area.
Since décolletage and
hands are large areas, for
best results it is
recommended to divide
those areas to sub-areas of
approximately 4cm2.
Recommended treatment
time for each sub-area is 5
minutes.
•
•
•

English
17
Post facial treatment care
Cleaning and
troubleshooting
Cleaning
•After completing the
treatment, wipe o the
remaining Base Gel from the
treated area.
We recommend you use the
Sensilift post treatment
Anti-aging cream to enhance
treatment ecacy and long
lasting results.
Apply a high-factor
sunscreen (at least 30 SPF)
and protect the treated area
from sunlight for two weeks
following treatment.
Following the treatment,
avoid any usage of hot water
on your face and discontinue
usage of abrasive or harsh
products for two days.
In cases where superficial
crusting or scabbing occurs,
do not rub, scratch or
remove the scab. Cleanse
the area gently and pat dry.
Makeup may be applied
immediately after treatment.
•
•
•
•
•Make sure to turn o and
unplug Sensilift before cleaning.
It is recommended to clean
Sensilift device from residual
of Base Gel with a soft damp
cloth or paper towel. Make
•
•
Troubleshooting
sure the entire electrodes
area, including the
temperature sensors and
silicone cover, are cleaned
thoroughly.
•
•
If you experience any problems
with your Sensilift, please refer
to the information below to try
to resolve it:
If Sensilift does not turn on:
a. Make sure that the
power cord is plugged
•
Do not rinse Sensilift
under running water, as
it may cause device
malfunction.
Keep Sensilift device dry.
Never place, store or use
Sensilift near bathtubs,
showers, basins or other
vessels containing water as
this may cause severe
electrocution.
If you do not plan using your
Sensilift device for a long
period of time, it is
recommended to keep it
clean and stored.
If you plan to travel and take
your Sensilift with you, you
should store it in the original
box and follow the
maintenance instructions.
•

English
18
•
properly into the electrical
outlet and into the device
power socket.
b. Make sure the power
outlet has power.
If Sensilift does not deliver RF
signal energy (you cannot
feel the warm sensation):
Verify there is full contact
with the skin and Base Gel
was applied properly on the
skin. The RF signal will be
activated only when the
treatment fingers are in full
contact with the skin. See
indicator stated in User
interface description chapter.
General error:
a. In case of dirt or debris
stuck on the electrodes
fingers, you should clean
the electrodes in accor
dance to the Cleaning
chapter. If you can't get
the area clean, contact
our customer service.
b. In case of a general error,
reset the device – unplug
the power cord from the
electrical outlet on the
wall, wait 10 sec and then
reconnect it.
c. If you still have problems
with your device, please
contact our customer
service.
•
Costumer Service
Device specification
parameters
The RF handheld device is
powered by bipolar RF at
10±0.5 [Watt]
Frequency: 1±0.05 [MHz]
Selectable output power level:
3 levels
Mechanical massage:
implemented by moving RF
electrodes. Speed: 50-100
RPM
Temperature sensors: RF
heating is automatically
deactivated when skin
temperature reaches 40
[oC]/104[0F]. The heating is
reactivated when
temperature decreases.
Treatment area: ~2.2 [cm2] /
0.34[In²]
External power supply: Input
100-240 [VAC], 50-60 [Hz],
Output 9[VDC], 1.5[A]
0800 923 4833
supportUK@sensica.com
For more information about
Sensilift or if your Sensilift is
broken, quits working, you
need more assistance or
would like to order additional
Base Gel please contact us
•

English
19
MD 04148 B0
•
Device Size and Weight:
140 [g], 173[mm] X 56.8[mm] X
53.1[mm] LxHxW
4.93[Oz], 6.8[In] X 2.23[In] X
2.09[In] LxHxW
Storage Instructions
Storage and Transport
Conditions
Temperature
Humidity
Non-condensingPressure
Operational Conditions
Temperature
20% to 80% RHHumidity
3,000 m.
Max
Operating
Altitude
-25 0C to 70 0C
(-130F to 1580F)
10% to 90% RH
at 550C/1310F
50C to 400C
(410F to 1040F)
Labeling
Model: ST100xxyyzzz
Power: 9 [V], 1.5 [A], 100-240
[VAC], 50-60 [Hz]
Double insulation
Consult Instructions
for use
Waste Electronic and
Electrical Equipment
Please read all
warnings and safety
precautions prior to use
Do not rinse sensiLift
under running water,
as it may cause device
malfunction. Keep dry

20

Español
21
© Todos los derechos reservados para EL Global Trade Ltd.
Índice de contenidos
Qué es Sensilift 22
Quién debería utilizar Sensilift
25
Cuándo no se debe utilizar Sensilift
26
26
28
29
30
30
30
31
Instrucciones de uso
31
Configuración del dispositivo
32
Cómo prepararse
33
Prueba preliminar
34
Cómo utilizar el dispositivo Sensilift
Protocolo de tratamiento recomendado
Zonas de tratamiento
Qué se debe esperar al utilizar Sensilift
Cuidados después del tratamiento facial
Limpieza y solución de problemas
Limpieza
Solución de problemas
Servicio de atención al cliente
Parámetros de las especificaciones del dispositivo
Posibles efectos secundarios
Descripción del dispositivo manual
Descripción de la interfaz de usuario
23
24
26
27
Quién no puede utilizar Sensilift - CONTRAINDICACIONES
Lo que debe hacer para evitar daños graves – ADVERTENCIAS
Lo que debe hacer para evitar otros daños – PRECAUCIONES
Descripción del dispositivo Sensilift
35
35
35
36
36
35

22
Español
Qué es Sensilift
Sensilift es un dispositivo de uso
doméstico para reducir las
arrugas, estirar la piel y renovar
la elasticidad de la piel.
Sensilift aporta un planteamiento
completamente nuevo al
rejuvenecimiento no invasivo de
la piel gracias a la tecnología
Dynamic RF™ patentada por
Sensica, combinando la RF
(Radio Frecuencia) clínicamente
probada, utilizada normalmente
por los médicos, con un masaje
facial avanzado.
La tecnología Dynamic RF™ es
una combinación de RF con
masaje facial que maximiza la
eficacia del tratamiento,
permitiendo que las múltiples
ondas de RF lleguen a un
mayor número de capas de la
piel obteniendo con ello los
mejores resultados posibles
duraderos, continuos y visibles.
termal altamente eficaz sobre el
tejido biológico.
Una de las principales causas de
las arrugas de la piel es la
reducción de la cantidad y la
calidad de las fibras de colágeno
en la dermis y la hipodermis.
Como resultado de la
resistencia del tejido al
movimiento de los electrones en
el campo de RF se genera calor.
A continuación, el calor
subcutáneo genera nuevo
colágeno y mejora el colágeno
existente, lo que resulta en una
reducción de las arrugas y en
una mayor elasticidad de la piel.
El tratamiento con Sensilift crea
el suficiente efecto termal para
inducir la reestructuración del
colágeno sin causar daños
termales ablativos en la
epidermis o la dermis.
Cómo funciona ?
Presentación de la nueva
tecnología Dynamic RF™
La Radio Frecuencia (RF) es
una forma de energía
electromagnética que se ha
estado utilizado en las clínicas
y centros de estética durante
mucho tiempo y que ha
resultado producir un efecto
Asegúrese de que lee
detenidamente esta
guía del usuario antes
de iniciar un tratamiento
con Sensilift. La guía del