RJ33N3AD0LG 7
6 CHARACTERISTICS (Drive method :1/30s frame accumulation)
T
A:+25℃, but +60℃for parameter No.4 and No.5.
Operating conditions :the typical values specified in “5 RECOMMENDED OPERATING CONDITIONS”.
Color temperature of light source :3200K, IR cut-off filter (CM-500,1 mmt)is used.
No.Parameter Symbol Note Minimum Typical Maximum Unit
1 Standard output voltage VO1 150 mV
2 Photo response non-uniformity PRNU 2 10 %
3 Saturation output voltage VSAT 3 400 mV
4 Dark output voltage VDARK 4 0.5 3.0 mV
5 Dark signal non-uniformity DSNU 5 0.5 2.0 mV
6 Sensitivity(Green channel)R(G)6 470 mV
7 Smear ratio SMR 7 -110 dB
8 Image lag AI 8 1.0 %
9 Blooming suppression ratio ABL 9 1000
10 Output transistor drain current IOD 12.0 mA
【Notes 】
1 The average output voltage of G signal under the uniform illumination. The standard exposure
conditions are defined as when VOis 150 mV.
2 The image area is divided into 10 × 10 segments under the standard exposure conditions. Each segment’s
voltage is the average output voltage of all pixels within the segment. PRNU is defined by
(Vmax - Vmin)/ VO, where Vmax and Vmin are the maximum and minimum values of each
segment’s voltage respectively.
3 The image area is divided into 10 × 10 segments. Each segment’s voltage is the average output voltages
of all pixels within the segment. Vsat is the minimum segment’s voltage under 10 times exposure of
the standard exposure conditions.
4 The average output voltage under non-exposure conditions.
5 The image area is divided into 10 × 10 segments under non-exposure conditions. DSNU is defined
by (Vdmax – Vdmin), where Vdmax and Vdmin are the maximum and minimum values of each
segment’s voltage respectively.
6 The average output voltage of G signal when a 1000 lux light source with a 90 % reflector is
imaged by a lens of F4, f50 mm.
7 The sensor is exposed only in the central area of V/10 square with a lens at F4, where V is the vertical
image size. SMR is defined by the ratio of the output voltage detected during the vertical blanking period
to the maximum output voltage in the V/10 square.
8 The sensor is exposed at the exposure level corresponding to the standard conditions. AI is defined by
the ratio of the output voltage measured at the 1st field during the non-exposure period to the standard
output voltage.
9 The sensor is exposed only in the central area of V/10 square, where V is the vertical image size. ABL
is defined by the ratio of the exposure at the standard conditions to the exposure at a point where
blooming is observed.
【Comment 】
Within the recommended operating conditions of VOD, VOFD of the internal output satisfies with ABL and VSAT.