manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Industrial Electrical
  8. •
  9. Siemens RHVE6 User manual

Siemens RHVE6 User manual

This manual suits for next models

9

Other Siemens Industrial Electrical manuals

Siemens RCD110 User manual

Siemens

Siemens RCD110 User manual

Siemens SIRIUS 3RV19 Series User manual

Siemens

Siemens SIRIUS 3RV19 Series User manual

Siemens 3VA9603-0QE00 User manual

Siemens

Siemens 3VA9603-0QE00 User manual

Siemens simovert masterdrives User manual

Siemens

Siemens simovert masterdrives User manual

Siemens 3VA9588-0VM10 User manual

Siemens

Siemens 3VA9588-0VM10 User manual

Siemens VT250 User manual

Siemens

Siemens VT250 User manual

Siemens SIVACON 8PS BD2 Series User manual

Siemens

Siemens SIVACON 8PS BD2 Series User manual

Siemens 3VA9088-0VM30 User manual

Siemens

Siemens 3VA9088-0VM30 User manual

Siemens 6300A User manual

Siemens

Siemens 6300A User manual

Siemens SENTRON SUPERSWITCH 3KL82 Series User manual

Siemens

Siemens SENTRON SUPERSWITCH 3KL82 Series User manual

Siemens SIMATIC NET OLM12M Manual

Siemens

Siemens SIMATIC NET OLM12M Manual

Siemens SINAMICS G130 User manual

Siemens

Siemens SINAMICS G130 User manual

Siemens 3VL9550-6CP30 User manual

Siemens

Siemens 3VL9550-6CP30 User manual

Siemens SIVACON 8PS LD User manual

Siemens

Siemens SIVACON 8PS LD User manual

Siemens MFKE Series User manual

Siemens

Siemens MFKE Series User manual

Siemens SIRIUS 3RH14 1 Series User manual

Siemens

Siemens SIRIUS 3RH14 1 Series User manual

Siemens 3VA9157-0PK11 User manual

Siemens

Siemens 3VA9157-0PK11 User manual

Siemens 3WX31 46-7C1 3 Series User manual

Siemens

Siemens 3WX31 46-7C1 3 Series User manual

Siemens 3RK1901-1MX00 User manual

Siemens

Siemens 3RK1901-1MX00 User manual

Siemens 3WN1 User manual

Siemens

Siemens 3WN1 User manual

Siemens 3WX3666-8JA0 Series User manual

Siemens

Siemens 3WX3666-8JA0 Series User manual

Siemens 3RV1986-3AP3 User manual

Siemens

Siemens 3RV1986-3AP3 User manual

Siemens FDCL181 User manual

Siemens

Siemens FDCL181 User manual

Siemens 3VA9177-0VF40 User manual

Siemens

Siemens 3VA9177-0VF40 User manual

Popular Industrial Electrical manuals by other brands

Murata GRM0335C1E3R9BA01 Series Reference sheet

Murata

Murata GRM0335C1E3R9BA01 Series Reference sheet

ARCAIR N6000 Automatic System Safety and operating instructions

ARCAIR

ARCAIR N6000 Automatic System Safety and operating instructions

Murata GRM31CR61E106MA12 Series Reference sheet

Murata

Murata GRM31CR61E106MA12 Series Reference sheet

Murata GQM2195C2A9R1CB01 Series Reference sheet

Murata

Murata GQM2195C2A9R1CB01 Series Reference sheet

MFJ MFJ-918 quick start guide

MFJ

MFJ MFJ-918 quick start guide

Abtech HVJB Series Installation, operation & maintenance instructions

Abtech

Abtech HVJB Series Installation, operation & maintenance instructions

Murata GRM0335C1H8R1DA01 Series Reference sheet

Murata

Murata GRM0335C1H8R1DA01 Series Reference sheet

SAF-HOLLAND CBX 5415.5 Installation and operation manual

SAF-HOLLAND

SAF-HOLLAND CBX 5415.5 Installation and operation manual

Eaton Ulusoy HMH24-04 user manual

Eaton

Eaton Ulusoy HMH24-04 user manual

Murata GJM0335C1E4R4BB01 Series Reference sheet

Murata

Murata GJM0335C1E4R4BB01 Series Reference sheet

Newlong NP-7H NSTRUCTION MANUAL/PARTS LIST

Newlong

Newlong NP-7H NSTRUCTION MANUAL/PARTS LIST

Stahl 8575/12 operating instructions

Stahl

Stahl 8575/12 operating instructions

SI Pegasus installation instructions

SI

SI Pegasus installation instructions

Murata GRM1555C1H2R7CA01 Seies Reference sheet

Murata

Murata GRM1555C1H2R7CA01 Seies Reference sheet

Murata GRM0225C1E6R4BA03 Series Reference sheet

Murata

Murata GRM0225C1E6R4BA03 Series Reference sheet

Cooper Power Systems VXE15 Installation and operation instructions

Cooper Power Systems

Cooper Power Systems VXE15 Installation and operation instructions

S&C Vista SD manual

S&C

S&C Vista SD manual

Murata GRM0335C2A7R3CA01 Series Reference sheet

Murata

Murata GRM0335C2A7R3CA01 Series Reference sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Installation Instructions / Instructivo de Instalación
Item: RHVE6
RHVE12
RHVE24
RHVEEM6
RHVEEM12
RHVEEM24
For Use With Frame EG
Para Usar Con Caja Base EG
s
Rotary HandleOperator Variable Depth
Accionamiento giratorio con extensión
Commande rotative sur porte avec
1 / 7
Use only with Siemens certified components.
Utilizar únicamente con componentes certificados de Siemens.
A utiliser uniquement avec les composants certifiés Siemens.
Turn off and lock out all power supplying this device before
working on this device.
Replace allcovers before powersupplying this deviceis
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement depouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves. Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
Turn off and lock out all power supplying this device before
working on this device.
Replace allcovers before powersupplying this deviceis
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement depouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves. Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
IL01219051EH03
Only
[ Solamente ]
A
C
D
B
E
O / OFF
1Disconnect Voltage.
Place Handle in OFF Position.
[Desconecte Voltaje.
Coloque la manija en la posición de O /OFF ]
Ø = .110“
[ Ø = 2.8 mm ]
Ø = .188“
[ Ø = 5 mm ]
Ø = 1.375“
[ Ø = 35 mm ]
RHVE6
RHVE12
RHVE24
RHVEEM6
RHVEEM12
RHVEEM24
FG
807908A02
2 / 7
807908A02
2Place both handles in the OFF / O position.
[ Coloque ambas manijas en la posición de OFF/ O.]
3a
2b
B
A
2 X
10 lb. In.
[1.1 Nm]
B
Only / [ Solamente ]
RHVE244X
RHVEEM244X
2c
Breaker
Switch
In / A
Ir / A
Ue / V
Icu / Ka
Ics / Ka
Poles °C
Wire Size
Wire Size
In / A
Ir / A
3c
3b
G
3
F
OFF / O
2a
OFF / O
3 / 7
5Test full range of motion.
[ Pruebe la gama completa del movimiento.]
Remove covers to access breaker adjustments and Push-To-Trip
Button.
[ Quite las cubiertas para tener acceso al botón de disparo y
ajustes del interruptor. ]
6
807908A02
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this deviceis
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement depouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves. Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this deviceis
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement depouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves. Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
Twist
[ Torcedura ]
Twist
[ Torcedura ]
Option
[ Opción ]
F
44a
4b
OK
If no full motion,
call Customer Support
[ Si no hay movimiento completo,
llame a servicio de cliente. ]
5a
5b
7
Option
[ Opción ]
Customer supplied sealing wire.
[ Alambre del lacre provisto por cliente. ]
7a 7b
1.5”
MAX
FOR MOUNTING THREE POLE
BREAKER.
DRILL AND TAP FOUR M4 X .7 DEEP
HOLES INTO THE MOUNTING PLATE
FOR MOUNTING FOUR POLE BREAKER.
DRILL AND TAP SIX M4 X .7 DEEP
HOLES INTO THE MOUNTING PLATE
[ PARA MONTURA DE INTERRUPTOR DE
3 POLOS.
TALADRE Y HAGA ROSCA DE M4 X .7 A
CUATRO AGUJEROS EN LA PLACA DE
MONTAJE PARA MONTURA DE
INTERRUPTOR DE 4 POLOS.
TALADRE Y HAGA ROSCA DE M4 X .7 A
SEIS AGUJEROS EN LA PLACA DE
MONTAJE. ]
4 Pole
[ 4 Polos ]
3 Pole
[ 3 Polos ]
“B”
“A”
Breaker
[ Interruptor ]
4.00”
[ 101.6 mm ]
.85”
[ 21.59 mm ]
1.85”
[ 47 mm ]
3.00”
[ 76.2 mm ]
4 / 7
807908A02
Mounting Plate
[ Placa de Montaje ]
A
B
.16”
[ 4.06 ]
1.28”
[ 32.51 ]
1.00”
[ 25.4 ]
3.81”
[ 96.77 ]
5.50”
[ 139.7 ]
B
A
1.00”
[ 25.4 ]
Mounting Plate
[ Placa de Montaje ]
LINE
[ LINEA ]
LOAD
[ CARGA ]
5.62”
[ 142.75 ]
“D” See Step 8
[ “D” Ver Paso 8 ]
4.40”
[ 111.76 ]
2.77”
[ 70.36 ]
1.57”
[ 39.88 ]
3.00”
[ 76.2 ]
7.05
[ 179.07 ]
5 / 7
807908A02
Insert shaft.
Make sure pins are parallel to the handle.
[ Inserte el Eje.
Cerciórese de que lospernos estan
parallel la manija ]
E
Front of Panel Cover
[ Vista Frontal de Tapa]
9
Cut shaft to length.
[ Corte el Eje a este largo. ]
8
8Enclosure Shaft Modification
[ Modificación del Eje del Cajón ]
Breaker Mounting Plate
[ Placa de Montaje Interruptor ]
D
L = D – 3.65”
[ L = D – 93 mm ]
Measurement
[ Medida ]
Cut here
[ Corte aquí ]
L
Drill hole in shaft.
[ Taladre agujero en Eje. ]
Ø.110”
[ 2.8 mm ] .25”
[ 6.4 mm ]
45-55 lb. in.
[ 5.1 – 6.2 Nm ]
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this deviceis
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement depouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves. Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this deviceis
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement depouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves. Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
8a
9a
8c
8b
9C
E
E
C
F
A
Insert cotter pin through handle and shaft
[ Inserte chaveta a través de la manija y eje ]
D
10
10a
10b
10c
13
13
6 / 7
807908A02
Test for full range of motion
[ Pruebe la gama completa de movimiento ]
14
2 X
10-13 lb. in.
[ 1.1-1.5 Nm ]
Inside of door
[ Interior de la puerta ]
Viewed from inside of cover.
[ Vista desde el interior de la
cubierta. ]
Ø.188”
[ 5 mm ]
Ø1.375”
[ 35 mm ]
Transferred paint mark
[ Marca de pintura
transferida ]
0.75”
[ 19mm ]
Ø.188”
[ 5 mm ]
0.75”
[ 19mm ]
0.75”
[ 19mm ]
0.75”
[ 19mm ]
.
.
12
11
Apply paint.
[ Aplique pintura ]
Place enclosure upright
[ Posicione el Cajón parado ]
Close door and transfer paint to inside of door
[ Cierre la puerta y transfiera la pintura al interior de la puerta ]
10c
10a
10b
If no full motion,
call Customer Support
[ Si no hay movimiento completo,
llame a servicio de cliente. ]
OK
16
Option
[ Opción ]
15c
15a
15b
TRIP
RESET
Subject to change without prior notice © Siemens Industry, Inc. 2010
Siemens Industry, Inc. , Norcross, GA 30092 U.S.A. 7 / 7
Technical Support: Toll Free: 1-800-241-4453 Internet: www.usa.siemens.com/powerdistribution
IL01219051EH03
807908A02
14a
Ø .188 - .340”
[ Ø 4.78 - 8.63 ]
OK
If no full motion,
call Customer Support
[ Si no hay movimiento completo,
llame a servicio de cliente. ]
14b
O / OFF
I / ON
Test for full range of motion
[ Pruebe la gama completa de movimiento ]
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this deviceis
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement depouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves. Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
Turn off and lock out all power supplying this device before
working on this device.
Replace all covers before power supplying this deviceis
turned on.
Couper l'alimentation de l'appareil et barrer avant de
travailler.
Remplacez touts les couverts avant que
l'approvisionnement depouvoir soit alimenté.
Tensión peligrosa.
Puede causar la muerte o lesiones graves. Tension dangereuse.
Danger de mort ou risque de blessures graves.
Hazardous Voltage.
Will cause death or serious injury.
Desenergice totalmente antes de instalar o darle servicio.
Reemplace todas las barreras y cubiertas antes de
energizar el interruptor.
15