
Contents
139-2021.9 / 07 NXAIR M 5
10.18 Plugging on the low-voltage connector..........................................................................................................57
10.19 Taking the withdrawable circuit-breaker out of the panel...............................................................................59
10.20 Inserting the withdrawable circuit-breaker in a panel.....................................................................................64
11 Operating the disconnecting panel.......................................................................................................73
11.1 Control elements at the front side of the panel ..............................................................................................73
11.2 Position indicators visible on high-voltage door.............................................................................................73
11.3 Access to compartments ...............................................................................................................................74
11.4 Opening or closing the high-voltage door ......................................................................................................74
11.5 Racking the withdrawable disconnector link ..................................................................................................74
11.6 Removing or plugging on the low-voltage connector.....................................................................................76
11.7 Taking the withdrawable disconnector link out of a panel or inserting in a panel...........................................76
11.8 Earthing or de-earthing the feeder.................................................................................................................76
12 Operating the metering panel ................................................................................................................77
12.1 Control elements at the front side of the panel ..............................................................................................77
12.2 Position indicators visible on high-voltage door.............................................................................................77
12.3 Access to compartments ...............................................................................................................................78
12.4 Opening or closing the high-voltage door......................................................................................................78
12.5 Racking the withdrawable metering part........................................................................................................78
12.6 Removing or plugging on the low-voltage connector.....................................................................................78
12.7 Taking the withdrawable metering part out of a panel or inserting in a panel ................................................79
12.8 Replacing protection fuse-links......................................................................................................................79
13 Operating the circuit-breaker panel with HV HRC fuse.......................................................................83
13.1 Control elements at the front side of the panel ..............................................................................................83
13.2 Position indicators visible on high-voltage door.............................................................................................84
13.3 Access to compartments ...............................................................................................................................84
13.4 Opening or closing the high-voltage door ......................................................................................................84
13.5 Racking the withdrawable part.......................................................................................................................84
13.6 Closing or opening the circuit breaker / fuse combination .............................................................................85
13.7 Discharging or charging the closing spring....................................................................................................85
13.8 Earthing or de-earthing the feeder manually..................................................................................................85
13.9 Removing the low-voltage connector.............................................................................................................85
13.10 Plugging on the low-voltage connector..........................................................................................................87
13.11 Taking the withdrawable circuit-breaker / fuse combination out of a panel or inserting in a panel.................89
13.12 Replacement of HV HRC fuse-links...............................................................................................................89
14 Operating the circuit-breaker panel for double-busbar system.........................................................99
14.2 Position indicators visible on high-voltage door, panel A.............................................................................101
14.3 Position indicators visible on high-voltage door, panel B.............................................................................101
14.4 Access to compartments .............................................................................................................................101
14.5 Opening or closing the high-voltage door ....................................................................................................102
14.6 Positions of the withdrawable circuit-breaker...............................................................................................102
14.7 Racking the withdrawable circuit-breaker....................................................................................................102
14.8 Closing or opening the circuit-breaker.........................................................................................................102
14.9 Discharging or charging the closing spring..................................................................................................102
14.10 Earthing or de-earthing the feeder...............................................................................................................103
14.11 Removing or plugging on the low-voltage connector...................................................................................103
14.12 Taking the withdrawable part out of a panel or inserting in a panel.............................................................103
15 Operating the removable voltage transformers.................................................................................104
15.2 Opening or closing the high-voltage door ....................................................................................................104
15.3 Racking the removable voltage transformers to service position.................................................................105
15.4 Racking the removable voltage transformers to test position ......................................................................109
15.5 Taking the removable voltage transformers out of the panel.......................................................................113
15.6 Inserting the removable voltage transformers in a panel.............................................................................117
15.7 Replacing protection fuse-links....................................................................................................................122
16 Verifying safe isolation from supply...................................................................................................125
16.1 Application of voltage indicators ..................................................................................................................125
16.2 Overview of voltage indicating systems.......................................................................................................125
16.3 LRM system overview..................................................................................................................................126
16.4 Verifying LRM-ST voltage indicator .............................................................................................................127
16.5 Verifying safe isolation from supply with the LRM device system................................................................128
16.6 CAPDIS and VOIS systems overview..........................................................................................................129
16.7 Verifying safe isolation from supply with the CAPDIS or VOIS device system ............................................132
16.8 Supplier information.....................................................................................................................................132