manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sierra
  6. •
  7. Measuring Instrument
  8. •
  9. Sierra RedySmart Series User manual

Sierra RedySmart Series User manual

QUICK START GUIDE
RedySmartTM Series
1 | RedySmart_v1_2020
Safety and General Information
1. For safe operation, please consider the process and ambient conditions for which the device is designed and specified at the time of
delivery. This information can be found on the data label on the instrument housing and in the Instruction Manual.
2. Do not remove the electronics housing to prevent damage to the unit. A damaged hologram seal will void the warranty.
3. There are no serviceable parts inside the unit. Repairs must be performed by qualified personnel only.
Installation and Electrical Connection
1. Do not use Teflon® tape or liquid sealing on the process connections.
2. Please ensure that the piping is clean and purged before you connect the flow meter.
3. The gas used must be clean and dry.
4. For particle protection, we recommend to install our 50µm filter at the inlet.
5. It is recommended that the user checks the device on a regular schedule to ensure that it is leak free as both metal and elastomeric seals,
gaskets, O-rings and valve seats may change with age, exposure to process gas.
Note Your Sierra sales representative can help you to source suitable O-rings, elastomeric seals, fittings and filters.
6. Please refer to the RedySmart Instruction Manual for detailed instruction on mounting orientation and location.
7. Please verify a proper electrical connection. The device must be grounded. The supply voltage is 18-30 vdc (typically ±50 mV).
Note The current consumption depends on the instrument version. Please refer to the information in the Instruction Manual.
This Quick Start Guide for the RedySmart Series Thermal Mass Flow
Meters and Controllers gives easy set up and installation instructions.
For complete instructions, please download and read the RedySmart
Series Instruction Manual. Before installing meter, follow the steps below.
Step 1. Download Instruction Manual
To get technical information, download the RedySmart Series
Instruction Manual at sierrainstruments.com/redysmart-manual
Step 2. Download FREE Software
Download the most current RedySmart product software at
sierrainstruments.com/redysmart-software. Use the included cable
(if ordered) to connect the meter to your computer.
IMPORTANT! If you do not have an internet connection, you must
download the software to a USB stick or other storage device.
Default Factory Settings
Modbus RTU
Communication speed 9600 Baud
Data bits 8
Stop bits 2
Parity None
Node address 247
Profibus (optional)
Node address 125
When using several devices simultaneously the user has to
configure each device with an individual address!
Profinet / EtherCAT (optional)
Name RedySmart SIP
IP address 0.0.0.0
Further information on the device configuration can be found in the
Instruction Manual.
2 | RedySmart_v1_2020
Sub D Plug Pin Assignments Modbus RTU, Power Supply & Analog Signals (Male)
PIN Assignment Description
1Common (-) GND analog signals
2 Supply 0 Vdc 0 vdc supply voltage
3Supply +24 Vdc +24 vdc supply voltage
4Output (+) Analog output, measured value
5Setpoint (+) Analog input, setpoint
6Tx+ RS-485 Output (Y)
7Tx- RS-485 Output (Z)
8 Rx- RS-485 Input (B)
9Rx+ RS-485 Input (A)
Sub D Plug Pin Assignments Profibus (Female)
PIN Assignment Description
1Not connected _
2Not connected _
3RxD/TxD-P Data transmit / receive; data wire B
4CNTR-P Repeater control signal (RTS)
5DGND Ground for data signals and VP
6 VP / +5V Power supply +5V
7Not connected _
8RxD/TxD-N Data transmit / receive; data wire A
9Not connected _
Rj45 Socket Pin Assignments Profinet / Ethercat (Female)
PIN Assignment Wire Color
1Data (Tx+) Yellow
2 Data (Tx-) Orange
3Data (Rx+) White
4Not connected _
5Not connected _
6 Data (Rx-) Blue
7Not connected _
8Not connected _
5
4
3
2
1
9
8
7
6
5
4
3
2
1
9
8
7
6
Pin Assignment
All connection diagrams can be found in the Instruction Manual. Please also refer to the additional Digital
Communication Instruction Manual.
Warning! Always disconnect the power supply before working on the plugs.
18
3 | RedySmart_v1_2020
LED Operating Status
Power: The green LED lights up when the unit is supplied with the correct power supply voltage and is ready for operation.
TxRx : The yellow LED flashes when the device is communicating on the digital Modbus RTU interface.
Alarm: If the red LED flashes, there is a malfunction. If the LED is lit continuously, there may be a serious problem.
Disconnect the supply voltage and reconnect the device. If the LED is still lit, the unit must be returned for repair.
Power
Tx Rx
Alarm
Note The EtherCat/Profinet devices have an extended LED operating status. Please refer to the Instruction Manual.
COM
PWR
ALM
Toxic, Flammable Gases and ATEX
Warning! In the case of toxic and flammable gases, the respective safety guidelines in each country must be followed.
The RedySmart devices are not approved for use in Ex-zones. In the case of flammable and toxic gases, fittings and pipes
intended for that purpose must be used. The responsibility for safe operation lies with the designer of the facilities. The
devices must not be used for explosive mixtures (ATEX, detonating gas, consisting of O2and H2).
Limited Warranty Policy – Register Online
All Sierra products are warranted to be free from defects in material and workmanship and will be repaired or replaced at no charge to Buyer,
provided return or rejection of product is made within a reasonable period but no longer than three (3) years for calibration and non-calibration
defects, from date of delivery.
To assure warranty service, customers must register their products online on Sierra’s website. Online registration at of all of your
Sierra products is required for our warranty process. Read complete warranty policy at sierrainstruments.com/warranty.
Note: Please dispose of the device in an environmentally friendly way (recycle).
5 Harris Court, Building L / Monterey, CA 93940 / USA
USA: 800.866.0200 / 831.373.0200
Europe: +31.72.5071400
China: +8621 5879 8522
Email: techsupport@sierrainstruments.com or [email protected]
For global locations, visit: sierrainstruments.com/locations
www.sierrainstruments.com
CONTACT SIERRA
4 | RedySmart_v1_2020 99-2173
We Understand Flow is Tough.
We can solve this together.
sierrainstruments.com/RedySmart

Other Sierra Measuring Instrument manuals

Sierra MaxTrak 180 Series User manual

Sierra

Sierra MaxTrak 180 Series User manual

Sierra Innova-Sonic Portable 210 Series User manual

Sierra

Sierra Innova-Sonic Portable 210 Series User manual

Sierra 830 Series User manual

Sierra

Sierra 830 Series User manual

Sierra InnovaMass 240i Series User manual

Sierra

Sierra InnovaMass 240i Series User manual

Sierra M100L User manual

Sierra

Sierra M100L User manual

Sierra TM100 User manual

Sierra

Sierra TM100 User manual

Sierra 830M User manual

Sierra

Sierra 830M User manual

Sierra Innova-Sonic 205 Programming manual

Sierra

Sierra Innova-Sonic 205 Programming manual

Sierra InnovaSonic 205i User manual

Sierra

Sierra InnovaSonic 205i User manual

Sierra Innova-Sonic 205 User manual

Sierra

Sierra Innova-Sonic 205 User manual

Sierra InnovaMass 240 series User manual

Sierra

Sierra InnovaMass 240 series User manual

Sierra Smart-Trak 100 series User manual

Sierra

Sierra Smart-Trak 100 series User manual

Sierra InnovaSonic 207i BACnet User manual

Sierra

Sierra InnovaSonic 207i BACnet User manual

Sierra Smart-Trak IM-100 Series User manual

Sierra

Sierra Smart-Trak IM-100 Series User manual

Sierra QuadraTherm 640i Series User manual

Sierra

Sierra QuadraTherm 640i Series User manual

Sierra Smart-Trak 100 series User manual

Sierra

Sierra Smart-Trak 100 series User manual

Sierra InnovaMass 240 series User manual

Sierra

Sierra InnovaMass 240 series User manual

Sierra Smart-Trak 100 series User manual

Sierra

Sierra Smart-Trak 100 series User manual

Sierra RedyCompact Series User manual

Sierra

Sierra RedyCompact Series User manual

Sierra BioTrak 645i User manual

Sierra

Sierra BioTrak 645i User manual

Sierra QuadraTherm 640i Series User manual

Sierra

Sierra QuadraTherm 640i Series User manual

Sierra TM500 User manual

Sierra

Sierra TM500 User manual

Sierra 780 Series User manual

Sierra

Sierra 780 Series User manual

Sierra Smart-Trak 100 series User manual

Sierra

Sierra Smart-Trak 100 series User manual

Popular Measuring Instrument manuals by other brands

Activinsights GENEActiv Instructions for use

Activinsights

Activinsights GENEActiv Instructions for use

Conrad P3 operating instructions

Conrad

Conrad P3 operating instructions

Hach BioTector B3500C user manual

Hach

Hach BioTector B3500C user manual

ARDETEM PECA 5 user manual

ARDETEM

ARDETEM PECA 5 user manual

Wise T110 instruction manual

Wise

Wise T110 instruction manual

WIKA DPG40 operating instructions

WIKA

WIKA DPG40 operating instructions

Ecolab Lub-O-Mat 2.5 operating instructions

Ecolab

Ecolab Lub-O-Mat 2.5 operating instructions

Johnson Controls AD-1272 Technical bulletin

Johnson Controls

Johnson Controls AD-1272 Technical bulletin

Sea-Bird Scientific SUNA V2 user manual

Sea-Bird Scientific

Sea-Bird Scientific SUNA V2 user manual

Nikon Black Range X 4K instruction manual

Nikon

Nikon Black Range X 4K instruction manual

Hauck OMG SERIES instructions

Hauck

Hauck OMG SERIES instructions

TESTO 325M instruction manual

TESTO

TESTO 325M instruction manual

eGauge EDC quick start guide

eGauge

eGauge EDC quick start guide

KROHNE OPTIMASS 1400 quick start

KROHNE

KROHNE OPTIMASS 1400 quick start

PASCO PASPORT PS-2108 quick start guide

PASCO

PASCO PASPORT PS-2108 quick start guide

OWL OWLTrek II WTO2-S13 Operation guide

OWL

OWL OWLTrek II WTO2-S13 Operation guide

Dr.Fodisch MGA 12 Operation manual

Dr.Fodisch

Dr.Fodisch MGA 12 Operation manual

edc HAZ-DUST IV HD-1004-S quick start guide

edc

edc HAZ-DUST IV HD-1004-S quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.