SilverStar Show Wash 120 User manual

User Manual
www.yajiang.com
Version 1.0
2005 11 19
年月日
as

◆
◆
◆
◆℃
◆
Avoid shaking of strong impacts to the equipment.
Never lift the equipment by holding it at the head or arms. Always use the handles on
the base.
DO NOT turn on the lamp at short intervals as this will reduce the lamp's life.
The maximum ambient temperature of the housing is ta=45 . If the temperature is in
excess of this the thermal switch will shut off the power.
When transferring the product, it is advisable to use the original packaging that the unit
left the factory in.
REAR PANELOFTHE BASE
The head must be locked for transportation-the tilt lock button is pushed and the pan
lock/unlock lever is in lock position. To unlock the head, press the tilt unlock button and
move the pan lock/unlock lever to unlock position.
DESCRIPTION
5 Pin DMX output
5 Pin DMX input
Live fuseholder
Power switch
Power cord
Moving head
Tilt lock button
Pan lock button
Handel
3-pin DMX output
3-pin DMX input
··
2

INTRODUCTION
IMPORTANT
SAFETY WARNING
ATTENTION
This equipment is produced in accordance with CE standards and conforms to the
international standard DMX512 protocol.
On receiving this product, please carefully check that there has been no damage caused in
transportation and that the following parts are enclosed:
1 1200WWASH MOVING HEAD
1 SIGNAL CABLE
1 USER MANUAL
1 SAFETY CABLE
2 CLAMPS
This product must be installed by a qualified professional
All operation and maintenance must be carried out in accordance with this user manual.
Keep this device away from any form of water or moisture at all times.
Always disconnect the power before attempting to open the equipment housing or carrying
out any maintenance.
Avoid looking directly into the light source (especially those who suffer from epileptic fits)
DO NOT touch the equipment casing during operation due to high temperatures of the metal
and plastic housing.
This equipment is designed for indoor use only.
This product left our premises in perfect condition. In order for safe operation and to
maintain the original condition, the user must always follow the instructions and safety warnings
described in this usermanual.
The manufacturer cannot accept liability for any resulting damages caused by non-
observance of this manual or any unauthorized modifications to the equipment and are not
subject to warranty.
Always make sure that the equipment is OFF before connecting the power cables.
Always make sure that the power cable is never cut or damaged by sharp edges. It is
advisable to check the state of the power cable from time to time.
DO NOT connect this equipment to a dimmer rack.
This device falls under Protection Class I. Therefore it is essential that theyellow/green wire
must be earthed.
If during transportation or storage the equipment has gone through drastic temperature
changes, it is advisable to allow some time for the equipment to first adjust to room
temperature before operation.
Never turnon the equipment without a lamp
×
×
×
×
×
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
◆
BEFORE OPERATION PLEASE CONFIRM THAT THE POWER SUPPLY STATED ON THE REAR
PANELOFTHIS UNIT IS THE SAMEAS THE SUPPLIED MAINS POWER INYOURAREA.
READ THIS USER MANUALCAREFULLYBEFORE OPERATION
··
1

Color wheel 1
Lamp chamber
Coluor wheel 2
Thermostat
Ignitor
Inside fresnel lens
CMY/CTO
filter module
Lamp cover
··
3
Description of the fixture

DIMENSIONS
Pan540°
Tilt 280°
489 mm
151 mm
585 mm
602 mm
525mm
506 mm
··
4

LAMPADJUSTMENT
REPLACING LAMP
CAUTION:
AB
AB.
IMPORTANT:
ALWAYS SWITCH OFF AND UNPLUG AT THE MAINS BEFORE
INSTALLINGTHE LAMP
1. Disconnect thepower andall theunitto coolforatleast10minutes.
2. Loosen screws indicated & on the lamp cover at the back of the head.
3. Gently pulland remove the lamp cover andlampholderfromthe head.
4. Holding the lamp by its ceramic base, carefully pull the lamp straight out of the lamp
socket.
5. Holding the new lamp by its ceramic base, gently insert the lamp in to the lamp socket.
6. Reinsert the lamp cover and lamp holder and tighten screw &
lways make sure that the lamp is installed tightly into the lamp socket.
谹
O NOT install a lamp other than that specified in this user manual.
谼
O NOT touch the glass area of the lamp with bare hands.
谼
When this product left the factory, the lamp holder was calibrated here. However, due to
the possibility of small deviations between lamps, fine adjustments after replacement may
improve light output.
1. Turn on the lamp and operate with white beam (i.e. no effects)
2. Open the shutter and the iris with the dimmer intensity at 100%.
3. Focus the light beam on a flat surface (i.e. wall/floor)
4. Center the hot-spot (the brightest part of the image) using the 3 adjustment screws
, & .
5. Once the hot-spot has been centered, remove the hot-spot and balance the light
output by turning the adjustment screws a quarter-turn clockwise one after another. If
the hot-spot cannot be located, adjust the lamp until the light output is evenly
“”
“” “”
“”
XY Z
LampLamp holder
Fixed the lamp holder
ofscrew(A,B)
Adjust screw (X,Y,Z)
INSTALLATION
··
5

··
6
5, Inserting / Exchanging colours
Danger of fire! When installing the device, make sure there is no highly in ammable
material (decoration articles, etc.) In between a distance of min 1.3M.
CAUTION! Use 2 appropriate clamps to rig the fixture on the truss. Follow the instructions
mentioned at the bottomof the base. Make sure that thedevice is fixed properly! Ensure that
the structure (truss) to which you are attaching the fixture is secure.
The installation of the fixture has to be built and constructed in a way that it can hold 10
times the weight for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. And
appropriate catch net. This secondary safety attachment must be constructed in a way that
no part of the installation can fall down if the main attachment falls.
The moving heads can be placed directly on the stage or rigged in any orientation on a truss
without altering its operation characteristics:
Open the bottom cover of the moving head by loosening the 4 quarter-turn fasteners on the
top cover and follow the instruction s below:
Gently bend out the colour module to release it from the fixative holes and eject it from the
pressing snap. Put the new colour module back under the pressing snap and push it to the 3
fixative notches.
CAUTION: Make sure the colour modules be locked well when you push it to fixative
notches.
For overhead use, always install a
safety-rope that can hold at least 10
times the weight of the fixture. You
must only use safety ropes with
screw-on carabines. Pull the safety
rope through the two apertures on the
bottom of the base and cover the
trussing system etc. Insert the end in
the carabine and tighten the fixation
screw.
Colour wheel
Colour module
Colours
Pressing snap
Colour module
6, Rigging the fixture
Clamp
Omega Holder
Plate
Safty-rope
Nut Ring

The fixture is equipped with both 3-pin and 5-pin XLR sockets for DMX input and output.
The sockets are wired in parallel.
DMX-OUTPUT DMX-input
1
2
3
4 -
5 -
- Ground
- Signal (-)
- Signal (+)
Free
Free
Occupation of the XLR-connection:
XLR mounting-socket: XLR mounting-plug:
Caution:
At the last fixture, the DMX-cable has to be terminated with a terminator.
Solder a 120 resistor between Signal (-) and Signal (+) into a 3-pin XLR-plug and plug
it in the DMX-output of the last fixture.
Ω
5Pins canon( )plug
Pin 1: GND(SCREEN)
Pin 2: Signal(-)
Pin 3: Signal(+)
Pin 4: N/C
Pin 5: N/C
3
Pin 1: GND(SCREEN)
Pin 2: Signal(-)
Pin 3: Signal(+)
Pins canon(socket)
5Pins canon(socket)
Pin 1: GND(SCREEN)
Pin 2: Signal(-)
Pin 3: Signal(+)
Pin 4: N/C
Pin 5: N/C
3 plug
Pin 1: GND(SCREEN)
Pin 2: Signal(-)
Pin 3: Signal(+)
Pins canon( )
The transform of the controller line of 3 pins and 5 pins (plug and socket)
DMX-512 connection/connection between fixtures
Possible omega holder 4 positions:
5
120
Ω
··
7

DMX512 CHANNELFUNCTION
Channel
Function
··
8

Channel 1 Pan movement
:
Pan movement by 540
°
Function
Value
255 100
Channel 2 Pan fine
:
00.0
Fine controlof
pan movement
proportional
Value
255 100
00.0
Function
Value
255 100
00.0
··
9

Channel 4 Tilt Fine
:
Channel 5 Pan & Tilt speed
:
Channel 6 Lamp on/off, Reset
:
240~255
230~239
140~229
128~139
0~127
Noeffect
Lamp off after 3
seconds
Noeffect
Lamp on and Reset
Noeffect
94~100
90~94
55~90
50~55
0~50
Fine control of
Tilt movement
proportional
Function
Value
255 100
00.0
From fast to slow
FunctionValue
255 100
00.0
Slow
Value Function
Fast
Fast
··
10

Channel 9 Cyan
:
0~100% Cyan
proportional
Channel 7 Color wheel 1
:
197~255
182
169
156
143
130
117
104
83 97~
69 82~
56 68~
42 55~
28 41~
14 27~
013~
Forward rainbow effect
from slow to fast
UV filter
6000KTemperature filter
Deep Green
Deep Red
White
UV filter
Deep Green
Orange
Deep Blue
Deep Red
White
77~100
71
66
61
56
51
46
41
32~28
27 32~
22~27
16~22
11~16
5~11
0~5
Channel 8 Color wheel 2
:
197~255
182
169
156
143
130
117
104
83 97~
69 82~
56 68~
42 55~
28 41~
14 27~
013~
Forward rainbow effect
from slow to fast
White
Red ring
Bluedot
Yellow ring
UT Filter / Orange
Green / Orange
Blue/Yellow/Magenta/
Orange White
77~100
71
66
61
56
51
46
41
32~28
27 32~
22~27
16~22
11~16
5~11
0~5
Blue/Yellow/Magenta/
Orange
Green / Orange
UT Filter/ Orange
Yellow ring
Bluedot
Value Function
Value Function
Value Function
255 100
00.0
··
11

Channel 12 3200K CTO
:
Channel 10 Magenta
:
0~100%Magenta
proportional
Channel 11 yellow
:
0~100%Yellow
Proportional
Value Function
255 100
00.0
Value Function
255 100
0 0.0
Value Function
··
12

Channel 13 CMY+CTO Marcos
:
Channel 15: Fresnel Opening
200~207
192~199
168~175
80~87
72~79
64~71
56~63
48~55
40~47
32~39
24~31
16~23
8~15
0~7
78.5~81
75~78
66~68.5
31~34
28~31
25~28
22~25
19~21.5
15.5~18.5
12.5~15
10.5~12
6.5~10
3.5~6
0~3
Marco 25
Marco 24
Marco 21
Marco 10
Marco 9
Marco 8
Marco 7
Marco 6
Marco 5
Marco 4
Marco 3
Marco 2
Marco 1
No function
88~95 34.5~37 Marco 11
96~103 37.5~40 Marco 12
104 1~11 40.5~43.5 Marco 13
112~119 44~46.5 Marco 14
120~127 47~50 Marco 15
128~135 50~53 Marco 16
136~143 53.5~56 Marco 17
144~151 56.5~59 Marco 18
152~159 59.5~62 Marco 19
160~167 62.5~65.5 Marco 20
176~183 69~71.5 Marco 22
184~191 72~75 Marco 23
208~215 81.5~84 Marco 26
216~223 84.5~87.5 Marco 27
224~231 88~90.5 Marco 28
232~239 91~93.5 Marco 29
240~247 94~97 Marco 30
248~255 97~100 Marco 31
Channel 14 CMYfilter + CTO speed assigning
:
From fast to slow
step
FunctionValue
255 100
00.0
Value Function
Internal Fresnel
Opening--Fromclose
to open-light maxmode
FunctionValue
255 100
00.0
··
13

Channel 16 Zoom
:
Channel 17 Strobe
:
Channel 18 Dimmer
:
224~255
160~191
128~159
64~95
0~31
Shutter Open speedy
Shutter open dimmer
proportional
(
)
Randomstrobefrom
slow to fast
Shutter close
88~100
75.5~87.5
63~75
37.5~49.5
0~12
32~63 12.5~24.5
96~127 Shutter open (dimmer
proportional)
50~62.5
192~223 Randomstrobefrom
slow to fast
25~37
Max--proportional
Min.
FunctionValue
255 100
00.0
Dimmerintensity
from 0 to 100%
proportional
FunctionValue
255 100
00.0
FunctionValue
··
14

10
°
6670 1668 741 417 Foot-candles(center)
71800 17950 7980 4490 LUX(center)
Beam
°
angle 10 -LightMax mode
Beam opening(m)
5
0.87 10
1.75 15 20 Distance(m)
3.50 Diameter(m)
2.62
Distance=5m
8000
6000
4000
2000
00
0
(LUX) (Foot-candles)
Diameter(m)
0.20.20.4 0.4 0.60.6 0.80.811
1858
3716
5574
7432
13
°
2812 703 312 176 Foot-candles(center)
30270 7570 3360 1890 LUX(center)
Beam opening(m)
5
1.14 10
2.29 15 20 Distance(m)
4.56 Diameter(m)
3.42
Beam angle 3 -Min zoom1
°
4000
3000
2000
1000
00
0
(LUX) (Foot-candles)
Diameter(m)
0.20.20.4 0.4 0.60.6 0.80.811
929
1858
2787
3716
Distance=5m
Beam
°
angle 42 with frost
654 1760 780
164 72 41 Foot-candles(center)
440 LUX(center)
7040
5
4.0 10
8.0 15
20 Distance(m)
16.20 Diameter(m)
12.0
44
°
1
1
2
2
3
3
4
4
5
5
6
7
7
6
0
Beam opening(m)
Distance=5m
8000
6000
4000
2000
00
0
(LUX) (Foot-candles)
Diameter(m)
0.40.40.8 0.8 1.21.2 1.61.62.0 2.0
186
372
557
743
Lamp:MSR 1200 SA
··
15

··
16
8. Technical specifications
US-model:
EU-model:
Voltage............................AC100/110/120V , 50/60Hz
Fuse................................T 30A@120V
Voltage............................AC
................................
MSR1200 SA GY22
-Colour temperature 6000K
-Average lifespan:750hrs
Focus: electronic linear focus
Zoom: electronic zoom 10 ~44
dichroic-filters, UV, CTF 6000K plus white step/linear rotation(plus bi-directional
rainbow -flow effect), Speed adjustable
-CMYcolour mixing system
-0-100% 3200K-6000K colour temperature correction
-Linear CMYand CTS
-Stands directly on the floor
-Mountshorizontally orvertically with2 clamps
-2 truss orientation
-Safety chain/cord attachment bolt
-Pan 530 , Tilt 280
-Micro-step scan effect, 8/16 Bit
-Auto-repositioning by photoelectric repositioning system
-Linearity move speed adjust.
-Length of base(includinghandles): 506 mm
-Width of yoke: 525 mm
-Height (head horizontal): 602 mm
-Weight (net): 58 kg
220/230/240V ,50/60Hz
Fuse T15
0W
CHS
000 LM
RatedPower 145
DMX512 Channel 18
Luminous 96
:
:
:
°°
°°
Colourwheel:
Pan / Tilt Movement:
CMY+CTC:
Dimensions and weight:
Rigging:
A @230V
Lamp
:
-
-
-
-Dimmer: smooth dimmer 0~100%
-Strobe: Variable speed 1~10 flashes/sec (plus random strobe effect)
-Frost filter: smooth adjust 0~100%
-Iris: Electronic linear iris
-6
Optical System:

Maintenance and cleaning
It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke-fluid
residues must not buildup onor within the fixture.Otherwise,the fixtures light-outputwill
be significantly reduced. Regular cleaning willnot only ensure the maximum light-output,
b
ut will also allow the fixture to function reliably throughout its life.Asoft lint-free cloth
moistened with any good glass cleaning fluid is recommended, under no circumstances
should alcohol or solvents be used!
The front objective lens will require weekly cleaning as smoke-fluid tends to building up
residues, reducing thelight-output very quickly.The cooling-fans should be cleaned
monthly.
Thegobos may be cleanedwitha softbrush.The interior of the fixture shouldbe cleaned at
least annually usinga vacuum-cleaner or an air-jet.
The dichroic colour-filters, the gobo-wheel and the internal lenses should be cleaned
monthly.
To ensure a proper function of the gobo-wheel , we recommend lubrication in six month
intervals.The quantity of oil must not be excessive in order to avoid that oil runs out when
the gobo-wheel rotates.
There are no serviceable parts inside the device except for the lamp and the fuse.Please refer
to the instructions under "Fitting/Exchanging the lamp".Maintenance and service
operations are only to be carried out by authorized dealers.
If the lamp burns out, the fine-wire fuse of the device might fuse, too.Only replace the fuse
by a fuse of same typeand rating.Before replacing the fuse, unplug mains lead.
1) Unscrew the fuseholder on the rear panel of the base with a fitting screwdriver from the
housing (anti- clockwise).
2) Remove the old fuse from the fuseholder.
3) Install the new fuse in the fuseholder.
4) Replace the fuseholder in the housing and fix it.
DANGER :Disconnectfrom the mains before startinganymaintenance work
Replacing the fuse
Procedure:
··
17
Table of contents
Other SilverStar Lighting Equipment manuals

SilverStar
SilverStar ECLIPSE MINI COLOR SS867 User manual

SilverStar
SilverStar CAM3/ETZ User manual

SilverStar
SilverStar ECLIPSE 1000 RGBAL HC SS5152 User manual

SilverStar
SilverStar FREZNO 250 HEX User manual

SilverStar
SilverStar NEPTUNE 700 PROFILE User manual

SilverStar
SilverStar YX-2007 User manual

SilverStar
SilverStar MX-COLOR User manual

SilverStar
SilverStar LT-VIII User manual

SilverStar
SilverStar SS9151SC User manual

SilverStar
SilverStar SS847 User manual