manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SImx
  6. •
  7. Fan
  8. •
  9. SImx Manrose Classic Series User manual

SImx Manrose Classic Series User manual

This manual suits for next models

8

Other SImx Fan manuals

SImx MixFlo Pro Series User manual

SImx

SImx MixFlo Pro Series User manual

SImx Manrose SF150 User manual

SImx

SImx Manrose SF150 User manual

SImx Manrose Classic Series User manual

SImx

SImx Manrose Classic Series User manual

SImx Manrose Classic XP125 User manual

SImx

SImx Manrose Classic XP125 User manual

SImx Manrose User manual

SImx

SImx Manrose User manual

SImx MANROSE ID230 Series User manual

SImx

SImx MANROSE ID230 Series User manual

Popular Fan manuals by other brands

Minka Group minkaAire Wave F843 instruction manual

Minka Group

Minka Group minkaAire Wave F843 instruction manual

Airflow Adroit DV50 instruction manual

Airflow

Airflow Adroit DV50 instruction manual

Vornado 270 Series owner's guide

Vornado

Vornado 270 Series owner's guide

comfort air TH-10D instruction manual

comfort air

comfort air TH-10D instruction manual

Livoo DOM386 instruction manual

Livoo

Livoo DOM386 instruction manual

Holmes BLIZZARD HAOF-90 owner's guide

Holmes

Holmes BLIZZARD HAOF-90 owner's guide

Taurus GRECO 16 ELEGANCE manual

Taurus

Taurus GRECO 16 ELEGANCE manual

Quorum PINNACLE installation instructions

Quorum

Quorum PINNACLE installation instructions

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Monte Carlo Fan Company

Monte Carlo Fan Company 3DIR58RBD-V1 Owner's guide and installation manual

Craftmade UH52 installation guide

Craftmade

Craftmade UH52 installation guide

Jocel JVA030658 instruction manual

Jocel

Jocel JVA030658 instruction manual

MIKA MFB1211/GR user manual

MIKA

MIKA MFB1211/GR user manual

Harbor Breeze RLG52NWZ5L manual

Harbor Breeze

Harbor Breeze RLG52NWZ5L manual

Allen + Roth L1405 instruction manual

Allen + Roth

Allen + Roth L1405 instruction manual

ViM KUBAIR F400 ECOWATT Technical manual

ViM

ViM KUBAIR F400 ECOWATT Technical manual

HIDRIA R10R-56LPS-ES50B-04C10 user guide

HIDRIA

HIDRIA R10R-56LPS-ES50B-04C10 user guide

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

BLAUBERG Ventilatoren

BLAUBERG Ventilatoren CENTRO-M 100 L user manual

Triangle Engineering HEAT BUSTER SPL Series owner's manual

Triangle Engineering

Triangle Engineering HEAT BUSTER SPL Series owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PUB7002 iss:07 12/17
Yellow - Switched Live
Orange - Permanent Live
Black - Neutral
INTERNAL WIRING
DETAILED VIEW
Only Adjust with power switched off.
Timer Adjustment for XF/XP150T, XF/XP150AT
Any fan with a time delay fitted will run approximately one minute after it has been switched off. The time delay can
be increased by firstly switching off the power to the fan, remove front cover, and insert a small allen key in to the slot,
marked in Diagram 3A, and turning clockwise to reduce the time and anti-clockwise to increase the time. Only
adjust with power switched off.
The minimum time the timer will run for is 20 seconds and the maximum is about 30 minutes.
NOTE: (i) The fan is to be installed so that the blades are 2.1m above the floor. For best results
this Extractor Fan should be fitted as high on the wall as possible, or if preferred, on the
ceiling.
(ii) Do not install the unit within a shower cubicle. Use our shower fan SF150 models
(iii) Switch off mains supply before making electrical connections. This system should
be installed by a qualified electrician.
(iv) This fan is double insulated and does not require an earth.
(v) When installing fan through an external wall, an external wall grille must be fitted
at all times.
DIAGRAM 3: Auto Shutter Models
DIAGRAM 3A: Timer Adjustment for Auto Shutter Fans XF/XP150AT
Thank you for selecting our Manrose 150mm Wall/Ceiling Fan.
Please read all instructions before commencing installation.
1. Cut a 160mm diameter hole in the wall. If the fan is to be fixed onto the ceiling ensure that
the hole is between the joists.
2. Fit 150mm ducting flush to the plaster.
3. Remove the cover from the fan by simply unclipping the fascia. The front cover screw and
plug are conveniently located within the fan housing as shown in diagram 1 & 2.
4. Hold the body of the fan against the wall or ceiling and mark the four screw holes and the
cable entry. IMPORTANT: Ensure that the fan is square on wall or ceiling.
5. Bring power cable into position, as marked. Allow an extra 230mm (9”) protruding to
facilitate connection. Fan should only be installed by fixed wiring, a flexible cord should not
be used.
6. If an XP150 kit - Select a suitable position on the outside wall for the weatherproof cowl.
Carefully remove the cowl from its housing by levering gently at the sides with a small
screwdriver. Cut a 160mm hole ensuring first that the area is free from obstruction.
7. Wiring of Standard/Pullcord Model XF/XP150 (see diagram 1)
(Pullcord model unsuitable for ceiling mounting)
The fan can be connected to the light switch so that the fan will start when the light is
switched on. The fan should not be accessible to a person using either the shower or the bath.
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm2
in section. All wiring must comply with current Regulations. This system should be installed by a
qualified electrician.
Wiring of Timer Model XF/XP150T (see diagram 2).
The fan can be connected to the light switch so that the fan will start when the light is
switched on. When the light switch or pullcord is switched off the fan will run for between 20
sec & 30 minutes (pre-set to 1 minute). The fan should not be accessible to a person using
either the shower or the bath.
MANROSE CLASSIC XF/XP150 CEILING/WALL
EXTRACTOR FANS
INSTALLATION INSTRUCTIONS C L A S S I C S E R I E S
We reserve the right to change specification without prior warning
Manrose is proudly distributed by Simx Limited
PO Box 14 347, Panmure, Auckland, NZ. Technical Support (09) 259 1662
e: [email protected] | www.simx.co.nz | www.manrose.com.au
IMPORTANT NOTE:
If your fan is equipped
with auto shutters it will
be fitted with a thermally
activated mechanism
that opens and closes
the shutters. When the
unit is turned on/off the
automatic shutters will
take approximately 45
seconds to respond.
Specifications:
Model: NZNVF150SBB; NZNVF150TBB; NZXF150ABB; NZXF150ATBB
Electrical: 220-240V ~ 50Hz
Fan Wattage: 25W (45W for auto shutter model)
Max Temp: 40˚C
Airflow: 87l/s (313m3hr) - free air performance
Max Pressure: 60 Pa
Sound Volume: 40 dB(A)
IP Rated: IP44 (except pullcord model IP24)
IMPORTANT
• Isolate the mains supply before making any electrical connections. This system
should be installed by a qualified electrician.
• When fitting through an external wall, an external grille must be fitted at all times.
• Fan should only be installed by fixed wiring, a flexible cord should not be used.
• The appliance is not intended for use by young children or infirm persons without supervision.
• Young children should be supervised to ensure that they do not play with the appliance.
• Precautions must be taken to avoid the back-flow of gases into the room from
the open flue of gas or other open-fire appliances when mounted in outside
windows or walls.
DIAGRAM 1: Standard & Pullcord Models:
DIAGRAM 2: Timer Models (XF/XP150)
Diagram 2A
Rotary adjuster
for time delay
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of 1mm2
in section. All wiring must comply with current Regulations. This system must be installed by a
qualified electrician.
Timer Adjustment XF150T & XP150T only
This time delay can be adjusted by firstly switching off the power to the fan and removing the
fascia. Locate the rotary adjuster as shown in Diagram 2. The serrated adjuster wheel can be
rotated using a thumbnail to adjust the timer setting.
+ = Rotate to the right to increase the time (indicated by + on the diagram)
- = Rotate to the left to decrease the time (indicated by - on the diagram)
Only adjust with power switched off.
8. Wiring of Autoshutter Models (XF/XP150AP) (see diagram 3)
(This model is unsuitable for ceiling mounting) This fan has its own integral pullcord on/off
switch. The fan should not be accessible to a person using either the shower or the bath.
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of
1mm2in section. All wiring must comply with current Regulations. This system should be
installed by a qualified electrician.
9. Wiring of Auto shutter Model XF/XP150AT (see diagram 3A)
When light switch or pullcord is switched off fan will run for a between 20 sec and 30 mins
(pre-set to 1 minute). The fan should not be accessible to a person using either the shower
or the bath.
NOTE: All wiring must be fixed securely and the cable to the fan should be a minimum of
1mm2in section. All wiring must comply with current Regulations. This system should
be installed by a qualified electrician.