Skyworth SMVH09D-1B1A3NA User manual

MODEL
SMVH09D-1B1A3NA
SMVH12D-1B1A3NA
(Refrigerant R32)

CONTENT
1. Summary and Features .............................................................................. 1
2. Safety Precautions...................................................................................... 2
3. Specifications.............................................................................................. 4
3.1 Unit Specifications..................................................................................................... 4
3.2 Operation Characteristic Curve ............................................................................... 7
3.3 Capacity Variation Ratio According to Temperature ............................................. 7
3.4 Cooling and Heating Data Sheet in Rated Frequency ........................................... 8
3.5 Noise Curve ............................................................................................................... 8
4. Function and Control.................................................................................. 9
4.1 Remote Controller Operations.................................................................................. 9
4.2 Description of Each Control Operation................................................................. 14
5. Installation Manual.................................................................................... 16
5.1 Safety operation of ammable refrigerant............................................................. 16
5.2 Notices for Installation ........................................................................................... 17
5.3 Installation Dimension Diagram ............................................................................ 19
5.4 Installation Indoor Unit ........................................................................................... 20
5.5 Installation Outdoor Unit ........................................................................................ 23
5.6 Check after installation........................................................................................... 26
5.7 Test operation.......................................................................................................... 26
5.8 Configuration of connection pipe.......................................................................... 27
5.9 Pipe expanding method.......................................................................................... 28
6. Construction Views................................................................................... 29
6.1 Indoor Unit ................................................................................................................ 29
6.2 Outdoor Unit ............................................................................................................. 30
7. Exploded Views and Parts List ................................................................ 31
7.1 Indoor Unit ................................................................................................................ 31
7.2 Outdoor Unit ............................................................................................................. 33
8. Schematic Diagram................................................................................... 37
8.1 Electrical Wiring ....................................................................................................... 37
8.2 PCB Printed Diagram............................................................................................... 39
9. Troubleshooting ........................................................................................ 42
9.1 Error Code List ......................................................................................................... 42
9.2 Procedure of Troubleshooting................................................................................ 45
10. Removal Procedure ................................................................................ 62
10.1 Removal Procedure of Indoor Unit....................................................................... 62
10.2 Removal Procedure of Outdoor Unit.................................................................... 66

1
Summary and Features
1. Summary and Features
Model Product Code Indoor unit Outdoor unit Power Supply Power Supply Intake
SMVH09D-1B1A3NA KEB001Z2470 SMVH09D-1B1A3NA(I) SMVH09D-1B1A3NA(O) 220-240V~,
50Hz,1Ph Outdoor Unit
SMVH12D-1B1A3NA KEB001Z2490 SMVH12D-1B1A3NA(I) SMVH12D-1B1A3NA(O)
Remote Controller
Outdoor Unit
SMVH09D-1B1A3NA(O)
Indoor Unit
Model: SMVH09D-1B1A3NA(I),SMVH12D-1B1A3NA(I)
SMVH12D-1B1A3NA(O)
RA1A1

2
Safety Precautions
2. Safety Precautions
Installing, starting up, and servicing air conditioner can be hazardous due to system pressure, electrical components, and
equipment location, etc.Only trained, qualied installers and service personnel are allowed to install, start-up, and service this
equipment.Untrained personnel can perform basic maintenance functions such as cleaning coils. All other operations should be
performed by trained service personnel.When handling the equipment, observe precautions in the manual and on tags, stickers,
and labels attached to the equipment. Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth
and re extinguisher nearby when brazing.Read the instructions thoroughly and follow all warnings or cautions in literature and
attached to the unit. Consult local building codes and current editions of national as well as local electrical codes.
Recognize the following safety information:
◆ Make sure the outdoor unit is installed on a stable, level surface with no accumulation of snow, leaves, or trash beside.
◆ Make sure the ceiling/wall is strong enough to bear the weight of the unit.
◆ Make sure the noise of the outdoor unit does not disturb neighbors.
◆ Follow all the installation instructions to minimize the risk of damage from earth quakes, typhoons or strong winds.
◆ Avoid contact between refrigerant and re as it generate spoisonous gas.
◆ Apply specied refrigerant only. Never have it mixed with any other refrigerant. Never have air remain in the refrigerant line as
it may lead to rupture and other hazards.
◆ Make sure no refrigerant gas is leaking out when installation is completed.
◆ Should there be refrigerant leakage, the density of refrigerant in the air shall in no way exceed its limited value, or it may lead
to explosion.
◆ Keep your ngers and clothing away from any moving parts.
◆ Clear the site after installation. Make sure no foreign objects are left in the unit.
◆ Always ensure effective grounding for the unit.
Incorrect handling could result inpersonal injury or death. Incorrect handling may result inminor injury,or damage to product
or property.
Warning Caution
Warning Caution
All electric work must be performed by a licensed technician
according to local regulations and the instructions given in
this manual.
Before installing, modifying, or servicing system,
mainelectrical disconnect switch must be in the OFF position.
There may be more than 1 disconnect switch. Lock out and
tag switch with a suitable warning label.
Never supply power to the unit unless all wiring and tubing
are completed, reconnected and checked.
This system adopts highly dangerous electrical voltage.
Incorrect connection or inadequate grounding can cause
personal injury or death. Stick to the wiring diagram and all
the instructions when wiring.
Have the unit adequately grounded in accordance with local
electrical codes.
Have all wiring connected tightly. Loose connection may lead
to overheating and a possible re hazard.
All installation or repair work shall be performed by your
dealer or a specialized subcontractor as there is the risk of
re, electric shock, explosion or injury.
Never install the unit in a place where a combustible gas
might leak, or it may lead to re or explosion.
Make a proper provision against noise when the unit is
installed at a telecommunication center or hospital.
Provide an electric leak breaker when it is installed in a
watery place.
Never wash the unit with water.
Handle unit transportation with care. The unit should not be
carried by only one person if it is more than 20kg.
Never touch the heat exchanger ns with bare hands.
Never touch the compressor or refrigerant piping without
wearing glove.
Do not have the unit operate without air lter.
Should any emergency occur, stop the unit and disconnect
the power immediately.
Properly insulate any tubing running inside the room to
prevent the water from damaging the wall.

3
Safety Precautions
Please read this operating manual carefully before operating the unit.
Appliance lled with ammable gas R32.
Before use the appliance, read the owner's manual rst.
Befoer install the appliance,read the installation manual rst.
Befoer repair the appliance ,read the service manual rst.
The gures in this manual may be different with the material objects ,please refer to the material objects for reference.
To realize the function of the air conditioner unit, a special refrigerant circulates in the system.The used refrigerant is the fluoride
R32,which is specially cleaned.The refrigerant is flammable and inodorous. Furthermore,it can leads to explosion under certain
condition.But the ammability of the refrigerant is very low. It can be ignited only by re.
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the ozonosphere.The influence upon the
greenhouse effect is also lower. R32 has got very good thermodynamic features which lead to a really high energy efciency. The units
therefore need a less lling.
The Refrigerant
WARNING:
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.Should repair
be necessary, contact your nearest authorized Service Center.
Any repairs carried out by unqualied personnel may be dangerous.
The appliance shall be stored in a room without continuously operating ignition sources.
(For example: open ames, an operating gas appliance or an operating electric heater.)
Do not pierce or burn.
Appliance shall be installed, operated and stored in a room with a oor area larger than
"X"m2(see table 1).(only applies to appliances that are not xed appliances)
Appliance lled with ammable gas R32. For repairs,strictly follow manufacturer's
instructions only.
Be aware that refrigerants not contain odour.
Read specialist’s manual.

4
Specifications
3. Specifications
3.1 Unit Specifications
Parameter Unit Value Value
Model -- SMVH09D-1B1A3NA SMVH12D-1B1A3NA
Product Code -- KEB001Z2470 KEB001Z2490
Power
Supply
Rated Voltage V~220-240 220-240
Rated Frequency Hz 50 50
Phases -- 1 1
Power Supply Mode -- outdoor outdoor
Cross-sectional Area of Power Cable Conductor mm21 1
Recommended Power Cable(Core) -- 3 3
Min/Max. Voltage V 198/264 198/264
Cooling Capacity W 2600 3500
Cooling Capacity Btu/h 8871 11942
Min. Cooling Capacity W 400 550
Min. Cooling Capacity Btu/h 1365 1877
Max. Cooling Capacity W 3300 4000
Max. Cooling Capacity Btu/h 11260 13648
Pdesignc KW 2.6 3.5
Heating Capacity W 2800 3800
Heating Capacity Btu/h 9554 12966
Min. Heating Capacity W 400 600
Min. Heating Capacity Btu/h 1364.8 2047.2
Max. Heating Capacity W 4100 5130
Max. Heating Capacity Btu/h 13989 17504
Pdesignh(Average) KW 2.6 3.2
Cooling Power Input W 650 875
Min. Cooling Power Input W 150 180
Max. Cooling Power Input W 1430 1560
Heating Power Input W 710 975
Min. Heating Power Input W 180 220
Max. Heating Power Input W 1550 1800
Cooling Current A 3.6 4.8
Heating Current A 3.4 4.4
Rated Input W 1550 1800
Rated Current A 6.88 7.99
EER W/W 4.00 4.00
EER (Btu/h)/W 13.65 13.65
COP W/W 3.94 3.90
COP (Btu/h)/W 13.46 13.30
SEER -- 8.6 8.6
SCOP(Average) -- 4.6 4.6
SCOP(Warmer) -- 5.4 5.3
SCOP(Colder) -- 3.6 3.6
Energy Class -- A+++<Cooling>/A++<Aver-
age>A+++<Warmer>A<Colder>
A+++<Cooling>/A++<Aver-
age>A+++<Warmer>A<Colder>
Air Flow Volume m3/h 550 650
Dehumidifying Volume L/h 0.8 1.4
Application Area m2 12-18 16-24

5
Specifications
Indoor
Unit
Indoor Unit Model -- SMVH09D-1B1A3NA(I) SMVH12D-1B1A3NA(I)
Fan Type -- Cross-ow Cross-ow
Fan Diameter Length(D×L) mm Ф97×673 Ф97×673
Cooling Speed (SH/H/L/SL) r/min 1250/1150/700/650 1350/1250/750/700
Heating Speed (SH/H/L/SL) r/min 1250/1150/850/800 1350/1250/900/850
Fan Motor Power Output W 20 20
Fan Motor RLA A 0.21 0.21
Evaporator Form -- Aluminum Fin-copper Tube Aluminum Fin-copper Tube
Evaporator Pipe Diameter mm Ф7 Ф7
Evaporator Row-n Gap mm 2-1.4 2-1.4
Evaporator Coil Length (L×D×W) mm 669×25.4×266 669×25.4×266
Swing Motor Model -- 24BJ-A3 24BJ-A3
Swing Motor Power Output W 1.5 1.5
Fuse Current A 3.15 3.15
Set Temperature Range ℃16~31 16~31
Sound Pressure Level(SH/H/L/SL) dB (A) 40/38/21/19 42/39/25/20
Sound Power Level dB (A) 50/48/31/29 52/49/35/30
Dimension (W×H×D) mm 910X303X200 910X303X200
Dimension of Carton Box (W×H×D) mm 994X284X371 994X284X371
Dimension of Package(W×H×D) mm 997X294X374 997X294X374
Stacked Layers -- 7 7
Net Weight kg 12 12
Gross Weight kg 15 15
Outdoor
Unit
Outdoor Unit Model -- SMVH09D-1B1A3NA(O) SMVH12D-1B1A3NA(O)
Compressor Trademark panasonic panasonic
Compressor Manufacturer --
panasonic Wanbao Applianc-
es Compressor(guangzhou)
CO.,LTD./panasonic
panasonic Wanbao Applianc-
es Compressor(guangzhou)
CO.,LTD./panasonic
Compressor Model -- 9RS092ZAB21 9RS102ZAA21
Compressor Oil -- FV50S or FW50S FV50S or FW50S
Compressor Type -- Rotary Rotary
Compressor LRA. A 20.2 16.5
Compressor RLA A 6.22 6.48
Compressor Power Input W 920 970
Fan Type -- Axial-ow Axial-ow
Fan Diameter mm 405 455
Fan Diameter inch 15.9 17.9
Fan Motor Speed rpm 880 720
Fan Motor Power Output W 30 55
Fan Motor RLA A 0.4 0.47
Outdoor Unit Air Flow Volume m3/h 1800 2800
Condenser Form -- Aluminum Fin-copper Tube Aluminum Fin-copper Tube
Condenser Pipe Diameter mm Ф7 Ф7
Condenser Rows-n Gap mm 2-1.4 2-1.4
Condenser Coil Length (L×D×W) mm 742×38.1×506 869×38.1×572
Permissible Excessive Operating
Pressure for the Discharge Side MPa 4.3 4.3
Permissible Excessive Operating
Pressure for the Suction Side MPa 2.5 2.5
Maximum Allowable Pressure MPa 4.3 4.3
Cooling Operation Ambient Tem-
perature Range ℃-15~54 -15~54

6
Specifications
The above data is subject to change without notice. Please refer to the nameplate of the unit.
Outdoor
Unit
Heating Operation Ambient Tem-
perature Range ℃-20~24 -20~24
Throttling Method -- Electron expansion valve Electron expansion valve
Defrosting Method -- Automatic Defrosting Automatic Defrosting
Climate Type -- T1 T1
Climate Zone -- Temperate Zone Temperate Zone
Isolation -- I I
Moisture Protection -- IP24 IP24
Sound Pressure Level dB (A) 52 53
Sound Power Level dB (A) 62 63
Dimension (W×H×D) mm 830x540x325 890x598x372
Dimension of Carton Box (W×H×D) mm 876x585x363 938x647x409
Dimension of Package(W×H×D) mm 879x605x366 941x663x412
Net Weight kg 30 38
Gross Weight kg 32.5 41
Refrigerant -- R32 R32
Refrigerant Charge kg 0.80 0.90
Connection
Pipe
Length m 5 5
Gas Additional Charge g/m 20 20
Outer Diameter of Liquid Pipe(Sky-
worth Allocation)(Metric) mm Ф6 Ф6
Outer Diameter of Liquid Pipe(Brit-
ish System Allocation) inch 1/4" 1/4"
Outer Diameter of Gas Pipe(Sky-
worth Allocation)(Metric) mm Ф9.52 Ф9.52
Outer Diameter of Gas Pipe(British
System Allocation) inch 3/8" 3/8"
Max Distance Height m 10 10
Max Distance Length m 20 20

7
Specifications
3.2 Operation Characteristic Curve
3.3 Capacity Variation Ratio According to Temperature
50
60
70
80
90
100
110
120
130
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Capacity ratio(%)
Outdoor temp. (°C)
Capacity ratio(%)
HeatingCooling
HeatingCooling
-20 -15-10 -5 0510
110
120
130
100
90
80
70
60
50
40
Outdoor temp.(°C)
50
60
70
80
90
100
110
120
130
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Capacity ratio(%)
Outdoor temp. (°C)
Capacity ratio(
%)
–15–10 –5
110
100
90
80
70
60
50
40
05
710
Conditions
Indoor:DB20°C
Indoor air flow:Super High
Pipe length:5m
Outdoor temp.(°C)
Condition
Indoor:DB27°C WB19°C
Indoor air flow:
High
Pipe length:5m
Condition
Indoor:DB27°C WB19°C
Indoor air flow:
High
Pipe length:5m
Condition
Indoor:DB20°C
Indoor air flow:
High
Pipe length:5m
Heating operation ambient temperature range is -20ºC~24ºC
Heating operation ambient temperature range is -15ºC~24ºC
Compressor Speed(rps)
Compressor Speed(rps)
Cooling
Heating
Current(A)
Current(A)
0
1
2
3
4
5
6
7
8
9
10
020406080 100 120
WB19
°C
0
1
2
3
4
5
6
7
8
020406080100
12
0
Condition
Indoor:DB 27°C
Indoor air flow: Super High
Pipe length:5m
Voltage:230V
Condition
Indoor:DB 20°C
Indoor air flow: Super High
Pipe length:5m
Voltage:230V

8
Specifications
3.4 Cooling and Heating Data Sheet in Rated Frequency
Model
Rated cooling
condition(°C) (DB/WB)
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit Outdoor fan
mode (rpm)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
Super High
09K
27/19 35/24 0.9~1.1 12 to 14 75 to 37
880
12K 720
T1: Inlet and outlet pipe temperature of evaporator; T2: Inlet and outlet pipe temperature of condenser;
P: Pressure of air pipe connecting indoor and outdoor units.
NOTES :
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.(Thermistor themometer)
(2) Connecting piping condition : 5m
Model
Rated heating
condition(°C) (DB/WB)
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit Outdoor fan
mode (rpm)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
Super High
09K 20/- 7/6 2.2~2.4 70 to 35 2 to 4 880
12K 720
3.5 Noise Curve
Indoor side noise when blowing Outdoor side noise when blowing
Indoor fan motor rotating speed Compressor frequency(Hz)
Noise/dB(A)
50
60
30
40
20
Low Middle High Super High
12K
09K
40
42
44
46
48
50
52
54
56
20 03045060708
090
Noise dB(A)
09&12K Cooling
09&12K Heating
●09K&12K

9
Function and Control
4. Function and Control
4.1 Remote Controller Operations
Turbo mode
Health function
Wi-Fi signal
Set fan speed
Child lock
Sleep mode
Up&down swing
Light
Dual-8 nixietube
Auto mode
Cooling mode
Dry mode
Fan mode
Heating mode
Clock display
Fan button
+ button
Left&right swing button
Light button
Timer off button
Timer on button
Health button
Clean button
button
I feel
Left&right swing
Up&down swing button
Turbo button Sleep button
Clock button
ECO button
I feel button
Quiet button
- button
ON/OFF button
Mode button
Quiet mode
Clean mode
ECO mode
Temp. display
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●●●●●
●
●
●
●
●
●
●
●
●
●
After connecting the power, the air conditioner will make a sound.
Power indicator is ON. After that, you can operate the air conditioner by using remote controller.
Under on status, pressing the button on the remote controller, the display will show the corresponding set function icons.
Under off status, light and clock icon will be displayed on the display of remote controller (If timer on, timer off and light functions are set, the
corresponding icons will be displayed on the display of remote controller at the same time).

10
Function and Control
ON/OFF button
Press this button can turn on or turn off the air conditioner.
MODE button
Press this button to select your required operation mode.
●
When selecting auto mode, air conditioner will operate automatically according to ex-factory
setting. Set temperature can’t be
adjusted and will not be displayed as well. Press "FAN" button can adjust fan speed. Press " " or " " button can adjust fan
blowing angle.
● After selecting cool mode, air conditioner will operate under cool mode. Press "+" or "-" button to adjust set temperature.
Press "FAN" button to adjust fan speed. Press " " or " " button to adjust fan blowing angle.
●
When selecting dry mode, the air conditioner operates at fan1, fan speed can’t be adjusted.
Press " " or " " button to adjust
fan blowing angle.
● When selecting fan mode, the air conditioner will only blow fan, no cooling and no heating. Press "FAN" button to adjust fan
speed. Press " " or " " button to adjust fan blowing angle.
● When selecting heat mode, the air conditioner operates under heat mode. Press "+" or "-" button to adjust set temperature.
Press "FAN" button to adjust fan speed. Press " " or " " button to adjust fan blowing angle. (Cooling only unit won’t receive
heat mode signal. If setting heat mode with remote controller, press "ON/OFF" button can’t start up the unit).
Note:
● For preventing cold air, after starting up heating mode, indoor unit will delay 1~5 minutes to blow air (actual delay time is depend
on indoor ambient temperature).
● Set temperature range from remote controller: 16~31°C; Fan speed: auto, fan1, fan2 , fan3 , fan4, fan5, stepless speed.
Auto Cool Dry Fan Heat
fan1 fan2 fan3
fan4fan5
stepless speed
AUTO
Note:
● When selecting " " with remote controller, it’s auto swing.
up&down swing louver
of air conditioner will swing up&down
automatically at the maximum angle.
● When selecting " , , , , " with remote controller, it's the xed position swing.
Up&down swing louver
of air
conditioner will stop at that position as shown by the icon to swing.
FAN button
Pressing this button can set fan speed circularly as: auto (AUTO), fan1( ), fan2 ( ) ,fan3 ( ) , fan4 ( ), fan5
( ), stepless speed.
Note:
● In AUTO speed, air conditioner will select proper fan speed automatically according to ambient temperature.
● Fan speed under dry mode is fan1.
● After entering the stepless speed mode, users can adjust the fan speed according to the button "+" or "-".
button
button
● Press this button the up&down swing function can be started and canceled. The remote controller defaults to static swing condition.
● Press "MODE" button and " " button at the same time when remote controller OFF to switch between simple swing and static
swing.
●
In static swing condition, pressing this button, the swing angle of up&down swing louver changes as
below:
● Press this button the left&right swing function can be started and canceled. The remote controller defaults to static swing condition.
●
Press "MODE" button and " " button at the same time at remote controller OFF to switch between simple swing and static swing.
●
In static swing condition, pressing this button, the swing angle of left&right swing louver changes
as below:
No display
No display

11
Function and Control
● Press this button to start or cancel clean function.
● It is unable to set clean function when the unit is on; if the air conditioner runs in cool or dry mode before turning off, press
"CLEAN" button and show " " then the clean function is on; press "CLEAN" button again, " " disappeared, then the clean
function is off, or running 10 mins in clean function then turn off automatically.
● In the rst power on, the clean function is off acquiescently.
● The clean function can not be set and displayed when the air conditioner is in auto, fan and heat mode before turn off.
CLEAN button
+ and - button
Press "+" or "-" button once to increase or decrease 1°C of set temperature. Holding "+" or "-" button, set temperature on remote
controller will change quickly. On releasing button after setting is nished, temperature indicator on indoor unit will change
accordingly. (Temperature can’t be adjusted under auto mode)
● When setting TIMER ON, TIMER OFF or CLOCK, press "+" or "-" button to adjust time (Refer to CLOCK, TIMER ON, TIMER
OFF buttons).
TURBO button
Press this button to turn on or turn off the TURBO function in cool,heat,fan mode.
Note:
● Press "QUIET" or "FAN" button the unit will quit this function.
● This function is no use in auto mode or dry mode.
● When selecting " " with remote controller, it’s auto swing.
left&right swing
louver of air conditioner will swing
left&right
automatically at the maximum angle.
● When selecting " , , , , , " with remote controller,it's the xed position swing.
Left&right swing
louver of air
conditioner will stop at that position as shown by the icon to swing.
● When selecting " ", it’s the circulating swing.
Left&right swing
louver of air conditioner will swing circularly according to the
angle as shown by the icon.
Note:
There is no this function for the units. If press this button, the main unit will sound, but it also runs under original status.
HEALTH button
Press this button to turn on or turn off the health function.
Note: This function is not available for some models.
SLEEP button
Press this button to turn on or turn off the SLEEP function under cool,heat ,dry mode.
Note:
● This function is off as defaulted after power on.
● It will be cleared after changing mode.
● It is no use under "FAN" mode and "AUTO" mode.
I FEEL button
Press this button to start I FEEL function and " " will be displayed on the remote controller. After this function is set, the remote
controller will send the detected ambient temperature to the indoor unit and the unit will automatically adjust the indoor temperature
according to the detected temperature. Press this button again to close I FEEL function and " " will disappear.
Note:
Please put the remote controller near user and conrm the unit can receive the remote code when this function is set. Do not put the
remote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature.
CLOCK button
Press this button to set clock time. " "and " " icon on remote controller will blink. Press "+" or "-" button within 5s to set
clock time. Each pressing of "+" or "-" button, clock time will increase or decrease 1 hour. Press this button again, " " and "
" icon on remote controller will blink. Press "+" or "-" button within 5s to set clock time. Press this button another time, "
" and " " icon on remote controller will blink. Press "+" or "-" button within 5s to set clock time. If hold "+" or "-" button, clock
time will change quickly. Release when reaching your required time. Press "CLOCK " button to conrm the time, " " icon stops
blinking.
Note:
● Clock time adopts 24-hour mode.
● The interval between two operation can’t exceeds 5s. Otherwise, remote controller will quit setting status. Operation for TIMER
ON/TIMER OFF is the same.

12
Function and Control
TIMER ON button
This button can set the time for timer on. After pressing this button, " " icon disappears, "ON" and " " icon on remote
controller blinks. Press "+" or "- "button within 5s to set "TIMER ON" time. Each pressing of "+" or "-" button, the time will increase
or decrease 1 hour. Press this button again, "ON" and " " icon on remote controller will blink. Press "+" or "-" button within 5s
to set the time. Press this button another time, "ON" and " " icon on remote controller will blink. Press "+" or "-" button within
5s to set the time. Hold "+"
or "-" button, the time will change quickly until reaching your required time. Press "TIMER ON"
to conrm
it. The word "ON" will stop blinking. " " icon resumes displaying.
Cancel TIMER ON
Under the condition that TIMER ON is started up, press "TIMER ON" button to cancel it.
TIMER OFF button
This button can set the time for timer off. After pressing this button, " " icon disappears, "OFF" and " " icon on remote
controller blink. Press "+" or "-" button within 5s to set "TIMER OFF" time. Each pressing of "+" or "-" button,the time will increase
or decrease 1 hour. Press this button again, "OFF" and " " icon on remote controller will blink. Press "+" or "-" button within
5s to set the time. Press this button another time, "OFF" and " " icon on remote controller will blink. Press "+" or "-" button
within 5s to set the time. Hold "+" or "-" button, the time will change quickly until reaching your required time.
Press "TIMER OFF" to conrm it.The word "OFF" will stop blinking. " " icon resumes displaying.
Cancel TIMER OFF
Under the condition that TIMER OFF is started up, press "TIMER OFF" button to cancel it.
QUIET button
Press this button to turn on or turn off the QUIET function in cool,heat,auto mode.
Note:
● Press "TURBO" or "FAN" button the unit will quit this function.
● This function is no use in fan mode or dry mode.
ECO button
In cool mode, press "ECO" button and the unit will operate under ECO mode.
Note:
● Remote controller displays " ".
● Air conditioner will operate at auto speed. Set temperature can’t be adjusted.
● Under cool mode, sleep function can not work with ECO mode together at the same time.
● Change mode will exit the ECO mode.
LIGHT button
Press this button can turn off the light for indoor unit’s display. " " icon on remote controller will disappear.Press this button again
to turn on the light for indoor unit’s display. " " icon on remote controller will be displayed.
Function introduction for combination buttons
Child lock function
Press "+" and "-" simultaneously to turn on or turn off child lock function. When child lock function is on, " " icon is displayed on
remote controller. If you operate the remote controller, the " " icon will blink three times without sending signal to the unit.
Temperature display switchover function
In the off mode, press "-" and "MODE" buttons simultaneously to switch temperature display between °C and °F.
button
Press this button to turn on or turn off the SMART function, for more details, please see next page for Smart APP User Guide.

13
Function and Control
● During operation, point the remote control signal sender at the receiving window on indoor unit.
● The distance between signal sender and receiving window should be no more than 8m, and there should be no obstacles
between them.
● Signal may be interfered easily in the room where there is uorescent lamp or wireless telephone; remote controller should be
close to indoor unit during operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the batteries.
● If the display on remote controller is fuzzy or there’s no display, please replace batteries.
NOTE:
Replacement of Batteries
1. Press the back side of remote controller marked with " ", as shown in the g,and then push out the cover of battery box
along the arrow direction.
2. Installation two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar are correct.
3. Reinstall the cover of battery box.
Setting the dehumidifying mode with 30 degree after the unit is powered on within 60s.And then press "LIGHT" →"SLEEP"
→"LIGHT" →"SLEEP",it could change the memory to not memory function.The light blink and show the error code 3s.
Memory setting
Press "light" and "-" button together for 3s,It could enter or exit this function.It will show the error code when this function is on.
Display by remote controller
Press the "FAN" and "MODE" 3s at the same time in heating mode,it will enter or exit the manually defrost.Remote controller will
display "dF" 5s,and it will show the setting temperature after 5s.
Manually defrost
Repowered within 5mins, set 16 degree under cooling mode, then press the "TURBO" button 6 times within 3s, will enter this
function.
Collecting freon
In the heating mode, press "SLEEP" and "TURBO" buttons together for 3s would start or cancel the Timing defrost.
Timing defrost
The minimum cooling temperature setting
In the off mode,pressing "TEMP"and "-" button at the same time,the LCD will display the minimum cooling temperature.The
default temperature is 16°C and you can adjust the temperature with "+" or "-" from 16°C to 31°C, 3 seconds later it will return to
the standby mode.
In the off mode,pressing "TEMP" and "+" button at the same time,the LCD will display the maximum heating temperature.The
default temperature is 31°C and you can modulate the temperature with "+" or "-" from 16°C to 31°C, 3 seconds later it will
return to the standby mode.
● In heating mode, pressing "Mode" and "+" button at the same time will enter/exit the low temperature heating function.
● "LA" would be showed on the remote controller after entered into the low temperature heating funtion.
● When switching from one mode to another mode, low temperature heating function was canceled. Turn off and then turn on
air conditioner that will remain the low temperature heating function. After powered on, the low temperature heating mode was
default to off status.
● In the low temperature heating mode, "SLEEP" and "Low temperature heating" function cannot start at same time.When low
temperature heating mode has already started,
meanwhile you press the "
SLEEP
" button, the air conditioner will exit low
temperature heating
mode and enter the sleep mode. Vice versa.
Note:
1. In the low temperature heating mode, the fan speed was default to Auto and non-ajusatable.
2. In the low temperature heating mode, "TURBO" and "QUIET" can't be set. If enter the low
temperature heating mode, the turbo
and quiet function that started before will be canceled. As well as when exit the low temperature heating mode, it will not resume.
3. When exit from the low temperature heating mode, the speed and temperature will turn into the original condition before it started.
4. You can set up other function.
The maximum heating temperature setting
Low temperature heating function setting

14
Function and Control
4.2 Description of Each Control Operation
4.2.1 The mainboard design with below function
(1) Auto (2) Cooling (3) Dehumidifying (4) Air fan (5) Heating
4.2.2 Control
Indoor fan(Quiet、speed 1、speed 2、speed 3、speed 4、speed 5、Turbo), left and right louver, up and down louver, buzzer,
display, outdoor electric heater(option), outdoor power, healthy(option).
4.2.3 Basis control function
Cooling mode
(1) Setting Temp 16-31 degree,the indoor fan and louver run as the original mode.
(2) The indoor will run as original mode if the outdoor does not work,and the indoor will show error code.
Fan
(1) Setting Temp 16-31 degree,the indoor fan and louver run as the original mode.
(2) The indoor will run as original mode if the outdoor does not work,and the indoor will show error code.
Heating mode
(1) Setting temperature range 16-31 degree.
(2) It will in anti-cold air rst when unit run in heating mode,and then heating.It will blow hot air after unit is off.
(3) Indoor power light blink and then indoor fan stop after unit entering defrost mode.
(4) Indoor blow hot air one minute if outdoor is malfunction.
(5) Indoor blow hot air 10 minutes after turn off unit when indoor fan is running.
4.2.4 Auto mode
(1) When environment temperature is equal or above 26 degree,and setting the cooling mode,the setting temperature will reach
25 degree.
(2)When the environment temperature i is equal or below 19 degree plus additional temperature,it will run in heating mode,and
the setting temperature reach 20 degree at that time.
(3) When 1(9 degree +additional temperature,)<environment temperature<26 degree.It will run in airfan mode if it is the rst time
entering auto mode.It will run in original mode if it change from cooling and heating mode.If original mode is dehumidifying,it will
be in airfan after change into auto mode.
4.2.5 Protect
(1)Anti cold air
The louver will be in horizontal level when evaporator temperature is too low,and indoor fan does not work or run in low speed.
(2)Blow hot air
Indoor will run in few minutes before turn off when turn off in heating or indoor temperature above environment temperature.
(3)Sensor malfunction
If the environment sensor or pipe sensor AD is above or equal 250 5s continually or the environment sensor or pipe sensor AD
is below 5 when the unit is on ,it means sensor malfunction.
(4)Motor blockage
When mainboard can not nd the indoor fan speed continually,or motor fan run in low speed continually ,compressor outdoor
fan,indoor fan and louver stop running.Indoor will show error code.
(5)Jumper malfunction
Un-install the jumper
(6)Communication malfunction
When the unit is running except for airfan mode,outdoor and indoor can not communicate 3 minutes.It will show error code.
(7)Defrost
When outdoor condensing defrost,it will start defrost mode.
(8)Manually Defrost
Press the "FAN" and "MODE" 3s at the same time in heating mode,it will enter or exit the manually defrost,and indoor will buzz.

15
Function and Control
4.2.6 Other Function
(1) Auto button
when you press this button,it will enter auto mode,indoor motor in auto fan speed,Indoor fan run and louver motor stop. Press
the auto button,unit will be off.
(2) Filter cleaning
Indoor motor fan run 600 hours ,unit will show CL to notice lter cleaning.The CL is off after turn off unit
(3) Health
Indoor healthy function start when push healthy button.
(4) Dry
Unit will run in cooling 10 min after set up dry function.
(5) Saving energy
Indoor will show in ECO after unit run in energy saving mode.
(6) Low temperature heating
Press "MODE" and "+" button at the same time in heating mode,it will show LA.
(7) Environment temperature
push temperature button,it will show environment temperature 5s and the setting temperature.
(8) Outdoor power
Power on,outdoor power is off.
(9) When unit is on except for fan mode,outdoor power supply input high frequency.
(10) Entering off mode or fan mode,outdoor power is off after 4 minutes.
(11) 1W Standby.
4.3.7 Display
(1) Basis display,Power on,it maintain 2s-3s display,and then power light is on.
(2) The running light is on when remote controller turn on unit,and indoor show the running mode.
(3) If turn off the light button,and all display is off.
(4) It displays as original mode after setting sleeping function.

16
Installation Manual
5. Installation Manual
5.1 Safety operation of ammable refrigerant
5.1.1 Qualication requirement for installation and maintenance man
All the work men who are engaging in the refrigeration system should bear thevalid certification awarded by the authoritative
organization and the qualicationfor dealing with the refrigeration system recognized by this industry. If it needsother technician
to maintain and repair the appliance, they should be supervisedby the person who bears the qualication for using the ammable
refrigerant.It can only be repaired by the method suggested by the equipment’s manufacturer.
5.1.2 Installation notes
1.The air conditioner is not allowed to use in a room that has running re (such as resource, working coal gas ware, operating heater).
2.It is not allowed to drill hole or burn the connection pipe.
3.The air conditioner must be installed in a room that is larger than the minimum roomarea.
The minimum room area is shown on the nameplate or following table 1.
4.Leak test is a must after installation.
Minimum
room area
( m2 )
Charge amount (kg) ≤1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 2.1 2.2 2.3 2.4 2.5
oor location / 14.5 16.8 19.3 22.0 24.8 27.8 31.0 34.4 37.8 41.5 45.4 49.4 53.6
window mounted / 5.2 6.1 7.0 7.9 8.9 10.0 11.2 12.4 13.6 15 16.3 17.8 19.3
wall mounted / 1.6 1.9 2.1 2.4 2.8 3.1 3.4 3.8 4.2 4.6 5 5.5 6.0
ceiling mounted / 1.1 1.3 1.4 1.6 1.8 2.1 2.3 2.6 2.8 3.1 3.4 3.7 4.0
5.1.3 Maintenance notes
Check whether the maintenance area or the room area meet the requirement of the nameplate.
—It’s only allowed to be operated in the rooms that meet the requirement of the nameplate.
Check whether the maintenance area is well-ventilated.
—The continuous ventilation status should be kept during the operation process.
Check whether there is fire source or potential fire source in the maintenance area.
—The naked ame is prohibited in the maintenance area; and the “no smoking” warning board should be hanged.
Check whether the appliance mark is in good condition.
—Replace the vague or damaged warning mark.
5.1.4 Welding
If you should cut or weld the refrigerant system pipes in the process of maintaining, please follow the steps as below:
1. Shut down the unit and cut power supply.
2. Eliminate the refrigerant.
3. Vacuuming.
4. Clean it with N2 gas.
5. Cutting or welding.
6. Carry back to the service spot for welding.
The refrigerant should be recycled into the specialized storage tank.Make sure that there isn’t any naked ame near the outlet
of the vacuum pumpand it’s well-ventilated.
Table 1:Minimum room area (m2)
5.1.5 Filling the refrigerant
1.Use the refrigerant lling appliances specialized for R32. Make sure that different kinds of refrigerant won’t contaminate with
each other.
2.The refrigerant tank should be kept upright at the time of lling refrigerant.
3.Stick the label on the system after lling is nished (or haven’t nished).
4.Don’t overlling.
5.After lling is nished, please do the leakage detection before test running; another time of leak detection should be done when
it’s removed.
5.1.6 Safety instructions for transportation and storage
1.Please use the ammable gas detector to check before unload and open the container.
2.No re source and smoking.
3.According to the local rules and laws.

17
Installation Manual
5.2 Notices for Installation
Caution
1.The unit should be installed only by authorized service center according to local or government regulations and in compliance
with this manual.
2.Before installing, please contact with local authorized maintenance center. If the unit is not installed by the authorized service
center, the malfunction may not be solved due to incovenient contact between the user and the service personnel.
3.When removing the unit to the other place, please rstly contact with the local authorized service center.
4.Warning: Before obtaining access to terminals, all supply circuits must be disconnected.
5.For appliances with type Y attachment, the instructions shall contain the substance of the following. If the supply cord is
damaged, it must be replaced by the manufacturer, its service agent or similarly qualied persons in order to avoid a hazard.
6.The appliance must be positioned so that the plug is accessible.
7.The temperature of refrigerant line will be high; please keep the interconnection cable away from the copper tube.
8.The instructions shall state the substance of the following:This appliance is not intended for use by persons(including
children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
9. Appliance shall be installed, operated and stored in a room with a oor area larger than "X"m2(see table 1).
1. When installing or relocating the unit, be sure to keep the refrigerant circuit free from air or substances other than the
specified refrigerant.
— Any presence of air or other foreign substance in the refrigerant circuit will cause system pressure rise or compressor rupture,
resulting in injury.
2. When installing or moving this unit, do not charge the refrigerant which is not comply with that on the nameplate or
unqualified refrigerant.
— Otherwise, it may cause abnormal operation, wrong action, mechanical malfunction or even series safety accident.
3. When refrigerant needs to be recovered during relocating or repairing the unit, be sure that the unit is running in cooling
mode.Then, fully close the valve at high pressure side (liquid valve).About 30-40 seconds later, fully close the valve at low
pressure side (gas valve), immediately stop the unit and disconnect power. Please note that the time for refrigerant
recovery should not exceed 1 minute.
— If refrigerant recovery takes too much time, air may be sucked in and cause pressure rise or compressor rupture, resulting in injury.
4. During refrigerant recovery, make sure that liquid valve and gas valve are fully closed and power is disconnected before
detaching the connection pipe.
— If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause
pressure rise or compressor rupture, resulting in injury.
5. When installing the unit, make sure that connection pipe is securely connected before the compressor starts running.
— If compressor starts running when stop valve is open and connection pipe is not yet connected, air will be sucked in and cause
pressure rise or compressor rupture, resulting in injury.
6. Prohibit installing the unit at the place where there may be leaked corrosive gas or ammable gas.
— If there leaked gas around the unit, it may cause explosion and other accidents.
7. Do not use extension cords for electrical connections. If the electric wire is not long enough, please contact a local service
center authorized and ask for a proper electric wire.
— Poor connections may lead to electric shock or re.
8. Use the specified types of wires for electrical connections between the indoor and outdoor units. Firmly clamp the wires
so that their terminals receive no external stresses.
— Electric wires with insufcient capacity, wrong wire connections and insecure wire terminals may cause electric shock or re.
WARNING
To ensure safety, please be mindful of the following precautions.
5.1.6 Installation prepare
Please notice that the unit is lled with ammable gas R32. Inappropriate treatment of the unit involves
the risk of severe damages of people andmaterial. Details to this refrigerant are found in chapter
"refrigerant".

18
Installation Manual
5.1.1 Installation Site Instructions
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local dealer:
1.The place with strong heat sources,vapors,ammable or explosive gas,or volatile objects spread in the air.
2.The place with high-frequency devices (such as welding machine,medical equipment).
3.The place near coast area.
4.The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.The appliance shall not be installed in the laundry.
1. There should be noobstruction near air inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and won't affect other people.
3. Select a location which is convenient to connect the outdoor unit and near the power socket.
4. Select a location which is out of reach for children.
5. The location should be ableto withstand the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m above oor.
7. Don't install the indoor unit right above the electric appliance.
8. Please try your best to keep way from uorescent lamp.
1.Select a location where the noise and out ow air emitted by the outdoor unit will not affect neighborhood.
2.The location should be well ventilated and dry, in which the outdoor unit won't be exposed directly to sunlight or strong wind.
3.The location should be able to withstand the weight of outdoor unit.
4.Make sure that the installation follows the requirement of installation dimension diagram.
5.Select a location which is out of reach for children and far away from animals or plants.If it is unavoidable, please add the
fence for safety purpose.
5.1.2 Installation Site of Indoor Unit
5.1.3 Installation Site of Outdoor Unit
5.1.4 Safety Precautions for Electric Appliances
1. A dedicated power supply circuit should be used in accordance with local electrical safety regulations.
2. Don't drag the power cord with excessive force.
3. The unit should be reliably earthed and connected to an exclusive earth device by the professionals.
4. The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload.
5. The minimum distance between the unit and combustive surface is 1.5m.
6. The appliance shall be installed in accordance with national wiring regulations.
7. An all-pole disconnection switch with a contact separation of at least 3mm in all poles should be connected in xed wiring.
Note:
● Make sure the live wire, neutral wire and earth wire in the family power socket are properly connected.
There should be reliable circuit in the diagram.
● Inadequate or incorrect electrical connections may cause electric shock or fire.
5.1.5 Earthing Requirements
1. Air conditioner is type I electric appliance. Please ensure that the unit is reliably earthed.
2. The yellow-green wire in air conditioner is the earthing wire which can not be used for other purposes. Improper earthing may
cause electric shock.
3. The earth resistance should accord to the national criterion.
4. The power must have reliable earthing terminal. Please do not connect the earthing wire with the following:
● Water pipe
● Gas pipe
● Contamination pipe
● Other place that professional personnel consider is unreliable
5. The model and rated values of fuses should accord with the silk print on fuse cover or related PCB.
This manual suits for next models
3
Table of contents
Other Skyworth Air Conditioner manuals

Skyworth
Skyworth SUV2-H18/3CFA-N User manual

Skyworth
Skyworth SMVH24A-5C1A3NG User manual

Skyworth
Skyworth SAVH12A-A1NAO User manual

Skyworth
Skyworth SDVH12M-A1NBI/P User manual

Skyworth
Skyworth SMVH09B-2A2A3NG User manual

Skyworth
Skyworth SKVH09A-A3NAI User manual

Skyworth
Skyworth SDVH12M-A3NAI User manual
Popular Air Conditioner manuals by other brands

Whirlpool
Whirlpool YACQ082XK1 Use and care guide

Mitsubishi Electric
Mitsubishi Electric MSZ-GL09NA Service manual

Aire-Flo
Aire-Flo 4AC13 Series Installation/start-up instructions/homeowners information manual

Klimaire
Klimaire KSIQ series installation manual

Carrier
Carrier 40GRQ owner's manual

Keystone
Keystone KSTSW08B user manual