Skyworth SMVH24A-5C1A3NG User manual

MODEL
SMVH09A-2C1A3NG
SMVH12A-3C1A3NG
SMVH18A-4C1A3NG
SMVH24A-5C1A3NG
(Refrigerant R32)

CONTENT
1. Summary and Features ..............................................................................1
2. Safety Precautions......................................................................................3
6SHFL¿FDWLRQV..............................................................................................5
8QLW6SHFL¿FDWLRQV.....................................................................................................5
3.2 Operation Characteristic Curve...............................................................................9
3.3 Capacity Variation Ratio According to Temperature .............................................9
3.4 Cooling and Heating Data Sheet in Rated Frequency .........................................10
3.5 Noise Curve .............................................................................................................10
4. Function and Control................................................................................ 11
4.1 Remote Controller Operations................................................................................ 11
4.2 Smart APP User Guide............................................................................................16
4.3 Description of Each Control Operation.................................................................22
5. Installation Manual....................................................................................24
6DIHW\RSHUDWLRQRIÀDPPDEOHUHIULJHUDQW.............................................................24
5.2 Notices for Installation ...........................................................................................25
5.3 Installation Dimension Diagram ............................................................................27
5.4 Installation Indoor Unit...........................................................................................28
5.5 Installation Outdoor Unit........................................................................................31
5.6 Check after installation...........................................................................................34
5.7 Test operation..........................................................................................................34
&RQ¿JXUDWLRQRIFRQQHFWLRQSLSH..........................................................................35
5.9 Pipe expanding method..........................................................................................36
6. Construction Views...................................................................................37
6.1 Indoor Unit................................................................................................................37
6.2 Outdoor Unit.............................................................................................................39
7. Exploded Views and Parts List................................................................ 41
7.1 Indoor Unit................................................................................................................41
7.2 Outdoor Unit.............................................................................................................49
8. Schematic Diagram...................................................................................55
8.1 Electrical Wiring.......................................................................................................55
8.2 PCB Printed Diagram...............................................................................................57

7URXEOHVKRRWLQJ ........................................................................................62
9.1 Error Code List.........................................................................................................62
3URFHGXUHRI7URXEOHVKRRWLQJ................................................................................65
10. Removal Procedure ................................................................................82
10.1 Removal Procedure of Indoor Unit.......................................................................82
10.2 Removal Procedure of Outdoor Unit....................................................................86

1
Summary and Features
1. Summary and Features
Indoor Unit
Model Product Code Indoor unit Outdoor unit Power Supply Power Supply Intake
SMVH09A-2C1A3NG KEB001Z2100 SMVH09A-2C1A3NG(I) SMVH09B-2A2A3NG(O)
220-240V~,
50Hz,1Ph Outdoor Unit
SMVH12A-3C1A3NG KEB001Z2090 SMVH12A-3C1A3NG(I) SMVH12B-3A2A3NG(O)
SMVH18A-4C1A3NG KEB001Z2080 SMVH18A-4C1A3NG(I) SMVH18B-4A2A3NG(O)
SMVH24A-5C1A3NG KEB001Z2110 SMVH24A-5C1A3NG(I) SMVH24B-5A2A3NG(O)
Remote Controller
RA1A1
Outdoor Unit
SMVH09B-2A2A3NG(O)
SMVH12B-3A2A3NG(O)
SMVH09A-2C1A3NG(I)
SMVH12A-3C1A3NG(I)
SMVH18A-4C1A3NG(I)
SMVH24A-5C1A3NG(I)

2
Summary and Features
Outdoor Unit
SMVH18B-4A2A3NG(O)
SMVH24B-5A2A3NG(O)

3
Safety Precautions
2. Safety Precautions
Installing, starting up, and servicing air conditioner can be hazardous due to system pressure, electrical components, and
HTXLSPHQWORFDWLRQHWF2QO\WUDLQHGTXDOL¿HGLQVWDOOHUVDQGVHUYLFHSHUVRQQHODUHDOORZHGWRLQVWDOOVWDUWXSDQGVHUYLFHWKLV
equipment.Untrained personnel can perform basic maintenance functions such as cleaning coils. All other operations should be
performed by trained service personnel.When handling the equipment, observe precautions in the manual and on tags, stickers,
and labels attached to the equipment. Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth
DQG¿UHH[WLQJXLVKHUQHDUE\ZKHQEUD]LQJ5HDGWKHLQVWUXFWLRQVWKRURXJKO\DQGIROORZDOOZDUQLQJVRUFDXWLRQVLQOLWHUDWXUHDQG
attached to the unit. Consult local building codes and current editions of national as well as local electrical codes.
Recognize the following safety information:
◆ Make sure the outdoor unit is installed on a stable, level surface with no accumulation of snow, leaves, or trash beside.
◆ Make sure the ceiling/wall is strong enough to bear the weight of the unit.
◆ Make sure the noise of the outdoor unit does not disturb neighbors.
◆ Follow all the installation instructions to minimize the risk of damage from earth quakes, typhoons or strong winds.
◆ $YRLGFRQWDFWEHWZHHQUHIULJHUDQWDQG¿UHDVLWJHQHUDWHVSRLVRQRXVJDV
◆ $SSO\VSHFL¿HGUHIULJHUDQWRQO\1HYHUKDYHLWPL[HGZLWKDQ\RWKHUUHIULJHUDQW1HYHUKDYHDLUUHPDLQLQWKHUHIULJHUDQWOLQHDV
it may lead to rupture and other hazards.
◆ Make sure no refrigerant gas is leaking out when installation is completed.
◆ 6KRXOGWKHUHEHUHIULJHUDQWOHDNDJHWKHGHQVLW\RIUHIULJHUDQWLQWKHDLUVKDOOLQQRZD\H[FHHGLWVOLPLWHGYDOXHRULWPD\OHDG
WRH[SORVLRQ
◆.HHS\RXU¿QJHUVDQGFORWKLQJDZD\IURPDQ\PRYLQJSDUWV
◆ Clear the site after installation. Make sure no foreign objects are left in the unit.
◆ Always ensure effective grounding for the unit.
Incorrect handling could result inpersonal injury or death. Incorrect handling may result inminor injury,or damage to product
or property.
Warning Caution
Warning Caution
All electric work must be performed by a licensed technician
according to local regulations and the instructions given in
this manual.
Before installing, modifying, or servicing system,
mainelectrical disconnect switch must be in the OFF position.
There may be more than 1 disconnect switch. Lock out and
tag switch with a suitable warning label.
Never supply power to the unit unless all wiring and tubing
are completed, reconnected and checked.
This system adopts highly dangerous electrical voltage.
Incorrect connection or inadequate grounding can cause
personal injury or death. Stick to the wiring diagram and all
the instructions when wiring.
Have the unit adequately grounded in accordance with local
electrical codes.
Have all wiring connected tightly. Loose connection may lead
WRRYHUKHDWLQJDQGDSRVVLEOH¿UHKD]DUG
All installation or repair work shall be performed by your
dealer or a specialized subcontractor as there is the risk of
¿UHHOHFWULFVKRFNH[SORVLRQRULQMXU\
Never install the unit in a place where a combustible gas
PLJKWOHDNRULWPD\OHDGWR¿UHRUH[SORVLRQ
Make a proper provision against noise when the unit is
installed at a telecommunication center or hospital.
Provide an electric leak breaker when it is installed in a
watery place.
Never wash the unit with water.
Handle unit transportation with care. The unit should not be
carried by only one person if it is more than 20kg.
1HYHUWRXFKWKHKHDWH[FKDQJHU¿QVZLWKEDUHKDQGV
Never touch the compressor or refrigerant piping without
wearing glove.
'RQRWKDYHWKHXQLWRSHUDWHZLWKRXWDLU¿OWHU
Should any emergency occur, stop the unit and disconnect
the power immediately.
Properly insulate any tubing running inside the room to
prevent the water from damaging the wall.

4
Safety Precautions
Please read this operating manual carefully before operating the unit.
$SSOLDQFH¿OOHGZLWKÀDPPDEOHJDV5
%HIRUHXVHWKHDSSOLDQFHUHDGWKHRZQHUVPDQXDO¿UVW
%HIRHULQVWDOOWKHDSSOLDQFHUHDGWKHLQVWDOODWLRQPDQXDO¿UVW
%HIRHUUHSDLUWKHDSSOLDQFHUHDGWKHVHUYLFHPDQXDO¿UVW
7KH¿JXUHVLQWKLVPDQXDOPD\EHGLIIHUHQWZLWKWKHPDWHULDOREMHFWVSOHDVHUHIHUWRWKHPDWHULDOREMHFWVIRUUHIHUHQFH
To realize the function of the air conditioner unit, a special refrigerant circulates in the system.The used refrigerant is the fluoride
5ZKLFKLVVSHFLDOO\FOHDQHG7KHUHIULJHUDQWLVIODPPDEOHDQGLQRGRURXV)XUWKHUPRUHLWFDQOHDGVWRH[SORVLRQXQGHUFHUWDLQ
FRQGLWLRQ%XWWKHÀDPPDELOLW\RIWKHUHIULJHUDQWLVYHU\ORZ,WFDQEHLJQLWHGRQO\E\¿UH
Compared to common refrigerants, R32 is a nonpolluting refrigerant with no harm to the ozonosphere.The influence upon the
JUHHQKRXVHHIIHFWLVDOVRORZHU5KDVJRWYHU\JRRGWKHUPRG\QDPLFIHDWXUHVZKLFKOHDGWRDUHDOO\KLJKHQHUJ\HI¿FLHQF\7KHXQLWV
WKHUHIRUHQHHGDOHVV¿OOLQJ
The Refrigerant
WARNING:
Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacture.Should repair
be necessary, contact your nearest authorized Service Center.
$Q\UHSDLUVFDUULHGRXWE\XQTXDOL¿HGSHUVRQQHOPD\EHGDQJHURXV
The appliance shall be stored in a room without continuously operating ignition sources.
)RUH[DPSOHRSHQÀDPHVDQRSHUDWLQJJDVDSSOLDQFHRUDQRSHUDWLQJHOHFWULFKHDWHU
Do not pierce or burn.
$SSOLDQFHVKDOOEHLQVWDOOHGRSHUDWHGDQGVWRUHGLQDURRPZLWKDÀRRUDUHDODUJHUWKDQ
"X"m2VHHWDEOHRQO\DSSOLHVWRDSSOLDQFHVWKDWDUHQRW¿[HGDSSOLDQFHV
$SSOLDQFH¿OOHGZLWKÀDPPDEOHJDV5)RUUHSDLUVVWULFWO\IROORZPDQXIDFWXUHUV
instructions only.
Be aware that refrigerants not contain odour.
Read specialist’s manual.

5
6SHFL¿FDWLRQV
6SHFL¿FDWLRQV
8QLW6SHFL¿FDWLRQV
Parameter Unit Value
Model -- SMVH09A-2C1A3NG SMVH12A-3C1A3NG
Product Code -- KEB001Z2100 KEB001Z2090
Power
Supply
Rated Voltage V~ 220-240 220-240
Rated Frequency Hz 50 50
Phases -- 1 1
Power Supply Mode -- outdoor outdoor
Cross-sectional Area of Power Cable Conductor mm21.0 1.0
Recommended Power Cable(Core) N 3 3
0LQ0D[9ROWDJH V 198/264 198/264
Cooling Capacity W 2600 3500
Min. Cooling Capacity W 400 550
0D[&RROLQJ&DSDFLW\ W 3300 4000
Pdesignc kW 2.6 3.5
Heating Capacity W 2800 3650
Min. Heating Capacity W 400 600
0D[+HDWLQJ&DSDFLW\ W 4100 5130
Pdesignh(Average) kW 2.6 3.2
Cooling Power Input W 750 1010
Min. Cooling Power Input W 150 180
0D[&RROLQJ3RZHU,QSXW W1430 1560
Heating Power Input W 745 970
Min. Heating Power Input W 180 220
0D[+HDWLQJ3RZHU,QSXW W 1550 1800
Cooling Current A 3.6 4.8
Heating Current A 3.4 4.4
Rated Input W 1550 1800
Rated Current A 6.88 7.99
EER W/W 3.47 3.47
COP W/W 3.76 3.76
SEER -- 6.7 6.5
SCOP(Average) -- 4.0 4.0
Energy Class -- A++<Cooling>/A+<Average> A++<Cooling>/A+<Average>
Air Flow Volume (cooling SH/H/L/SL) m3/h 520/440/230/150 580/500/300/230
Dehumidifying Volume L/h 0.80 1.40
Application Area m212-18 16-24
Indoor
Unit
Indoor Unit Model -- SMVH09A-2C1A3NG(I) SMVH12A-3C1A3NG(I)
Fan Type -- &URVVÀRZ &URVVÀRZ
Fan Diameter Length(D×L) mm Ɏî Ɏî
Cooling Speed (SH/H/L/SL) r/min 1300/1150/750/600 1350/1200/800/650
Heating Speed (SH/H/L/SL) r/min 1300/1150/850/800 1350/1200/900/850
Fan Motor Power Output W 18 20
Fan Motor RLA A 0.2 0.24
Fan Motor Capacitor ȝ) 11.5
Evaporator Form -- Aluminum Fin-copper Tube Aluminum Fin-copper Tube
Evaporator Pipe Diameter mm Ɏ Ɏ
(YDSRUDWRU5RZ¿Q*DS mm 2-1.4 2-1.4
Evaporator Coil Length (L×D×W) mm 584.4×22.8×266.7 635×22.8×306.3
Swing Motor Model -- 24BJ-A2 24BJ-A2
Swing Motor Power Output W 1.5 1.5
Fuse Current A 3.15 3.15
Set Temperature Range ć16~31 16~31
Sound Pressure Level (cooling) dB (A) 38/34/21/19 40/35/22/20
Sound Power Level dB (A) 51/47/34/32 53/48/35/33
Dimension (W×H×D) mm [[ [[
'LPHQVLRQRI&DUWRQ%R[:î+î' mm [[ [[
Dimension of Package(W×H×D) mm [[ [[
Stacked Layers -- 7 7
Net Weight kg 9 10
Gross Weight kg 11 12

6
6SHFL¿FDWLRQV
The above data is subject to change without notice. Please refer to the nameplate of the unit.
Outdoor
Unit
Outdoor Unit Model -- SMVH09B-2A2A3NG(O) SMVH12B-3A2A3NG(O)
Compressor Trademark panasonic panasonic
Compressor Manufacturer -- panasonic Wanbao Appliances
Compressor(guangzhou)
CO.,LTD./panasonic
panasonic Wanbao Appliances
Compressor(guangzhou)
CO.,LTD./panasonic
Compressor Model -- 9RS092ZAB21 9RS102ZAA21
Compressor Oil -- FV50S FV50S
Compressor Type -- Rotary Rotary
Compressor LRA. A 20.2 16.5
Compressor RLA A 6.22 6.48
Compressor Power Input W 855 970
Compressor Overload Protector -- -- --
Fan Type -- $[LDOÀRZ $[LDOÀRZ
Fan Diameter mm 405 405
Fan Motor Speed rpm 880 880
Fan Motor Power Output W 30 30
Fan Motor RLA A 0.4 0.4
Fan Motor Capacitor ȝ) //
Outdoor Unit Air Flow Volume m3/h 1800 1800
Condenser Form -- Aluminum Fin-copper Tube Aluminum Fin-copper Tube
Condenser Pipe Diameter mm Ɏ Ɏ
&RQGHQVHU5RZV¿Q*DS mm 1-1.4 2-1.4
Condenser Coil Length (L×D×W) mm 742×19.05×506 719×38.1×506
3HUPLVVLEOH([FHVVLYH2SHUDWLQJ
Pressure for the Discharge Side MPa 4.3 4.3
3HUPLVVLEOH([FHVVLYH2SHUDWLQJ
Pressure for the Suction Side MPa 2.5 2.5
0D[LPXP$OORZDEOH3UHVVXUH MPa 4.3 4.3
Cooling Operation Ambient
Temperature Range ć18~52 18~52
Heating Operation Ambient
Temperature Range ć-15~24 -15~24
Throttling Method -- Capillary Capillary
Defrosting Method -- Automatic Defrosting Automatic Defrosting
Climate Type -- T1 T1
Climate Zone -- Temperate Zone Temperate Zone
Isolation -- I I
Moisture Protection -- IP24 IP24
Sound Pressure Level dB (A) 52 53
Sound Power Level dB (A) 61 62
Dimension (W×H×D) mm 830X540X325 830X540X325
'LPHQVLRQRI&DUWRQ%R[:î+î' mm [[ [[
Dimension of Package(W×H×D) mm [[ [[
Stacked Layers -- 5 5
Net Weight kg 29 30
Gross Weight kg 31.5 32.5
Refrigerant -- R32 R32
Refrigerant Charge kg 0.52 0.78
Connection
Pipe
Length m 5 5
Gas Additional Charge g/m 20 20
Outer Diameter of Liquid Pipe inch 1/4" 1/4"
Outer Diameter of Gas Pipe inch 3/8" 3/8"
0D['LVWDQFH+HLJKW m10 10
0D['LVWDQFH/HQJWK m20 20

7
6SHFL¿FDWLRQV
Parameter Unit Value
Model -- SMVH18A-4C1A3NG SMVH24A-5C1A3NG
Product Code -- KEB001Z1550/KEB001Z2080 KEB001Z1560/KEB001Z2110
Power
Supply
Rated Voltage V~ 220-240 220-240
Rated Frequency Hz 50 50
Phases -- 1 1
Power Supply Mode -- outdoor outdoor
Cross-sectional Area of Power Cable Conductor mm21.5 2.5
Recommended Power Cable(Core) N 3 3
0LQ0D[9ROWDJH V 198/264 198/264
Cooling Capacity W 5270 6450
Min. Cooling Capacity W 1000 1400
0D[&RROLQJ&DSDFLW\ W 6700 7000
Pdesignc kW 5.2 6.4
Heating Capacity W 5500 6600
Min. Heating Capacity W 1100 1500
0D[+HDWLQJ&DSDFLW\ W 6800 7900
Pdesignh(Average) kW 5 6.2
Cooling Power Input W 1540 1840
Min. Cooling Power Input W 320 380
0D[&RROLQJ3RZHU,QSXW W 2460 2800
Heating Power Input W 1480 1750
Min. Heating Power Input W 350 400
0D[+HDWLQJ3RZHU,QSXW W 2300 2500
Cooling Current A 7.0 8.9
Heating Current A 6.3 8.4
Rated Input W 2300 2500
Rated Current A 10.20 11.09
EER W/W 3.42 3.51
COP W/W 3.72 3.77
SEER -- 6.3 6.4
SCOP(Average) -- 4.0 4.0
Energy Class -- A++<Cooling>/A+<Average> A++<Cooling>/A+<Average>
Air Flow Volume (cooling SH/H/L/SL) m3/h 850/760/570/480 1090/930/670/560
Dehumidifying Volume L/h 1.80 2.40
Application Area m225-36 37-54
Indoor
Unit
Indoor Unit Model -- SMVH18A-4C1A3NG(I) SMVH24A-5C1A3NG(I)
Fan Type -- &URVVÀRZ &URVVÀRZ
Fan Diameter Length(D×L) mm Ɏî Ɏî
Cooling Speed (SH/H/L/SL) r/min 1230/1130/900/800 1250/1100/850/750
Heating Speed (SH/H/L/SL) r/min 1350/1200/900/850 1250/1100/900/800
Fan Motor Power Output W 40 55
Fan Motor RLA A 0.36 0.47
Fan Motor Capacitor ȝ) 2.5 2.5
Evaporator Form -- Aluminum Fin-copper Tube Aluminum Fin-copper Tube
Evaporator Pipe Diameter mm Ɏ Ɏ
(YDSRUDWRU5RZ¿Q*DS mm 2-1.4 2-1.4
Evaporator Coil Length (L×D×W) mm 715×25.4×304.8 850×25.4×342.9
Swing Motor Model -- 35BJ-A1 35BJ-A1
Swing Motor Power Output W 2.5 2.5
Fuse Current A 3.15 3.15
Set Temperature Range ć16~31 16~31
Sound Pressure Level (cooling) dB (A) 47/44/31/29 48/44/35/33
Sound Power Level dB (A) 58/55/42/40 61/57/48/46
Dimension (W×H×D) mm [[ [[
'LPHQVLRQRI&DUWRQ%R[:î+î' mm [[ [[
Dimension of Package(W×H×D) mm [[ [[
Stacked Layers -- 7 7
Net Weight kg 13 16
Gross Weight kg 15.5 19

8
6SHFL¿FDWLRQV
The above data is subject to change without notice. Please refer to the nameplate of the unit.
Outdoor
Unit
Outdoor Unit Model -- SMVH18B-4A2A3NG(O) SMVH24B-5A2A3NG(O)
Compressor Trademark panasonic panasonic
Compressor Manufacturer -- panasonic Wanbao Appliances
Compressor(guangzhou)
CO.,LTD./panasonic
panasonic Wanbao Appliances
Compressor(guangzhou)
CO.,LTD./panasonic
Compressor Model -- 9RD132ZEA21 9RD160ZAA21
Compressor Oil -- FV50S FV50S
Compressor Type -- Rotary Rotary
Compressor LRA. A 23 25
Compressor RLA A 6.7 6.9
Compressor Power Input W 1260 1645
Compressor Overload Protector -- -- --
Fan Type -- $[LDOÀRZ $[LDOÀRZ
Fan Diameter mm 455 522
Fan Motor Speed rpm 850 800
Fan Motor Power Output W 55 60
Fan Motor RLA A 0.67 0.79
Fan Motor Capacitor ȝ) //
Outdoor Unit Air Flow Volume m3/h 2800 3300
Condenser Form -- Aluminum Fin-copper Tube Aluminum Fin-copper Tube
Condenser Pipe Diameter mm Ɏ Ɏ
&RQGHQVHU5RZV¿Q*DS mm 2-1.4 2-1.4
Condenser Coil Length (L×D×W) mm 869×38.1×572 878×38.1×660
3HUPLVVLEOH([FHVVLYH2SHUDWLQJ
Pressure for the Discharge Side MPa 4.3 4.3
3HUPLVVLEOH([FHVVLYH2SHUDWLQJ
Pressure for the Suction Side MPa 2.5 2.5
0D[LPXP$OORZDEOH3UHVVXUH MPa 4.3 4.3
Cooling Operation Ambient Temperature
Range ć18~52 18~52
Throttling Method -- Capillary Capillary
Defrosting Method -- Automatic Defrosting Automatic Defrosting
Climate Type -- T1 T1
Climate Zone -- Temperate Zone Temperate Zone
Isolation -- I I
Moisture Protection -- IP24 IP24
Sound Pressure Level dB (A) 55 59
Sound Power Level dB (A) 63 68
Dimension (W×H×D) mm [[ 960×700×396
'LPHQVLRQRI&DUWRQ%R[:î+î' mm [[ [[
Dimension of Package(W×H×D) mm [[ [[
Stacked Layers -- 4 4
Net Weight kg 40 43.5
Gross Weight kg 43 47
Refrigerant -- R32 R32
Refrigerant Charge kg 0.93 1.05
Connection
Pipe
Length m 5 5
Gas Additional Charge g/m 20 50
Outer Diameter of Liquid Pipe inch 1/4" 1/4"
Outer Diameter of Gas Pipe inch 1/2" 5/8"
0D['LVWDQFH+HLJKW m10 10
0D['LVWDQFH/HQJWK m25 25

9
6SHFL¿FDWLRQV
3.2 Operation Characteristic Curve
3.3 Capacity Variation Ratio According to Temperature
50
60
70
80
90
100
110
120
130
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Capacity ratio(%)
Outdoor temp. (°C)
Capacity ratio(%)
HeatingCooling
HeatingCooling
-20 -15 -10 -5 0 5 10
110
120
130
100
90
80
70
60
50
40
Outdoor temp.(°C)
50
60
70
80
90
100
110
120
130
32 33 34 35 36 37 38 39 40 41 42 43 44 45 46
Capacity ratio(%)
Outdoor temp. (°C)
Capacity ratio(
%)
–15 –10 –5
110
100
90
80
70
60
50
40
05710
Conditions
Indoor:DB20°C
Indoor air flow:Super High
Pipe length:5m
Outdoor temp.(°C)
Condition
Indoor:DB27°C WB19°C
Indoor air flow:
High
Pipe length:5m
Condition
Indoor:DB27°C WB19°C
Indoor air flow:
High
Pipe length:5m
Condition
Indoor:DB20°C
Indoor air flow:
High
Pipe length:5m
Heating operation ambient temperature range is -20ºC~24ºC
Heating operation ambient temperature range is -15ºC~24ºC
Compressor Speed(rps) Compressor Speed(rps)
Cooling Heating
Current(A)
Current(A)
0
1
2
3
4
5
6
7
8
9
10
0 20 40 60 80 100 120
WB19
°C
0
1
2
3
4
5
6
7
8
0 20 40 60 80 100
120
Condition
Indoor:DB 27°C
Indoor air flow: Super High
Pipe length:5m
Voltage:230V
Condition
Indoor:DB 20°C
Indoor air flow: Super High
Pipe length:5m
Voltage:230V

10
6SHFL¿FDWLRQV
3.4 Cooling and Heating Data Sheet in Rated Frequency
Model Rated cooling
condition(°C) (DB/WB)
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
H[FKDQJHU
Fan speed of
indoor unit Outdoor fan
mode (rpm)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
Super High
09K,12K 27/19 35/24 0.9~1.1 12 to 14 75 to 37 880
18K 850
24K 800
T1: Inlet and outlet pipe temperature of evaporator; T2: Inlet and outlet pipe temperature of condenser;
P: Pressure of air pipe connecting indoor and outdoor units.
NOTES :
0HDVXUHVXUIDFHWHPSHUDWXUHRIKHDWH[FKDQJHUSLSHDURXQGFHQWHURIKHDWH[FKDQJHUSDWK8EHQW7KHUPLVWRUWKHPRPHWHU
(2) Connecting piping condition : 5m
Model Rated heating
condition(°C) (DB/WB)
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
H[FKDQJHU
Fan speed of
indoor unit Outdoor fan
mode (rpm)
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
Super High
09K,12K 20/- 7/6 2.2~2.4 70 to 35 2 to 4 880
18K 850
24K 800
3.5 Noise Curve
Indoor side noise when blowing Outdoor side noise when blowing
Indoor fan motor rotating speed Compressor frequency(Hz)
Noise/dB(A)
50
60
30
40
20
Low Middle High Super High
12K
09K
40
42
44
46
48
50
52
54
56
20 0304 50607080 90
Noise dB(A)
09&12K Cooling
09&12K Heating
Indoor side noise when blowing Outdoor side noise when blowing
Indoor fan motor rotating speed Compressor frequency(Hz)
Noise/dB(A)
50
60
30
40
20
Low Middle High Super High
24K
18K
42
44
46
48
50
52
54
56
58
20 0304 5060708
090
Noise dB(A)
18&24K Cooling
18&24K Heating
●09K&12K
●18K&24K

11
Function and Control
4. Function and Control
4.1 Remote Controller Operations
Turbo mode
Health function
Wi-Fi signal
Set fan speed
Child lock
Sleep mode
Up&down swing
Light
'XDOQL[LHWXEH
Auto mode
Cooling mode
Dry mode
Fan mode
Heating mode Clock display
Fan button
+ button
Left&right swing button
Light button
Timer off button
Timer on button
Health button
Clean button
button
I feel
Left&right swing
Up&down swing button
Turbo button Sleep button
Clock button
ECO button
I feel button
Quiet button
- button
ON/OFF button
Mode button
Quiet mode
Clean mode
ECO mode
Temp. display
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
ȘȘȘȘȘ
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
Ș
After connecting the power, the air conditioner will make a sound.
Power indicator is ON. After that, you can operate the air conditioner by using remote controller.
Under on status, pressing the button on the remote controller, the display will show the corresponding set function icons.
Under off status, light and clock icon will be displayed on the display of remote controller (If timer on, timer off and light functions are set, the
corresponding icons will be displayed on the display of remote controller at the same time).

12
Function and Control
212))EXWWRQ
Press this button can turn on or turn off the air conditioner.
02'(EXWWRQ
Press this button to select your required operation mode.
Ɣ
:KHQVHOHFWLQJDXWRPRGHDLUFRQGLWLRQHUZLOORSHUDWHDXWRPDWLFDOO\DFFRUGLQJWRH[IDFWRU\
setting. Set temperature can’t be
adjusted and will not be displayed as well. Press "FAN" button can adjust fan speed. Press " " or " " button can adjust fan
blowing angle.
Ɣ$IWHUVHOHFWLQJFRROPRGHDLUFRQGLWLRQHUZLOORSHUDWHXQGHUFRROPRGH3UHVVRUEXWWRQWRDGMXVWVHWWHPSHUDWXUH
Press "FAN" button to adjust fan speed. Press " " or " " button to adjust fan blowing angle.
Ɣ
When selecting dry mode, the air conditioner operates at fan1, fan speed can’t be adjusted.
Press " " or " " button to adjust
fan blowing angle.
Ɣ:KHQVHOHFWLQJIDQPRGHWKHDLUFRQGLWLRQHUZLOORQO\EORZIDQQRFRROLQJDQGQRKHDWLQJ3UHVV)$1EXWWRQWRDGMXVWIDQ
speed. Press " " or " " button to adjust fan blowing angle.
Ɣ:KHQVHOHFWLQJKHDWPRGHWKHDLUFRQGLWLRQHURSHUDWHVXQGHUKHDWPRGH3UHVVRUEXWWRQWRDGMXVWVHWWHPSHUDWXUH
Press "FAN" button to adjust fan speed. Press " " or " " button to adjust fan blowing angle. (Cooling only unit won’t receive
heat mode signal. If setting heat mode with remote controller, press "ON/OFF" button can’t start up the unit).
Note:
Ɣ)RUSUHYHQWLQJFROGDLUDIWHUVWDUWLQJXSKHDWLQJPRGHLQGRRUXQLWZLOOGHOD\aPLQXWHVWREORZDLUDFWXDOGHOD\WLPHLVGHSHQG
on indoor ambient temperature).
Ɣ6HWWHPSHUDWXUHUDQJHIURPUHPRWHFRQWUROOHUa&)DQVSHHGDXWRIDQIDQIDQIDQIDQVWHSOHVVVSHHG
Auto Cool Dry Fan Heat
fan1 fan2 fan3
fan4fan5
stepless speed
AUTO
Note:
ƔWhen selecting " " with remote controller, it’s auto swing.
up&down swing louver
of air conditioner will swing up&down
DXWRPDWLFDOO\DWWKHPD[LPXPDQJOH
Ɣ:KHQVHOHFWLQJZLWKUHPRWHFRQWUROOHULWVWKH¿[HGSRVLWLRQswing.
Up&down swing louver
of air
conditioner will stop at that position as shown by the icon to swing.
)$1EXWWRQ
Pressing this button can set fan speed circularly as: auto (AUTO), fan1( ), fan2 ( ) ,fan3 ( ) , fan4 ( ), fan5
( ), stepless speed.
Note:
Ɣ,Q$872VSHHGDLUFRQGLWLRQHUZLOOVHOHFWSURSHUIDQVSHHGDXWRPDWLFDOO\DFFRUGLQJWRDPELHQWWHPSHUDWXUH
Ɣ)DQVSHHGXQGHUGU\PRGHLVIDQ
Ɣ$IWHUHQWHULQJWKHVWHSOHVVVSHHGPRGHXVHUVFDQDGMXVWWKHIDQVSHHGDFFRUGLQJWRWKHEXWWRQRU
EXWWRQ
EXWWRQ
ƔPress this button the up&down swing function can be started and canceled. The remote controller defaults to static swing condition.
ƔPress "MODE" button and " " button at the same time when remote controller OFF to switch between simple swing and static
swing.
Ɣ
In static swing condition, pressing this button, the swing angle of up&down swing louver changes as
below:
Ɣ3UHVVWKLVEXWWRQWKHOHIWULJKWVZLQJIXQFWLRQFDQEHVWDUWHGDQGFDQFHOHG7KHUHPRWHFRQWUROOHUGHIDXOWVWRVWDWLFVZLQJFRQGLWLRQ
Ɣ
Press "MODE" button and " " button at the same time at remote controller OFF to switch between simple swing and static swing.
Ɣ
In static swing condition, pressing this button, the swing angle of left&right swing louver changes
as below:
No display
No display

13
Function and Control
Ɣ3UHVVWKLVEXWWRQWRVWDUWRUFDQFHOFOHDQIXQFWLRQ
Ɣ,WLVXQDEOHWRVHWFOHDQIXQFWLRQZKHQWKHXQLWLVRQLIWKHDLUFRQGLWLRQHUUXQVLQFRRORUGU\PRGHEHIRUHWXUQLQJRIISUHVV
"CLEAN" button and show " " then the clean function is on; press "CLEAN" button again, " " disappeared, then the clean
function is off, or running 10 mins in clean function then turn off automatically.
Ɣ,QWKH¿UVWSRZHURQWKHFOHDQIXQFWLRQLVRIIDFTXLHVFHQWO\
Ɣ7KHFOHDQIXQFWLRQFDQQRWEHVHWDQGGLVSOD\HGZKHQWKHDLUFRQGLWLRQHULVLQDXWRIDQDQGKHDWPRGHEHIRUHWXUQRII
&/($1EXWWRQ
DQGEXWWRQ
Press "+" or "-" button once to increase or decrease 1°C of set temperature. Holding "+" or "-" button, set temperature on remote
FRQWUROOHUZLOOFKDQJHTXLFNO\2QUHOHDVLQJEXWWRQDIWHUVHWWLQJLV¿QLVKHGWHPSHUDWXUHLQGLFDWRURQLQGRRUXQLWZLOOFKDQJH
accordingly. (Temperature can’t be adjusted under auto mode)
Ɣ:KHQVHWWLQJ7,0(5217,0(52))RU&/2&.SUHVVRUEXWWRQWRDGMXVWWLPH5HIHUWR&/2&.7,0(5217,0(5
OFF buttons).
785%2EXWWRQ
Press this button to turn on or turn off the TURBO function in cool,heat,fan mode.
Note:
Ɣ3UHVV48,(7RU)$1EXWWRQWKHXQLWZLOOTXLWWKLVIXQFWLRQ
Ɣ7KLVIXQFWLRQLVQRXVHLQDXWRPRGHRUGU\PRGH
ƔWhen selecting " " with remote controller, it’s auto swing.
left&right swing
louver of air conditioner will swing
left&right
DXWRPDWLFDOO\DWWKHPD[LPXPDQJOH
ƔWhen selecting " , , , , , ZLWKUHPRWHFRQWUROOHULWVWKH¿[HGSRVLWLRQVZLQJ
Left&right swing
louver of air
conditioner will stop at that position as shown by the icon to swing.
ƔWhen selecting " ", it’s the circulating swing.
Left&right swing
louver of air conditioner will swing circularly according to the
angle as shown by the icon.
Note:
There is no this function for the units. If press this button, the main unit will sound, but it also runs under original status.
+($/7+EXWWRQ
Press this button to turn on or turn off the health function.
Note: This function is not available for some models.
6/((3EXWWRQ
Press this button to turn on or turn off the SLEEP function under cool,heat ,dry mode.
Note:
Ɣ7KLVIXQFWLRQLVRIIDVGHIDXOWHGDIWHUSRZHURQ
Ɣ,WZLOOEHFOHDUHGDIWHUFKDQJLQJPRGH
Ɣ,WLVQRXVHXQGHU)$1PRGHDQG$872PRGH
,)((/EXWWRQ
Press this button to start I FEEL function and " " will be displayed on the remote controller. After this function is set, the remote
controller will send the detected ambient temperature to the indoor unit and the unit will automatically adjust the indoor temperature
according to the detected temperature. Press this button again to close I FEEL function and " " will disappear.
Note:
3OHDVHSXWWKHUHPRWHFRQWUROOHUQHDUXVHUDQGFRQ¿UPWKHXQLWFDQUHFHLYHWKHUHPRWHFRGHZKHQWKLVIXQFWLRQLVVHW'RQRWSXWWKH
remote controller near the object of high temperature or low temperature in order to avoid detecting inaccurate ambient temperature.
&/2&.EXWWRQ
Press this button to set clock time. " "and " " icon on remote controller will blink. Press "+" or "-" button within 5s to set
clock time. Each pressing of "+" or "-" button, clock time will increase or decrease 1 hour. Press this button again, " " and "
" icon on remote controller will blink. Press "+" or "-" button within 5s to set clock time. Press this button another time, "
" and " " icon on remote controller will blink. Press "+" or "-" button within 5s to set clock time. If hold "+" or "-" button, clock
WLPHZLOOFKDQJHTXLFNO\5HOHDVHZKHQUHDFKLQJ\RXUUHTXLUHGWLPH3UHVV&/2&.EXWWRQWRFRQ¿UPWKHWLPH " icon stops
blinking.
Note:
Ɣ&ORFNWLPHDGRSWVKRXUPRGH
Ɣ7KHLQWHUYDOEHWZHHQWZRRSHUDWLRQFDQ¶WH[FHHGVV2WKHUZLVHUHPRWHFRQWUROOHUZLOOTXLWVHWWLQJVWDWXV2SHUDWLRQIRU7,0(5
ON/TIMER OFF is the same.

14
Function and Control
7,0(521EXWWRQ
This button can set the time for timer on. After pressing this button, " " icon disappears, "ON" and " " icon on remote
controller blinks. Press "+" or "- "button within 5s to set "TIMER ON" time. Each pressing of "+" or "-" button, the time will increase
or decrease 1 hour. Press this button again, "ON" and " " icon on remote controller will blink. Press "+" or "-" button within 5s
to set the time. Press this button another time, "ON" and " " icon on remote controller will blink. Press "+" or "-" button within
5s to set the time. Hold "+"
or "-" button, the time will change quickly until reaching your required time. Press "TIMER ON"
WRFRQ¿UP
it. The word "ON" will stop blinking. " " icon resumes displaying.
Cancel TIMER ON
Under the condition that TIMER ON is started up, press "TIMER ON" button to cancel it.
7,0(52))EXWWRQ
This button can set the time for timer off.After pressing this button, " " icon disappears, "OFF" and " " icon on remote
controller blink. Press "+" or "-" button within 5s to set "TIMER OFF" time. Each pressing of "+" or "-" button,the time will increase
or decrease 1 hour. Press this button again, "OFF" and " " icon on remote controller will blink. Press "+" or "-" button within
5s to set the time. Press this button another time, "OFF" and " " icon on remote controller will blink. Press "+" or "-" button
within 5s to set the time. Hold "+" or "-" button, the time will change quickly until reaching your required time.
3UHVV7,0(52))WRFRQ¿UPLW7KHZRUG2))ZLOOVWRSEOLQNLQJ " icon resumes displaying.
Cancel TIMER OFF
Under the condition that TIMER OFF is started up, press "TIMER OFF" button to cancel it.
48,(7EXWWRQ
Press this button to turn on or turn off the QUIET function in cool,heat,auto mode.
Note:
Ɣ3UHVV785%2RU)$1EXWWRQWKHXQLWZLOOTXLWWKLVIXQFWLRQ
Ɣ7KLVIXQFWLRQLVQRXVHLQIDQPRGHRUGU\PRGH
(&2EXWWRQ
In cool mode, press "ECO" button and the unit will operate under ECO mode.
Note:
Ɣ5HPRWHFRQWUROOHUGLVSOD\V ".
Ɣ$LUFRQGLWLRQHUZLOORSHUDWHDWDXWRVSHHG6HWWHPSHUDWXUHFDQ¶WEHDGMXVWHG
Ɣ8QGHUFRROPRGHVOHHSIXQFWLRQFDQQRWZRUNZLWK(&2PRGHWRJHWKHUDWWKHVDPHWLPH
Ɣ&KDQJHPRGHZLOOH[LWWKH(&2PRGH
/,*+7EXWWRQ
Press this button can turn off the light for indoor unit’s display. " " icon on remote controller will disappear.Press this button again
to turn on the light for indoor unit’s display. " " icon on remote controller will be displayed.
Function introduction for combination buttons
Child lock function
Press "+" and "-" simultaneously to turn on or turn off child lock function. When child lock function is on, " " icon is displayed on
remote controller. If you operate the remote controller, the " " icon will blink three times without sending signal to the unit.
Temperature display switchover function
In the off mode, press "-" and "MODE" buttons simultaneously to switch temperature display between °C and °F.
EXWWRQ
3UHVVWKLVEXWWRQWRWXUQRQRUWXUQRIIWKH60$57IXQFWLRQIRUPRUHGHWDLOVSOHDVHVHHQH[WSDJHIRU6PDUW$338VHU*XLGH

15
Function and Control
Ɣ'XULQJRSHUDWLRQSRLQWWKHUHPRWHFRQWUROVLJQDOVHQGHUDWWKHUHFHLYLQJZLQGRZRQLQGRRUXQLW
Ɣ7KHGLVWDQFHEHWZHHQVLJQDOVHQGHUDQGUHFHLYLQJZLQGRZVKRXOGEHQRPRUHWKDQPDQGWKHUHVKRXOGEHQRREVWDFOHV
between them.
Ɣ6LJQDOPD\EHLQWHUIHUHGHDVLO\LQWKHURRPZKHUHWKHUHLVÀXRUHVFHQWODPSRUZLUHOHVVWHOHSKRQHUHPRWHFRQWUROOHUVKRXOGEH
close to indoor unit during operation.
Ɣ5HSODFHQHZEDWWHULHVRIWKHVDPHPRGHOZKHQUHSODFHPHQWLVUHTXLUHG
Ɣ:KHQ\RXGRQ¶WXVHUHPRWHFRQWUROOHUIRUDORQJWLPHSOHDVHWDNHRXWWKHEDWWHULHV
Ɣ,IWKHGLVSOD\RQUHPRWHFRQWUROOHULVIX]]\RUWKHUH¶VQRGLVSOD\SOHDVHUHSODFHEDWWHULHV
NOTE:
Replacement of Batteries
3UHVVWKHEDFNVLGHRIUHPRWHFRQWUROOHUPDUNHGZLWKDVVKRZQLQWKH¿JDQGWKHQSXVKRXWWKHFRYHURIEDWWHU\ER[
along the arrow direction.
2. Installation two 7# (AAA 1.5V) dry batteries, and make sure the position of "+" polar and "-" polar are correct.
5HLQVWDOOWKHFRYHURIEDWWHU\ER[
Setting the dehumidifying mode with 30 degree after the unit is powered on within 60s.And then press "LIGHT" Į"SLEEP"
Į"LIGHT" Į"SLEEP",it could change the memory to not memory function.The light blink and show the error code 3s.
Memory setting
3UHVVOLJKWDQGEXWWRQWRJHWKHUIRUV,WFRXOGHQWHURUH[LWWKLVIXQFWLRQ,WZLOOVKRZWKHHUURUFRGHZKHQWKLVIXQFWLRQLVRQ
'LVSOD\E\UHPRWHFRQWUROOHU
3UHVVWKH)$1DQG02'(VDWWKHVDPHWLPHLQKHDWLQJPRGHLWZLOOHQWHURUH[LWWKHmanually defrost.Remote controller will
display "dF" 5s,and it will show the setting temperature after 5s.
Manually defrost
Repowered within 5mins, set 16 degree under cooling mode, then press the "TURBO" button 6 times within 3s, will enter this
function.
Collecting freon
In the heating mode, press "SLEEP" and "TURBO" buttons together for 3s would start or cancel the Timing defrost.
Timing defrost
The minimum cooling temperature setting
In the off mode,pressing "TEMP"and "-" button at the same time,the LCD will display the minimum cooling temperature.The
default temperature is 16°C and you can adjust the temperature with "+" or "-" from 16°C to 31°C, 3 seconds later it will return to
the standby mode.
,QWKHRIIPRGHSUHVVLQJ7(03DQGEXWWRQDWWKHVDPHWLPHWKH/&'ZLOOGLVSOD\WKHPD[LPXPKHDWLQJWHPSHUDWXUH7KH
default temperature is 31°C and you can modulate the temperature with "+" or "-" from 16°C to 31°C, 3 seconds later it will
return to the standby mode.
Ɣ,QKHDWLQJPRGHSUHVVLQJ0RGHDQGEXWWRQDWWKHVDPHWLPHZLOOHQWHUH[LWWKHORZWHPSHUDWXUHKHDWLQJIXQFWLRQ
Ɣ/$ZRXOGEHVKRZHGRQWKHUHPRWHFRQWUROOHUDIWHUHQWHUHGLQWRWKHORZWHPSHUDWXUHKHDWLQJIXQWLRQ
Ɣ:KHQVZLWFKLQJIURPRQHPRGHWRDQRWKHUPRGHORZWHPSHUDWXUHKHDWLQJIXQFWLRQZDVFDQFHOHG7XUQRIIDQGWKHQWXUQRQ
air conditioner that will remain the low temperature heating function. After powered on, the low temperature heating mode was
default to off status.
Ɣ,QWKHORZWHPSHUDWXUHKHDWLQJPRGH6/((3DQG/RZWHPSHUDWXUHKHDWLQJIXQFWLRQFDQQRWVWDUWDWVDPHWLPH:KHQORZ
temperature heating mode has already started,
meanwhile you press the "
SLEEP
EXWWRQWKHDLUFRQGLWLRQHUZLOOH[LWORZ
temperature heating
mode and enter the sleep mode. Vice versa.
Note:
1. In the low temperature heating mode, the fan speed was default to Auto and non-ajusatable.
2. In the low temperature heating mode, "TURBO" and "QUIET" can't be set. If enter the low
temperature heating mode, the turbo
DQGTXLHWIXQFWLRQWKDWVWDUWHGEHIRUHZLOOEHFDQFHOHG$VZHOODVZKHQH[LWWKHORZWHPSHUDWXUHKHDWLQJPRGHLWZLOOQRWUHVXPH
:KHQH[LWIURPWKHORZWHPSHUDWXUHKHDWLQJPRGHWKHVSHHGDQGWHPSHUDWXUHZLOOWXUQLQWRWKHRULJLQDOFRQGLWLRQEHIRUHLWVWDUWHG
4. You can set up other function.
The maximum heating temperature setting
Low temperature heating function setting

16
Function and Control
4.2 Smart APP User Guide
4.2.1 Download the Easy Home AMS Application(Referrer to as APP hereinafter)
Search "Easy Home AMS" to download Andriod versionAPP from Google Play and
search "Easy Home AMS" to download IOS version APP from App Store.
4.2.2 Production Introduction
Easy Home air conditioner is functioning based on the built-in smart module SWM100 through the Wi-Fi network, that the
mobile phones or other mobile devices can be connected to the Easy Home air conditioner to monitor and control the air
conditioning status after installing the Easy Home AMS APP.
4.2.3 Parameter of Smart Module SWM100
Model SWM100
Transmitting Frequency 2.4G
Transmitting Power G%P
Power Supply 12V DC / 0.5A
Operating Temperature -10ć~70ć
Operating humidity 10%-90%RH
4.2.4 Precautions for Use
(1) Please ensure both air conditioner and mobile phone connect to the same Wi-Fi hot pot when
FRQ¿JXUH
(2) Air conditioners can only be controlled by APP when connecting to the same routher as mobile
phone.
(3) Supported Devices:
ƔAndroid phone/tablet:(Requires Android 4.4 or later version.)
7XUQRQ\RXUSKRQHĺ6HWWLQJVĺ$ERXWGHYLFHĺ&KHFNWKH$QGURLGYHUVLRQ
ƔL26L3KRQHL3DGL3RG7RXFK5HTXLUHVL26RUODWHUYHUVLRQ
7XUQRQ\RXUL3KRQHĺ6HWWLQJVĺ*HQHUDOĺ$ERXWĺ&KHFNWKHFXUUHQWYHUVLRQ
(4) ThisAPP support wireless router with WPA/WPA2 connected encryption or no
password. 5G wireless router is temporarily not supported.
4.5 Cellphone data will be generated in the use of 3G/4G network of mobile phone.
model number
Andriod version 4.4.4 KTU84P
MIUI 7.0 Stable
7.0.5.0(KXDCNCI)
Quad-core 2.3GHz
MIUI version
CPU
about phone
21:09
Available 1.6GB
version 8.4.1(12H321)
20.0
MGA92ZP/A
Carrier
Model
General
21:09
4.2.5 Add Air Conditioner
(1)3OHDVH¿QGWKHRSHUDWLQJVWHSVDQGPHWKRGDERXWGRZQORDG$33LQ&KDSWHUIRUGHWDLO
(2) Add Air Conditioner.
Ɣ&RPSOHWHWKHIROORZLQJVWHSVWRUHJLVWHUIRU$QGURLG\VWHP
$6PDUW0RGXOHFRQ¿JXUDWLRQ
Connect the mobile phone with wireless router, turn on the power of the air conditioner, press " " button of the remote
FRQWUROOHUWRVWDUWWKH:L)LFRQ¿JXUDWLRQ
B. Press "add Air Conditioner" in the APP, chose "No/ Don’t know"LILWLVWKH¿UVWVWDUW
Please follow the instruction in Chapter 6, point 1 To add air conditioner, if it has been connected to Wi-Fi hotspot.
C. Follow the interface instruction, long press the " " button of the remote controller for 2 seconds, the air conditioner will enter
FRQ¿JXUDWLRQPRGHLIWKHIROORZLQJWKUHHSKHQRPHQDDSSHDUDWWKHVDPHWLPH
Ȕ
After long beep sound from air conditioner, and there will be another short beep sound.
ȔAir conditioner will display "A2" for 3 seconds.
ȔThe Wi-Fi indication light will blink once every second on air conditioner panel.
TTIMER
LC
Distance ≤ 8m
Enter Home
Enter Home
Enter Home
Y
es
Does your air-conditioning has been
connected to the netword yet?
No/Don’t kno
w
21:09
Yes
No/Don’t know
Next
please lon
g
press the AC remote
control about 2 seconds toward
AC,When hear a long and a short
beep,The AC enters configuration
state.
21:09
Next

17
Function and Control
':DLWLQJIRU$33DXWRPDWLFDOO\VHDUFKIRUFRQ¿JXUHWKH$LUFRQGLWLRQHU
Click to choose air conditioner on the list.
Notice:
Air conditioner hotspot name and password
FDQEH¿QGDWWKHOHIWFRUQHU
of the indoor unit.
Hot spot Name: SkySAC _XXXX
Hot spot Password: 88888888 Refresh
Search for air conditioners
Wait for connecting...14
21:09
Refresh
S
e
ar
c
hfo
r
air condi
t
ion
e
r
s
9
Q
_
9
'
)
>>>>
21
:
09
Search for air conditioners
9Q_9')>>>>
21:09
Connect
SSID:
PS
W:
21
:
09
SSID:
PSW:
Connect
Cancel
Network Connecting
Connecting...99
21:09
ZKYZ')
21:09
z
z
z
25đ
18
17
16
19
2
0
2
1
RTPM2.5Wiping
Mode Sleep Swing Speed Light
ON
đ
5TROTK
E. Choose the Wi-Fi network , type in the password and press "connect" to connect. Two beep sound from air conditioner
indicates the connection is successful. Air conditioner panel will display "A3" for 3 seconds, the APP will enter operation
interface at the same time.
The APP will remind after the connection failure. Please check theAPP failure by the instruction.
Notice:
ƹSupport WPA/WPA2 wireless router connected encryption.
ƹ5G wireless router is not supported.
ƹThe password should limit in 8-32 characters or without password.
Cancel
Connecting Failed
21:09
Please check the network is ok
Please check air condictioners
connect to the power
TTIMER
LC
Distance ≤ 8m
Enter Home
Enter Home
Enter Home
Y
es
Does your air-conditioning has been
connected to the netword yet?
No/Don’t kno
w
21:09
Yes
No/Don’t know
Next
please lon
g
press the AC remote
control about 2 seconds toward
AC,When hear a long and a short
beep,The AC enters configuration
state.
21:09
Next
Ɣ&RPSOHWHWKHIROORZLQJVWHSVWRUHJLVWHUIRUL26V\VWHP
$6PDUW0RGXOHFRQ¿JXUDWLRQ
Connect the mobile phone with wireless router, turn on the power of the air conditioner, press " " button of the remote
FRQWUROOHUWRVWDUWWKH:L)LFRQ¿JXUDWLRQ
B. Press "add Air Conditioner" in the APP, chose "No/ Don’t know"LILWLVWKH¿UVWVWDUW
Please follow the instruction in Chapter 6, point 1 To add air conditioner, if it has been connected to Wi-Fi hotspot.
C. Follow the interface instruction, long press the " " button of the remote controller for 2 seconds, Then after long beep and
VKRUWEHHSKRWVSRW6N\6$&B;;;;ZLOODSSHDUIRUFRQ¿JXUDWLRQIURPDLUFRQGLWLRQHU
7KHODVWGLJLWVRIKRWVSRWQDPHIURPQXPEHUDQG$)(QJOLVKOHWWHUVFRPSRVLWLRQWKHDLUFRQGLWLRQHUZLOOHQWHUFRQ¿JXUDWLRQ
status.
7KHDLUFRQGLWLRQHUZLOOHQWHUFRQ¿JXUDWLRQPRGHLIWKHIROORZLQJWKUHHSKHQRPHQDDSSHDUDWWKHVDPHWLPH
Ȕ
After long beep sound from air conditioner, and there will be another short beep sound.
ȔAir conditioner will display "A2" for 3 seconds.
ȔThe Wi-Fi indication light will blink once every second on air conditioner panel.
This manual suits for next models
7
Table of contents
Other Skyworth Air Conditioner manuals

Skyworth
Skyworth SUV2-H18/3CFA-N User manual

Skyworth
Skyworth SMVH09D-1B1A3NA User manual

Skyworth
Skyworth SDVH12M-A1NBI/P User manual

Skyworth
Skyworth SDVH12M-A3NAI User manual

Skyworth
Skyworth SKVH09A-A3NAI User manual

Skyworth
Skyworth SMVH09B-2A2A3NG User manual

Skyworth
Skyworth SAVH12A-A1NAO User manual
Popular Air Conditioner manuals by other brands

Hitachi
Hitachi RAM-55QH4 Service manual

York
York DJ 300 Technical guide

Technibel
Technibel MCAV77C5VAB Technical data & service manual

Daikin
Daikin VRV III REMQ8P8Y1B installation manual

Fujitsu
Fujitsu AS*G09KXCA Series Service instruction

EIC Solutions
EIC Solutions AAC-145A-4XT Series Installation and operation manual