SLS Lab Pro User manual

United Kingdom:
International:
Northern Ireland:
Republic of Ireland:
SLS Lab Pro Safevac Aspiration System
LA
B
PRO
User Manual
Please read the instructions and use the equipment
safely under the manual. Appearance and
performance are subject to change.
We will not notify and please contact to check.
Product Code: SLS4950

SLS Lab Pro Safevac Aspiration System
LA
B
PRO
Contents ..........................................................................
Preface ............................................................................
How to Get Help ..............................................................
Warranty ..........................................................................
1. Safety Precautions ......................................................
2. Range of application ...................................................
3. Inspection ....................................................................
3.1 Unpacking ..............................................................
3.2 Packing List ............................................................
4. Structure ......................................................................
5. Operating .....................................................................
6. Failure diagnosis .........................................................
7. Maintenance and Cleaning...........................................
Related Standards ..........................................................
8. Specifications ..............................................................
9. Ordering information ...................................................
Contents
1
1
2
2
2
3
3
4
4
4
4/5
6
6
6
7
7
7

Preface
Welcome to the Safevac Aspiration System guide. Please read the
operation manual carefully before using the instrument, pay attention
to the safety precautions and follow the instructions and operation
specifications.
How to Get Help
If you encounter any problems during installing and using, please get in
touch with your local SLS Sales office.
Contact details as follow:
Scientific Laboratory Supplies Ltd
Wilford Industrial Estate
Ruddington Lane
Wilford
Nottingham
NG11 7EP
United Kingdom:
Tel:+44(0) 115 982 1111
www.scientificlabs.co.uk
Republic of Ireland:
Tel: +353(0) 1 4069464
www.scientificlabs.ie
International:
Tel: +44(0) 115 977 5060
www.scientificlabs.com
Please prepare the following information:
• Product serial number (instrument nameplate)
• Warranty Card
• Description of problem
• Actions which you have done to solve the problem
• Your phone, fax and Email address and other contact information
Warranty
We guarantee a our SLS Lab Pro aspirators for a 12 month warranty
period under normal use.
SLS Lab Pro Safevac Aspiration System
LA
B
PRO
2

SLS Lab Pro Safevac Aspiration System
LA
B
PRO
1. Safety Precautions
Caveat!
• Please read manual carefully before operating the
instrument and follow all safety norms
• Train the person before operating the instrument
Safety grounding protection!
• Be sure the power outlet is properly
grounded before power on the instrument
• When running the instrument, wear suitable protective garment to
ensure staff safety
•
Put the instrument in a wide and airy place, and ensure surfaces are
clean, non-slip, dry and fireproof. Do not operate the instrument
outside, close to water or hazardous substances
• Avoid using unsafe containers
• Make sure the power supply voltage is consistent with the
requirements of the label and the instrument and its accessories
are not damaged
• Before running the instrument each time, check “Accessories”
listed and install accessories in accordance with the instructions to
ensure safety. Accessories must be firmly connected to the
instrument and avoid detachment
• During running, avoid touching valves, injection pumps, piping and
other components. Also, do not move the product
• If the liquid accidentally spills out , shut down immediately and wipe
off the liquid and clean organic solvent to guarantee the necessary
security
• Only unplug the instrument when it has fully powered down
• Be sure only professionally trained personal open the instrument
• No other heavy objects can be on the equipment
2. Range of application
This instrument is for schools, laboratories and factories, and other
application environments designed for liquid dilution and distribution as
following environment:
• No more than 2000 metres above sea level
• Temperature at 0ºC to 40ºC
• Installation type: product is designed to connect the indoor outlet,
voltage fluctuations not exceeding ± 10% of normal
• Inter-instrument, the minimum distance to the wall is 100mm.
The instrument is not suitable for application in residential areas as
well as some of the restrictions specified in Chapter 1
3

SLS Lab Pro Safevac Aspiration System
LA
B
PRO
3. Inspection
3.1 Unpacking
Any packaging damage when you receive, please record.
Upon arrival make a note of any damage to the packaging.
Note!
If there is any visible damage on the instrument,
do not connect with power.
3.2 Packing List
Name
Host computer
Waste container
Pipette
Aspiration handle
Vacuuming
Power Adapter
Instructions
Table 1
4. Structure
Quantity
1
1
1
1
1
1
1
4
•no more than 2000 meters above sea level
•temperature at 0 ℃to 40 ℃
•Installation type: product is designed to connect the
indoor outlet, voltage fluctuations not exceeding ± 10%
of normal
•Inter-instrument, the minimum distance to the wall is
100mm.
The instrument is not suitable for application in residential
areas as well as some of the restrictions specified in
Chapter 1.
3. Inspection
3.1 Unpacking
Any packaging damage when you receive, please indicate.
After unpacking, please get in touch with your local
supplier or manufacturer if you find any internal damage.
Note::
If there is any visible damage on the instrument,
do not connect with power.
3.2 Packing List
Name
Quantity
Host computer
1
Waste container
1
Pipette
1
Aspiration handle
1
Vacuuming
1
Power Adapter
1
Instructions
1
Table 1
4. Structure
VVaaccuuuumm
rreegguullaattiioonn
kknnoobb
VVaaccuuuummlleevveell
iinnddiiccaattoorr
MMaaiinnuunniitt
BBoottttlleeffoorrlliiqquuiidd
ccoolllleeccttiioonn
TTuubbiinnggffoorrvvaaccuuuumm
TTuubbiinnggffoorr
aabbssoorrbbiinngglliiqquuiidd
LLeevveerrsseennssoorr
AAiirrrreelleeaassee
vvaallvvee
LLiidd
BBoottttlleehhaannddllee
HHaannddooppeerraattoorr
Lever Sensor
Tubing for vacuum
Tubing for
Hand operator
absorbing liquid
Bottle for liquid
collection
Main unit
Vacuum
regulation
knob
Vacuum level
indicator
Bottle handle
Lid
Air release
valve
Drawing 1
5
Drawing 1
ffiilltteerr
TTuubbiinnggffoorr
vvaaccuuuumm
LLeevveerrsseennssoorr
PPoowweerrIInntteerrffaaccee
PPoowweerrsswwiittcchh
Drawing 2
Host
computer
The main part of the instrument,
Vacuum pump inside
Waste
container
use to storing liquid waste
Waste lid
Push-in fitting with the piping, level
sensor interface and release valve.
Corresponding plug into the
corresponding interface of the lid to
ensure connections are tight. Quick
plug for fast plug the pipeline, when
unplugged, press and hold the metal
shrapnel, remove the pipe.
Aspiration
handle
Press and hold the button on the
handle fluid suction, the alignment of
liquid to be learned, can be pipetting
work
Level Sensors
Detecting the level of waste liquid
containers. When the level exceeds the
warning, the pump alarm. The sensor
will detect the level of the waste liquid.
It will shut down the pump if the liquid
waste is out of the safe level.
Vacuuming
road
Waste container with a vacuum pump
connected to the host, provide a
negative pressure environment.
This tube use to do waste liquid
transport which from the operation
handle
Suction line
Waste container is connected with
aspiration handle, draw the liquid work
The Vacuum pump connect with the
container by this tube
Multipurpose
Bracket
Installed between the waste container
and the cap can be placed by aspiration
Drawing 2
Filter
Tubing for
vacuum
Lever Sensor
Power Interface
Power Switch
4

SLS Lab Pro Safevac Aspiration System
LA
B
PRO
Host computer
Waste container
Waste lid
Aspiration handle
Level Sensors
Vacuuming road
The main part of the instrument, vacuum pump
inside.
Used for storing liquid waste.
Push-in fitting with the piping, level sensor
interface and release valve. Corresponding plug
into the corresponding interface of the lid to
ensure connections are tight. Quick plug for fast
sealing of the pipeline, when unplugged, press
and hold the metal shrapnel to remove the pipe.
Press and hold the button on the handle for
fluid suction, the operator can use the correct
pipette adapter to draw up the sample.
Detecting the level of waste liquid containers.
When the level exceeds the warning, the pump
alarm sounds. The sensor will detect the level
of the waste liquid. It will shut down the pump
if the liquid waste is out of the safe level.
Waste container with a vacuum pump
connected to the host, provide a negative
pressure environment. This tube used to
transport liquid waste from the operation
handle.
Suction line
Multipurpose
Bracket
Release valve
Vacuum level
indicator
Vacuum adjusting
knob
Filter
Power Interface
Switch
Waste container is connected with aspiration
handle, the suction line draws liquid via the
vaccum pump into the container.
Installed between the waste container and the
cap can be placed by aspiration handle, while
moving the waste containers can be used as a
handle.
Screw off the device to release the vacuum
degree of waste containers and balance the air
pressure of inside and outside waste container.
Indicate the degree of vacuum, steady light
means reached the set vacuum, flashing
means adjusting to vacuum level setting.
Adjust the desired degree of vacuum.
Connected with the host and waste containers
to prevent the liquid from entering the vacuum
pump.
Power Interface.
Turns the Host on or off
Table 2
5

5. Operating
SLS Lab Pro Safevac Aspiration System
LA
B
PRO
1. Piping installation as above shown to ensure the pipeline
connected, no leakage.
2. Make sure the discharge valve is closed.
3. Turn the power switch.
4. Vacuum regulator knob clockwise, when the light is on, set the
vacuum level.
5. The light will become steady indicating that the system has
reached the desired vacuum. indicating that the system has
reached the set value the degree of vacuum, pressing the
handle button, you can then contact with the liquid suction waste
container.
6. Shut down the system.
7. Loosen the bleed valve, you can reset the vacuum degree.
8. Remove the waste container, unscrew the lid waste, discard.
• Instruments can’t start when power on
- Check whether the power line is unplugged
- Check whether the fuse is broken or loose
• Self test is abnormal when power on
6. Failure diagnosis
• Switch OFF the unit, then reset
• Unit cannot be powered off when switched off
If these faults are not resolved, please contact manufacturer/supplier.
• Proper maintenance can keep instruments working properly and
prolong its lifetime
• Do not spray cleanser into the instrument when cleaning
• Unplug the power line when cleaning
• Only use recommended cleansers:
• Wear the proper protective gloves during cleaning of the
instrument
• Before using other method for cleaning or decontamination,
please check with the manufacturer that this method will not
harm the instrument
7. Maintenance and Cleaning
Dyes
Construction materials
Cosmetics
Foodstuffs
Fuels
Isopropyl alcohol
Water containing tenside / Isopropyl alcohol
Water containing tenside / Isopropyl alcohol
Water containing tenside
Water containing tenside
6

SLS Lab Pro Safevac Aspiration System
LA
B
PRO
• Before shipping for repair, please pack the instrument with the
original carton
• If you will not use the instrument, please switch off the power and
place it in dry, clean, normal temperature, stable environment
Warning!
Cut off power when maintenance and cleaning.
Instrument structure conforms to the following safety standards
EN 61010-1
UL 3101-1
CAN/CSA C22.2(1010-1)
EN 61010-2-10
Instrument structure conforms to the following EMC standards
EN 61326-1
Comply with the following European standards
EMC Standard: 2004/108/EC
Mechanical Design Standard: 73/023/EWG
Voltage 100 – 240 VAC, 50/60 Hz
Vacuum range -300 to -600 mbar (adjustable)
Pumping speed 8 L/min (air)
Aspiration rate 17 ml/s (aspiration pipette)
Noise < 50 dB(A) (1 Metre)
Size (H x W x D) 53 x 18 x 32 cm (for reference)
Weight 3.4 kg (for reference)
Related Standards
8. Specifications
Table 3
9. Ordering information
Code Description
SLS4950 SLS Lab Pro Safevac Vacuum Aspiration System
7
Other manuals for Lab Pro
2
This manual suits for next models
1
Table of contents
Other SLS Laboratory Equipment manuals