Green LED on: Operation
The green LED is ashing: Waiting for sucient irradiation.
Red LED on: Disturbance: contact installer.
Blue LED on: The inverter has been incorporated into a Bluetooth network and can
communicate with other devices with identical NetID.
Blue LED is ashing: The inverter was identied via Sunny Explorer by setting the "Find device"
parameter.
• Electrical installation, repairs and modication should only be carried out by a trained
electrically skilled person.
• The appliance is not to be used by children or persons with reduced physical, sensor
or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction.
• Children should be supervised to ensure that they do not play with the appliance.
The PV generator has been short-circuited, if the Sunny Tripower beeps because of a fault
in the generator. The PV plant is now in a safe state.
• Do not, under any circumstances, disconnect the Electronic Solar Switch or the DC
plug connectors.
• Contact your installer immediately for repair.
• Only touch the lower lid and display during operation.
The inverter energy is shown as a diagram on the display. The
daily graph is displayed by default. The right-hand ashing bar
of the diagram represents the current hour. If the inverter does not
feed any power to the grid over a longer period of time (e.g. in
darkness or if the PV modules are covered with snow), a gap is
inserted into the chart. The column for the current hour is updated
automatically every ve seconds.
After four seconds, the bar goes off for one second and then
displays the current value.
The power and energy of the inverter are displayed in three elds: Power, Day and Total. The display
is updated every 5 seconds.
The power that the inverter is currently feeding into the grid.
The energy fed into the grid on this particular day. This equals the
energy generated between the inverter's daily start-up to the current
time.
The total energy the inverter has fed into the grid during its entire
operating time.
Serial number
Identication of the inverter by the type label
Lower case cover
Graphic display
Electronic Solar Switch
LEDs
The display values may deviate from the actual values and should not be used as a basis for
invoicing. The inverter's measured values are required for the system management and to control the
current to be fed to the grid. The inverter does not have a calibrated meter.
Current power
Daily energy
Total energy generated since inverter installation
Text line for displaying an event
Graphical display of the inverter energy/power
The display updates the values of your PV system every 5 seconds.
Tapping on the enclosure lid:
• Activates the background illumination
• Switches from the energy values of the past 16 feed-in
hours to the daily energy values for the past 16 days
• Switches to the next text line
Malfunction:
Contact installer
Switch open: no feeding-in
Switch closed: feeding
Output voltage/output current of the phase as shown below
Bluetooth connection with other devices
Input voltage/input current
Grid event number
PV-generator event number Inverter event number
Power reduction due to excessive temperature
• Clean the fans
• Provide better ventilation for the inverter
AB
Phase Assignment
Switches between the inputs
A and B every 10 seconds